Models:
APIF100 / APIF150 / APIF200
APIF300 / APIF100M / APIF150M / APIF200M /
APIF300 / APIF300M
Iron and Manganese Reduction Systems
At a Glance:
•Chemical Free Oxidation of Iron
•Bypass Valve
•Manganese Reduction (M Series)
Gas Reduction
Product Benefits:
•Premium water-efficient control valve manufactured from composite materials and designed to provide high flow rates over a wide range of applications. Provides long-lasting operation and is fully adjustable, allowing maximum flexibility for specific water conditions and usage patterns
•Chemical free process to reduce precipitated, ferrous (dissolved) or bacterial iron by air induction; provides cost-efficient operation and eliminates the use of harsh chemicals
•Media blend provides excellent depth filtration of precipitated iron while increasing pH to enhance iron reduction
•Bypass valve with state-of-the-art design features — Full flow bypass valve which incorporates four positions, including a diagnostic position that allows service personnel to work on a pressurized system, while still providing untreated bypass water to the residence. Its completely non-metallic, all-plastic design allows for easy access and serviceability without the need for tools
APIF200
Product Specifications:
|
Media1 |
Nominal |
Flow Rates2 |
System |
System |
Approximate |
||
Model* |
Capacity |
gpm (lpm) |
Shipping |
|||||
(Cu. Ft.) |
Height |
Diameter |
||||||
|
ppm-gal |
Service |
Backwash3 |
Weight |
||||
|
|
|
|
|||||
APIF100 / APIF100M |
1.0 |
30,000 |
6 (22.7) |
5.3 (20.1) |
53” (135 cm) |
10” (26 cm) |
143 lbs (64.9 kg) |
|
|
|
|
|
|
|
|
|
|
APIF150 / APIF150M |
1.5 |
45,000 |
7 (26.5) |
5.3 (20.1) |
63” (160 cm) |
10” (26 cm) |
186 lbs (84.4 kg) |
|
|
|
|
|
|
|
|
|
|
APIF200 / APIF200M |
2.0 |
60,000 |
9 (34.1) |
7.5 (28.4) |
63” (160 cm) |
12” (30 cm) |
257 lbs (116.6 kg) |
|
|
|
|
|
|
|
|
|
|
APIF300 / APIF300M |
3.0 |
90,000 |
12 (45.4) |
10 (37.9) |
74” (188 cm) |
14” (36 cm) |
353 lbs (160.2 kg) |
NOTES:
1.Replenishment of pH adjusting component of media may be required periodically, the frequency of which is dependant on raw water pH, manganese concentration and water consumption rate. Consult dealer for more information.
2.For satisfactory performance, indicated flow rates should not be exceeded. Flow rates are adequate for normal residential applications. Do not use Service rates when sizing commercial applications or if treated water is to supply a geothermal heat pump, swimming pool, etc.). Contact dealer before selecting equipment.
3.For system to operate properly, pumping rate of well pump MUST be sufficient to backwash unit at rate specified.
4.Pipe Size is 1” (2.5 cm).
5.If used to reduce hydrogen sulfide gas an air to water pressure tank must be included in the water system set up.
* The “M” in the Model Number indicates Manganese