Congratulations on the purchase of your new appliance.
You have selected a high-quality product.
The operating instructions are part of this product. They contain important
information on safety, usage and disposal. Before using the product, please
familiarise yourself with all operating and safety instructions. Use the product
only as described and for the range of applications specified. Retain these
operating instructions for future reference. Please also pass on these operating
instructions to any future owner.
Copyright
This documentation is protected by copyright.
Any copying or reproduction, including in the form of extracts, or any reproduction
of images (even in a modified state), is permitted only with the written authorisation of the manufacturer.
Limitation of liability
All technical information, data and instructions for the connection and operation
contained in these operating instructions correspond to the latest available at the
time of printing and, to the best of our knowledge, take into account our previous
experience and know-how.
No claims may be derived from the specifications, figures and descriptions in
these operating instructions.
The manufacturer assumes no liability for damages sustained in consequence of
non-adherence to the operating instructions, inappropriate use, improper repairs,
modifications undertaken without permission or the use of unauthorised spare
parts.
Proper use
■ 2 │ GB
The appliance is exclusively intended to dehumidify living spaces, basements or
storage areas with an ambient temperature of 5°C to 32°C. The appliance may
only be used indoors. The appliance is intended solely for personal and not
commercial use. Usage other than as described above is not permissible and
may result in injury and/or damage to the appliance. The manufacturer accepts
no liability for damage caused by improper application or usage. The risk is
borne solely by the user.
│IE│NI│
CY
SLE 200 A1
Warnings and warning symbols used
The following warnings are used in these operating instructions:
DANGER
A warning notice at this hazard level indicates an imminently
hazardous situation.
Failure to avoid this hazardous situation could result in serious injuries or even
death.
► Follow the instructions on this warning label to avoid the risk of death or
serious injury.
WARNING
A warning at this hazard level indicates a potentially hazardous
situation.
Failure to avoid this hazardous situation could result in injury.
► Follow the instructions in this warning notice to prevent injuries.
CAUTION
A warning at this hazard level indicates a risk of property
damage.
Failure to avoid this situation could result in property damage.
► Follow the instructions in this warning notice to prevent property damage.
NOTE
► A note provides additional information that will assist you in using the
appliance.
The following warning symbols are used on the appliance:
SLE 200 A1
SymbolMeaning
Caution! Risk of fire!
Observe operating instructions
Instruction manual, operating instructions
Service indicator, refer to the operating instructions
GB│IE│NI│CY
│
3 ■
Safety
This section contains important safety instructions for using the appliance. Improper use may result in personal injury and property damage.
Risk of electrocution
DANGER
Risk of fatal injury from electrocution!
Contact with live cables or components can result in
a fatal injury!
Please observe the following safety guidelines to prevent
electrical hazards.
► Do not use the appliance if the power cable or the plug
is damaged.
► There is a risk of electrocution if live connections are
touched and the electrical and mechanical structure
is changed.
Risk of electrocution due to moisture
DANGER
► Do not place the appliance in water, in water pooling
areas or puddles.
■ 4 │ GB
► Never operate the appliance near a bath tub, a shower,
a filled wash basin or similar structures.
► Do not immerse appliance, the cabling or the mains
plug in water or other fluids.
► Protect the appliance from water droplets or spray.
► In the event that liquid enters the appliance (apart from in
the water tank), disconnect the mains plug immediately. Arrange to have the appliance checked before using it again.
► Do not handle the appliance with damp hands.
► If the appliance falls into water, disconnect the mains
plug immediately. Do not attempt to remove the appliance before you have done so.
│IE│NI│
CY
SLE 200 A1
Danger of explosion/fire
DANGER
► Do not use the appliance in a potentially explosive
environment containing combustible liquids, gases or
dusts. Electrical appliances generate sparks that can
ignite the dust or fumes.
► The appliance contains extremely flammable gas under
pressure that may explode if heated.
► Keep the appliance away from heat, hot surfaces,
sparks, naked flames and other sources of ignition.
Do not smoke.
RISK OF FIRE!
► Do not use any items other than those permitted by the
manufacturer to speed up the defrosting process.
► The appliance may only be stored in rooms without
permanent sources of ignition (e.g. open flames, a
switched-on gas appliance or an electric heater).
► Do not drill or burn.
► Remember that refrigerants are odourless.
Risk of disease
DANGER
► The collected water is not suitable for drinking or
watering plants. There are potential health hazards.
