Catalyst 3750-X and 3560-X Switch
Hardware Installation Guide
May 2010
Americas Headquarters
Cisco Systems, Inc. 170 West Tasman Drive
San Jose, CA 95134-1706 USA http://www.cisco.com Tel: 408 526-4000
800 553-NETS (6387) Fax: 408 527-0883
Text Part Number: OL-19593-01
THE SPECIFICATIONS AND INFORMATION REGARDING THE PRODUCTS IN THIS MANUAL ARE SUBJECT TO CHANGE WITHOUT NOTICE. ALL STATEMENTS, INFORMATION, AND RECOMMENDATIONS IN THIS MANUAL ARE BELIEVED TO BE ACCURATE BUT ARE PRESENTED WITHOUT WARRANTY OF ANY KIND, EXPRESS OR IMPLIED. USERS MUST TAKE FULL RESPONSIBILITY FOR THEIR APPLICATION OF ANY PRODUCTS.
THE SOFTWARE LICENSE AND LIMITED WARRANTY FOR THE ACCOMPANYING PRODUCT ARE SET FORTH IN THE INFORMATION PACKET THAT SHIPPED WITH THE PRODUCT AND ARE INCORPORATED HEREIN BY THIS REFERENCE. IF YOU ARE UNABLE TO LOCATE THE SOFTWARE LICENSE OR LIMITED WARRANTY, CONTACT YOUR CISCO REPRESENTATIVE FOR A COPY.
The following information is for FCC compliance of Class A devices: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio-frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case users will be required to correct the interference at their own expense.
The following information is for FCC compliance of Class B devices: The equipment described in this manual generates and may radiate radio-frequency energy. If it is not installed in accordance with Cisco’s installation instructions, it may cause interference with radio and television reception. This equipment has been tested and found to comply with the limits for a Class B digital device in accordance with the specifications in part 15 of the FCC rules. These specifications are designed to provide reasonable protection against such interference in a residential installation. However, there is no guarantee that interference will not occur in a particular installation.
Modifying the equipment without Cisco’s written authorization may result in the equipment no longer complying with FCC requirements for Class A or Class B digital devices. In that event, your right to use the equipment may be limited by FCC regulations, and you may be required to correct any interference to radio or television communications at your own expense.
You can determine whether your equipment is causing interference by turning it off. If the interference stops, it was probably caused by the Cisco equipment or one of its peripheral devices. If the equipment causes interference to radio or television reception, try to correct the interference by using one or more of the following measures:
•Turn the television or radio antenna until the interference stops.
•Move the equipment to one side or the other of the television or radio.
•Move the equipment farther away from the television or radio.
•Plug the equipment into an outlet that is on a different circuit from the television or radio. (That is, make certain the equipment and the television or radio are on circuits controlled by different circuit breakers or fuses.)
Modifications to this product not authorized by Cisco Systems, Inc. could void the FCC approval and negate your authority to operate the product.
The Cisco implementation of TCP header compression is an adaptation of a program developed by the University of California, Berkeley (UCB) as part of UCB’s public domain version of the UNIX operating system. All rights reserved. Copyright © 1981, Regents of the University of California.
NOTWITHSTANDING ANY OTHER WARRANTY HEREIN, ALL DOCUMENT FILES AND SOFTWARE OF THESE SUPPLIERS ARE PROVIDED “AS IS” WITH ALL FAULTS. CISCO AND THE ABOVE-NAMED SUPPLIERS DISCLAIM ALL WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING, WITHOUT LIMITATION, THOSE OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT OR ARISING FROM A COURSE OF DEALING, USAGE, OR TRADE PRACTICE.
IN NO EVENT SHALL CISCO OR ITS SUPPLIERS BE LIABLE FOR ANY INDIRECT, SPECIAL, CONSEQUENTIAL, OR INCIDENTAL DAMAGES, INCLUDING, WITHOUT LIMITATION, LOST PROFITS OR LOSS OR DAMAGE TO DATA ARISING OUT OF THE USE OR INABILITY TO USE THIS MANUAL, EVEN IF CISCO OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.
CCDE, CCENT, CCSI, Cisco Eos, Cisco Explorer, Cisco HealthPresence, Cisco IronPort, the Cisco logo, Cisco Nurse Connect, Cisco Pulse, Cisco SensorBase,
Cisco StackPower, Cisco StadiumVision, Cisco TelePresence, Cisco TrustSec, Cisco Unified Computing System, Cisco WebEx, DCE, Flip Channels, Flip for Good, Flip Mino, Flipshare (Design), Flip Ultra, Flip Video, Flip Video (Design), Instant Broadband, and Welcome to the Human Network are trademarks; Changing the Way We Work, Live, Play, and Learn, Cisco Capital, Cisco Capital (Design), Cisco:Financed (Stylized), Cisco Store, Flip Gift Card, and One Million Acts of Green are service marks; and Access Registrar, Aironet, AllTouch, AsyncOS, Bringing the Meeting To You, Catalyst, CCDA, CCDP, CCIE, CCIP, CCNA, CCNP, CCSP, CCVP, Cisco, the
Cisco Certified Internetwork Expert logo, Cisco IOS, Cisco Lumin, Cisco Nexus, Cisco Press, Cisco Systems, Cisco Systems Capital, the Cisco Systems logo, Cisco Unity, Collaboration Without Limitation, Continuum, EtherFast, EtherSwitch, Event Center, Explorer, Follow Me Browsing, GainMaker, iLYNX, IOS, iPhone, IronPort, the IronPort logo, Laser Link, LightStream, Linksys, MeetingPlace, MeetingPlace Chime Sound, MGX, Networkers, Networking Academy, PCNow, PIX, PowerKEY, PowerPanels, PowerTV, PowerTV (Design), PowerVu, Prisma, ProConnect, ROSA, SenderBase, SMARTnet, Spectrum Expert, StackWise, WebEx, and the WebEx logo are registered trademarks of Cisco and/or its affiliates in the United States and certain other countries.
All other trademarks mentioned in this document or website are the property of their respective owners. The use of the word partner does not imply a partnership relationship between Cisco and any other company. (1002R)
Catalyst 3750-X and 3560-X Switch Hardware Installation Guide
© 2010 Cisco Systems, Inc. All rights reserved.
C O N T E N T S
|
Preface vii |
|
|
|
|
|
|
|
Purpose |
vii |
|
|
|
|
|
|
Related Publications |
vii |
|
|
|
||
|
Obtaining Documentation and Submitting a Service Request viii |
||||||
|
Product Overview |
|
|
|
|
|
|
C H A P T E R 1 |
1-1 |
|
|
|
|
||
|
Switch Models |
1-1 |
|
|
|
|
|
|
Front Panel Description |
1-3 |
|
|
|||
|
10/100/1000 Ethernet Ports |
1-3 |
|
||||
|
PoE+ Ports |
1-3 |
|
|
|
|
|
|
Network Modules |
1-4 |
|
|
|
||
|
SFP and SFP+ Modules |
1-5 |
|
|
|||
|
LEDs |
1-8 |
|
|
|
|
|
|
System LED |
1-9 |
|
|
|
||
|
XPS LED |
1-9 |
|
|
|
|
|
|
Port LEDs and Modes |
1-9 |
|
||||
|
USB Console LED |
1-11 |
|
|
|||
|
S-PWR LED (Catalyst 3750-X) |
1-12 |
|||||
|
Master LED (Catalyst 3750-X) |
1-12 |
|||||
|
Stack LED (Catalyst 3750-X) |
1-12 |
|||||
|
PoE+ LED 1-13 |
|
|
|
|||
|
Network Module LEDs |
1-14 |
|
||||
|
USB Mini-Type B Port |
1-14 |
|
|
|||
|
Rear Panel Description |
1-15 |
|
|
|||
|
RJ-45 Console Port LED |
1-16 |
|
||||
|
USB Type A Interface |
1-16 |
|
|
|||
|
StackWise Ports |
1-16 |
|
|
|
Power Supply Modules 1-17
Switch Power Supply Modules 1-17
Fan Modules |
1-19 |
XPS Connector |
1-19 |
StackPower Connector (Catalyst 3750-X Switches) 1-20
Catalyst 3750-X and 3560-X Switch Hardware Installation Guide
|
OL-19593-01 |
iii |
|
Contents
|
Management Ports |
1-20 |
|
|
|
|
|
|
Ethernet Management Port |
1-20 |
|
||||
|
USB Mini-Type B Port |
1-21 |
|
|
|||
|
Management Options |
1-21 |
|
|
|
|
|
|
Network Configurations |
1-22 |
|
|
|
||
|
Switch Installation 2-1 |
|
|
|
|
|
|
C H A P T E R 2 |
|
|
|
|
|
|
|
|
Preparing for Installation |
2-1 |
|
|
|
|
|
|
Safety Warnings |
2-1 |
|
|
|
|
|
|
Installation Guidelines |
2-3 |
|
|
|
||
|
Tools and Equipment |
2-4 |
|
|
|
|
|
|
Planning a Switch Data Stack (Catalyst 3750-X Switches) |
2-4 |
|||||
|
Switch Data Stacking Guidelines |
|
2-5 |
|
|||
|
Data Stack Cabling Configurations |
2-5 |
|
||||
|
Data Stack Bandwidth and Partitioning Examples 2-7 |
|
|||||
|
Power On Sequence for Switch Data Stacks 2-8 |
|
|||||
|
Planning a StackPower Stack (Catalyst 3750-X Switches) |
2-8 |
|||||
|
StackPower Stacking Guidelines |
|
2-8 |
|
|||
|
StackPower Cabling Configurations |
2-9 |
|
||||
|
StackPower Partitioning Examples |
