ANKE60 SERIES NON-DUCT KIT INSTALLATION INSTRUCTIONS |
|
|
DIRECTIVES D’INSTALLATION DU KIT DE RECIRCULATION DE SÉRIE ANKE60 |
|
INSTRUCCIONES PARA LA INSTALACIÓN DEL CONJUNTO SIN TUBOS DE LA SERIE ANKE60 |
|
ENGLISH |
HOW TO INSTALL CHARCOAL FILTERS |
|
READ AND SAVE THESE INSTRUCTIONS |
|
|
INSTALLER: LEAVE THIS INSTRUCTION SHEET WITH THE HOMEOWNER |
SCREWS LOCATION |
|
|
|
|
THIS KIT CONTAINS: |
|
|
• |
1 SERVICE PARTS BAG (PART NO. SV08351) INCLUDING: |
1 USING NO. 8-18 X 3/8” PROVIDED SCREWS, |
|
8 NO. 8-10 X 1/2” SCREWS |
|
|
20 NO. 8-18 X 3/8" SCREWS (EXTRA SCREWS PROVIDED FOR LARGER HOODS) |
INSTALL BOTH FILTER SUPPORTS ON EACH SIDE OF |
|
4 NO. 8-32 X 1/2” SCREWS |
THE INTERNAL MOTOR(S). DISCARD EXTRA |
• |
1 NON-DUCT KIT FLUE |
SCREWS. |
• 1 12”WIRE SLEEVE |
|
•2 OR 4* CHARCOAL FILTER SUPPORTS
•2 OR 4* CHARCOAL FILTERS
*2 FOR 30” AND 36” WIDTH HOODS OR 4 FOR 42” AND 48” WIDTH HOODS
HA0060
CAUTION
•Remove protective plastic film covering the non-duct kit flue before installing it.
•Additional installers are recommended because of the large size and weight of the non duct kit flue and the hood.
WHEN PLANNING AN INSTALLATION, THE OVERALL HEIGHT OF THE NON-DUCT KIT FLUE AND THE HOOD
2 FOR EACH MOTOR SIDE, POSITION FILTER OVER ITS
SHOULD BE CONSIDERED. THE MINIMUM HOOD DISTANCE ABOVE COOKTOP MUST NOT BE LESS THAN
SUPPORT AND ROTATE TO LOCK IT IN PLACE.
24’’. A MAXIMUM OF 30” ABOVE COOKTOP IS RECOMMENDED FOR BEST CAPTURE OF COOKING IMPURITIES. DISTANCES OVER 30” ARE AT THE INSTALLER AND USERS DISCRETION.
C
L
NOTE: FOR CABINETS WITH RECESSED BOTTOM, |
|
|
|
|
|
HA0061 |
|
|
|
|
|||
|
ATTACH 4 WOOD FILLER STRIPS CUT TO |
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
||
|
LENGTH (NOT INCLUDED), AS SHOWN BESIDE. |
|
|
|
REPLACEMENT IS RECOMMENDED AFTER 30 HOURS OF COOKING OR SIX |
||||||||
|
SEE TABLE BELOW FOR WOOD FILLER STRIPS |
|
|
|
|||||||||
|
B |
B |
|
MONTHS OF OPERATION. REPLACE MORE OFTEN IF YOUR COOKING HABITS GEN- |
|||||||||
|
LOCATION. |
|
|
||||||||||
|
|
|
|
|
ERATES MORE GREASE. |
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
A |
A |
|
|
|
|
|
|
|
|
|
|
|
|
HD0268 |
|
|
|
|
|
|
|
|
|
|
|
RECIRCULATION KIT WIDTH |
CENTER OF |
CENTER OF |
|
FRANÇAIS |
|
|
|
|
|
|
||
|
|
|
|
|
LIRE ET CONSERVER CES DIRECTIVES |
|
|
|
|
|
|||
|
WOOD STRIP LOCATION (A) WOOD STRIP LOCATION (B) |
|
|
|
|
|
|||||||
|
30’’ |
13⅜” |
|
10” |
|
INSTALLATEUR : LAISSER CETTE FEUILLE DE DIRECTIVES AU PROPRIÉTAIRE |
|||||||
|
36” |
16⅜” |
|
10” |
|
|
|
|
|
|
|
|
|
|
42” |
19⅜” |
|
10” |
|
CE KIT COMPREND : |
|
|
|
|
|
|
|
|
48” |
22⅜” |
|
10” |
|
• |
1 SAC DE PIÈCES (N° SV08351) INCLUANT : |
|
|
|
|
|
|
|
|
|
|
|
|
|
8 VIS N° 8-10 X 1/2 po |
|
|
|
|
|
|
|
|
|
CUT-OUT OPENING FOR |
|
|
20 VIS N° 8-18 X 3/8 PO |
|
|
|
|
|
|
|
1 |
AS SHOWN BESIDE, IF THE POWER CABLE COMES |
|
|
(DES VIS ADDITIONNELLES SONT FOURNIES POUR LES PLUS GRANDES HOTTES), |
|
|
|||||||
