Follett U150NR4A, U150N, U150NR5A, U150NR5W, U150NR8A Operation, Service And Parts Manual

...
0 (0)
206563R02
801 Church Lane • PO Box D, Easton, PA 18044 Toll free (800) 523-9361 • (610) 252-7301 Fax (610) 250-0696 • www.follettice.com
Operation, Service and Parts Manual
U150 Series
Ice Dispensers
U150
U150NR4A/W U150NR5A/W
U150NR8A/W
U150NR10A/W
U150R4A/W
U150R5A/W U150BR4A/W U150BR5A/W
U150R8A/W
U150R10A/W
U150BR8A/W
U150B10A/W
Order parts online www.follettice.com
Welcome to Follett
Follett ice dispensers enjoy a well-deserved reputation for excellent performance, long-term reliability and outstanding after-the-sale support. To ensure that this dispenser delivers that same degree of service, we ask that you take a moment to review this manual before using the dispenser. Should you have any questions or require technical help at any point, please call our technical service group toll free at (800)523-9361 or (610)252-7301.
Before you begin
Check your paperwork to determine which model you have. Following is an explanation of the different model numbers in the U150 series.
Electrical specifications
Standard electrical - 115V, 60Hz, 1 phase
Separate circuit and disconnects required for each icemaker and dispenser. Max. fuse size 20 amps per circuit
Manual load models
U150N – dispenser 2.4 amps U150 – dispenser 2.4 amps U150B – dispenser 4.4 amps
Models with R4A/W Icemaker
U150R4A/W, U150NR4A/W – 13.4 amps U150BR4A/W – 15.4 amps U150R8A/W, U150NR8A/W – 24.4 amps U150BR8A/W – 26.4 amps
Models with R5A/W Icemaker
U150R5A/W, U150NR5A/W – Icemaker 11.0 amps, dispenser 2.4
amps U150BR5A/W – Icemaker 11.0 amps, dispenser 4.4 amps U150R10A/W, U150NR10A/W – (2) icemakers 11.0 amps each,
dispenser 2.4 amps U150B10A/W – (2) icemakers 11.0 amps each, dispenser 4.4
amps
• Equipment ground required.
• Separate circuit and disconnects required for each icemaker and dispenser. Disconnects suggested within 10 ft (3m) of dispenser and icemaker(s).
U150BR5A
Condenser type – A = air-cooled, W = water-cooled
Remote icemaker(s) capacity and refrigerant – 4 = 400 lbs (181kg)/day, R12; 5 = 400 lbs (181kg)/day, R22; 8 = 800 lbs (363kg)/day, R12; 10 = 800 lbs (363kg)/day, R22
B = with integral beverage cooling. Absence of a B = no integral beverage cooling. N = no beverage rail or valves.
Approximate storage capacity in lbs
Dispenser configuration – U = undercounter
Important cautions
• Storage area of dispenser contains mechanical, moving parts. Keep hands and arms clear of this area at all times. If access to this area is required, power to unit must be disconnected first.
• Follett manual load units can accommodate most cube/cubelet ices up to 1" square, or Follett compressed nugget ice. Crushed, flake, bagged, nugget or congealed ice cannot be used. Use of these ices can jam dispenser and void warranty. Separate any “waffle-like” sections of cubes before adding to dispenser. If you have any questions concerning your ice type, please call Follett’s customer service group toll free at (800) 523-9361 or (888) 2-FOLLETT or (610) 252-7301.
• Follett recommends use of an activated carbon filter for units equipped with icemakers
• Ice is slippery. Maintain counters and floors around dispenser in a clean and ice-free condition.
• Ice is food. Follow recommended cleaning instructions to maintain cleanliness of delivered ice.
Alternate electrical - 230V, 50Hz, 1 phase Separate circuit and disconnects required for each icemaker and dispenser. Max. fuse size 15 amps per circuit
Manual load models
U150N – dispenser 1.7 amps U150 – dispenser 1.7 amps U150B – dispenser 2.2 amps
Models with R4A/W Icemaker
U150R4A/W, U150NR4A/W – 7.7 amps U150BR4A/W – 8.2 amps U150R8A/W, U150NR8A/W – 13.7 amps U150BR8A/W – 14.2 amps
Models with R5A/W Icemaker
U150R5A/W, U150NR5A/W – Icemaker 6.0 amps,
dispenser 1.7 amps U150BR5A/W – Icemaker 6.0 amps, dispenser 2.2 amps U150R10A/W, U150NR10A/W – (2) icemakers 6.0 amps
each, dispenser 1.7 amps U150B10A/W – (2) icemakers 6.0 amps each, dispenser 2.2
amps
2
Plumbing
Dispenser – all models
3/4" female PVC slip joint dispenser drain 3/4" male slip joint to 3/4" MPT PVC adapter provided
Note: Drains to be hard piped and insulated, with1/4" per foot (6mm per 30.4cm) min. slope.
Icemaker – automatic load models only
1/4" FPT water in 1/2" MPT drain 3/8" FPT condenser inlet (water-cooled condenser only) 1/2" FPT condenser drain (water-cooled condenser only)
Note: Water disconnect within 10 feet (3m) of icemaker(s) is suggested for automatic load units.
