ABB ACS310 Product Flyer

ABB standard drives
ACS310, 0.37 to 22 kW / 0.5 to 30 Hp
ABB standard drives, ACS310, are dedicated to variable torque applications such as booster pumps and centrifugal fans.
The drive design includes a powerful set of features which benefit pump and fan applications including built­in PID controllers and PFC (pump and fan control) that varies the drive’s performance in response to changes in pressure, flow or other external data. The drives also have pre-programmed protection functions such as pipe cleaning for preventive maintenance.
The ACS310 drives provide built-in energy efficiency features. Energy savings can be easily monitored using the built-in energy calculators, that display energy savings in kilowatt hours and saved carbon dioxide emissions. The savings can also be displayed in local currencies.
Among the energy efficiency calculators is an energy optimizer that helps to improve system’s energy efficiency while operating at partial loads. Load analyzer is a built-in statistical tool to analyze the drive as well as motor dimensioning and further analyze the process energy efficiency and operation. Even the drive’s internal fan is controlled by software to reduce noise and losses, improving energy efficiency.
These features, combined with pre­programmed application macros, an intuitive user interface and several assistant screens, speed up the installation, parameter setting and commissioning of the drive.
Highlights
− Pump and fan features such as pump and fan control (PFC and SPFC)
− Pipe cleaning and fill functions
− Energy efficiency calculators
− Energy optimizer
− Load analyzer for optimized dimensioning of the drive, motor and process
− Embedded Modbus EIA-485 fieldbus interface
− FlashDrop tool for fast parameter setting
− Unified height and depth
− Full output current at 50 °C ambient
− Short parameter menu view
Voltage and power range
− 3-phase, 200 to 240 V ± 10%:
0.37 to 11 kW (0.5 to 15 hp)
− 3-phase, 380 to 480 V ± 10%:
0.37 to 22 kW (0.5 to 30 hp)
Applications
− Booster pumps
− Irrigation systems
− Level control
− Centrifugal fans
Options
− Basic and Assistant control panels
− FlashDrop tool for fast cold configuration
− MREL-01 Relay output extension module
− SREA-01 Ethernet adapter
− DriveWindow Light 2 PC tool
Technical data and types
Ratings Type designation Frame
P
P
N
kW
N
hp
3-phase supply voltage 200 to 240 V units
0.37 0.5 2.6 2.4 ACS310-03X-02A6-2 R0
0.55 0.75 3.9 3.5 ACS310-03X-03A9-2 R0
0.75 1 5.2 4.7 ACS310-03X-05A2-2 R1
1.1 1.5 7.4 6.7 ACS310-03X-07A4-2 R1
1.5 2 8.3 7.5 ACS310-03X-08A3-2 R1
2.2 3 10.8 9.8 ACS310-03X-10A8-2 R2 3 4 14.6 13.3 ACS310-03X-14A6-2 R2 4 5 19.4 17.6 ACS310-03X-19A4-2 R2
5.5 7.5 26.8 24.4 ACS310-03X-26A8-2 R3
7.5 10 34.1 31.0 ACS310-03X-34A1-2 R4 11 15 50.8 46.2 ACS310-03X-50A8-2 R4
3-phase supply voltage 380 to 480 V units
0.37 0.5 1.3 1.2 ACS310-03X-01A3-4 R0
0.55 0.75 2.1 1.9 ACS310-03X-02A1-4 R0
0.75 1 2.6 2.4 ACS310-03X-02A6-4 R1
1.1 1.5 3.6 3.3 ACS310-03X-03A6-4 R1
1.5 2 4.5 4.1 ACS310-03X-04A5-4 R1
2.2 3 6.2 5.6 ACS310-03X-06A2-4 R1 3 4 8.0 7.3 ACS310-03X-08A0-4 R1 4 5 9.7 8.8 ACS310-03X-09A7-4 R1
5.5 7.5 13.8 12.5 ACS310-03X-13A8-4 R3
7.5 10 17.2 15.6 ACS310-03X-17A2-4 R3 11 15 25.4 23.1 ACS310-03X-25A4-4 R3 15 20 34.1 31 ACS310-03X-034A-4 R4
18.5 25 41.8 38 ACS310-03X-41A8-4 R4 22 30 48.4 44 ACS310-03X-48A4-4 R4
1)
I2N maximum continuous output current at ambient temperature of +40 °C.
