MCE3064SS, MCF3064SS, MCE3130SS Magneto-Optical Disk Drives
Installation Guide
Installationsanleitung
Guide d'installation
COPYRIGHT FUJITSU LIMITED |
|
SEPT. 1999 |
C156-E117-02XA |
This guide is prepared to instruct the user on the switch and jumper settings in the MCE3064SS/MCF3064SS/MCE3130SS when you install your MCE3064SS/MCF3064SS/MCE3130SS.
Note; Factory default settings are marked with .
Layout of PCA |
SCSI ID Setting |
|
Table 1 |
|||
|
SCSI ID |
SW1-01 |
SW1-02 |
SW1-03 |
||
|
0 |
|
Off |
|
Off |
Off |
|
1 |
|
Off |
|
Off |
On |
|
2 |
|
Off |
|
On |
Off |
|
3 |
|
Off |
|
On |
On |
|
4 |
|
On |
|
Off |
Off |
|
5 |
|
On |
|
Off |
On |
|
6 |
|
On |
|
On |
Off |
|
7 |
|
On |
|
On |
On |
SW1 AND CNH2 SETTINGS
Switch 1 sets the SCSI ID and some drive functions and CNH2 sets additional drive functions.
SW1
Key# |
Function |
Key on |
|
Key off |
|
01 |
|
———— |
———— |
|
|
02 |
SCSI ID (see table 1 above) |
|
|||
03 |
|
|
|
|
|
04 |
SCSI data bus parity check |
Enabled |
|
Disabled |
|
05 |
Write cache mode |
Enabled |
|
Disabled |
|
06 |
Device type mode |
MO |
|
Fixed Disk |
|
07 |
Spindle automatic stop mode |
Enabled |
|
Disabled |
|
08 |
Factory test (Not to be set by user) |
Enabled |
|
Disabled |
|
CNH1 (TERMINATING POWER AND SCSI TERMINATION)
Terminal CNH1 uses shorting bars to set the power source and to enable or disable SCSI termination.
Pin# |
Function |
Short |
Open |
1–2 |
Power supplied by |
Supplied |
Not |
|
drive |
|
supplied |
3–4 |
Power supplied by |
Supplied |
Not |
|
host controller |
|
supplied |
5–6 |
SCSI termination |
Enabled |
Disabled |
|
enabled |
|
|
Power supplied by |
1–2 |
3–4 |
Drive |
Short |
Open |
Host controller |
Open |
Short |
Drive and Host |
Short |
Short |
controller |
|
|
CNH2 (EXTERNAL SWITCH |
|
|
|
||
SETTING) |
|
|
|
1 |
|
|
|
|
|
|
2 |
|
|
|
|
|
3 |
Pin# |
Function |
Open |
Short |
|
|
1 |
Cartridge-in detection |
— |
— |
|
4 |
|
|
||||
2 |
SCSI ID 4 |
— |
— |
|
5 |
3 |
LED source (+5 V) |
— |
— |
|
6 |
4 |
SCSI ID2 |
— |
— |
|
7 |
5 |
LED source (–) |
— |
— |
|
8 |
6 |
SCSI ID1 |
— |
— |
|
9 |
7 |
Signal to eject cartridge |
— |
— |
|
|
|
10 |
||||
8 |
Ground |
— |
— |
|
|
|
|
||||
9 |
Device type mode |
Fixed disk |
MO |
|
11 |
|
|
||||
10 |
SCAM mode |
Disabled |
Enabled |
|
12 |
11 |
Write verify mode |
Enabled |
Disabled |
|
13 |
12 |
Ground |
— |
— |
|
14 |
13 |
Macintosh mode |
Disabled |
Enabled |
|
15 |
14 |
SCSI type 0 |
SCSI 2 |
SCSI 1 |
|
16 |
15 |
Terminating resister mode |
Disabled |
Enabled |
|
|
|
|
||||
|
|
|
|
|
|
16 |
Ground |
— |
— |
|
|
OPERATOR PANEL
TTL-IC |
0V |
Note: The cable length must not exceed 30cm.
Device Driver
You need to install Fujitsu's device driver to avoid the 2KB sector problem in Windows9x and the OS-timeout-problem in Windows9x and NT3.51/4.0.
MCE3064SS/MCF3064SS/MCE3130SS HANDLING AND MAINTENANCE
Orientation
The drive can be installed in one of three orientations; either PCA up or on either side edge.
Ejecting cartridge
Cartridges can be ejected by pressing the eject key or by a SCSI eject command. Never eject a cartridge mechanically except in an emergency.
WORLD WIDE WEB SITE
Cleaning lens and media recommendation
Clean the lens on the drive head and the disk media once every three months. More frequent cleaning may be required in a dirty environment. Use the Fujitsu head cleaning kit and media cleaning kit. Head cleaning kits from other vendors will not work.
Corporate |
http://www.fujitsu.co.jp/ |
SINGAPORE |
http://www.fujitsu-computers.com.sg/ |
||
USA |
http://www.fcpa.com/ |
CANADA |
http://www.fujitsu.ca/ |
||
EUROPE |
http://www.fujitsu-europe.com/ |
AUSTRALIA |
http://www.fujitsu.com.au/ |
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|