AEG 8160D-AL-S Manual

0 (0)

8360 D/8390 D

8391 D

8160 D

Köksfläkt

Ventilator

Liesituuletin

Emhætte

Cooker Hood

Instruktionsbok

Bruksanvisning

Käyttöohje

Brugsvejledning

Operating and Installation Instructions

S

Innehållsfö rteckning .............................................................

2

N

Innholdsfortegnelse ............................................................

16

FIN

Sisällysluettelo ..................................................................

29

DK

Indholdsfortegnelse ............................................................

42

UK

Contents ............................................................................

56

Contents

 

Safety warnings ................................................................................

55

Description of the cooker hood ..........................................................

57

Introduction .......................................................................................

58

Using the cooker hood - 8160 D ........................................................

59

Using the cooker hood - 8360 D - 8390 D - 8391 D ............................

60

Maintenance and cleaning .................................................................

61

If the cooker hood will not operate .....................................................

64

Technical specifications ....................................................................

65

Installation ........................................................................................

66

Safety warnings

This appliance is to be used solely as a household appliance. It has been manufactured according to the international safety and quality standards. Note that the safety devices alone are not capable of eliminating all accident risks.

It is therefore very important to carefully read all the operating instructions, recommendations and warnings prior to installation and use of the appliance. Note in particular the text paragraphs with the danger triangle design, to avoid damages to persons or objects. Keep this instruction booklet in a safe place: this booklet should always accompany the appliance at such time as it is sold or given to other persons for use.

Installation and service

Any electrical installation of the cooker hood must be carried out by a qualified electrician and the hood itself must be installed by someone with experience. Installation made by an unqualified person can lead to loss of function of the cooker hood and possible damage to person and and/or property.

The cooker hood must be at least 50 cm above electric hobs or electric ranges, or at least 65 cm above gas burners or gas ranges.

Ensure that the power cable is not damaged during installation.

The cooker hood is only in stand by mode unless the plug or the fuse is disconnected.

The cooker hood cannot be connected to flues of other appliances that run on energy sources other than electricity. Please, keep to the provisions of official directives regarding fume discharge.

56

Use of cooker hood

This appliance is for domestic use only in a normal household.

Never leave any deep-frying, melting fat, paraffin or any other inflammable liquid unattended on the hob. In the event of fire: Immediately switch off the cooker hood and the cooker. Note! Cover the fire. Never use water.

Never do any flambécooking underneath the cooker hood. It can cause a fire. Remember that overheated fat may spontaneously ignite. Never leave the frying pan unattended.

It is essential that the grease filter is regularly cleaned to help avoid fat dripping on to the hot zone and causing a fire. Read the section on “Maintenance and Cleaning” in the instruction book.

Disposal

Prevent accidents when disposing of your cooker hood. Disconnect the power plug from the wall socket and cut the power cord at the hood inlet.Contact your local authority for information on where to dispose the cooker hood.

Description of the cooker hood

Functions

There are two possible systems:

Extraction of air to the outside using an optional venting kit and evacuation duct.

Recirculation using an optional charcoal filter.

The air outlet must not be connected to chimney flues or combustion gas ducts. The air outlet must under no circumstances be connected to ventilation ducts for rooms in which fuel-burning appliances are installed.

Accessories

The following are included with the cooker hood:

2 Tube clamps

1 hood canopy complete with controls, lighting and fan motor.

1 telescopic chimney stack formed by: U-shaped upper section and U-shaped lower section.

1 recirculation spigot.

1 plastic bag containing: 2 wall hooks to fix the canopy hood, 1 wall bracket to fix the chimney, rawl plugs, screws, and documentation.

The following can be ordered from your retailer:

Charcoal filter, KF8 (typ 150).

The carbon filter is to be used when the hood is connected to the recirculation mode.

57

AEG 8160D-AL-S Manual

Introduction

Extractor version

The hood is supplied as an extractor unit and can also be used with a filtering function by fitting one charcoal filter (special accessory).

You will need original AEG charcoal filter for this function (see Special Accessories).

The air is discharged to the outside through a pipe, which must be fitted to connection flange A. Fig. 1.

In order to obtain the best performance the hose should have a diameter equal to the outlet hole.

Fig. 1

Filter Version

The air is filtered through an charcoal filter and returned to the kitchen through the top grill of the outlet pipe.

You will need an original AEG KF8 charcoal filter for the filtering function. (See Special Accessories).

Fix the deflector using 2 screw Ø 2,9x13 mm. Fig. 2.

Optionally, the position of the chimney elements can be changed. When using the hood in the filter version the chimney must be fixed at the top, with the air outlet grill at the side.

Fig. 2

58

Using the cooker hood

The control panel - 8160 D

The hood is fitted with one motor having several speed. Best results are obtained by using a low speed for normal conditions and high speed when odours are more concentrated. Turn the hood on a few

minutes before you start cooking then you will get an underpressure in the kitchen. It should be left on after cooking for about 15 minutes or until all odours have disappeared.

The control switches are located on the unit’s front panel:

the light switch switches the hood lamp on and off.

the motor switch switches the cooking smoke and vapour extractor motor on and off, enabling you to select the speed.

Correct ventilation

If the cooker hood is to work correctly there must be an underpressure in the kitchen. It is important to keep the kitchen windows closed and have a window in an adjacent room open.

Important to know

Not applicable for recirculation. Great care must be taken if the hood is used at the same time as a burner or fireplace (e.g. gas, diesel, coal or wood heaters, water heaters, etc.), as the hood will expel air which is required by these other appliances. Attend to it by opening a window. The negative pressure in the room must not exceed 0,04 mbar to prevent fumes being drawn back into the room by the cooker hood.