Beverage connections - Models with beverage valves only
1/4" syrup and 3/8" carbonated water pigtails.
How the dispenser works
Follett’s U150 series ice dispensers are available in manual load configurations (using ice from another source) or automatic load configurations, fed from one or two Follett 400 lb (181kg)/day remote icemakers.
In all models, ice is stored below the counter in the dispenser storage area. When the dispense lever or button is pushed, the dispense motor is activated. This causes the wheel assembly in the storage area to turn, moving ice to the vertical auger assembly, which carries ice up to the dispense chute where it drops by gravity into the container.
In automatic load models, ice is manufactured in either one or two Follett remote icemakers. These icemakers may be located up to 20 feet (3m) away from the dispenser. As water freezes to the inside walls of the icemaker evaporator, a rotating stainless steel auger removes ice and carries it to the top of the evaporator assembly where it is compressed and extruded through an outlet port. The extruded ice is then pushed through the tube to the storage compartment of the dispenser. A level fill circuit maximizes fill in the storage area by rotating the wheel at intervals until the bin is completely filled. When the bin is filled, a bin stat shuts the icemaker off to avoid overfilling of the bin. U150 dispensers equipped with R4A/W (R12 refrigerant) icemakers have a safety thermostat that prevents the icemaker from restarting for 15 to 30 minutes after the bin stat has shut the icemaker down. In U150 dispensers with R5A/W (R22 refrigerant) icemakers, the icemaker will restart after 15 to 20 minutes if the bin is calling for ice.
From Serial Number 40600 and up, models with integral ice-waterbath beverage cooling are equipped with a waterbath timer circuit that activates the waterbath pump 1 minute on and 10 minutes off to ensure optimal beverage cooling.
To start-up and operate dispenser
1. Follow cleaning instructions in U150 Series Installation Manual before operating dispenser.
2. Follow start-up instructions in U150 Series Installation Manual for beverage line hook-up instructions, initial loading of ice-waterbath beverage cooling system, manual loading restrictions and/or automatic load start-up requirements.
3. Turn power and feed switches located inside beverage rail or ice tower to ON position.
4. For manual load models, remove front drain pan or rear lid and fill storage area with compatible ice.
5. For automatic fill models, turn icemaker (bin signal) switch(es) located inside beverage rail or ice tower to ON position and begin to make ice.
6. When dispenser has at least 6" (153mm) of ice in storage area, press PUSH FOR ICE lever or button to insure that dispenser is operating properly.
3
Periodic cleaning of dispenser
Caution: Do NOT run plastic parts (drain pan, dispense chute cover, dispense wheel) through a
dishwasher.
Solution A: Prepare a cleaning solution (200 ppm of available chlorine content) of Ecolab Mikro-chlor Cleaner or
equal chlorinated detergent. Solution temperature must be 75˚ to 125˚F (24˚ to 52˚C).
Solution B: Prepare a sanitizing solution (50 ppm of available chlorine content) of Ecolab Mikro-chlor Cleaner or
equal chlorinated detergent. Solution temperature must be 75˚ to 125˚F (24˚ to 52˚C).
Recommended daily cleaning of drain pan
1. Remove all debris from drain pan.
2. Pour 1 gallon (4L) hot water into drain pan to keep drain lines clear.
Recommended weekly cleaning
1. Remove drain pan and grille and wash with Solution A above. Rinse thoroughly.
2. On units with beverage valves, remove nozzles and diffusers from valves, soak for at least 10 minutes in cleaning Solution A, rinse, sanitize with Solution B and reinstall.
3. Pour a solution of one cup (8oz/237ml) household bleach mixed with one gallon (3.8L) hot water into drain pan to help prevent algae growth in drain lines.
Recommended quarterly cleaning (every 3 months)
Caution: Remove dispense switch from dispense chute before cleaning chute.
1. Turn power switch to OFF position.
2. Remove ice from storage area.
3. Remove dispense chute, chute cover, auger tube and auger (page 10).
4. Remove drain pan, grille, dispense wheel and waterbath cover plate (page 11).
5. Clean all components and bin storage area with Solution A, rinse thoroughly with clear water and sanitize with Solution B.
6. On units with beverage valves, remove nozzles and diffusers from valves, soak for at least 10 minutes in cleaning Solution A, rinse, sanitize with Solution B and reinstall.
7. For units without integral beverage cooling, clean area below wheel and stainless cover plate with Solution A, rinse and sanitize with Solution B.
8. For models with integral ice-waterbath beverage cooling only:
• Lower drain tube found on utility connection side of dispenser and drain ice-waterbath
• Use a bottle brush to clean coils with Solution A, rinse and sanitize with Solution B
• Reposition waterbath drain line in UP position
• Pour 3.5 gallons (13L) Solution A into waterbath
• Turn power ON and tape dispense lever or dispense button back in “Dispense” position
• Allow pump to run for 2 minutes to clean pump and pump lines
• Turn power OFF and remove tape
• Drain bath and replace drain tube in UP position to avoid siphoning waterbath water
Putting unit back in service after quarterly cleaning
1. On units with integral beverage cooling, fill ice-waterbath with 3.5 gallons (13L) potable water.
2. Reassemble components.
3. For manual load units, fill unit with an approved ice (page 2).
4. For automatic load units with R4A/W (R12 refrigerant) icemakers, turn icemaker switch(es) and dispenser power switch to ON position and allow storage area to fill.