2-14 |
|
||||
|
Installing the Switch |
2-14 |
|
|
|
|
|
|
Rack-Mounting 2-14 |
|
|
|
|
|
|
|
Attaching the Rack-Mount Brackets 2-17 |
|
|||||
|
Mounting the Switch in a Rack |
2-18 |
|
||||
|
Tableor Shelf-Mounting |
2-20 |
|
|
|
||
|
After Installing the Switch |
2-21 |
|
|
Connecting to the StackWise Ports (Catalyst 3750-X Switches) |
2-21 |
||
Connecting to the StackPower Ports (Catalyst 3750-X Switches) |
2-22 |
||
Connecting the StackPower Ports to the XPS-2200 2-23 |
|
||
Installing a Network Module in the Switch 2-23 |
|
||
Tools and Equipment 2-24 |
|
|
|
Installing Network Modules |
|
2-24 |
|
Removing a Network Module |
2-25 |
|
|
Installing SFP and SFP+ Modules |
2-25 |
|
|
Installing an SFP Module |
2-26 |
|
|
Removing an SFP Module |
2-27 |
|
Catalyst 3750-X and 3560-X Switch Hardware Installation Guide
|
iv |
OL-19593-01 |
|
|
|
Contents
|
Connecting Devices to the Ethernet Ports 2-27 |
|||
|
10/100/1000 Ethernet Port Connections |
2-28 |
||
|
PoE+ Port Connections |
2-28 |
|
|
|
Where to Go Next 2-29 |
|
|
|
|
Power Supply and Fan Module Installation |
|
||
C H A P T E R 3 |
3-1 |
|||
|
Power Supply Module Overview |
3-1 |
|
|
|
Installation Guidelines 3-5 |
|
|
|
|
Installing an AC Power Supply |
3-6 |
|
|
|
Installing a DC Power Supply |
|
3-7 |
|
|
Equipment That You Need |
3-8 |
|
|
|
Grounding the Switch |
3-9 |
|
|
Installing the DC Power Supply in the Switch |
3-10 |
|||
|
Wiring the DC Input Power Source |
3-11 |
|
||
|
Finding the Power Supply Module Serial Number |
3-12 |
|||
|
Fan Module Overview |
3-14 |
|
|
|
|
Installing a Fan Module |
|
3-15 |
|
|
|
Finding the Fan Module Serial Number |
3-15 |
|
||
|
Troubleshooting 4-1 |
|
|
|
|
C H A P T E R 4 |
|
|
|
|
|
|
Diagnosing Problems |
4-1 |
|
|
|
|
Switch POST Results |
4-1 |
|
|
|
|
Switch LEDs 4-1 |
|
|
|
|
|
Switch Connections |
4-2 |
|
|
|
Bad or Damaged Cable |
4-2 |
|
|
|
|
||
|
Ethernet and Fiber Cables 4-2 |
|
|
|
|
|||
|
Link Status |
4-2 |
|
|
|
|
|
|
|
10/100/1000 Port Connections 4-3 |
|
|
|
|
|||
|
PoE Port Connections |
4-3 |
|
|
|
|
||
|
SFP Modules |
4-3 |
|
|
|
|
|
|
|
Interface Settings |
4-4 |
|
|
|
|
|
|
|
Ping End Device |
4-4 |
|
|
|
|
|
|
|
Spanning Tree Loops |
4-4 |
|
|
|
|
||
|
Switch Performance |
4-4 |
|
|
|
|
|
|
|
Speed, Duplex, and Autonegotiation 4-4 |
|
|
|
|
|||
|
Autonegotiation and Network Interface Cards |
4-5 |
|
|
|
|||
|
Cabling Distance |
4-5 |
|
|
|
|
|
|
|
Resetting the Switch to the Factory Default Settings |
4-5 |
|
|
|
|||
|
|
|
|
Catalyst 3750-X and 3560-X Switch Hardware Installation Guide |
|
|
|
|
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
OL-19593-01 |
|
|
|
|
|
v |
|
|
|
|
|
|
|
|
Contents
|
|
Finding the Switch Serial Number |
4-6 |
|||
|
|
Replacing a Failed Data Stack Member (Catalyst 3750-X Switches) 4-6 |
||||
|
|
Technical Specifications |
|
|
|
|
A P P E N D I X |
A |
A-1 |
|
|
||
|
|
Switch Specifications |
A-1 |
|
|
|
|
|
Power Supply Module Specifications |
A-2 |
|||
|
|
Fan Module Specifications |
A-4 |
|
|
|
|
|
Connector and Cable Specifications |
|
|||
A P P E N D I X |
B |
B-1 |
||||
|
|
Connector Specifications |
B-1 |
|
|
|
|
|
10/100/1000 Ports |
B-1 |
|
|
|
|
|
10 Gigabit Ethernet CX1 (SFP+ Copper) Connectors B-2 |
||||
|
|
SFP and SFP+ Modules |
B-2 |
|
|
|
|
|
10/100 Ethernet Management Port |
B-3 |
|||
|
|
Console Port B-4 |
|
|
|
|
|
|
Cable and Adapter Specifications |
B-5 |
|||
|
|
SFP and SFP+ Module Cable Specifications B-5 |
||||
|
|
Four Twisted-Pair Cable Pinouts |
|
B-7 |
||
|
|
Two Twisted-Pair Cable Pinouts |
|
B-7 |
|
Identifying a Crossover Cable |
B-8 |
|
|
|
|
Console Port Adapter Pinouts |
B-8 |
|
|
|
|
Configuring the Switch with the CLI-Based Setup Program |
|
|||
A P P E N D I X C |
C-1 |
||||
|
Accessing the CLI C-1 |
|
|
|
|
|
Accessing the CLI Through Express Setup |
C-1 |
|
||
|
Accessing the CLI Through a Console Port |
C-1 |
|
||
|
RJ-45 Console Port |
C-2 |
|
|
|
|
USB Console Port |
C-2 |
|
|
|
|
Installing the Cisco Microsoft Windows USB Device Driver |
C-3 |
|||
|
Installing the Cisco Microsoft Windows XP USB Driver |
C-4 |
|||
|
Installing the Cisco Microsoft Windows 2000 USB Driver C-4 |
|
|
|
Installing the Cisco Microsoft Windows Vista and Windows 7 USB Driver |
C-4 |
|
|
|
|
Uninstalling the Cisco Microsoft Windows USB Driver C-5 |
|
|
|
|
|
Uninstalling the Cisco Microsoft Windows XP and 2000 USB Driver C-5 |
|
|
|
|
|
Uninstalling the Cisco Microsoft Windows Vista and Windows 7 USB Driver |
C-6 |
|
|
|
|
Entering the Initial Configuration Information C-6 |
|
|
|
|
|
IP Settings C-6 |
|
|
|
|
|
Configuring the Setup Program C-6 |
|
|
|
|
|
Catalyst 3750-X and 3560-X Switch Hardware Installation Guide |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
vi |
|
|
OL-19593-01 |
|
|
|
|
|
Contents
I N D E X
Catalyst 3750-X and 3560-X Switch Hardware Installation Guide
|
OL-19593-01 |
vii |
|
Contents
Catalyst 3750-X and 3560-X Switch Hardware Installation Guide
|
viii |
OL-19593-01 |
|
|
|
Purpose
This guide describes the hardware features of the Catalyst 3750-X and 3560-X switches. It describes the physical and performance characteristics of each switch, explains how to install a switch, and provides troubleshooting information.
This guide does not describe system messages that you might receive or how to configure your switch. See the switch software configuration guide, the switch command reference, and the switch system message guide on http://www.cisco.com/en/US/products/ps10745/tsd_products_support_series_home.html
Related Publications
Catalyst 3750-X switches:
http://www.cisco.com/en/US/products/ps10745/tsd_products_support_series_home.html
Catalyst 3560-X switches:
http://www.cisco.com/en/US/products/ps10744/tsd_products_support_series_home.html
•Catalyst 3750-X and 3560-X Switch Getting Started Guide
•Catalyst 3750-X and 3560-X Switch Hardware Installation Guide
•Regulatory Compliance and Safety Information for the Catalyst 3750-X and 3560-X Switch
•Installation Notes for the Catalyst 3750-X, Catalyst 3560-X Switch Power Supply Modules
•Installation Notes for the Catalyst 3750-X and 3560-X Switch Fan Module
•Installation Notes for the Catalyst 3750-X and 3560-X Switch Network Modules
•Release Notes for the Catalyst 3750-X and 3560-X Switch
•Catalyst 3750-X and 3560-X Switch Software Configuration Guide
•Catalyst 3750-X and 3560-X Switch Command Reference
•Catalyst 3750-X, 3750-E, 3560-X, and 3560-E Switch System Message Guide
•Cisco IOS Software Installation Document
Catalyst 3750-X and 3560-X Switch Hardware Installation Guide
|
OL-19593-01 |
vii |
|
Preface
Information about Cisco SFP and SFP+ modules is available from this Cisco.com site:
http://www.cisco.com/en/US/products/hw/modules/ps5455/prod_installation_guides_list.html
SFP compatibility matrix documents are available from this Cisco.com site:
http://www.cisco.com/en/US/products/hw/modules/ps5455/products_device_support_tables_list.html
Obtaining Documentation and Submitting a Service Request
For information on obtaining documentation, submitting a service request, and gathering additional information, see the monthly What’s New in Cisco Product Documentation, which also lists all new and revised Cisco technical documentation, at:
http://www.cisco.com/en/US/docs/general/whatsnew/whatsnew.html
Subscribe to the What’s New in Cisco Product Documentation as a Really Simple Syndication (RSS) feed and set content to be delivered directly to your desktop using a reader application. The RSS feeds are a free service and Cisco currently supports RSS Version 2.0.
Catalyst 3750-X and 3560-X Switch Hardware Installation Guide
|
viii |
OL-19593-01 |
|
|
|
C H A P T E R 1
The Catalyst 3750-X and 3560-X series switches are Ethernet switches to which you can connect devices such as Cisco IP Phones, Cisco Wireless Access Points, workstations, and other network devices such as servers, routers, and other switches.
The Catalyst 3750-X switches support stacking through Cisco StackWise technology and power management through StackPower. The Catalyst 3560-X switches do not support switch stacking or StackPower.
Unless otherwise noted, the term switch refers to a standalone switch and to a switch stack.
