ABB standard drives
ACS310, 0.37 to 22 kW / 0.5 to 30 Hp
ABB standard drives, ACS310,
are dedicated to variable torque
applications such as booster pumps
and centrifugal fans.
The drive design includes a powerful
set of features which benefit pump
and fan applications including builtin PID controllers and PFC (pump
and fan control) that varies the
drive’s performance in response to
changes in pressure, flow or other
external data. The drives also have
pre-programmed protection functions
such as pipe cleaning for preventive
maintenance.
The ACS310 drives provide built-in
energy efficiency features. Energy
savings can be easily monitored using
the built-in energy calculators, that
display energy savings in kilowatt hours
and saved carbon dioxide emissions.
The savings can also be displayed in
local currencies.
Among the energy efficiency calculators
is an energy optimizer that helps to
improve system’s energy efficiency while
operating at partial loads. Load analyzer
is a built-in statistical tool to analyze
the drive as well as motor dimensioning
and further analyze the process energy
efficiency and operation. Even the
drive’s internal fan is controlled by
software to reduce noise and losses,
improving energy efficiency.
These features, combined with preprogrammed application macros, an
intuitive user interface and several
assistant screens, speed up the
installation, parameter setting and
commissioning of the drive.
Highlights
− Pump and fan features such as pump
and fan control (PFC and SPFC)
− Pipe cleaning and fill functions
− Energy efficiency calculators
− Energy optimizer
− Load analyzer for optimized
dimensioning of the drive, motor and
process
− Embedded Modbus EIA-485 fieldbus
interface
− FlashDrop tool for fast parameter
setting
− Unified height and depth
− Full output current at 50 °C ambient
− Short parameter menu view
Voltage and power range
− 3-phase, 200 to 240 V ± 10%:
0.37 to 11 kW (0.5 to 15 hp)
− 3-phase, 380 to 480 V ± 10%:
0.37 to 22 kW (0.5 to 30 hp)
Applications
− Booster pumps
− Irrigation systems
− Level control
− Centrifugal fans
Options
− Basic and Assistant control panels
− FlashDrop tool for fast cold
configuration
− MREL-01 Relay output extension
module
− SREA-01 Ethernet adapter
− DriveWindow Light 2 PC tool
Technical data and types
Ratings Type designation Frame
P
P
N
kW
N
hp
3-phase supply voltage 200 to 240 V units
0.37 0.5 2.6 2.4 ACS310-03X-02A6-2 R0
0.55 0.75 3.9 3.5 ACS310-03X-03A9-2 R0
0.75 1 5.2 4.7 ACS310-03X-05A2-2 R1
1.1 1.5 7.4 6.7 ACS310-03X-07A4-2 R1
1.5 2 8.3 7.5 ACS310-03X-08A3-2 R1
2.2 3 10.8 9.8 ACS310-03X-10A8-2 R2
3 4 14.6 13.3 ACS310-03X-14A6-2 R2
4 5 19.4 17.6 ACS310-03X-19A4-2 R2
5.5 7.5 26.8 24.4 ACS310-03X-26A8-2 R3
7.5 10 34.1 31.0 ACS310-03X-34A1-2 R4
11 15 50.8 46.2 ACS310-03X-50A8-2 R4
3-phase supply voltage 380 to 480 V units
0.37 0.5 1.3 1.2 ACS310-03X-01A3-4 R0
0.55 0.75 2.1 1.9 ACS310-03X-02A1-4 R0
0.75 1 2.6 2.4 ACS310-03X-02A6-4 R1
1.1 1.5 3.6 3.3 ACS310-03X-03A6-4 R1
1.5 2 4.5 4.1 ACS310-03X-04A5-4 R1
2.2 3 6.2 5.6 ACS310-03X-06A2-4 R1
3 4 8.0 7.3 ACS310-03X-08A0-4 R1
4 5 9.7 8.8 ACS310-03X-09A7-4 R1
5.5 7.5 13.8 12.5 ACS310-03X-13A8-4 R3
7.5 10 17.2 15.6 ACS310-03X-17A2-4 R3
11 15 25.4 23.1 ACS310-03X-25A4-4 R3
15 20 34.1 31 ACS310-03X-034A-4 R4
18.5 25 41.8 38 ACS310-03X-41A8-4 R4
22 30 48.4 44 ACS310-03X-48A4-4 R4
1)
I2N maximum continuous output current at ambient temperature of +40 °C.
