ANKE60 SERIES NON-DUCT KIT INSTALLATION INSTRUCTIONS

 

 

DIRECTIVES DINSTALLATION DU KIT DE RECIRCULATION DE SÉRIE ANKE60

 

INSTRUCCIONES PARA LA INSTALACIÓN DEL CONJUNTO SIN TUBOS DE LA SERIE ANKE60

ENGLISH

HOW TO INSTALL CHARCOAL FILTERS

READ AND SAVE THESE INSTRUCTIONS

 

INSTALLER: LEAVE THIS INSTRUCTION SHEET WITH THE HOMEOWNER

SCREWS LOCATION

 

 

THIS KIT CONTAINS:

 

1 SERVICE PARTS BAG (PART NO. SV08351) INCLUDING:

1 USING NO. 8-18 X 3/8” PROVIDED SCREWS,

 

8 NO. 8-10 X 1/2” SCREWS

 

20 NO. 8-18 X 3/8" SCREWS (EXTRA SCREWS PROVIDED FOR LARGER HOODS)

INSTALL BOTH FILTER SUPPORTS ON EACH SIDE OF

 

4 NO. 8-32 X 1/2” SCREWS

THE INTERNAL MOTOR(S). DISCARD EXTRA

1 NON-DUCT KIT FLUE

SCREWS.

• 1 12”WIRE SLEEVE

 

2 OR 4* CHARCOAL FILTER SUPPORTS

2 OR 4* CHARCOAL FILTERS

*2 FOR 30” AND 36” WIDTH HOODS OR 4 FOR 42” AND 48” WIDTH HOODS

HA0060

CAUTION

Remove protective plastic film covering the non-duct kit flue before installing it.

Additional installers are recommended because of the large size and weight of the non duct kit flue and the hood.

WHEN PLANNING AN INSTALLATION, THE OVERALL HEIGHT OF THE NON-DUCT KIT FLUE AND THE HOOD

2 FOR EACH MOTOR SIDE, POSITION FILTER OVER ITS

SHOULD BE CONSIDERED. THE MINIMUM HOOD DISTANCE ABOVE COOKTOP MUST NOT BE LESS THAN

SUPPORT AND ROTATE TO LOCK IT IN PLACE.

24’’. A MAXIMUM OF 30” ABOVE COOKTOP IS RECOMMENDED FOR BEST CAPTURE OF COOKING IMPURITIES. DISTANCES OVER 30” ARE AT THE INSTALLER AND USERS DISCRETION.

C

L

NOTE: FOR CABINETS WITH RECESSED BOTTOM,

 

 

 

 

 

HA0061

 

 

 

 

 

ATTACH 4 WOOD FILLER STRIPS CUT TO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LENGTH (NOT INCLUDED), AS SHOWN BESIDE.

 

 

 

REPLACEMENT IS RECOMMENDED AFTER 30 HOURS OF COOKING OR SIX

 

SEE TABLE BELOW FOR WOOD FILLER STRIPS

 

 

 

 

B

B

 

MONTHS OF OPERATION. REPLACE MORE OFTEN IF YOUR COOKING HABITS GEN-

 

LOCATION.

 

 

 

 

 

 

 

ERATES MORE GREASE.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A

A

 

 

 

 

 

 

 

 

 

 

 

 

HD0268

 

 

 

 

 

 

 

 

 

 

 

RECIRCULATION KIT WIDTH

CENTER OF

CENTER OF

 

FRANÇAIS

 

 

 

 

 

 

 

 

 

 

 

LIRE ET CONSERVER CES DIRECTIVES

 

 

 

 

 

 

WOOD STRIP LOCATION (A) WOOD STRIP LOCATION (B)

 

 

 

 

 

 

30’’

13⅜”

 

10”

 

INSTALLATEUR : LAISSER CETTE FEUILLE DE DIRECTIVES AU PROPRIÉTAIRE

 

36”

16⅜”

 

10”

 

 

 

 

 

 

 

 

 

 

42”

19⅜”

 

10”

 

CE KIT COMPREND :

 

 

 

 

 

 

 

48”

22⅜”

 

10”

 

1 SAC DE PIÈCES (N° SV08351) INCLUANT :

 

 

 

 

 

 

 

 

 

 

 

 

8 VIS N° 8-10 X 1/2 po

 

 

 

 

 

 

 

 

 

CUT-OUT OPENING FOR

 

 

20 VIS N° 8-18 X 3/8 PO

 

 

 

 

 

 