•Switch Models, page 1-1
•Front Panel Description, page 1-3
•Rear Panel Description, page 1-15
•Management Options, page 1-21
Table 1-1 |
Catalyst 3750-X Switch Models |
|
|
|
|
|
|
|
|
Switch Model |
|
Cisco IOS Image |
Description |
|
|
|
|
|
|
Catalyst 3750-X-24T-L |
LAN Base image |
24 |
10/100/1000 Ethernet ports, StackWise Plus, 1 |
|
|
|
|
network module1 slot, 350-W power supply |
|
Catalyst 3750-X-48T-L |
LAN Base image |
48 |
10/100/1000 Ethernet ports, StackWise Plus, |
|
|
|
|
one network module1 slot, 350-W power supply |
|
Catalyst 3750-X-24P-L |
LAN Base image |
24 |
10/100/1000 PoE+2 ports, StackWise Plus, 1 |
|
|
|
|
network module1 slot, 715-W power supply |
|
Catalyst 3750-X-48P-L |
LAN Base image |
48 |
10/100/1000 PoE+2 ports, StackWise Plus, |
|
|
|
|
one network module1 slot, 715-W power supply |
|
Catalyst 3750-X-48PF-L |
LAN Base image |
48 |
10/100/1000 PoE+2 ports, StackWise Plus, 1 |
|
|
|
|
network module1 slot, 1100-W power supply |
|
Catalyst 3750-X-24T-S |
IP Base image3 |
24 |
10/100/1000 Ethernet ports, StackWise Plus, |
|
|
|
|
StackPower, 1 network module1 slot, 350-W |
|
|
|
|
power supply |
|
|
|
|
|
|
Catalyst 3750-X and 3560-X Switch Hardware Installation Guide
|
OL-19593-01 |
1-1 |
|
|
|
Chapter 1 Product Overview
Switch Models
Table 1-1 |
Catalyst 3750-X Switch Models (continued) |
||
|
|
|
|
Switch Model |
|
Cisco IOS Image |
Description |
|
|
|
|
Catalyst 3750-X-48T-S |
IP Base image3 |
48 10/100/1000 Ethernet ports, StackWise Plus, |
|
|
|
|
StackPower, 1 network module1 slot, 350-W |
|
|
|
power supply |
|
|
|
|
Catalyst 3750-X-24P-S |
IP Base image3 |
24 10/100/1000 PoE+2 ports, StackWise Plus, |
|
|
|
|
StackPower, 1 network module1 slot, 715-W |
|
|
|
power supply |
|
|
|
|
Catalyst 3750-X-48P-S |
IP Base image3 |
48 10/100/1000 PoE+2 ports, StackWise Plus, |
|
|
|
|
StackPower, 1 network module1 slot, 715-W |
|
|
|
power supply |
|
|
|
|
Catalyst 3750-X-48PF-S |
IP Base image3 |
48 10/100/1000 PoE+2 ports, StackWise Plus, |
|
|
|
|
StackPower, 1 network module1 slot, 1100-W |
|
|
|
power supply |
|
|
|
|
1.Available network modules: 10-Gigabit Ethernet network module; 1-Gigabit Ethernet network module; blank module (see Table 1-3 on page 1-5).
2.PoE+ = Power over Ethernet plus (provides up to 30 W per port).
3.You can upgrade to the IP Services feature set when you order the switch.
Table 1-2 |
Catalyst 3560-X Switch Models |
|
|
|
|
|
|
|
|
Switch |
|
Part Number |
Description |
|
|
|
|
|
|
Catalyst 3560-X-24T-L |
LAN Base image |
24 |
10/100/1000 Ethernet ports, 1 network |
|
|
|
|
module1 slot, 350-W power supply |
|
Catalyst 3560-X-48T-L |
LAN Base image |
48 |
10/100/1000 Ethernet ports, 1 network |
|
|
|
|
module1 slot, 350-W power supply |
|
Catalyst 3560-X-24P-L |
LAN Base image |
24 |
10/100/1000 PoE+2 ports, 1 network |
|
|
|
|
module1 slot, 715-W power supply |
|
Catalyst 3560-X-48P-L |
LAN Base image |
48 |
10/100/1000 PoE+2 ports, 1 network |
|
|
|
|
module1 slot, 715-W power supply |
|
Catalyst 3560-X-48PF-L |
LAN Base image |
48 |
10/100/1000 PoE+2 ports, 1 network |
|
|
|
|
module1 slot, 1100-W power supply |
|
Catalyst 3560-X-24T-S |
IP Base image3 |
24 |
10/100/1000 Ethernet ports, 1 network |
|
|
|
|
module1 slot, 350-W power supply |
|
Catalyst 3560-X-48T-S |
IP Base image3 |
48 |
10/100/1000 Ethernet ports, 1 network |
|
|
|
|
module1 slot, 350-W power supply |
|
Catalyst 3560-X-24P-S |
IP Base image3 |
24 |
10/100/1000 PoE+2 ports, 1 network |
|
|
|
|
module1 slot, 715-W power supply |
|
Catalyst 3560-X-48P-S |
IP Base image3 |
48 |
10/100/1000 PoE+2 ports, 1 network |
|
|
|
|
module1 slot, 715-W power supply |
|
Catalyst 3560-X-48PF-S |
IP Base image3 |
48 |
10/100/1000 PoE+2 ports, 1 network |
|
|
|
|
module1 slot, 1100-W power supply |
1.Available network modules: 10-Gigabit Ethernet network module; 1-Gigabit Ethernet network module; blank module (see Table 1-3 on page 1-5).
2.PoE+ = Power over Ethernet plus (provides up to 30 W per port).
Catalyst 3750-X and 3560-X Switch Hardware Installation Guide
1-2 |
OL-19593-01 |
|
|
Chapter 1 Product Overview
3. You can upgrade to the IP Services feature set when you order the switch.
Front Panel Description
The switch front panel includes a USB Type B console port, the 10/100/1000 Ethernet ports or the 10/100/1000 PoE+ ports, the network module, and the switch LEDs. Figure 1-1 shows the Catalyst 3750-X-48 PoE+ switch as an example. All the Catalyst 3750-X and 3560-X switches have similar components.
Figure 1-1 Switch Front Panel
1 |
2 |
|
3 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
MODE |
CONSOLE |
SYST |
|
|
|
|
|
|
|
|
XPS |
STAT |
|
|
|
|
|
|
|
EN |
S- |
SPEED |
|
|
||
|
|
|
PWR |
MAST |
STACK |
DUPLX |
|
|
|
|
|
|
|
PoE |
|
||
1 |
2 |
|
|
|
|
|
|
|
|
3 |
4 |
6 |
|
|
|
|
|
|
|
5 |
8 |
|
|
|
|
|
|
|
|
7 |
9 |
10 |
|
|
|
|
|
|
|
|
|
|
11 |
12 |
13 |
14 |
16 |
|
|
|
|
|
|
|
|
|
15 |
17 |
18 |
|
|
|
|
|
|
|
|
|
|
19 |
20 |
|
|
|
|
||
|
|
|
|
|
|
|
21 |
22 |
23 |
24 |
|
|
|
|
|
|
|
|
|
25 |
26 |
28 |
|
|
|
|
|
|
|
|
|
27 |
29 |
30 |
|
|
|
|
|
|
|
|
|
|
|
|
31 |
32 |
33 |
34 |
|
|
|
|
|
|
|
|
|
35 |
36 |
||
|
|
|
|
|
|
|
|
|
37 |
38 |
40 |
|
|
|
|
|
|
39 |
41 |
42 |
|
|
|
|
|
|
|
43 |
44 |
|
||
|
|
|
|
|
45 |
||
|
|
|
|
|
|
Catalyst |
46 3750-X
47 |
48 |
PoE+48 |
4
|
C3KX- |
NM-10G |
NETWORK |
|
|
|
MODULE |
G1 |
G2/TE1 |
|
|
|
G3 |
G4/TE2 |
|
|
|
|
5
1 |
Mode button |
4 |
10/100/1000 ports |
|
|
|
|
2 |
USB Type B console port |
5 |
Network Module |
|
|
|
|
3 |
Status LEDs |
|
|
|
|
|
|
251960
The 10/100/1000 Ethernet ports use RJ-45 connectors with Ethernet pinouts. The maximum cable length is 328 feet (100 meters). The 100BASE-TX and 1000BASE-T traffic requires Category 5, Category 5e, or Category 6 unshielded twisted pair (UTP) cable. The 10BASE-T traffic can use Category 3 or Category 4 UTP cable.
For information about the 10/100/1000 Ethernet port connections and specifications, see the “10/100/1000 Ethernet Port Connections” section on page 2-28 and Appendix B, “Connector and Cable Specifications.”
The PoE+ ports use the same connectors as described in the previous section and provide this support.
•Support for IEEE 802.3af compliant powered devices (up to 15.4 W)
•Support for IEEE 802.3at compliant powered devices (up to 30 W)
•Support for Cisco enhanced PoE
•Support for prestandard Cisco powered devices
Catalyst 3750-X and 3560-X Switch Hardware Installation Guide
|
OL-19593-01 |
1-3 |
|
|
|
Chapter 1 Product Overview
Front Panel Description
•Configuration for StackPower PoE+. When the switch internal power supply module(s) cannot support the total load, StackPower configurations allow the switch to leverage power available from other switches (only Catalyst 3750-X switches)
•Configurable support for Cisco intelligent power management, including enhanced power negotiation, power reservation, and per-port power policing
Depending on the installed power supply modules, each port can deliver up to 30 W of PoE+. See Table 1-17 for the power supply matrix that defines the available PoE and PoE+ power per port.
Note The output of the PoE+ circuit has been evaluated as a Limited Power Source (LPS) per IEC 60950-1.
For information about power supply modules, PoE+ port connections, and PoE+ specifications, see the “Power Supply Modules” section on page 1-17, the “PoE+ Port Connections” section on page 2-28, and Appendix B, “Connector and Cable Specifications.”
The switch has one hot-swappable network module that provides SFP and SFP+ uplink ports to connect to other devices. You must insert the network module during switch operation. Operating the switch without a network module is not supported. A blank module is available.
The switch generates logs when you insert or remove a network module with SFP ports.