SLE 200 A1
GB│IE│NI│CY
│
5 ■
WARNING: MATERIAL DAMAGE
► The appliance is not suitable for drying lagging. If insu-
lation or lagging materials are damp following a pipe
burst, consult an expert.
► Never expose the appliance to temperatures of 0°C
or lower. Residual water in the lines could freeze and
damage the system.
► Do not use the appliance in a dusty or chlorinated
environment.
Basic safety instructions
To ensure safe operation of the appliance, follow the safety
guidelines set out below:
■ Check the appliance for visible external damage before
use. Do not use an appliance that has been damaged or
dropped.
■ To avoid potential risks, damaged mains cables should
be replaced by the manufacturer, their customer service
department or a similarly qualified person.
■ 6 │ GB
■ Do not operate the appliance outdoors.
■ During operation, always keep windows and doors closed
so that the appliance can work effectively.
■ Do not operate the appliance in the proximity of highly
inflammable gases or materials, near naked flames or in
areas prone to oil and water splashing.
│IE│NI│
CY
SLE 200 A1
■ This appliance may be used by children aged 8 years and
above and by persons with limited physical, sensory or
mental capabilities or lack of experience and knowledge,
provided that they are under supervision or have been told
how to use the appliance safely and are aware of the potential risks. Do not allow children to use the appliance as a toy.
Cleaning and user maintenance tasks may not be carried
out by children unless under supervision.
■ All repairs must be carried out by authorised specialist
companies or by the Customer Service department. Improper
repairs can pose significant risks to the user. It will also
invalidate any warranty claims.
■ Do not expose the appliance to rain. Protect the appliance
against moisture and the ingress of fluids and objects into the
casing. Never immerse the appliance in water and do not
place objects containing fluids (e.g. vases) on the appliance.
The appliance could be irreparably damaged!
■ Do not place heavy objects on the appliance.
■ Do not cover the appliance (e.g. with newspapers, cushions
or blankets).
■ Do not insert any objects into the ventilation slits.
■ Avoid direct sunlight.
■ Do not place any naked flames, e.g. burning candles, on or
directly next to the appliance.
■ In the event of malfunctions, and in bad weather, disconnect
the plug from the mains power socket.
■ Ensure that the air inlet and air outlet opening remain free of
soiling during operation. Never cover the appliance!
■ Always place the appliance on a solid, flat surface so that it
cannot tip over.
SLE 200 A1
GB│IE│NI│CY
│
7 ■
■ Do not permanently install the appliance. Position the ap-
pliance so that its side panels have a clearance of at least
20cm from walls or other objects and ensure a clearance
of at least 50 cm from the front, rear and top panels of the
appliance in order to ensure good air circulation. Take care
not to obstruct the air inlet and outlet opening.
■ The appliance may only be operated in rooms with an ambi-
ent temperature of 5°C to 32°C.
■ Use the appliance only in rooms up to 16 m².
■ The appliance must be installed, operated and stored in a
room with a floor area greater than 4 m2.
■ If the appliance is operated in unventilated areas, these
must be designed in such a way that the refrigerant cannot
accumulate anywhere in the event of refrigerant leakage.
Otherwise, a combustible mixture may be formed.
■ The appliance may only be stored in rooms without perma-
nent sources of ignition (e.g. open flames, a switched-on gas
appliance or an electric heater).
■ The appliance must be stored in a way that does not dam-
age it.
■ 8 │ GB
■ Clean the air filter before it gets too badly contaminated.
■ While draining via a hose, ensure that it does not become
blocked and that the open end of the hose is positioned at a
lower level than the outlet aperture. The end of the hose must
be positioned above a drain.
■ Operate the appliance only together with the water tank or
with the hose installed.
│IE│NI│
CY
SLE 200 A1
■ Connect the safety plug only to a properly installed, easily
accessible plug socket with protected contacts, the voltage
of which corresponds to the specifications on the rating
plate. The plug socket must remain easily accessible even
after connection.
■ Before cleaning, always disconnect the mains plug from the
mains power socket.
■ Always transport, operate and store the appliance upright!
The water tank must be emptied before transport.
Use
Package contents and transport inspection
The appliance is supplied with the following components as standard:
▯ Dehumidifier
▯ Drainage hose
▯ EU garden hose adapter
▯ These operating instructions
NOTE
► Check the package for completeness and signs of visible damage.
► If any items are missing or damaged as a result of defective packaging or
transportation, please contact the Service Hotline (see section Service).
