DOWNPIPE RAINWATER DIVERSION SET FRWS 9 A1
DOWNPIPE RAINWATER
DIVERSION SET
Assembly Instructions
REGENSAMMLER-SET
Montageanleitung
REGNVANDSSAMLER-SÆT
Monteringsvejledning
IAN 73211
Before reading, unfold both pages containing illustrations and familiarise yourself with all functions of the
device.
Før du læser, vend begge sidene med billeder frem og bliv bekendt med alle apparatets funktioner.
Klappen Sie vor dem Lesen die beiden Seiten mit den Abbildungen aus und machen Sie sich anschließend
mit allen Funktionen des Gerätes vertraut.
GB / IE Assembly Instructions Page 1
DK Monteringsvejledning Side 7
DE / AT / CH Montageanleitung Seite 13
Index
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Intended use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Items supplied / Parts description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Downpipe and rainwater barrel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Rainwater collector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Connection to the rainwater barrel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Summer and winter operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Importer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
GB
IE
FRWS 9 A1
1
GB
IE
Introduction
Congratulations!
With your purchase you have decided in favour of a quality product. Familiarise
yourself with the product before installation and before taking it into use for the
fi rst time. In this regard, please read the following assembly instructions attentively.
Use this appliance only as described and only for the specifi ed areas of application. Retain these instructions for future reference. In addition, pass these documents
on, together with the product, to any future owner.
Intended use
This rainwater collector is intended for installation in a vertical downpipe. There it
collects rainwater fl owing from the roof water and directs it to a rainwater barrel.
It can be used for roof areas of up to about 80 m² in size. This rainwater collector
can be installed on standard rainwater downpipes made of metal or plastic with
diameters from 70 - 110 mm. The rainwater collector is intended solely for domestic
use. This appliance is not intended for any other use or for uses beyond those
detailed. Claims of any kind for damage resulting from unintended use will
not be accepted. The user alone bears liability.
Items supplied / Parts description
Figure A:
1 Crown drill bit
1 Flange for downpipe sizes 70-80 mm
1 Flange for downpipe sizes 90-110 mm
2 Flange gaskets
1 Rubber seal for the hole in the rainwater barrel (DN 19/32)
1 Clamping device
1 Rainwater collector with control valve and fi lter insert
1 Connection hose
Figure B:
with overfl ow protection
with sommer-/winter operation
Suitable for all vertical downpipes DN 70 - 110 mm
2
FRWS 9 A1
Figure C (Working materials needed):
■ Protective gloves
■ Protective goggles
■ Pencil
■ Spirit level
■ Drill
■ Detergent
■ Carpet knife/fi le
Assembly
Downpipe and rainwater barrel
IMPORTANT
The borehole in the downpipe is also the maximum fi lling height of the
►
rainwater barrel.
► Be aware of unevenness in the terrain, so as to prevent subsequent over-
fl ows from the rainwater barrel. It is best to place the rainwater barrel at its
fi nal intended location and to then transfer the marking for the max. fi lling
level onto the downpipe with a spirit level.
1. Using a spirit level and a pencil, mark the hole positions onto the rainwater
barrel and downpipe (see Figure D).
GB
IE
FRWS 9 A1
WARNING - RISK OF INJURY
► When drilling, be sure to wear personal protective equipment (goggles
and gloves).
► Exercise caution when handling the crown drill.
► Exercise caution when deburring with the carpet knife. The blade is very sharp!
2. Drill the hole in the down pipe with the crown drill
care to drill with light pressure only, especially in sheet metal downpipes.
Then deburr the drillhole with a suitable tool, such as a carpet knife for
plastic downpipes or a fi le with sheetmetal downpipes.
3. Now drill the hole in the rainwater barrel with the crown drill and then
deburr the drillhole (see Figure F).
(see Figure E). Take
3