Catalyst 3750-X and 3560-X Switch Hardware Installation Guide
1-4 |
OL-19593-01 |
|
|
Chapter 1 Product Overview
Front Panel Description
Table 1-3 |
Network Modules |
|
|
|
|
Network Module1 |
Description |
|
Blank |
|
This module has no uplink ports. |
|
|
|
1-Gigabit Ethernet |
This module has four 1-Gigabit SFP module slots. Any combination of standard |
|
|
|
SFP modules are supported. SFP+ modules are not supported. |
|
|
If you insert an SFP+ module in the 1-Gigabit network module, the SFP+ |
|
|
module does not operate, and the switch logs an error message. |
|
|
|
10-Gigabit Ethernet |
This module has four slots. Two slots support only 1-Gigabit SFP modules, two |
|
|
|
slots support either 1-Gigabit SFP or 10-Gigabit SFP+ modules. |
|
|
The four slots are grouped as two pairs with each pair consisting of one SFP slot |
|
|
and one SFP+ slot. Each pair supports either two 1-Gigabit SFP modules or one |
|
|
10-Gigabit SFP+ module. A 10-Gigabit SFP+ module cannot operate at the same |
|
|
time as the corresponding 1-Gigabit SFP module in the pair. |
|
|
Supported combinations of SFP and SFP+ modules: |
|
|
• Slots 1, 2, 3, and 4 populated with 1-Gigabit SFP modules. |
|
|
• Slots 1 and 2 populated with 1-Gigabit SFP modules and Slot 4 populated |
|
|
with one 10-Gigabit SFP+ module. |
|
|
• Slot 2 populated with one 10-Gigabit SFP+ module and Slots 3 and 4 |
|
|
populated with 1-Gigabit SFP modules. |
|
|
• Slot 2 and Slot 4 each populated with 10-Gigabit SFP+ modules. |
|
|
A 10-Gigabit SFP+ module takes precedence over a 1-Gigabit SFP module |
|
|
except when an SFP module is first inserted in Slot 1 and has link. When you |
|
|
insert an SFP+ module in Slot 2, the SFP in Slot 1 retains link. The SFP+ module |
|
|
in Slot 2 does not operate. |
|
|
When the SFP module in Slot 1 is shutdown, loses link, or is removed, the SFP+ |
|
|
module in Slot 2 becomes operational. At this point, the SFP module in Slot 1 |
|
|
will not become operational under any circumstance for as long as an SFP+ |
|
|
module remains in Slot 2 whether it is link up or not. |
|
|
The same precedence applies to Slots 3 and 4. |
|
|
|
1. All network modules are hot-swappable.
For information about the network modules, see the “Installing a Network Module in the Switch” section on page 2-23. For cable specifications, see Appendix B, “Connector and Cable Specifications.”
The switch-Gigabit Ethernet SFP and SFP+ modules provide copper or fiber-optic connections to other devices. These transceiver modules are field-replaceable, providing the uplink interfaces when installed in an SFP module slot. The SFP modules have LC connectors for fiber-optic connections or RJ-45 connectors for copper connections.
Use only Cisco SFP modules on the switch.
Catalyst 3750-X and 3560-X Switch Hardware Installation Guide
|
OL-19593-01 |
1-5 |
|
|
|
Chapter 1 Product Overview
Front Panel Description
|
|
|
|
Table 1-4 |
Cisco SFP Modules Supported for the 3750-X and 3560-X Switches |
||
|
|
|
|
|
|
|
|
|
|
|
|
Part Number |
|
Description |
|
|
|
|
|
|
|
||
|
|
|
|
GLC-GE-100FX= |
100FX SFP on GE SFP ports for LAN switches1 |
||
|
|
|
|
GLC-LH-SM= |
|
GE SFP, LC connector LX/LH transceiver |
|
|
|
|
|
|
|
|
|
|
|
|
|
GLC-SX-MM= |
|
GE SFP, LC connector SX transceiver |
|
|
|
|
|
|
|
|
|
|
|
|
|
GLC-T= |
|
1000BASE-T SFP transceiver module for copper connections |
|
|
|
|
|
|
|
|
|
|
|
|
|
GLC-ZX-SM= |
|
1000BASE-ZX SFP module for SMF, 1550 nm |
|
|
|
|
|
|
|
|
|
|
|
|
|
GLC-BX-D= |
|
1000BASE-BX10 SFP module for single-strand SMF, 1490-nm TX, |
|
|
|
|
|
|
|
1310-nm RX wavelength |
|
|
|
|
|
|
|
|
|
|
|
|
|
GLC-BX-U= |
|
1000BASE-BX10 SFP module for single-strand SMF, 1310-nm TX, |
|
|
|
|
|
|
|
1490-nm RX wavelength |
|
|
|
|
|
|
|
||
|
|
|
|
CWDM-SFP-1470= |
CWDM 1470-nm SFP Gigabit Ethernet and 1G/2G FC |
||
|
|
|
|
|
|
||
|
|
|
|
CWDM-SFP-1490= |
CWDM 1490-nm SFP Gigabit Ethernet and 1G/2G FC |
||
|
|
|
|
|
|
||
|
|
|
|
CWDM-SFP-1510= |
CWDM 1510-nm SFP Gigabit Ethernet and 1G/2G FC |
||
|
|
|
|
|
|
||
|
|
|
|
CWDM-SFP-1530= |
CWDM 1530-nm SFP Gigabit Ethernet and 1G/2G FC |
||
|
|
|
|
|
|
||
|
|
|
|
CWDM-SFP-1550= |
CWDM 1550-nm SFP Gigabit Ethernet and 1G/2G FC |
||
|
|
|
|
|
|
||
|
|
|
|
CWDM-SFP-1570= |
CWDM 1570-nm SFP Gigabit Ethernet and 1G/2G FC |
||
|
|
|
|
|
|
||
|
|
|
|
CWDM-SFP-1590= |
CWDM 1590-nm SFP Gigabit Ethernet and 1G/2G FC |
||
|
|
|
|
|
|
||
|
|
|
|
CWDM-SFP-1610= |
CWDM 1610-nm SFP Gigabit Ethernet and 1G/2G FC |
||
|
|
|
|
|
|
|
|
|
|
|
|
SFP-GE-S= |
|
1000BASE-SX SFP module for MMF, 850 nm (DOM)2 |
|
|
|
|
|
SFP-GE-L= |
|
1000BASE-LX/LH SFP module for SMF, 1300 nm (DOM)2 |
|
|
|
|
|
DWDM-SFP-3033= |
DWDM SFP 1530.33-nm SFP (100 GHz ITU grid) |
||
|
|
|
|
|
|
||
|
|
|
|
DWDM-SFP-3112= |
DWDM SFP 1531.12-nm SFP (100 GHz ITU grid) |
||
|
|
|
|
|
|
||
|
|
|
|
DWDM-SFP-3190= |
DWDM SFP 1531.90-nm SFP (100 GHz ITU grid) |
||
|
|
|
|
|
|
||
|
|
|
|
DWDM-SFP-3268= |
DWDM SFP 1532.68-nm SFP (100 GHz ITU grid) |
||
|
|
|
|
|
|
||
|
|
|
|
DWDM-SFP-3346= |
DWDM SFP 1533.47-nm SFP (100 GHz ITU grid) |
||
|
|
|
|
|
|
||
|
|
|
|
DWDM-SFP-3425= |
DWDM SFP 1534.25-nm SFP (100 GHz ITU grid) |
||
|
|
|
|
|
|
||
|
|
|
|
DWDM-SFP-3504= |
DWDM SFP 1535.04-nm SFP (100 GHz ITU grid) |
||
|
|
|
|
|
|
||
|
|
|
|
DWDM-SFP-3582= |
DWDM SFP 1535.82-nm SFP (100 GHz ITU grid) |
||
|
|
|
|
|
|
||
|
|
|
|
DWDM-SFP-3661= |
DWDM SFP 1536.61-nm SFP (100 GHz ITU grid) |
||
|
|
|
|
|
|
||
|
|
|
|
DWDM-SFP-3739= |
DWDM SFP 1537.40-nm SFP (100 GHz ITU grid) |
||
|
|
|
|
|
|
||
|
|
|
|
DWDM-SFP-3819= |
DWDM SFP 1538.19-nm SFP (100 GHz ITU grid) |
||
|
|
|
|
|
|
||
|
|
|
|
DWDM-SFP-3898= |
DWDM SFP 1538.98-nm SFP (100 GHz ITU grid) |
||
|
|
|
|
|
|
||
|
|
|
|
DWDM-SFP-3977= |
DWDM SFP 1539.77-nm SFP (100 GHz ITU grid) |
||
|
|
|
|
|
|
||
|
|
|
|
DWDM-SFP-4056= |
DWDM SFP 1540.56-nm SFP (100 GHz ITU grid) |
||
|
|
|
|
|
|
||
|
|
|
|
DWDM-SFP-4134= |
DWDM SFP 1541.35-nm SFP (100 GHz ITU grid) |
||
|
|
|
|
|
|
||
|
|
|
|
DWDM-SFP-4214= |
DWDM SFP 1542.14-nm SFP (100 GHz ITU grid) |
||
|
|
|
|
|
|
||
|
|
|
|
DWDM-SFP-4294= |
DWDM SFP 1542.94-nm SFP (100 GHz ITU grid) |
||
|
|
|
|
|
|
|
|
|
|
|
Catalyst 3750-X and 3560-X Switch Hardware Installation Guide |
||||
|
|
|
|||||
|
|
|
|
|
|
|
|
|
1-6 |
|
|
|
|
OL-19593-01 |
|
|
|
|
|
|
|
Chapter 1 Product Overview
Front Panel Description
Table 1-4 |
Cisco SFP Modules Supported for the 3750-X and 3560-X Switches (continued) |
|
|
|
|
Part Number |
|
Description |
|
|
|
DWDM-SFP-4373= |
DWDM SFP 1543.73-nm SFP (100 GHz ITU grid) |
|
|
|
|
DWDM-SFP-4453= |
DWDM SFP 1544.53-nm SFP (100 GHz ITU grid) |
|
|
|
|
DWDM-SFP-4532= |
DWDM SFP 1545.32-nm SFP (100 GHz ITU grid) |
|
|
|
|
DWDM-SFP-4612= |
DWDM SFP 1546.12-nm SFP (100 GHz ITU grid) |
|
|
|
|
DWDM-SFP-4692= |
DWDM SFP 1546.92-nm SFP (100 GHz ITU grid) |
|
|
|
|
DWDM-SFP-4772= |
DWDM SFP 1547.72-nm SFP (100 GHz ITU grid) |
|
|
|
|
DWDM-SFP-4851= |
DWDM SFP 1548.51-nm SFP (100 GHz ITU grid) |
|
|
|
|
DWDM-SFP-4931= |
DWDM SFP 1549.32-nm SFP (100 GHz ITU grid) |
|
|
|
|
DWDM-SFP-5012= |
DWDM SFP 1550.12-nm SFP (100 GHz ITU grid) |
|
|
|
|
DWDM-SFP-5092= |
DWDM SFP 1550.92-nm SFP (100 GHz ITU grid) |
|
|
|
|
DWDM-SFP-5172= |
DWDM SFP 1551.72-nm SFP (100 GHz ITU grid) |
|
|
|
|
DWDM-SFP-5252= |
DWDM SFP 1552.52-nm SFP (100 GHz ITU grid) |
|
|
|
|
DWDM-SFP-5332= |
DWDM SFP 1553.33-nm SFP (100 GHz ITU grid) |
|
|
|
|
DWDM-SFP-5413= |
DWDM SFP 1554.13-nm SFP (100 GHz ITU grid) |
|
|
|
|
DWDM-SFP-5494= |
DWDM SFP 1554.94-nm SFP (100 GHz ITU grid) |
|
|
|
|
DWDM-SFP-5575= |
DWDM SFP 1555.75-nm SFP (100 GHz ITU grid) |
|
|
|
|
DWDM-SFP-5655= |
DWDM SFP 1556.55-nm SFP (100 GHz ITU grid) |
|
|
|
|
DWDM-SFP-5736= |
DWDM SFP 1557.36-nm SFP (100 GHz ITU grid) |
|
|
|
|
DWDM-SFP-5817= |
DWDM SFP 1558.17-nm SFP (100 GHz ITU grid) |
|
|
|
|
DWDM-SFP-5898= |
DWDM SFP 1558.98-nm SFP (100 GHz ITU grid) |
|
|
|
|
DWDM-SFP-5979= |
DWDM SFP 1559.79-nm SFP (100 GHz ITU grid) |
|
|
|
|
DWDM-SFP-6061= |
DWDM SFP 1560.61-nm SFP (100 GHz ITU grid) |
|
|
|
|
DWDM-SFP-6141= |
DWDM SFP 1561.42-nm SFP (100 GHz ITU grid) |
|
|
|
|
1.Not supported for NEBS.