1

AS SHOWN BESIDE, IF THE POWER CABLE COMES

 

 

(DES VIS ADDITIONNELLES SONT FOURNIES POUR LES PLUS GRANDES HOTTES),

 

 

HOUSE WIRING LOCATION

 

 

 

 

 

FROM THE BACK WALL, CUT A HOLE IN THE BACK

 

 

 

 

4 VIS N° 8-32 X 1/2 po

 

 

 

 

 

 

 

WALL. IF THE POWER CABLE COMES FROM THE CAB-

 

 

 

1 MODULE DE RECIRCULATION

 

 

 

 

 

 

INET, CUT A HOLE IN THE CABINET BASE. IF THE

C

 

 

1 GAINE POUR FIL DE 12 PO

 

 

 

 

 

 

CABLE RUNS INTO THE NON-DUCT KIT FLUE

C

 

2 OU 4* SUPPORTS POUR FILTRE À CHARBON

 

 

 

 

 

 

L

L

3¼”

 

 

 

 

 

 

THROUGH THE TOP GROMMET IT MUST BE SLIDE

 

 

2 OU 4* FILTRES À CHARBON

 

 

 

 

 

 

 

1¾”

2¹/8

 

 

 

 

 

 

INTO THE WIRE SLEEVE (INCLUDED) TO PROTECT

 

 

*2 POUR LES HOTTES DE 30 PO ET DE 36 PO DE LARGEUR

 

 

 

 

 

 

A

 

 

 

 

 

 

 

IT FROM GREASE.

 

 

 

 

OU 4 POUR LES HOTTES DE 42 PO ET DE 48 PO DE LARGEUR

 

 

 

 

 

 

 

2”

 

 

 

 

 

 

 

 

 

HD0335A

2”

 

 

 

 

 

 

 

 

 

2

PLACE THE NON-DUCT KIT FLUE AT ITS LOCATION,

 

 

 

 

 

ATTENTION

 

 

 

 

 

 

 

 

• Retirer la pellicule de plastique protectrice recouvrant le module de recirculation

 

UNDER THE CABINET. USING A PEN, MARK THE

 

 

 

 

 

 

 

 

avant d’installer celui-ci.

 

 

 

 

 

 

POSITION OF THE MOUNTING SCREWS (SMALL PART

 

 

 

 

 

 

 

 

 

 

 

 

 

• Des installateurs supplémentaires sont recommandés lors de l’installation vu la

 

OF THE KEYHOLES). REMOVE THE NON-DUCT KIT

 

 

 

 

 

 

 

 

grande dimension et le poids de lahotte et du module de recirculation.

 

 

FLUE AND INSTALL (4) NO. 8-10 X 1/2” SCREWS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LEAVING A 1/8” GAP. PLACE THE NON-DUCT

KIT

 

 

 

LORS DE LA PLANIFICATION DE LINSTALLATION, LA HAUTEUR TOTALE DU MODULE DE RECIRCULATION

 

FLUE UNDER THE CABINET. IF THE POWER CABLE

 

 

 

 

 

 

 

ET DE LA HOTTE DOIVENT ÊTRE PRISES EN CONSIDÉRATION. LA DISTANCE MINIMALE ENTRE LE BAS DE

 

COMES FROM THE CABINET, RUN THE POWER CABLE

 

 

 

 

 

 

 

LA HOTTE ET LA SURFACE DE CUISSON NE DOIT PAS ÊTRE INFÉRIEURE À 24 PO. UN MAXIMUM DE

 

WITH SLEEVE INTO THE NON-DUCT KIT FLUE

 

 

 

 

 

 

 

30 PO AU-DESSUS DE LA SURFACE DE CUISSON EST RECOMMANDÉ POUR UNE MEILLEURE ÉVACUATION

 

THROUGH THE GROMMET LOCATED ON ITS TOP.

HA0058

 

 

 

 

 

 

DES ODEURS DE CUISSON. UNE DISTANCE DE PLUS DE 30 PO DEMEURE À LA DISCRÉTION DE

 

SLIDE THE FLUE IN POSITION AND SECURE IT BY

 

 

 

 

 

 

 

LINSTALLATEUR ET DE LUTILISATEUR.

 

 

 

 

 

 

TIGHTENING THE SCREWS COMPLETELY. SECURE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

THE FLUE TO THE CABINET WITH THE REST OF THE

 

 

 

 

 

 

 

 

 

 

 

 

NO. 8-10 X 1/2” SCREWS.