HOUSE WIRING LOCATION |
|
|
|
|
|||||||||
|
FROM THE BACK WALL, CUT A HOLE IN THE BACK |
|
|
|
|
4 VIS N° 8-32 X 1/2 po |
|
|
|
|
|
|
|
|
WALL. IF THE POWER CABLE COMES FROM THE CAB- |
|
|
|
• |
1 MODULE DE RECIRCULATION |
|
|
|
|
|
||
|
INET, CUT A HOLE IN THE CABINET BASE. IF THE |
C |
|
|
• |
1 GAINE POUR FIL DE 12 PO |
|
|
|
|
|
||
|
CABLE RUNS INTO THE NON-DUCT KIT FLUE |
C |
|
• |
2 OU 4* SUPPORTS POUR FILTRE À CHARBON |
|
|
|
|
|
|||
|
L |
L |
3¼” |
|
|
|
|
|
|||||
|
THROUGH THE TOP GROMMET IT MUST BE SLIDE |
|
|
• |
2 OU 4* FILTRES À CHARBON |
|
|
|
|
|
|||
|
|
1¾” |
2¹/8” |
|
|
|
|
|
|||||
|
INTO THE WIRE SLEEVE (INCLUDED) TO PROTECT |
|
|
*2 POUR LES HOTTES DE 30 PO ET DE 36 PO DE LARGEUR |
|
|
|
|
|||||
|
|
A |
|
|
|
|
|
|
|||||
|
IT FROM GREASE. |
|
|
|
|
OU 4 POUR LES HOTTES DE 42 PO ET DE 48 PO DE LARGEUR |
|
|
|
|
|||
|
|
|
2” |
|
|
|
|
|
|
||||
|
|
|
HD0335A |
2” |
|
|
|
|
|
|
|
|
|
2 |
PLACE THE NON-DUCT KIT FLUE AT ITS LOCATION, |
|
|
|
|
|
ATTENTION |
|
|
|
|
|
|
|
|
|
• Retirer la pellicule de plastique protectrice recouvrant le module de recirculation |
||||||||||
|
UNDER THE CABINET. USING A PEN, MARK THE |
|
|
|
|||||||||
|
|
|
|
|
avant d’installer celui-ci. |
|
|
|
|
|
|||
|
POSITION OF THE MOUNTING SCREWS (SMALL PART |
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
• Des installateurs supplémentaires sont recommandés lors de l’installation vu la |
|||||||||
|
OF THE KEYHOLES). REMOVE THE NON-DUCT KIT |
|
|
|
|||||||||
|
|
|
|
|
grande dimension et le poids de lahotte et du module de recirculation. |
|
|||||||
|
FLUE AND INSTALL (4) NO. 8-10 X 1/2” SCREWS |
|
|
|
|
|
|||||||
|
|
|
|
|
|
|
|
|
|
|
|
||
|
LEAVING A 1/8” GAP. PLACE THE NON-DUCT |
KIT |
|
|
|
LORS DE LA PLANIFICATION DE L’INSTALLATION, LA HAUTEUR TOTALE DU MODULE DE RECIRCULATION |
|||||||
|
FLUE UNDER THE CABINET. IF THE POWER CABLE |
|
|
|
|||||||||
|
|
|
|
ET DE LA HOTTE DOIVENT ÊTRE PRISES EN CONSIDÉRATION. LA DISTANCE MINIMALE ENTRE LE BAS DE |
|||||||||
|
COMES FROM THE CABINET, RUN THE POWER CABLE |
|
|
|
|||||||||
|
|
|
|
LA HOTTE ET LA SURFACE DE CUISSON NE DOIT PAS ÊTRE INFÉRIEURE À 24 PO. UN MAXIMUM DE |
|||||||||
|
WITH SLEEVE INTO THE NON-DUCT KIT FLUE |
|
|
|
|||||||||
|
|
|
|
30 PO AU-DESSUS DE LA SURFACE DE CUISSON EST RECOMMANDÉ POUR UNE MEILLEURE ÉVACUATION |
|||||||||
|
THROUGH THE GROMMET LOCATED ON ITS TOP. |
HA0058 |
|
|
|||||||||
|
|
|
|
DES ODEURS DE CUISSON. UNE DISTANCE DE PLUS DE 30 PO DEMEURE À LA DISCRÉTION DE |
|||||||||
|
SLIDE THE FLUE IN POSITION AND SECURE IT BY |
|
|
|
|||||||||
|
|
|
|
L’INSTALLATEUR ET DE L’UTILISATEUR. |
|
|
|
|
|
||||
|
TIGHTENING THE SCREWS COMPLETELY. SECURE |
|
|
|
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
||
|
THE FLUE TO THE CABINET WITH THE REST OF THE |
|
|
|
|
|
|
|
|
|
|
|
|
|
NO. 8-10 X 1/2” SCREWS. |
|
|
|
|
|
|
|
|
|
C |
|
|
|
|
|
|
|
|
NOTE : SI LE FOND DE L’ARMOIRE EST EN RETRAIT, |
