This manual was created with special care on the technical content and the correct
verbalisation. However, as a matter of principle Flintec GmbH will not take
responsibility for any damage caused by missing or wrong informations
FRD-100 BL Manual page 1 of 7
... the right weigh
1. SAFETY INFORMATION ................................................................... 2
NORMAL BEHAVIOUR......................................................................................... 5
STANDARD DATA PROTOCOL DESCRIPTION........................................................ 5
4. SERVICE AND CONTACT INFORMATION......................................... 7
1. Safety Information
All products of this series are developed, manufactured and tested in accordance with
the applicable industry safety standards. If these products are properly installed,
operated and maintained according to the applicable technical instructions, drawings
and specifications, no hazard exists in the normal and intended use of these products.
General Safety Guidelines
The following general safety guidelines apply to all Flintec - products:
All applicable safety and accident prevention recommendations must be
observed (VDE 0100 and VDE 0113).
All installation, start-up and maintenance work must be carried out by qualified
service personnel only.
An easily accessible power outlet must be located close by for devices equipped
with a main power cord and plug.
An easily accessible MAIN POWER ON/OFF switch must be provided for
equipment with permanent electrical connections.
FRD-100 BL Manual page 2 of 7
... the right weigh
2. Characteristics
DISPLAY
Character Height 100 mm
Number of digits 5
Resolution 7 segments plus colon and decimal point
Technology Transflective positive TN LCD
Backlight Yes; Amber LED
MECHANICAL
Size casing 540 mm x 169 mm x 35 mm (w x h x d) (w/o connector)
Size inc. bracket 550 mm x 180 mm x 58 mm (w x h x d) (w/o connector)
Materials Stainless Steel 316
Protection IP-65
Weight 4,5 kg net
Display Dimensions
ELECTRONICS
Interface field selectable/autosearch: RS-232, RS-485 and 20 mA TTY
Current Loop
Data Format 300-38400 Baud with 7 or 8 databits even, odd or no parity
(Default: 9600, 7, Even)
Power requirements 9V DC (without backlight) - 24V DC (with backlight)
(typically power consumption <=100 mA)
Connection Unterminated 4m cable
FRD-100 BL Manual page 3 of 7
... the right weigh
CABLE ASSIGNEMENT
Pink +V DC External Power Supply +
Grey GND External Power supply –
*Black A+ RS-485/422 Transciever
*Violet B- RS-485/422 Transciever
White TTY+ Input positive 20 mA
Brown TTY- Input negative 20 mA
Blue RxD RS232 Input from TxD of Host
Red/Blue
Red TxD
Green +O
RxD
GND
Yellow -O
RS232 Signal Ground
(Short it with GREY)
RS232 Output to RxD of Host
(Not needed for normal use)
+ Output
(Not needed for normal use)
- Output
(Short it with GREY)
* Note that RS-485 signals are deactivated internally to avoid picking up noise.
To activate RS485/422 you have to open the compartment on the back using Torx TX25 for the M4x10 screws, connect the Black and the Violet leads to terminals A+ and
B- respectively
3. Operation Notes
INSTALLATION NOTES
To comply with various safety and conformance rulings, the system must be properly
grounded. The Scoreboard itself needs to be connected to safety earth, and the
connector should be firmly mated and fixed by use of fixing screws.
When power is applied, the display should respond by a sequence of control messages
(see „Normal Behaviour“). After the short start-up formality, display is blanked. If this
sequence is missing, check power source and connections. The voltage present at the
pins on the Scoreboard D-sub should be stable between 8 and 28 Vdc.
FRD-100 BL Manual page 4 of 7
... the right weigh
NORMAL BEHAVIOUR
When power is applied, the Scoreboard will go through a sequence of initialisation. By
carefully looking at the display, you will be presented the following data:
888888 all segments are on, then off to verify correct operations
08.25 is the firmware version
A.00 is the address of the display (normally set to 00 if disabled)
C:9600 indicates the current baud rate setting
P: 20 Protocol number or other identification
After initialisation, the Scoreboard will blank with all decimal points activated. This is
the default 'waiting screen' indicating that it is awaiting a valid message.
The Display is set to “Autosearch” by standard. It will try to detect the connection and
data protocol settings by itself. This detection is shown on the screen and can take
some minutes. After the settings were found the display should show the incoming
data on screen. (e.g. the weight sent out by the indicator)
If the screen is still empty after 5 minutes, please deactivate everything, check again
the cables and the indicator interface settings and restart everything.
Note that reducing the voltage supplied below 20V will turn off backlight and reduce
current consumption. The operation will otherwise be as normal.
STANDARD DATA PROTOCOL DESCRIPTION
As a serial display, the message format handled is based on the parameter setting that
defines valid and essential data. The data displayed is replaced each time a valid new
message is received. The timeout function may auto blank the display after a preset
number of seconds.
There are a lot of predefined protocols stored in the Display. The autosearch will
automatically set the correct one (if existing) to fit the incoming Data
The following text only describes the factory default protocol.
Default Protocol
<STX>data<CR>
Where <STX>=ASCII 02d, <CR>=ASCII 13d. Data includes minus sign (-), decimal
point (represented by '.' or',') and leading blanks or zeros.
Addressing Control
<SOH> AA <STX>
Will select display AA (00 to 99). 00 will broadcast to all connected displays.
Addressing is used relatively seldom.
FRD-100 BL Manual page 5 of 7
... the right weigh
EC – Declaration of Conformity
The following named product:
is conform to the following european directives and standards:
EN55011, EN50082 (Part 1 and 2) and CENELEC EN 60742
Meckesheim, 1.3.2001
Flintec GmbH
Bemannsbruch 9
D-74909 Meckesheim
FRD-100 BL Display
Geschäftsführer
FRD-100 BL Manual page 6 of 7
Gerhard K. Adam
... the right weigh
4. SERVICE AND CONTACT INFORMATION
Flintec GmbH
Bemannsbruch 9
74909 Meckesheim
Germany
Tel.:+49 6226 9240 0
Fax :+49 6226 9240 99
http://www.flintec.com
FRD-100 BL Manual page 7 of 7
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.