IMPORTANT: Please read entire instructions before
installing the Electronic Air Cleaner.
CONTENTS
SAFETY CONSIDERATIONS 2
WHAT THE ELECTRONIC AIR CLEANER DOES 2
BENEFITS 2
HOW IT WORKS 2
MAJOR COMPONENTS 3
INSTALLATION 3-4
Mounting 3
Wiring 4
OPERATION & MAINTENANCE 4
Operation Check 4
Maintenance Schedule 4
Cleaning 4
SERVICE 5-7
Testing For High Voltage At Power Board 5
Measuring High Voltage At Power Board 5
Replacing A Performance Light 5
Replacing A Power Board 5
Testing The 24 V Transformer 6
Replacing The 24 V Transformer 6
Setting Voltage Of Power Board 6
Setting Approximate Voltage Without High Voltage Meter 6
Testing For Voltage at The Cell 6
Testing Cell For Bad Contacts 7
Testing Cell With An Ohmmeter 7
Replacing A Tungsten Wire 7
Replacing A Fan Motor 7
REMOTE SWITCH CONTROL 7
Electrical Schematic 8
TROUBLESHOOTING GUIDE 9
Exploded View 10
Parts List 10
Technical Data and Dimensions 11
WARRANTY 12
Certified for shock and electrical fire hazard only.
SAFETY CONSIDERATIONS
Read and follow instructions carefully. Follow all local
electrical codes during installation. All wiring must
conform to local and national electrical codes. Improper
wiring or installation may damage the Air Cleaner.
Understand the signal words WARNING and
CAUTION which are present in the Installation, Operation
& Service Instructions.
WARNING and CAUTION signifies a hazard which
could result in property damage, personal injury or death.
Installation and servicing of Electronic Air Cleaners
can be hazardous. Only trained and qualified service
personnel should install, repair, or service Electronic
Air Cleaners.
Untrained personnel can perform the basic
maintenance functions of cleaning and replacing
filters.
When working on air cleaning equipment, observe
precautions in the manual, labels attached to the unit,
and other safety precautions that may apply. Follow
all safety codes. Wear safety glasses and work
gloves.
WHAT THE ELECTRONIC AIR CLEANER DOES
Your High Efficiency Electronic Air Cleaner has been
designed to remove tobacco smoke particles, cooking
smoke and grease, atmospheric dust, coal dust,
insecticide dust, mites, pollen, mold spores, fungi,
bacteria, viruses and more down to 0.01 micron (0.01
micron = 1/2,540,000 of an inch).
BENEFITS
Helps clear up a smokey environment quickly, so
customers can dine more comfortably.
Helps employees reduce suffering from irritated eyes,
nasal congestion and respiratory problems that lead
to absenteeism.
Helps prevent damaging black and greasy particles
from staining ceilings, walls and furnishings, reducing
the amount of housekeeping and redecorating costs.
Helps to lower energy bills by recycling air rather than
exhausting expensive heated or cooled air.
HOW IT WORKS
This Air Cleaner works on the principle of
"Electrostatic Precipitation". Millions of airborne pollutants
are drawn through the intake grill on the bottom of the Air
Cleaner and first pass through a Prefilter which removes
all large visible particles such as lint. Next, smaller
particles move to a two-stage electrostatic Collecting Cell
where they are given a powerful positive charge by the
ionizing wires. Charged particles then move into the
collecting area where they are attracted to a series of
grounded plates. Pollutants are held in this section like a
magnet until washed away during cleaning. Clean air is
then dispersed from the side grills in four directions
allowing superior air flow circulation.
1 DirtyAir
1 Dirty Air
2 Prefilter
2 Prefilter
3 Charging
3 Charging
Section
Section
4 CollectingCell
4 Collecting Cell
Plates
Plates
5 CleanAir
5 Clean Air
WARNING
Before beginning any installation or modification, be
certain that the main line electrical disconnect switch is
in OFF position. Electric shock could result. Tag
disconnect switch with suitable warning labels.
2
2
Fig. 1 — Electrostatic Precipitation
Fig. 1 —Electrostatic Precipitation
The Air Cleaner
creates a circular air
flow pattern which
never allows air to
rest at the ceiling.
Fig. 2 — Coanda Air Flow
MAJOR COMPONENTS
Description
The Electronic Air Cleaner is approximately 24 x 28 x
15 in (61 x 71 x 38 cm) with 6 in (15.2 cm) of the unit
above the ceiling. The cover and exhaust grill which
remain below the ceiling are hinged to allow access to the
cell and power board. The unit is rated at 700 CFM (1190
m3/hr) on the highest speed setting.
Cabinet
The cabinet is constructed of 20 gauge steel. The
external parts have a tough powder-coated, scratchresistant finish. Access to the collecting cell, power box
and prefilter is made by releasing the latches of the cover
and allowing it to swing down.
The cover is interlocked to cut power to the unit when
opened.
Prefilter
The washable prefilter measuring 12.5 x 20 in (31.75
x 50.8 cm) is constructed of multi-layers of aluminum
mesh for maximum filtration of large particles.
Collecting Cell
The dual voltage collecting cell is constructed of
heavy gauge aluminum to resist rust and damage. The
first stage, the ionizing section, is charged at
Blower and motor are
hidden above ceiling tiles
for space conservation.
Advantageous for low
ceiling applications where
a larger unit would be
obstructive.
Hinged cover provides
convenient access to grill,
prefilter, collecting cell and
electrical compartment.
Safety interlock cuts power
when cover is opened.
Rear hinges permit smooth
release of cover for easy
installation.
Removable intake grill for
easy cleaning.
approximately 7500 VDC. The collecting plates are
alternately grounded and charged at 5000 VDC. The
arrow on the cells indicates the direction of air flow which
must point up towards the fan motor.