No overloadability, derating 1% for every additional 1 °C up to 50 °C.
2)
ILD continuous output current at max ambient temperature of +50 °C.
10% overloadability for one minute every ten minutes.
1)
I
2N
A
2)
I
LD
A
size
Mains connection
Voltage and power connection
Frequency
Motor connection
Motor types
Voltage
Frequency
Switching frequency
Type of control
Serial communication
Fieldbus
Environmental limits
Degree of protection
Ambient temperature
Product compliance
Markings
Directives
Harmonics
EMC
3-phase, 200 to 240 V ± 10%:
0.37 to 11 kW (0.5 to 15 hp) 3-phase, 380 to 480 V ± 10%:
0.37 to 22 kW (0.5 to 30 hp)
48 to 63 Hz
Asynchoronous induction motors
3-phase, from 0 to U
supply
0 to 500 Hz
4, 8, 12 and 16 kHz (derated)
Scalar U/f Linear, squared and user defi nable U/f profi les Energy optimizer
Modbus RTU EIA-485 and EIA-232 Modbus TCP with SREA-01 option module
IP20 / Optional NEMA 1 enclosure
-10 to 50 ºC (14 to 122 ºF), no frost allowed
CE and C-Tick approvals UL, cUL and GOST R RoHS compliant
Low Voltage Directive 2006/95/EC Machinery Directive 2006/42/EC EMC Directive 2004/108/EC
For reducing THD in partial loads and to comply with EN/IEC 61000-3-12 with external AC input chokes
Class C3 (2
nd
environment unrestricted distribution) built-in as standard Class C2 and C1 with external optional EMC fi lters
3AUA0000051083 REV C EN 20.7.2010 #15135
Analog input 1
0 to 10 V
Reference voltage
+10 V DC, max 10 mA
Analog input 2
Aux. voltage output
+24 V DC, max. 200 mA
PROGRAMMABLE
DIGITAL INPUTS
DI5 can also be used
as a frequency input
Modbus RTU
(EIA-485)
FlashDrop
PE
L1
L2
L3
3-phase power supply, 200 to 480 V AC
Input choke
Screen
EMC filter
8
1
SCR
S1
mA
AO
AI1
AI2
GND
V
ROCOM
RONC
RONO
DOSRC
DOOUT
DOGND
EMC
VAR
U2
V2
W2
2
AI1
3
GND
4
+10 V
5
AI2
6
GND
9
+24 V
10
GND
11
DCOM
12
DI1
13
DI2
14
DI3
15
DI4
16
DI5
23
SHIELD
24
J701
B
25
A
26
GND_A
PE
U1
V1
W1
Control panel (RJ-45)
Analog output 0 to 20 mA
PROGRAMMABLE RELAY AND DIGITAL OUTPUTS
Relay output 250 V AC / 30 V DC / 6 A
Digital/frequency output, PNP transistor type 30 V DC, max. 100 mA
6
Output relay module MREL-01
EMC filter grounding screw
Varistor grounding screw
Output choke
M
3
~
AC motor
Typical I/O connections
ACS310: X1
9
Ramp
Const.
Fwd /
pair sel
Speed 1
DI configuration NPN connected (sink)
+ 24 V
Const. speed 1
DI configuration PNP connected (source) with external power supply
Fwd/ Rev
0 V
Rev
Start / Stop
Start/ Stop
10
11
12
13
14
15
16
ACS310: X1
+24 V
9
GND
10
DCOM
11
DI1
12
DI2
13
DI3
14
DI4
15
DI5
16
+24 V
GND
DCOM
DI1
DI2
DI3
DI4
DI5
For more information see catalog ABB standard drives, ACS310 (3AUA0000051082).
For more information please contact:
www.abb.com/drives www.abb.com/drivespartners
© Copyright 2010 ABB. All rights reserved. Specifications subject to change without notice.
Loading...