ERD60
|
|
|
|
|
|
|
|
|
|
|
|
Revised |
|
|
|
|
60” Wide, |
|
|
PLANNING |
||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Epicure® Range |
1/2 |
GUIDE |
||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
06/25/08 |
|
|
|
|
|
|
|
|||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
28 1/2" (724mm) |
|
|
|
|
|
Handle |
|
|
|
warning |
|
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||
|
|
|
|
|
|
|
|
|
|
|
27" (686mm) |
|
|
|
|
Front Edge of Bullnose |
|
◊ |
Observe all governing codes and ordinances during |
|
||||||||
|
|
|
|
|
|
|
|
|
|
|
|
26" (660mm) |
|
|
|
|
|
|
Face of Control Panel/Oven Door |
|||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
planning and installation. Contact your local building |
|||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
24 3/8" (619mm) |
|
|
|
|
Rear of Control Panel/Oven Door |
|
||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
department for further information. |
|||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
◊ |
This appliance must be installed in accordance with the |
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
6” (152mm) Backguard |
||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
accompanying installation instructions. |
|||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1 9/16" (40mm)
When Backguard and Side Panels are
removed, the overall depth decreases
by 1" (25mm)
37”
(940mm) to
35 3/4" (908mm)
60" (1524mm)
Finished Side Panel
6" (152mm) Backguard
Accessory 3” (76mm) Side Panels
(Dacor Model No. AESP03)
erd/eGR30, erd60 overall dimensions side view
|
|
Power Cords |
|
Factory installed 3/4” regulators |
||
|
|
|
|
|
(1/2” supply ok) |
|
|
|
|
|
rear view |
|
|
|
|
|
|
|
|
|
|
|
Total |
|
|
|
|
Dacor® |
Dedicated Circuit* |
Connected |
|
Gas |
Manifold |
Min. Gas Supply |
Model No. |
Required |
Load |
|
Type |
Pressure |
Pressure |
ERD60 |
240 Vac, 4-wire, 60 Hz, |
4.1 kW |
|
Natural |
5” Water Column |
6” Water Column |
ERD60LP |
|
Liquid |
|
|
||
30 Amp (Breaker) X2 |
(21Amp) X2 |
|
10” Water Column |
11” Water Column |
||
|
|
Propane |
||||
|
|
|
|
|
|
*Two separate dedicated circuits are required, one for left and one for the right side of the range.
Electrical AND GAS Supply Requirements
NOTES:
1.Utilities may be located in the lower left corner of the adjacent right cabinet. (Recommended)
2.Contact your local building department to verify compliance with local code interpretation.
3.Two electrical circuits and gas supplies required.
Web: http://www.Dacor.com |
Specifications are subject to change without notice. |
5.7 |
Corporate Phone: 800-793-0093 |
See installation instructions for additional details. |