5. For automatic load units with R5A/W (R22 refrigerant) icemakers, turn bin signal switch(es) and dispenser power switch to ON position and allow storage area to fill.
6. Push dispense button or lever to test that dispenser is functioning properly.
Quarterly cleaning of icemaker system
Units equipped with icemakers require cleaning of icemaker system at least every three months, and more often if local water conditions dictate. Failure to clean icemaker system will result in decreased performance and potential damage to icemaker. Refer to Icemaker Operation and Service Manual.
4
All manual load models before serial #40600
5
Automatic load models with R4A/W (R12) icemaker(s), no beverage cooling – Before serial #40600
UNITS WITH BEVERAGE COOLING ONLY
DRAIN PAN SWITCH
BLACK BLACK
BLACK
POWER SWITCH
POWER SUPPLY
BROW
LID SWITCH
YELLOW
N
BLACK
DISPENSE SWITCH
PURPLE
BLACK
24V TRANSPORMER
YELLOW
YELLOW
WATERBATH T-STAT
KEY SWITCH (OPTION)
AUGER
FEED SWITCH
WHITE
WHITE
M
YELLOW
WATERBATH PUMP
M
24V TO BEVERAGE VALVES
BLACK
WHEEL MOTOR
RED
WHITE
WHITE
M
BLUE
BLACK
POWER SWITCH
BLACK BLACK
T-STAT
POWER SUPPLY
BLACK
BROWN
24V TRANSPORMER
PURPLE
2
3
LEVEL FILL TIMER 18 MIN OFF 5 SEC ON
ICE SUPPLY SWITCH #1
LID SWITCH
BLACK #8
1
YELLOW
BLACK #10
DISPENSE SWITCH
7
9
YELLOW
4
1
6
3
DRAIN PAN SWITCH
BLACK #6
RED #2 RED #1
YELLOW
YELLOW #7
KEY SWITCH (OPTION)
WHITE
WHITE
AUGER
M
ORANGE
YELLOW
FEED SWITCH
WHITE
WHITE #4
TO ICEMAKER #1
RED
WHITE
24V TO BEVERAGE VALVES
WHEEL MOTOR
BLUE
WHITE
RED #2
ICE SUPPLY SWITCH #2
DUAL FEED RELAY (OPTIONAL)
RED #2
TO ICEMAKER #2
Wiring Diagram – Automatic load models with R5A/W (R22 refrigerant) icemaker (s), no beverage cooling – Before serial # 40600
6
POWER SUPPLY
KEY SWITCH
BLACK
BROWN
24V TRANSPORMER
(OPTION)
WHITE
24V TO BEVERAGE VALVES
WHITE
BLACK
POWER SWITCH
DRAIN PAN SWITCH
BLACK BLACK
BLACK #6
3
LEVEL FILL TIMER 18 MIN OFF 5 SEC ON
ICE SUPPLY
T-STAT
SWITCH #1
RED #2 RED #1
ICE SUPPLY
RED #2
SWITCH #2
PURPLE
2
1
LID SWITCH
BLACK #8
YELLOW
BLACK #10
RED #2
DISPENSE SWITCH
7
9
YELLOW
4
1
YELLOW
6
YELLOW #7
3
AUGER
M
ORANGE
YELLOW
FEED SWITCH
WHITE
WHITE #4
TO ICEMAKER #1 BIN LEVEL CONTROL
TO ICEMAKER #2 BIN LEVEL CONTROL
WHITE
RED
BLUE
WHEEL MOTOR
WHITE
7
Automatic load models with R4A/W (R12) icemaker(s), with beverage cooling – Before serial #40600
POWER SUPPLY
KEY SWITCH
BLACK
BROWN
24V TRANSPORMER
(OPTION)
WHITE
24V TO BEVERAGE VALVES
WHITE
BLACK
POWER SWITCH
DRAIN PAN SWITCH
BLACK BLACK
PURPLE
3
LEVEL FILL TIMER 18 MIN OFF 5 SEC ON
ICE SUPPLY
T-STAT
SWITCH #1
RED #2 RED #1
BATH T-STAT
BLACK
2
LID SWITCH
BLACK #8
1
DISPENSE
YELLOW
PURPLE WHITE
BLACK #6
SWITCH
BLACK #10
PUMP
M
7
9
YELLOW
4
1
6
YELLOW #7
3
YELLOW
AUGER
M
ORANGE
YELLOW
FEED SWITCH
WHITE
WHITE #4
TO ICEMAKER #1
RED
WHITE
BLUE
WHEEL MOTOR
WHITE
RED #2
ICE SUPPLY SWITCH #2
RED #2
DUAL FEED RELAY (OPTIONAL)
TO ICEMAKER #2
Loading...