Motor and Fan Blade
The motor is 1/33 HP, 1050 RPM, 3-speed, controlled
by a 3-position slide switch. The motor is thermally
protected. The fan blade is 14 in (35.5 cm) with a 20o
pitch.
Electrical Compartment
The removable power box contains the speed control,
system switch, high voltage power board, and
performance indicator light.
The interlock switch is located in the cabinet
body near the wiring compartment.
INSTALLATION
1. Read instructions carefully. Failure to do so may
result in product damage or injury.
2. Make sure the sizing is correct for your application.
3. Installation should be done by a knowledgeable
technician.
4. After installation, check out operation as provided in
these instructions.
Mounting
1. Remove the unit from the box and lay the unit on its
back, grill side up.
2. Release the grill by pushing the levers, located in the
exhaust grill, toward each other and lift up.
4. Remove the ‘S’ hook from each chain, tilt cover up
until the cover releases from the back hinges.
5. Remove the cell and prefilter from the unit.
6. Holes are provided in the cabinet to accommodate
5/16 in (8 mm) threaded rod. Threaded rod can be
attached to the angle iron which is laid across the
joists, by drilling holes through these supports. Pass
threaded rod up through the supports and secure with
two nuts and washers. This will allow adjustment of
Heavy duty collecting
cell captures airborne
pollutants and simply
washes clean.
Washable, aluminum
mesh prefilter catches
lint and large particles
before they enter
collecting cell.
3-speed fan control
(not shown) allows
adjustment of air flow
to activity level in room.
Fig. 3— Components
3
the unit so that the flange is flush with the underside
of the ceiling.
Leave enough room around the Air Cleaner for
removal of collecting cell and prefilter.
7. Replace the cell, prefilter and cover. Hook up the
safety chain to the cover.
Do not hang the unit with chain only. This will not
give the unit the necessary stability when removing
the cells or servicing the unit.
Wiring
WARNING
The frequency of cleaning will vary from one environment
to another. The following is an average wash cycle:
Stores, Offices, Computer & Conference Rooms = 4
Weeks
Cafeterias, Restaurants, Lounges = 3-4 Weeks
Bars, Bingo halls = 1-3 Weeks
The unit should be checked on a regular basis to
determine the frequency of cleaning required in each
location and a cleaning schedule established.
Cleaning
Electrical shock can cause injury or death. Be certain
main line disconnect switch is off before wiring.
All wiring must comply with applicable codes and
standards. See unit rating label for correct voltage and
amperage.
1. Two knockouts are provided, one on top and one on
the side of the unit, adjacent to the wiring
compartment. For convenience, a wall switch may be
installed near the Air Cleaner, in series with the
power source, to turn the unit on and off.
2. Remove the cover of the wiring compartment to
locate the input leads and ground stud. The Air
Cleaner must be grounded for proper operation and
safety.
3. Once the unit is mounted and wired, the cover can be
replaced on the hinge and the chain replaced on the
"S" hooks. Close the cover by sliding the levers
toward the center and pushing the cover up into
place. Release levers to lock the cover into place.
For information on wiring the remote switch
control see page 7.
OPERATION & MAINTENANCE
Operation Check
1. With the cell and prefilter in place and the cover
closed, turn the system switch ON.
2. Adjust the fan speed with the slide switch. Insure the
unit functions on all speeds.
3. The performance light should be ON, which indicates
the power board is functioning properly.
4. If the unit is not functioning properly see the
"Troubleshooting Guide"
When the Air Cleaner is new it may arc or periodically
make "snapping sounds". A slight odor of ozone may be
noticeable. The arcing and odor are due to rough edges
and burrs on the cell. These symptoms will disappear
during the first few weeks of normal operation. The ozone
levels are well below government standards for indoor air
concentration.
Maintenance Schedule
The collecting cell and prefilter must be cleaned on a
regular basis for the unit to function at its peak efficiency.
CAUTION
Make sure Air Cleaner switch is OFF before
performing any maintenance or removing any
components.
1. Turn off the system switch and wait 15 seconds for
high voltage to dissipate.
2. Open the cover and cell access door and remove
collecting cell and prefilter. Cell plates are sharp. Handle with care.
3. Place cell in tub and spray completely with DAX
Detergent, allowing detergent to run down both sides
of plates and ionizing wires. Let sit for 5 minutes.
Rinse cell well with hot water (140ºF / 60ºC
maximum). Repeat washing process if necessary.
4. If dirt or nicotine remains on plates, let cell soak in hot
soapy water for 30 minutes. Never use any
instrument to clean the cell, as this may damage
the ionizing wires or bend cell plates.
5. Spray prefilter with DAX Detergent and rinse well.
6. To dry cell, tilt on 45º angle against wall with the
arrow pointing sideways. Allow to dry completely for
10-24 hours. Place in sunlight for faster drying time.
7. When the cell and prefilter are dry, place them back
into the unit. The arrow on the cell points up. The red
fiberboard on the cell should line up with the contacts
in the cabinet. Close door and cover. If the cell arcs
when the switch is turned on or if the performance
light does not come on, then the cell may be still wet.
Allow more time for drying.
CAUTION
Damage to cell may occur if improperly handled or
washed. Do not wash cell in a dishwasher. Never
use any object to clean between the cell plates, as this
may cause damage to plates or ionizing wires. Never
place cell in oven to dry. The edges of the cell may be
sharp - handle with care.
The use of DAX Detergent is strongly recommended
for cleaning as it is a heavy-duty solution used expressly
for removal of accumulated pollutants on cell plates. If
used as directed, DAX will not harm aluminum or steel.
Any problem arising out of the use of another cleaning
agent will void the warranty. Do not use detergents that