2.DOM = digital optical monitoring.
l
|
|
Table 1-5 |
Cisco SFP+ Modules Supported for the 3750-X and 3560-X Switches |
|||||
|
|
|
|
|
|
|||
|
|
Part Number |
|
Description |
||||
|
|
|
|
|
|
|||
|
|
SFP-10G-LR= |
|
10 GBASE LR SFP+ transceiver module for SMF, |
||||
|
|
|
|
1350 nm, LC duplex connector |
||||
|
|
|
|
|
|
|||
|
|
SFP-10G-SR= |
|
10 GBASE SR SFP+ transceiver module for |
||||
|
|
|
|
MMF, 850 nm, LC duplex connector |
||||
|
|
|
|
|
||||
|
|
SFP-10G-LRM= |
10 GBASE-LRM SFP+ module for MMF and |
|||||
|
|
|
|
SMF, 1310 nm |
||||
|
|
|
|
|
||||
|
|
SFP-H10GB-CU1M= |
10 GBASE-CU Twinax SFP+ cable assembly, 1 |
|||||
|
|
|
|
meter |
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
Catalyst 3750-X and 3560-X Switch Hardware Installation Guide |
|
|
||
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
OL-19593-01 |
|
|
|
|
1-7 |
|
|
|
|
|
|
|
|
Chapter 1 Product Overview
Front Panel Description
Table 1-5 |
Cisco SFP+ Modules Supported for the 3750-X and 3560-X Switches |
||
|
|
|
|
Part Number |
|
Description |
|
|
|
|
|
SFP-H10GB-CU3M= |
10 GBASE-CU Twinax SFP+ cable assembly, 3 |
||
|
|
meters |
|
|
|
|
|
SFP-H10GB-CU5M= |
10 GBASE-CU Twinax SFP+ cable assembly, |
||
|
|
5meters |
|
|
|
|
|
For information about SFP modules, see your SFP module documentation and the “Installing SFP and SFP+ Modules” section on page 2-25. For cable specifications, see Appendix B, “Connector and Cable Specifications.”
Note When ordering or using CX1 cables, ensure that the version identifier is 2 or higher.
The Catalyst 3560-X switch supports the SFP module patch cable (CAB-SFP-50CM), a 0.5-meter, copper, passive cable with SFP module connectors at each end. This cable is only used with 1-Gigabit Ethernet SFP ports to connect two Catalyst 3560-X switches in a cascaded configuration.
You can use the switch LEDs to monitor switch activity and its performance. Figure 1-2 shows the Catalyst 3750-X switch LEDs and the Mode button that you use to select a port mode.
Figure 1-2 Switch Front Panel LEDs
|
1 |
2 |
3 |
4 |
|
|
|
5 |
|||
|
|
|
|||
MODE |
|
|
|
||
OLE |
|
|
|
||
|
CONS |
|
|
|
|
|
|
SY |
|
|
|
11 |
12 |
6 7 8 9 10
251962
1 |
System LED |
6 |
USB console port LED |
|
|
|
|
2 |
XPS1 LED |
7 |
S-PWR (StackPower) LED2 |
3 |
Status LED |
8 |
Master LED2 |
4 |
Speed LED |
9 |
Stack LED2 |
5 |
Duplex LED |
10 |
PoE+ LED3 |
1. XPS = Expandable power system.
Catalyst 3750-X and 3560-X Switch Hardware Installation Guide
1-8 |
OL-19593-01 |
|
|
Chapter 1 Product Overview
Front Panel Description
2.Only Catalyst 3750-X switches.
3.Only switches with PoE+ ports.
Table 1-6 |
System LED |
|
|
|
|
|
|
Color |
|
System Status |
|
|
|
|
|
Off |
|
System is not powered on. |
|
|
|
|
|
Green |
|
System is operating normally. |
|
|
|
|
|
Blinking Green |
|
Switch is running power on self-test (POST). |
|
|
|
||
Blinking Amber |
There is a fault with one of the following: |
||
|
|
• Network module (non-traffic-related) |
|
|
|
• |
Power supply |
|
|
• |
Fan module |
|
|
|
|
Amber |
|
System is receiving power but is not functioning properly. |
|
|
|
|
|
For information on the System LED colors during power-on self-test (POST), see the “Diagnosing Problems” section on page 4-1.
XPS LED
Table 1-7 |
XPS LED |
|
|
|
|
Color |
|
XPS Status |
|
|
|
Off |
|
XPS cable is not installed. |
|
|
Switch is in StackPower mode (Catalyst 3750-X). |
|
|
|
Green |
|
XPS is connected and ready to provide back-up power. |
|
|
|
Blinking green |
|
XPS is connected but is unavailable because it is providing power to another device |
|
|
(redundancy has been allocated to a neighboring device). |
|
|
|
Amber |
|
The XPS is in standby mode or in a fault condition. See the XPS-2200 |
|
|
documentation for information about the standby mode and fault conditions. |
|
|
|
Blinking amber |
|
The power supply in a switch has failed, and the XPS is providing power to that |
|
|
switch (redundancy has been allocated to this device). |
|
|
|
Each Ethernet port and 10-Gigabit Ethernet module slot has a port LED. These port LEDs, as a group or individually, display information about the switch and about the individual ports. The port mode determines the type of information shown by the port LEDs. Table 1-8 lists the mode LEDs and their associated port modes and meanings.
To select or change a mode, press the Mode button until the desired mode is highlighted. When you change port modes, the meanings of the port LED colors also change. Table 1-9 explains how to interpret the port LED colors in different port modes.
Catalyst 3750-X and 3560-X Switch Hardware Installation Guide
|
OL-19593-01 |
1-9 |
|
|
|
Chapter 1 Product Overview
Front Panel Description
When you press the Mode button on any switch in the Catalyst 3750-X switch stack, all the stack switches change to show the same selected mode. For example, if you press the Mode button on the stack master to show the SPEED LED, all the other switches in the stack also show the SPEED LED.
Table 1-8 |
Port Mode LEDs |
|
|
|
|
Mode LED |
Port Mode |
Description |
|
|
|
STAT |
Port status |
The port status. This is the default mode. |
|
|
|
SPEED |
Port speed |
The port operating speed: 10, 100, or 1000 Mb/s. |
|
|
|
DUPLX |
Port duplex mode |
The port duplex mode: full duplex or half duplex. |
|
|
Note The 10/100/1000 ports operate only in full-duplex |
|
|
mode. |
|
|
|
MAST1 |
Master |
The stack master status |
STACK1 |
Stack member status |
The stack member status. |
|
StackWise port status |
The StackWise port status. See the “Stack LED (Catalyst |
|
|
3750-X)” section on page 1-12. |
|
|
|
PoE+2 |
PoE+ port power |
The PoE+ port status. |
1.Only Catalyst 3750-X switches.