|
|
L |
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
Y FIXER 4 BAGUETTES DE BOIS DE |
|
|
|
|
|
|
3 |
INSTALL (4) NO. 8-32 X 1/2” SCREWS, LEAVING A |
|
|
|
|
LONGUEUR APPROPRIÉE (NON INCLUSES), |
|
|
|
|
|
||
|
1/8” GAP, IN FRONT AND REAR FLANGES (2 PER |
|
|
|
|
TEL QU’IL EST ILLUSTRÉ CI-CONTRE.VOIR LE |
|
|
|
|
|
||
|
FLANGES) OF THE NON-DUCT KIT FLUE, AS SHOWN |
|
|
|
|
TABLEAU CI-DESSOUS POUR L’EMPLACEMENT |
|
B |
B |
|
|
||
|
BESIDE. |
|
|
|
|
|
DES BAGUETTES DE BOIS. |
|
A |
|
A |
|
|
|
NOTE: IT IS A GOOD PRACTICE TO SEAL THE |
|
|
|
|
|
|
HD0268 |
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|||
|
NON-DUCT KIT FLUE AND HOOD HOLES |
|
|
|
|
|
|
|
|
|
|
|
|
|
WITH DUCT TAPE. |
|
HA0059 |
|
|
|
LARGEUR |
EMPLACEMENT DU CENTRE |
EMPLACEMENT DU CENTRE |
||||
|
|
|
|
|
|
DU MODULE |
DE LA BAGUETTE DE BOIS (A) DE LA BAGUETTE DE BOIS (B) |
||||||
|
|
|
|
|
|
|
|||||||
|
|
|
|
|
|
|
30 PO |
13⅜ PO |
|
|
|
10 PO |
|
|
|
|
|
|
|
|
36 PO |
16⅜ PO |
|
|
|
10 PO |
|
4 |
PLACE THE HOOD UNDER THE NON-DUCT KIT FLUE. |
|
|
|
|
42 PO |
19⅜ PO |
|
|
|
10 PO |
|
|
|
|
|
|
48 PO |
22⅜ PO |
|
|
|
10 PO |
|
|||
|
SLIDE THE HOOD IN POSITION AND SECURE IT BY |
|
|
|
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
||
|
TIGHTENING THE SCREWS COMPLETELY. FINALIZE |
|
|
|
1 |
TEL QU’IL EST ILLUSTRÉ CI-CONTRE, SI LE CÂBLE |
|
|
|
|
|
||
|
MOUNTING THE HOOD TO THE NON-DUCT KIT FLUE |
|
|
|
EMPLACEMENT DE LA DÉCOUPE DU |
||||||||
|
|
|
|
|
D’ALIMENTATION ÉLECTRIQUE PASSE PAR LE MUR |
||||||||
|
USING THE NO. 8-18 X 3/8” SCREWS (2 PER FLUE |
|
|
|
|
TROU POUR LE FIL D’ALIMENTATION |
|||||||
|
|
|
|
|
DU FOND, DÉCOUPER UN TROU DANS LE MUR. SI |
||||||||
|
SIDE, 4 OR LESS AT FRONT, DEPENDING |
ON |
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
LE CÂBLE D’ALIMENTATION ÉLECTRIQUE PASSE PAR |
|
|
|
|
|
|||
|
HOOD/FLUE WIDTH). SEE ILLUSTRATION BESIDE. |
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
L’ARMOIRE, DÉCOUPER UN TROU DANS LA BASE DE |
|
|
|
|
|
|||
|
CONTINUE THE HOOD INSTALLATION. |
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
L’ARMOIRE. SI LE CÂBLE |
D’ALIMENTATION EST |
|
C |
|
C |
|
|
|
|
|
|
|
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
L |
|
L |
3¼ PO |
||
|
|
|
HA0062 |
|
|
|
INSÉRÉ DANS LE PASSE-FILS SITUÉ SUR LE DESSUS |
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
2¹/8 PO |
|||
|
|
|
|
|
|
|
|
1¾ PO |
|
||||
|
|
|
|
|
|
|
ET QU’IL TRAVERSE LE KIT DE RECIRCULATION, IL |
|
|
||||
|
|
|
|
|
|
|
|
|
A |
|
|||
|
|
|
|
|
|
|
DOIT ÊTRE GLISSÉ DANS LA GAINE POUR FIL |
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
2 PO |
|||
|
|
|
|
|
|
|
(FOURNIE) POUR LE PROTÉGER DES GRAISSES. |
HD0335F |
|
2 PO |
|
||
|
|
|
BROAN-NUTONE LLC; HARTFORD, WISCONSIN |
WWW.BROAN.COM 800-558-1711 |
|
|
|
SUITE AU VERSO |
|||||
|
|
|
BROAN-NUTONE CANADA; MISSISSAUGA, ONTARIO WWW.BROAN.CA 877-896-1119 |
|
|
|
SV08350 rev. C |