ADA HIGH VOLTAGE WIRING INSTRUCTIONS FOR SINGLE BLOWER RANGE HOODS WITH

ROCKER SWITCH CONTROL

! WARNING

For residential (domestic) installation only. Before proceeding, switch power off at service panel and lock service disconnecting means to prevent power from being switched on accidentally. Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction codes and standards. Also, it is recommended to wear safety glasses and gloves.

ACCESS TO RANGE HOOD CONTROL PANEL CONNECTIONS

NOTE: The illustrations in this procedure are generic; some hood details may slightly differ from the hood you have on hand but the procedure itself applies to all single blower range hoods listed in this document (see page 3).

Remove filters from the hood and set them aside. NOTE: Some models have only one filter.

Remove the wiring cover (shaded part on illustration below) retaining screw. Slide out the wiring cover from the hood and set it aside with its screw.

Using a 11/32'' socket, remove the 6 nuts retaining the blower chamber to the hood assembly (2 nuts on inner back and 2 other nuts per sides), then use a Phillips no. 2 screwdriver to remove both front corner screws. See picture below for nuts and screws locations. Pull out the blower chamber from the hood assembly and set it aside with its retaining screws and nuts.

Wiring cover

screw

Unplug the blower connector from the main harness.

Nuts

Nuts

Screw

HD0672

Remove and set aside the 4 front screws retaining the bent plate to the hood.

Screw locations

HD0673

Fold back the bent plate to access to control panel connections.

HE0253

HD0674

1

99045858A

CAUTION

Use standard switches that are rated 120 VCA, 15 A. Only use wires suitable for at least 90oC (194oF). Ensure the wires are reliably routed away from the halogen lights (if present).

According to your needs, there are 2 ways to wire a 2-rocker switch control to these range hoods: 120 VAC power cable entering the range hood or 120 VAC power cable entering the switch box.

120 VAC POWER CABLE ENTERING THE HOOD

 

2-ROCKER

 

 

SWITCH

 

Install a 2-rocker switch at a convenient place for the

RED

 

(motor)

GROUND

user. Use a 14/3 cable to wire it to the range hood

 

WHITE

 

(see diagram at right).

BLACK

 

NOTE: Code requires both ends of WHITE wire

 

(lights)

 

insulation to be colored; use a permanent

 

 

marker.

 

 

Motor switch

Light switch

 

14/3 CABLE

NOTE: Allow enough length of 14/3 cable to perform the RED wire

TO HOOD

 

connection in the hood nose.

 

Insert the 14/3 cable along with the 14/2 house wiring cable in the

3

5

hood through an UL approved wire clamp, suitable for 2 cables.

 

TO CONTROL PANEL

 

 

Add a GROUND wire and connect one end to the GREEN ground

 

2

screw. Use an appropriate wire nut to connect the other end of the

 

added GROUND wire with the ground wire coming from the 14/3

4

 

cable and the ground wire coming from 14/2 house wiring cable.

MOTOR

Connect BLACK wire from house wiring to WHITE wire from

 

GROUND

 

WIRE

14/3 cable using an appropriate wire nut.

Connect BLACK wire from 14/3 cable to BLACK wire from range

 

BLACK

 

WHITE

hood wiring using an appropriate wire nut.

 

1

 

Connect WHITE wire from house wiring to WHITE wire range

RED

GROUND

hood wiring using an appropriate wire nut.

 

 

 

Run RED wire from 14/3 cable through bend plate wiring opening

 

 

120 VAC

 

 

for hood control connection. See next page for RED wire HOUSE WIRING

14/3 CABLE

 

connection.

 

 

 

 

 

 

 

 

120 VAC POWER CABLE ENTERING THE SWITCH

 

 

 

 

2-ROCKER

 

 

SWITCH

 

 

 

 

RED

 

 

 

(motor)

GROUND

 

 

 

Install a 2-rocker switch at a convenient place for the

BLACK

 

14/3 CABLE

user. Feed the switch box with 120 VAC house wiring

 

 

TO HOOD

 

 

 

and use a 14/3 cable to wire it to the range hood (see

 

 

WHITE

diagram at right).

 

BLACK

 

 

 

(lights)

 

 

 

 

WHITE

 

 

 

120 VAC

 

 

 

LINE IN

Motor switch

Light switch

NOTE: Allow enough length of 14/3 cable to perform the RED wire

4

 

connection in the hood nose.

 

 

TO CONTROL PANEL

 

Insert the 14/3 cable in the hood through an UL approved wire

3

 

clamp. Connect ground wire to the GREEN ground screw.

2

 

 

 

 

MOTOR

 

Connect WHITE wire from 14/3 cable to WHITE wire from range

GROUND

 

WIRE

 

hood wiring using an appropriate wire nut.

 

 

 

Connect BLACK wire from 14/3 cable to BLACK wire from range

 

BLACK

 

WHITE

hood wiring using an appropriate wire nut.

 

1

RED

 

 

 

Run RED wire from 14/3 cable through bend plate wiring opening for

 

GROUND

 

 

hood control connection. See next page for RED wire connection.

 

 

 