2.Only switches with PoE+ ports.
|
|
|
|
Table 1-9 |
Meaning of Switch LED Colors in Different Modes |
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
Port Mode |
|
Port LED Color |
Meaning |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
STAT |
|
Off |
No link, or port was administratively shut down. |
|
|
|
|
|
(port status) |
|
|
|
|
|
|
|
|
|
Green |
Link present, no activity. |
||
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Blinking green |
Activity. Port is sending or receiving data. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Alternating |
Link fault. Error frames can affect connectivity, and errors such as |
|
|
|
|
|
|
|
green-amber |
excessive collisions, CRC errors, and alignment and jabber errors |
|
|
|
|
|
|
|
|
are monitored for a link-fault indication. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Amber |
Port is blocked by Spanning Tree Protocol (STP) and is not |
|
|
|
|
|
|
|
|
forwarding data. |
|
|
|
|
|
|
|
|
After a port is reconfigured, the port LED can be amber for up to 30 |
|
|
|
|
|
|
|
|
seconds as STP checks the switch for possible loops. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
SPEED |
|
10/100/1000 ports |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Off |
Port is operating at 10 Mb/s. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Green |
Port is operating at 100 Mb/s. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Single green |
Port is operating at 1000 Mb/s. |
|
|
|
|
|
|
|
flash (on for |
|
|
|
|
|
|
|
|
100 ms, off for |
|
|
|
|
|
|
|
|
1900 ms) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Network module slots |
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Off |
Port is not operating. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Blinking green |
Port is operating at up to 10 Gb/s. |
|
|
|
|
|
|
|
|
||
|
|
|
Catalyst 3750-X and 3560-X Switch Hardware Installation Guide |
|||||
|
|
|
||||||
|
|
|
|
|
|
|
|
|
|
1-10 |
|
|
|
|
|
OL-19593-01 |
|
|
|
|
|
|
|
|
Chapter 1 Product Overview
Front Panel Description
Table 1-9 |
Meaning of Switch LED Colors in Different Modes (continued) |
|
|||||
|
|
|
|
|
|||
Port Mode |
|
Port LED Color |
Meaning |
|
|||
|
|
|
|
|
|||
DUPLX |
|
Off |
Port is operating in half duplex. |
|
|||
(duplex) |
|
|
|
|
|
|
|
|
Green |
Port is operating in full duplex. |
|
||||
|
|
|
|||||
|
|
|
|
|
|||
MAST1 |
|
Off |
The switch is not the stack master. |
|
|||
(data stack |
|
|
Note For a standalone switch, this LED is off. |
|
|||
master) |
|
|
|
||||
|
|
|
|
|
|
|
|
|
Green |
The switch is the stack master. |
|
||||
|
|
|
|||||
|
|
|
|
|
|||
|
|
Amber |
Error during stack master election. |
|
|||
|
|
|
|
|
|||
STACK1 |
|
Off |
No stack member corresponding to that member number. |
|
|||
(stack member) |
|
|
|
|
|||
|
Blinking green |
Stack member number. |
|
||||
|
|
|
|
|
|||
|
|
Green |
Member numbers of other stack member switches. |
|
|||
|
|
|
|
|
|||
PoE+2 |
|
Off |
PoE+ is off. |
|
|||
|
|
|
If the powered device is receiving power from an AC power source, |
|
|||
|
|
|
the port LED is off even if the device is connected to the switch port. |
|
|||
|
|
|
|
|
|||
|
|
Green |
PoE+ is on. The port LED is green when the switch port is providing |
|
|||
|
|
|
power. |
|
|||
|
|
|
|
|
|||
|
|
Alternating |
PoE+ is denied because providing power to the powered device will |
|
|||
|
|
green and |
exceed the switch power capacity. |
|
|||
|
|
amber |
|
|
|
|
|
|
|
|
|
|
|||
|
|
Blinking amber |
PoE+ is off due to a fault or because it has exceeded a limit set in |
|
|||
|
|
|
the switch software. |
|
|||
|
|
|
|
|
|
|
|
|
|
|
Caution PoE+ faults are caused when noncompliant cabling or |
|
|||
|
|
|
|
|
|
powered devices are connected to a PoE+ port. Use only |
|
|
|
|
|
|
|
standard-compliant cabling to connect Cisco prestandard |
|
|
|
|
|
|
|
IP Phones and wireless access points or |
|
|
|
|
|
|
|
IEEE 802.3af-compliant devices to PoE+ ports. You must |
|
|
|
|
|
|
|
remove from the network any cable or device that causes |
|
|
|
|
|
|
|
a PoE+ fault. |
|
|
|
|
|
|
|
||
|
|
|
|
|
|||
|
|
Amber |
PoE+ for the port has been disabled. |
|
|||
|
|
|
Note PoE+ is enabled by default. |
|
|||
|
|
|
|
|
|
|
|
1.Only Catalyst 3750-X switches.
2.Only switches with PoE or PoE+ ports.
The USB console LED shows whether there is an active USB connection to the port.
|
|
Catalyst 3750-X and 3560-X Switch Hardware Installation Guide |
|
|
|
|
|
|
|||
|
OL-19593-01 |
|
|
1-11 |
|
|
|
|
|
Chapter 1 Product Overview
Front Panel Description
Table 1-10 USB Console Port LED
Color |
Description |
|
|
Off |
USB console is disabled. |
|
|
Green |
USB console is enabled. |
|
|
Table 1-11 |
S-PWR LED |
|
|
|
|
Color |
|
Description |
|
|
|
Off |
|
StackPower cable is not connected, or the switch is in standalone |
|
|
mode. |
|
|
|
Green |
|
An XPS cable is connected to the XPS-2200. |
|
|
Each StackPower port is connected to another switch or to an |
|
|
XPS-2200 (Catalyst 3750-X switches). |
|
|
|
Blinking Green |
|
This appears on the switch in a StackPower ring configuration |
|
|
that detects an open ring or has only one StackPower cable |
|
|
connected, and no connection to an XPS-2200. |
|
|
|
Amber |
|
There is a fault: load shedding is occurring, a StackPower cable is |
|
|
defective, or administrative action is required. See the switch |
|
|
software configuration guide for information about configuring |
|
|
StackPower. |
|
|
|
Blinking Amber |
The StackPower budget is not sufficient to meet current power |
|
|
|
demands. |
|
|
|
|
Table 1-12 |
Master LED |
|
|
|
|
|
|
Color |
|
Description |
|
|
|
|
|
Off |
|
Switch is not the stack master. |
|
|
|
|
|
Green |
|
Switch is the stack master or a standalone switch. |
|
|
|
|
|
Amber |
|
An error occurred when the switch was selecting the stack master |
|
|
|
switch, or another type of stack error occurred. |
|
|
|
|
Stack LED (Catalyst 3750-X) |
|
|
The stack LED shows the sequence of member switches in a stack. Up to nine switches can be members of a stack. The first nine port LEDs show the member number of a switch in a stack. Figure 1-3 shows the LEDs on the first switch, which is stack member number 1. For example, if you press the Mode button and select Stack, the LED for port 1 blinks green. The LEDs for ports 2 and 3 are solid green, as these represent the member numbers of other switches in the stack. The other port LEDs are off because there are no more members in the stack.
|
Catalyst 3750-X and 3560-X Switch Hardware Installation Guide |
1-12 |
OL-19593-01 |
Chapter 1 Product Overview
Front Panel Description
Figure 1-3 |
Stack LED |
MODE |
|
1 |
2 |
MODE |
|
1 |
2 |
MODE |
|
1 |
2 |
CONSOLE SYST EN
3 |
4 |
|
5 |
CONSOLE |
|
|
SYST |
|
EN |
3 |
4 |
|
5 |
CONSOLE |
|
|
SYST |
|
EN |
3 |
4 |
|
5 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
MODE |
|
|
CONS |
OLE |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
SYST |
XPS |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
EN |
|
|
|
STAT |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
S-PWR |
|
|||
XPS |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
MAST |
||
STAT |
SPEED |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
S-PWR |
MAST |
DUPLX |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
S |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
TACK |
PoE |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
6 |
8 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
7 |
9 |
10 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
11 |
12 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
XPS |
STAT |
|
|
|
1 |
2 |
4 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
S-PWR |
SPEED |
|
|
3 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
MAST |
DUPLX |
|
|
5 |
6 |
8 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
S |
|
|
|
|
7 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
TACK |
PoE |
|
|
|
|
9 |
10 |
11 |
12 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1 |
2 |
3 |
4 |
|
|
|
|
1 |
|
2 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
5 |
6 |
7 |
8 |
|
3 |
4 |
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
9 |
10 |
11 |
12 |
5 |
6 |
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1 |
2 |
|
|
7 |
8 |
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
3 |
4 |
6 |
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
5 |
8 |
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
7 |
|
|
|
|
6 |
8 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
9 |
10 |
11 |
12 |
7 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Catalyst 3 |
||||
|
|
9 |
10 |
11 |
12 |
|
|
|
|
|
|
|
|
|
|
|
|
4 |
|
|
|
|
|
|
|
750-X |
PoE+48 |
||
XPS |
STAT |
|
|
|
1 |
2 |
4 |
|
|
|
|
|
|
|
|
|
|
|
5 |
|
|
|
|
|
|
|
|||
S-PWR |
MAST |
SPEED |
DUPLX |
|
|
5 |
6 |
8 |
|
|
|
|
|
|
|
|
|
6 |
|
|
|
|
|
||||||
|
S |
|
|
|
|
7 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||
|
|
TACK |
PoE |
|
|
|
|
9 |
10 |
11 |
12 |
|
|
|
|
|
|
|
|
|
|
|
|||||||
|
|
|
|
|
|
|
|
|
|
|
|
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
10 |
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
9 |
11 |
12 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1 |
2 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
3 |
4 |
6 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
5 |
8 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
7 |
|
|
|
|
6 |
8 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
9 |
10 |
11 |
12 |
7 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Catalyst 3 |
||||
|
|
9 |
10 |
11 |
12 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
750-X |
PoE+48 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||
|
|
|
|
|
1 |
2 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
3 |
4 |
6 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
5 |
8 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
7 |
10 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
9 |
11 |
12 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1 |
2 |
3 |
4 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
5 |
6 |
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
7 |
8 |
10 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
9 |
11 |
12 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1 |
2 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
3 |
4 |
6 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
5 |
8 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
7 |
10 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
9 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Catalyst 3750-X |
11 |
12 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
PoE+48 |
S |
|
|
|
|
PEED |
DUPLX |
|
||
S |
|
|
||
|
|
|
|
|
TACK |
PoE |
|
||
|
|
C3KX- |
|
NETWORK |
|
|
NM-10G |
||
|
|
|
|
MODULE |
9 |
10 |
11 |
12 |
|
G1 |
|
G2/TE1 |
||
|
|
|||
|
|
G3 |
G4/TE2 |
|
|
|
|
|
|
|
|
C3KX- |
|
NETWORK |
|
|
NM-10G |
||
|
|
|
|
MODULE |
G1 |
|
G2/TE1 |
|
|
|
|
G3 |
G4/TE2 |
|
|
|
|
|
|
|
|
C3KX- |
NM-10G |
NETWORK |
|
|
|
|
MODULE |
G1 |
|
G2/TE1 |
|
|
|
|
G3 |
G4/TE2 |
|
|
|
|
|
1
2
3
253198
1 |
Stack member 1 |
4 |
LED blinks green to show that this is switch 1 in the stack. |
|
|
|
|
2 |
Stack member 2 |
5 |
LED is solid green to show that switch 2 is a stack member. |
|
|
|
|
3 |
Stack member 3 |
6 |
LED is solid green to show that switch 3 is a stack member. |
|
|
|
|
When you select the Stack LED mode, the representative Stack LEDs are green when the StackWise ports are up, and the representative Stack LEDs are amber when the ports are down.
