Specifications |
Visit us online at |
|
www.getransportation.com |
Power Requirements |
|
Voltage range: |
|
10 to 14 VDC, 12 volts nominal |
|
Current draw: |
|
1.3 amps min. |
|
3.5 amps max. |
|
Maximum ripple: |
|
0.5 VAC PP |
|
Operating Temperature |
|
Minimum: -40°F (-40°C) |
|
Maximum: +160°F (+71°C) |
|
Surge Protection |
|
External air gap arrester (MDSA) |
|
Transmitter |
|
Track voltage: |
|
.35 volt RMS max. |
|
.125 volt RMS min. |
|
Frequency stability: ± .05% |
|
Phase stability: ± 1° |
|
Relay Drive |
|
12 VDC nominal, 250 to 1000 ohms |
|
Frequency Range |
|
All standard motion detector channels |
|
Dimensions |
|
PMD-3: |
|
Height: 14.6 in (370.8 mm) |
|
Width: 11 in (279.4 mm) |
|
Depth: 10.75 in (273.1 mm) |
|
PMD-3R: |
|
Height: 14.6 in (370.8 mm) |
|
Width: 19.25 in (489 mm) |
|
Depth: 10.75 in (273.1 mm) |
|
Weight |
|
PMD-3: 13 pounds (5.9 kg) |
|
PMD-3R: 22 pounds (9.98 kg) |
|
doc20050-B
GE
Transportation
The Phase Motion Detector PMD-3 monitors train approach directions from 240 to 7,500 feet (2,286 meters), activating warning signals at the specified pre-set distance.
The PMD-3 shares module compatibility with the
GE - Transportation HXP-3 crossing processor’s advanced microprocessor technology. This helps improve the economy of the PMD-3’s long-term maintenance, while its design flexibility helps reduce total installation expense and training cost.
The PMD-3 retains all the features that made earlier PMD models easy to set up and count on. This latest iteration provides advanced operating functionality and recording options. It offers enhanced rusty rail performance and is compatible with high-current cab signals.
The PMD-3 is available in two model configurations:
The PMD-3 provides stand-alone operation for single-track applications.
The PMD-3R is furnished with built-in redundancy for single-track applications.
Phase Motion Detector PMD-3
Advanced Crossing Warning Activation