Florabest FRWS 9 A1 User Manual [sl]

DOWNPIPE RAINWATER DIVERSION SET FRWS 9 A1
DOWNPIPE RAINWATER DIVERSION SET
Assembly Instructions
REGENSAMMLER-SET
Montageanleitung
IAN 73211
Navodila za montažo
Before reading, unfold both pages containing illustrations and familiarise yourself with all functions of the device.
Pred branjem obe strani s slikami odprite navzven in se nato seznanite z vsemi funkcijami naprave.
Klappen Sie vor dem Lesen die beiden Seiten mit den Abbildungen aus und machen Sie sich anschließend mit allen Funktionen des Gerätes vertraut.
GB Assembly Instructions Page 1 SI Navodila za montažo Stran 7 DE / AT / CH Montageanleitung Seite 13
Index
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Intended use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Items supplied / Parts description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Downpipe and rainwater barrel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Rainwater collector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Connection to the rainwater barrel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Summer and winter operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Importer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
GB
FRWS 9 A1
1
GB
Introduction
Congratulations! With your purchase you have decided in favour of a quality product. Familiarise yourself with the product before installation and before taking it into use for the fi rst time. In this regard, please read the following assembly instructions attentively. Use this appliance only as described and only for the specifi ed areas of applica­tion. Retain these instructions for future reference. In addition, pass these documents on, together with the product, to any future owner.
Intended use
This rainwater collector is intended for installation in a vertical downpipe. There it collects rainwater fl owing from the roof water and directs it to a rainwater barrel. It can be used for roof areas of up to about 80 m² in size. This rainwater collector can be installed on standard rainwater downpipes made of metal or plastic with diameters from 70 - 110 mm. The rainwater collector is intended solely for domestic use. This appliance is not intended for any other use or for uses beyond those detailed. Claims of any kind for damage resulting from unintended use will not be accepted. The user alone bears liability.
Items supplied / Parts description
Figure A:
1 Crown drill bit 1 Flange for downpipe sizes 70-80 mm 1 Flange for downpipe sizes 90-110 mm 2 Flange gaskets 1 Rubber seal for the hole in the rainwater barrel (DN 19/32) 1 Clamping device 1 Rainwater collector with control valve and fi lter insert 1 Connection hose
Figure B:
with overfl ow protection
with sommer-/winter operation Suitable for all vertical downpipes DN 70 - 110 mm
2
FRWS 9 A1
Figure C (Working materials needed):
Protective gloves
Protective goggles
Pencil
Spirit level
Drill
Detergent
Carpet knife/fi le
Assembly
Downpipe and rainwater barrel
IMPORTANT
The borehole in the downpipe is also the maximum fi lling height of the
rainwater barrel.
Be aware of unevenness in the terrain, so as to prevent subsequent over-
fl ows from the rainwater barrel. It is best to place the rainwater barrel at its fi nal intended location and to then transfer the marking for the max. fi lling level onto the downpipe with a spirit level.
1. Using a spirit level and a pencil, mark the hole positions onto the rainwater barrel and downpipe (see Figure D).
GB
FRWS 9 A1
WARNING - RISK OF INJURY
When drilling, be sure to wear personal protective equipment (goggles
and gloves).
Exercise caution when handling the crown drill.Exercise caution when deburring with the carpet knife. The blade is very sharp!
2. Drill the hole in the down pipe with the crown drill care to drill with light pressure only, especially in sheet metal downpipes. Then deburr the drillhole with a suitable tool, such as a carpet knife for plastic downpipes or a fi le with sheetmetal downpipes.
3. Now drill the hole in the rainwater barrel with the crown drill and then deburr the drillhole (see Figure F).
(see Figure E). Take