PoE+ LED
If the PoE+ LED mode is not selected on a switch with PoE+ ports, the PoE+ LED still shows detected PoE+ problems.
Table 1-13 |
PoE+ Mode LED |
|
|
|
|
Color |
|
PoE+ Status |
|
|
|
Off |
|
PoE+ mode is not selected. None of the 10/100/1000 ports have been denied power |
|
|
or are in a fault condition. |
|
|
|
Green |
|
PoE+ mode is selected, and the port LEDs show the PoE+ status. |
|
|
|
Blinking amber |
|
PoE+ mode is not selected. At least one of the 10/100/1000 ports has been denied |
|
|
power, or at least one of the 10/100/1000 ports has a PoE+ fault. |
|
|
|
|
|
Catalyst 3750-X and 3560-X Switch Hardware Installation Guide |
|
|
|
|
|
|
|||
|
OL-19593-01 |
|
|
1-13 |
|
|
|
|
|
Chapter 1 Product Overview
Front Panel Description
Figure 1-4 Network Module LEDs (10-Gigabit Network Module Shown)
|
C |
NETWORK |
|
3KX- |
|
|
|
MODULE |
47 |
48 |
|
|
1 |
2 |
3 |
4 |
|
|
|
|
|
1 |
G1 LED |
|
3 |
G3 LED |
2 |
G2/TE1 LED |
|
4 |
G4/TE2 LED |
253212
Table 1-14 |
Network Module LEDs |
|
||||
|
|
|
|
|||
Color |
|
Network Module Link Status |
|
|||
|
|
|
|
|||
Off |
|
Link is off. |
|
|||
|
|
|
|
|||
Green |
|
Link is on, no activity. |
|
|||
|
|
|
|
|||
Blinking green |
|
Activity on a link, no faults. |
|
|||
|
|
|
|
|||
Blinking amber |
|
Link is off due to a fault or because it has exceeded a limit set in the |
|
|||
|
|
switch software. |
|
|||
|
|
|
|
|
|
|
|
|
Caution Link faults are caused when noncompliant cabling is |
|
|||
|
|
|
|
|
connected to an SFP or SFP+ port. Use only |
|
|
|
|
|
|
standard-compliant cabling to connect to Cisco SFP and |
|
|
|
|
|
|
SFP+ ports. You must remove from the network any cable |
|
|
|
|
|
|
or device that causes a link fault. |
|
|
|
|
|
|
||
|
|
|
|
|||
Amber |
|
Link for the SFP or SFP+ has been disabled. |
|
|||
|
|
|
|
|
|
|
A USB 5-pin mini-Type B connector on the front panel is available for switch management (Figure 1-5).
Figure 1-5 |
USB Mini-Type B Console Port |
|
253163 |
See the “Management Ports” section on page 1-20 for details.
|
Catalyst 3750-X and 3560-X Switch Hardware Installation Guide |
1-14 |
OL-19593-01 |
Chapter 1 Product Overview
Rear Panel Description
The switch rear panel has a ground connector, an RJ-45 console port, an RJ-45 10/100 management port, a USB Type A connector, two StackWise connectors (only Catalyst 3750-X switches), two fan modules, an XPS-2200 connector, a StackPower connector (only Catalyst 3750-X switches), and two power supply module slots. See Figure 1-6, and the descriptions on the following pages. Figure 1-6 shows the Catalyst 3750-X-48 PoE+ switch, which has one connector for either a StackPower or an XPS connection, and one connector only for StackPower. Figure 1-7 shows the Catalyst 3560-X switch rear panel, which has one connector for XPS and no StackPower connector.
Figure 1-6 Catalyst 3750-X Switch Rear Panel
2 |
3 |
5 |
9 |
11 |
|
4 7
1
STACK 1 STACK 2
6
S-PWR
XPS
S-PWR
8 10
AC OK |
|
PS OK |
C3KX-PWR- |
|
|
|
715WAC |
AC OK |
|
PS OK |
C3KX-PWR- |
|
|
|
715WAC |
12 13
12 13
1 |
|
Ground connector |
8 |
Fan modules |
||||||||
|
|
|
|
|
|
|
|
|
|
|||
2 |
|
RJ 45 console port LED |
9 |
StackPower or XPS-2200 connector |
||||||||
|
|
|
|
|
|
|
|
|
|
|||
3 |
|
RJ-45 console port |
10 |
StackPower connector |
||||||||
|
|
|
|
|
|
|
|
|
|
|||
4 |
|
RJ-45 10/100 management port |
11 |
Power supply modules (AC power supply |
||||||||
|
|
|
|
|
|
|
|
|
|
|
|
modules shown) |
|
|
|
|
|
|
|
|
|
|
|||
5 |
|
USB Type A connector |
12 |
AC power (input) status LED |
||||||||
|
|
|
|
|
|
|
|
|
|
|||
6 |
|
Stack cable connectors |
13 |
Power supply (output) status LED |
||||||||
|
|
|
|
|
|
|
|
|
|
|||
7 |
|
Reset button |
|
|
||||||||
|
|
|
|
|
|
|
|
|
|
|
||
Figure 1-7 |
|
|
|
|
Catalyst 3560-X Switch Rear Panel |
|
||||||
|
2 |
3 |
5 |
8 |
|
10 |
||||||
1 |
|
|
|
|
4 |
|
6 |
|
|
|||
|
|
|
|
|
|
|
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
251961
XPS
AC OK
C3KX-PWR-715WAC
7
9
11 12
253392
|
|
Catalyst 3750-X and 3560-X Switch Hardware Installation Guide |
|
|
|
|
|
|
|||
|
OL-19593-01 |
|
|
1-15 |
|
|
|
|
|
Chapter 1 Product Overview
Rear Panel Description
1 |
Ground connector |
7 |
Fan modules |
|
|
|
|
2 |
RJ-45 console port LED |
8 |
XPS-2200 connector |
|
|
|
|
3 |
RJ-45 console port |
9 |
Power supply module slot (blank module |
|
|
|
shown) |
|
|
|
|
4 |
RJ-45 10/100 management port |
10 |
Power supply module (AC power supply |
|
|
|
module shown) |
|
|
|
|
5 |
USB Type A connector |
11 |
AC power (input) status LED |
|
|
|
|
6 |
Reset button |
12 |
Power supply (output) status LED |
|
|
|
|
RJ-45 Console Port LED
Table 1-15 |
RJ-45 Console Port LED |
|
|
|
|
Color |
|
RJ-45 Console Port Status |
|
|
|
Off |
|
RS-232 console is disabled. |
|
|
|
Green |
|
RS-232 console is enabled. |
|
|
|
The USB Type A interface provides access to external USB FLASH devices (also known as thumb drives or USB keys).
The interface supports Cisco USB flash drives with capacities from 64 MB to 1 GB.
Cisco IOS software provides standard file system access to the flash device: read, write, erase, and copy, as well as formatting of the flash device with a FAT file system. You can boot the switch from a USB drive.
For information about the switch management ports, see the switch software configuration guide and the command reference on Cisco.com and the “Connector and Cable Specifications” section on page B-1.
The Catalyst 3750-X switch ships with a 0.5-meter StackWise cable (CAB-STACK-50CM) that you can use to connect the StackWise ports.
Caution Use only approved cables (CAB-STACK-50CM, CAB-STACK-1M, CAB-STACK-3M, CAB-STACK-50CM-NH,CAB-STACK-1M-NH, or CAB-STACK-3M-NH), and connect only to similar Cisco equipment. Equipment might be damaged if connected to nonapproved Cisco cables or equipment.
You can order these StackWise cables from your Cisco sales representative:
•CAB-STACK-50CM (0.5-meter cable)
•CAB-STACK-1M= (1-meter cable)
•CAB-STACK-3M= (3-meter cable)
|
Catalyst 3750-X and 3560-X Switch Hardware Installation Guide |
1-16 |
OL-19593-01 |
Chapter 1 Product Overview
Rear Panel Description
•CAB-STACK-50CM-NH= (0.5-meter cable, nonhalogen)
•CAB-STACK-1M-NH= (1-meter cable, nonhalogen)
•CAB-STACK-3M-NH= (3-meter cable, nonhalogen)
The 24and 48-port switches are powered through one or two internal power supply modules. The “Switch Power Supply Modules” section on page 1-17 and Table 1-16 describe the supported power supply modules.
The switch has two internal power supply module slots. You can use two AC modules, two DC modules, a mixed configuration of one AC and one DC power supply module, or one power supply module and a blank module.
The switch can operate with either one or two active power supply modules or with power supplied by an XPS-2200. A Catalyst 3750-X switch that is in a StackPower stack can operate with power supplied by other switches in the stack.
Table 1-1 and Table 1-2 show the power supply modules that ship with each switch model. All power supply modules (except the blank modules) have internal fans. All switches ship with a blank power supply module in the second power supply slot.
Caution Do not operate the switch with one power supply module slot empty. For proper chassis cooling, both power supply module slots must be populated.