No overloadability, derating 1% for every additional 1 °C up to 50 °C.
2)
ILD continuous output current at max ambient temperature of +50 °C.
10% overloadability for one minute every ten minutes.
1)
I
2N
A
2)
I
LD
A
size
Mains connection
Voltage and power
connection
Frequency
Motor connection
Motor types
Voltage
Frequency
Switching frequency
Type of control
Serial communication
Fieldbus
Environmental limits
Degree of protection
Ambient temperature
Product compliance
Markings
Directives
Harmonics
EMC
3-phase, 200 to 240 V ± 10%:
0.37 to 11 kW (0.5 to 15 hp)
3-phase, 380 to 480 V ± 10%:
0.37 to 22 kW (0.5 to 30 hp)
48 to 63 Hz
Asynchoronous induction motors
3-phase, from 0 to U
supply
0 to 500 Hz
4, 8, 12 and 16 kHz (derated)
Scalar U/f
Linear, squared and user defi nable U/f profi les
Energy optimizer
Modbus RTU EIA-485 and EIA-232
Modbus TCP with SREA-01 option module
IP20 / Optional NEMA 1 enclosure
-10 to 50 ºC (14 to 122 ºF), no frost allowed
CE and C-Tick approvals
UL, cUL and GOST R
RoHS compliant
Low Voltage Directive 2006/95/EC
Machinery Directive 2006/42/EC
EMC Directive 2004/108/EC
For reducing THD in partial loads and to comply
with EN/IEC 61000-3-12 with external AC input
chokes
Class C3 (2
nd
environment unrestricted
distribution) built-in as standard
Class C2 and C1 with external optional EMC fi lters
3AUA0000051083 REV C EN 20.7.2010 #15135
Analog input 1
0 to 10 V
Reference voltage
+10 V DC, max 10 mA
Analog input 2
Aux. voltage output
+24 V DC, max. 200 mA
PROGRAMMABLE
DIGITAL INPUTS
DI5 can also be used
as a frequency input
Modbus RTU
(EIA-485)
FlashDrop
PE
L1
L2
L3
3-phase
power supply,
200 to
480 V AC
Input
choke
Screen
EMC
filter
8
1
SCR
S1
mA
AO
AI1
AI2
GND
V
ROCOM
RONC
RONO
DOSRC
DOOUT
DOGND
EMC
VAR
U2
V2
W2
2
AI1
3
GND
4
+10 V
5
AI2
6
GND
9
+24 V
10
GND
11
DCOM
12
DI1
13
DI2
14
DI3
15
DI4
16
DI5
23
SHIELD
24
J701
B
25
A
26
GND_A
PE
U1
V1
W1
Control panel
(RJ-45)
Analog output
0 to 20 mA
PROGRAMMABLE RELAY
AND DIGITAL OUTPUTS
Relay output
250 V AC / 30 V DC / 6 A
Digital/frequency output,
PNP transistor type
30 V DC, max. 100 mA
6
Output relay
module MREL-01
EMC filter grounding screw
Varistor grounding screw
Output
choke
M
3
~
AC motor
Typical I/O connections
ACS310: X1
9
Ramp
Const.
Fwd /
pair sel
Speed 1
DI configuration NPN connected (sink)
+ 24 V
Const.
speed 1
DI configuration PNP connected (source) with external power supply
Fwd/
Rev
0 V
Rev
Start /
Stop
Start/
Stop
10
11
12
13
14
15
16
ACS310: X1
+24 V
9
GND
10
DCOM
11
DI1
12
DI2
13
DI3
14
DI4
15
DI5
16
+24 V
GND
DCOM
DI1
DI2
DI3
DI4
DI5
For more information see catalog ABB standard drives, ACS310 (3AUA0000051082).
For more information please contact:
www.abb.com/drives
www.abb.com/drivespartners
© Copyright 2010 ABB. All rights reserved. Specifications subject to change