Job Name/Location: |
|
|
|
|
|
|
Tag #: |
Date: |
|
|
|
|
|
|
|
|
|
For: File |
Resubmit |
|
|||
PO No.: |
|
|
Approval |
Other |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Architect: |
GC: |
|
|
|
|
||
Engr: |
Mech: |
|
|
|
|
||
Rep: |
|
|
|
|
|
|
|
(Company) |
(Project Manager) |
|
|
|
|
LMN079HVT
Multi F Wall Mounted High Efficiency Indoor Unit
7,000 Btu/h
Performance:
Nominal Cooling Capacity (Btu/h) |
7,000 |
Nominal Heating Capacity (Btu/h) |
8,100 |
|
|
Cooling Nominal Test Conditions: |
Heating Nominal Test Conditions: |
Indoor: 80°F DB / 67°F WB |
Indoor: 70°F DB / 60°F WB |
Outdoor: 95°F DB / 75°F WB |
Outdoor: 47°F DB / 43°F WB |
Electrical:
Power Supply (V¹/Hz/Ø) |
208-230/60/1 |
Rated Amps (A) |
0.4 |
Piping:
Installed Liquid Pipe (in., O.D.) |
ø1/4 |
Installed Vapor Pipe (in., O.D.) |
ø3/8 |
Liquid Connection (in., O.D.) |
ø1/4 |
Vapor Connection (in., O.D.) |
ø3/8 |
Drain (in., O.D. / I.D.) |
27/32 , 5/8 |
Temperature Sensor |
Thermistor |
Controls Features:
• 4-Way auto swing |
• Jet cool/Jet heat |
• 24-Hour on/o timer |
• 3M Micro Dust Filter |
• Auto operation |
• Self-cleaning indoor coil |
• Auto restart |
• Sleep mode |
• Chaos wind |
• Condensate sensor connection |
• Inverter (variable speed fan) |
• Built-in Wi-Fi via Smart ThinQ app |
Entering Mixed Air:
Cooling (°F DB) |
57 ~ 77 |
Heating (°F WB) |
59 ~ 81 |
|
|
Unit Data:
Refrigerant Type |
R410A |
Refrigerant Control |
EEV |
SoundPressure(H/M/L)(±3dB[A])2 |
35 / 31 / 26 |
Primary Filter |
Washable Pre-filter |
Secondard Filter |
3M Micro Dust |
Net Weight (lbs.) |
18.3 |
Shipping Weight (lbs.) |
23.4 |
|
|
Fan:
Type |
Cross Flow |
Quantity |
1 |
Motor/Drive |
BrushlessDigitallyControlled/Direct |
Air Flow H/M/L (CFM) |
254 / 204 / 148 |
|
|
Notes:
1.Acceptable operating voltage: 187V-253V.
2.Sound Pressure levels are tested in an anechoic chamber under ISO Standard 3745.
3.See Engineering Manual for sensible and latent capacities.
4.All communication / connection (power) cable from the outdoor unit to the indoor unit is field supplied and must be a minimum of four-conductor, 18 AWG, stranded, shielded or unshielded (if shielded, it must be grounded to the chassis of the outdoor unit only), and must comply with applicable local and national codes.
5.Power wiring cable size must comply with the applicable local and national code.
6.The indoor unit comes with a dry helium charge.
7.Corresponding refrigerant piping length is in accordance with standard length of each outdoor unit and the level difference is 0 ft. All capacities are net with a combination ratio between 95 - 105%.
8.Must follow installation instructions in the applicable LG installation manual.
Included Accessories:
• Wireless Remote Controller — AKB74955602
Optional Accessories:
MultiSITE™ CRC1 - PREMTBVC0
MultiSITE CRC1+ - PREMTBVC1
Dry Contact - PDRYCB300
For a complete list of available accessories, contact your LG representative. |
SB_MultiF_WallMount_HiEff_IDU_LMN079HVT_2018_03_20_064546 |
||
For continual product development, LG reserves the right to change specifications without notice. |
|||
|
Page 1 of 2 |
||
© LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG Life’s Good” is a registered trademark of LG Corp. /www.lghvac.com |