The 350-W and 715-W AC power supply modules are autoranging units that support input voltages between 100 and 240 VAC. The 1100-W power supply module is an autoranging unit that supports input voltages between 115 and 240 VAC. The 440-W DC power supply module has dual input feeds (A and B) and supports input voltages between 36 and 72 VDC. The output voltage range is 51–57 V.
Each AC power supply module has a power cord for connection to an AC power outlet. The 1100-W and 715-W modules use a 16-AWG cord (only North America). All other modules use an 18-AWG cord. The DC-power supply module must be wired to a DC-power source.
The XPS-2200 powers connected switches when the power supply is removed or fails. When a new switch power supply is installed, the switch software polls the device. The switch power supply again provides power, and the XPS-2200 is available to power other devices.
Table 1-16 shows the power supply modules available for Catalyst 3750-X and 3560-X switches and power supply configurations based on switch models.
|
|
Table 1-16 |
Switch Power Supply Modules |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
48-Port |
24-Port |
|
||
|
|
|
|
48-Port PoE+ |
24-Port PoE+ |
Non-PoE+ |
Non-PoE+ |
|
||
|
|
Power Supply Module |
Switch1 |
Switch |
Switch |
Switch |
|
|||
|
|
C3KX-PWR-1100WAC= |
Primary or spare |
Spare |
Spare |
Spare |
|
|||
|
|
C3KX-PWR-1100WAC-JP=2 |
|
|
|
|
|
|
|
|
|
|
C3KX-PWR-715WAC= |
Spare |
Primary or spare |
Spare |
Spare |
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Catalyst 3750-X and 3560-X Switch Hardware Installation Guide |
|
|
|
|||
|
|
|
|
|
|
|||||
|
|
|
|
|
|
|
|
|
|
|
|
OL-19593-01 |
|
|
|
|
|
|
1-17 |
|
|
|
|
|
|
|
|
|
|
Chapter 1 Product Overview
Rear Panel Description
Table 1-16 |
Switch Power Supply Modules (continued) |
|
|
||
|
|
|
|
|
|
|
|
|
|
48-Port |
24-Port |
|
|
48-Port PoE+ |
24-Port PoE+ |
Non-PoE+ |
Non-PoE+ |
Power Supply Module |
Switch1 |
Switch |
Switch |
Switch |
|
C3KX-PWR-350WAC= |
Spare |
Spare |
Primary or spare |
Primary or spare |
|
|
|
|
|
|
|
C3KX-PWR-440WDC= |
Primary or spare |
Primary or spare |
Primary or spare |
Primary or spare |
|
|
|
|
|
|
|
C3KX-PSBAY-BLNK |
Blank module |
Blank module |
Blank module |
Blank module |
|
|
|
|
|
|
|
1.For full 15.4 W support on a 48-port PoE+ switch, you must use a C3KX-PWR-1100WAC power supply module.
2.This module is used only in Japan.
Table 1-17 |
Switch Power Supply Requirements for PoE and PoE+ |
||||
|
|
|
|
||
PoE Option |
|
24-Port Switch |
48-Port Switch |
||
|
|
|
|
|
|
PoE (up to 15.4 W per port) |
(1) |
715-W power supply |
(1) |
1100-W power supply |
|
|
|
(2) |
440-W DC power supplies |
|
|
|
|
|
|
|
|
PoE+ (up to 30 W per port) |
(1) |
1100-W power supply |
(1) |
1100-W power supply plus one |
|
|
|
|
|
715-W power supply |
|
|
|
|
|
or |
|
|
|
|
|
(2) |
1100-W power supplies |
|
|
|
|
|
|
Note A 48-port switch with one 715-W power supply provides up to 8.7 W of PoE to all ports.
The power supply modules have two status LEDs.
Table 1-18 |
Switch Power Supply Module LEDs |
|
|
|
|
|
|
||
AC-Power Supply Module LEDs |
|
|
||
|
|
|
|
|
AC OK |
|
Description |
PS OK |
Description |
|
|
|
|
|
Off |
|
No AC input power. |
Off |
Output is disabled, or input is |
|
|
|
|
outside operating range (AC LED |
|
|
|
|
is off). |
|
|
|
|
|
Green |
|
AC input power present. |
Green |
Power output to switch active. |
|
|
|
|
|
|
|
|
Red |
Output has failed. |
|
|
|
|
|
DC-Power Supply Module LEDs |
|
|
||
|
|
|
|
|
DC OK |
|
Description |
PS OK |
Description |
|
|
|
|
|
Off |
|
No DC input power. |
Off |
Output is disabled, or input is |
|
|
|
|
outside operating range (DC LED |
|
|
|
|
is off). |
|
|
|
|
|
Green |
|
DC input power present. |
Green |
Power output to switch active. |
|
|
|
|
|
|
|
|
Red |
Output has failed. |
|
|
|
|
|
|
Catalyst 3750-X and 3560-X Switch Hardware Installation Guide |
1-18 |
OL-19593-01 |
Chapter 1 Product Overview
Rear Panel Description
For information about replacing a power supply module, wiring a DC power supply module, and module specifications, see Chapter 3, “Power Supply and Fan Module Installation,” and Appendix A, “Technical Specifications.”
The switch has two internal hot-swappable 12-V fan modules, each with two fans. The air circulation system consists of the fan modules and the power supply modules. The airflow patterns vary depending on the power supply configuration.
Figure 1-8 shows the airflow patterns for the 24and 48-port switches. The blue arrow shows cool air flow, and the red arrow shows warm air flow. When the fan modules are operating properly, a green LED is on at the top left corner of the fan assembly (viewed from the rear). If the fan fails, the LED turns to amber.
Figure 1-8 24and 48-Port Switch Airflow Patterns
MODE |
|
1 |
2 |
CONSOLE SYST EN
3 |
4 |
|
5 |
XPS |
STAT |
|
|
|
S-PWR |
SPEED |
|
||
MAST |
DUPLX |
|||
|
S |
|||
|
|
TACK |
PoE |
6 |
8 |
|
|
|
7 |
10 |
|
|
|
|
9 |
11 |
12 |
|
|
|
|
1 |
2 |
3 |
4 |
6 |
|
|
|
|
|
5 |
8 |
|
|
|
|
|
|
7 |
10 |
|
|
|
|
|
|
9 |
11 |
12 |
|
|
|
|
|
|
1 |
2 |
3 |
4 |
6 |
|
|
|
|
|
5 |
8 |
|
|
|
|
|
|
7 |
10 |
|
|
|
|
|
|
9 |
11 |
12 |
|
|
|
|
|
|
1 |
2 |
3 |
4 |
6 |
|
|
5 |
8 |
|
|
|
7 |
|
|
|
|
9 |
|
|
|
Catalyst |
|
|
|
|
C3KX- |
NM-10G |
NETWORK |
|
|
|
|
|
|
MODULE |
10 |
11 |
12 |
|
|
|
|
3750-X |
|
|
|
|
|
|
|
PoE+48 |
G1 |
G2/TE1 |
|
|
|
|
|
|
|
G3 |
G4/TE2 |
|
|
|
|
|
|
|
253199
For information about installing a fan module and the module specifications, see Chapter 3, “Power Supply and Fan Module Installation,” and Appendix A, “Technical Specifications.”
Warning Attach only the following Cisco external power system to the switch: XPS 2200. Statement 387
The Cisco XPS-2200 is a expandable power system that can support nine network switches and provides power to one or two failed switches at a time. It senses when the power supply of a connected switch fails and provides power to the failed switch.
Use the XPS-2200 only with approved Cisco XPS cables. You can order these XPS cables for connecting your switch to the XPS-2200 from your Cisco sales representative:
•CAB-XPS-58CM (0.58-meter cable)
•CAB-XPS-150CM (1.5-meter cable)
The Cisco XPS-2200 has a nominal output level of –56 V. The total maximum output power depends on the installed power supply modules.
|
|
Catalyst 3750-X and 3560-X Switch Hardware Installation Guide |
|
|
|
|
|
|
|||
|
OL-19593-01 |
|
|
1-19 |
|
|
|
|
|
Chapter 1 Product Overview
Rear Panel Description
The nine ports on the XPS-2200 provide the power and management signals to the Catalyst 3750-X and 3560-X switches. Other switch models do not support this management communication. The XPS-2200 communicates with each switch through the 12-pin cable. All connected switches can simultaneously communicate with the XPS-2200. You can configure these XPS-2200 features through the switch software:
•Enable XPS active or standby mode for each connected switch
•Configure switch priority for XPS support
•List the connected switches and power supply module sizes
•Report when a switch is powered by the XPS
•Report the XPS power supply module status
•Read and monitor backup, failure, and exception history
See the switch software configuration guide on Cisco.com:
http://www.cisco.com/en/US/products/ps10745/products_installation_and_ configuration_guides_list.html
The Catalyst 3750-X switches have a StackPower connector for use with Cisco StackPower cables to configure a switch power stack that includes up to four switches. By adding an XPS-2200 expandable power system, you can configure a power stack that comprises up to nine switches. A switch power stack can be configured in redundant or power-sharing mode.
You can order these StackPower cables from your Cisco sales representative:
•CAB-SPWR-30CM (0.3-meter cable)
•CAB-SPWR-150CM (1.5-meter cable)
For details about connecting StackPower cables and StackPower guidelines, see the “Planning a StackPower Stack (Catalyst 3750-X Switches)” section on page 2-8.
You can connect the switch to a host such as a Windows workstation or a terminal server through the 10/100 Ethernet management port or one of the console ports (see Figure 1-5 and Figure 1-6). The 10/100 Ethernet management port connection uses a RJ-45 crossover or straight-through cable. The RJ-45 console port connection uses the supplied RJ-45-to-DB-9 female cable. The USB console port uses a USB type-A-to-USB 5-pin mini-Type B cable.
Table 1-19 shows the Ethernet management port LED colors and their meanings.
Table 1-19 |
RJ-45 Console Port LED |
|
|
|
|
Color |
|
Description |
|
|
|
Green |
|
Active link to PC |
|
|
|
|
Catalyst 3750-X and 3560-X Switch Hardware Installation Guide |
1-20 |
OL-19593-01 |