 

 

 

 

 

 

 

 

 

C

 

 

 

 

 

 

 

 

NOTE : SI LE FOND DE LARMOIRE EST EN RETRAIT,

 

 

L

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Y FIXER 4 BAGUETTES DE BOIS DE

 

 

 

 

 

3

INSTALL (4) NO. 8-32 X 1/2” SCREWS, LEAVING A

 

 

 

 

LONGUEUR APPROPRIÉE (NON INCLUSES),

 

 

 

 

 

 

1/8” GAP, IN FRONT AND REAR FLANGES (2 PER

 

 

 

 

TEL QUIL EST ILLUSTRÉ CI-CONTRE.VOIR LE

 

 

 

 

 

 

FLANGES) OF THE NON-DUCT KIT FLUE, AS SHOWN

 

 

 

 

TABLEAU CI-DESSOUS POUR LEMPLACEMENT

 

B

B

 

 

 

BESIDE.

 

 

 

 

 

DES BAGUETTES DE BOIS.

 

A

 

A

 

 

NOTE: IT IS A GOOD PRACTICE TO SEAL THE

 

 

 

 

 

 

HD0268

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NON-DUCT KIT FLUE AND HOOD HOLES

 

 

 

 

 

 

 

 

 

 

 

 

WITH DUCT TAPE.

 

HA0059

 

 

 

LARGEUR

EMPLACEMENT DU CENTRE

EMPLACEMENT DU CENTRE

 

 

 

 

 

 

DU MODULE

DE LA BAGUETTE DE BOIS (A) DE LA BAGUETTE DE BOIS (B)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

30 PO

13⅜ PO

 

 

 

10 PO

 

 

 

 

 

 

 

 

36 PO

16⅜ PO

 

 

 

10 PO

 

4

PLACE THE HOOD UNDER THE NON-DUCT KIT FLUE.

 

 

 

 

42 PO

19⅜ PO

 

 

 

10 PO

 

 

 

 

 

48 PO

22⅜ PO

 

 

 

10 PO

 

 

SLIDE THE HOOD IN POSITION AND SECURE IT BY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TIGHTENING THE SCREWS COMPLETELY. FINALIZE

 

 

 

1

TEL QUIL EST ILLUSTRÉ CI-CONTRE, SI LE CÂBLE

 

 

 

 

 

 

MOUNTING THE HOOD TO THE NON-DUCT KIT FLUE

 

 

 

EMPLACEMENT DE LA DÉCOUPE DU

 

 

 

 

 

DALIMENTATION ÉLECTRIQUE PASSE PAR LE MUR

 

USING THE NO. 8-18 X 3/8” SCREWS (2 PER FLUE

 

 

 

 

TROU POUR LE FIL D’ALIMENTATION

 

 

 

 

 

DU FOND, DÉCOUPER UN TROU DANS LE MUR. SI

 

SIDE, 4 OR LESS AT FRONT, DEPENDING

ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LE CÂBLE DALIMENTATION ÉLECTRIQUE PASSE PAR

 

 

 

 

 

 

HOOD/FLUE WIDTH). SEE ILLUSTRATION BESIDE.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LARMOIRE, DÉCOUPER UN TROU DANS LA BASE DE

 

 

 

 

 

 

CONTINUE THE HOOD INSTALLATION.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LARMOIRE. SI LE CÂBLE

DALIMENTATION EST

 

C

 

C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

L

 

L

PO

 

 

 

HA0062

 

 

 

INSÉRÉ DANS LE PASSE-FILS SITUÉ SUR LE DESSUS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2¹/8 PO

 

 

 

 

 

 

 

 

PO

 

 

 

 

 

 

 

 

ET QUIL TRAVERSE LE KIT DE RECIRCULATION, IL

 

 

 

 

 

 

 

 

 

 

 

A

 

 

 

 

 

 

 

 

DOIT ÊTRE GLISSÉ DANS LA GAINE POUR FIL

 

 

 

 

 

 

 

 

 

 

 

 

 

2 PO

 

 

 

 

 

 

 

(FOURNIE) POUR LE PROTÉGER DES GRAISSES.

HD0335F

 

2 PO

 

 

 

 

BROAN-NUTONE LLC; HARTFORD, WISCONSIN

WWW.BROAN.COM 800-558-1711

 

 

 

SUITE AU VERSO

 

 

 

BROAN-NUTONE CANADA; MISSISSAUGA, ONTARIO WWW.BROAN.CA 877-896-1119

 

 

 

SV08350 rev. C

Loading...
+ 1 hidden pages