♦ Remove all packaging materials and all transport locks from the appliance.
SLE 200 A1
GB│IE│NI│CY
│
9 ■
Description of components
Fig. A
1 Carrying handle
2 Control panel
3 Air inlet
4 Plastic frame
5 Air filter
6 Water tank
7 Air outlet
8 Outlet opening
9 Stopper
0 Power cable
q Velcro tape
Fig. B
w Display
e
button
button
r
t button
button
z
Fig. C
u Drainage hose
i EU garden hose adapter
■ 10 │ GB
│IE│NI│
CY
SLE 200 A1
Before initial use
♦ Place the appliance on a flat, dry and solid surface.
♦ Leave the appliance in the operating position for approx. 30 minutes to
allow the refrigerant to settle.
♦ Check that the water tank 6 is correctly inserted.
♦ Insert the plug into a mains power socket. You will hear a beep.
Electrical connection
ATTENTION
► Before connecting the appliance, compare the specifications for the
required input voltage on the rating plate with the intended voltage source
for operation. This data must match to prevent damage to the appliance.
► The power cable must always be easily accessible, so that the appliance
can be quickly removed from the mains in the event of an emergency.
► Make sure that the power cable is not damaged and is not routed over any
hot surfaces and/or sharp edges; otherwise it will become damaged.
► Ensure that the power cable is not taut or kinked.
Guidelines for operation
■ If the air in your living spaces is constantly excessively humid, the cause should
be identified and addressed. Sustained – year-round – dehumidifying is
generally not a good idea.
■ The optimal ambient temperature for dehumidifying the air is 5°C to 32°C.
Using a dehumidifier at temperatures below 5°C is redundant, as there is little
humidity in the air.
■ During operation, the room temperature may increase by 1°C to 4°C, depending
on the size of the room. This is normal.
Automatic defrosting
To ensure that the appliance does not ice up during sustained operation, it defrosts
automatically. The defrosting function is activated automatically and cannot
be switched on manually. Do not switch off the appliance during automatic
defrosting and do not disconnect the mains plug from the mains socket. During
defrosting, appears on the displayw. Dehumidification is briefly paused,
but the fan continues to run. The duration of the defrosting process may vary. The
lower the ambient temperature, the earlier or more often the automatic defrosting
is activated. Once the defrosting process is complete, the appliance resumes
operation in the previously selected settings.
SLE 200 A1
GB│IE│NI│CY
│
11 ■
Handling and operation
This section provides you with important information on handling and using the
appliance.
Switching the appliance on/off
♦ Press the buttonz to switch on the appliance.
You will hear a beep and the selected programme ( or ) will appear
on the display w.
♦ Press the
You will hear a beep and the display w switches off.
NOTE
► The appliance always starts up with the last selected setting.
► If the appliance shuts down due to a power failure, it will automatically
restart with the last selected setting when power is restored.
♦ If a timer has been programmed, the appliance switches off permanently
after the specified time has elapsed (1–12 hours).
♦ If a relative humidity value has been set in the DEHUMIDIFICATION
programme, the appliance switches off once this value has been reached.
If the value is exceeded, the dehumidification switches back on again.
♦ When the water tank6 is full, incorrectly inserted or removed, dehumidifi-
cation stops. The appliance will beep for approx. 20 seconds and
appear on the displayw. The fan keeps going for approx. 3minutes and
then switches off.
buttonz to switch off the appliance.
will
■ 12 │ GB
│IE│NI│
CY
SLE 200 A1
Selecting programmes
The appliance has 2 programmes:
▯ DEHUMIDIFICATION (
▯ FAN (
♦ Press the
DEHUMIDIFICATION
This programme allows you to set the desired relative air humidity level that
should be achieved.
♦ Press the buttonr to set the desired relative humidity in 5% increments
You also have the option to select the
humidity below 30%. This setting allows you to achieve a very low relative
humidity as the dehumidification runs permanently.
♦ Press the buttonr repeatedly until is shown on the displayw.
NOTE
► Note that the values for the relative humidity have a tolerance of approx.±3%
► The minimum humidity that can be achieved in continuous dehumidification
)
button t repeatedly to select the desired programme. The
selected programme flashes for approx. 5 seconds and is then shown
permanently on the displayw.
between 30% and 80%. The set value flashes for approx. 5 seconds on the
display w and then the current programme () is shown again.
and that there may be a slight delay before the appliance itself/the dehumidification function switches on or off.
mode (
ambient temperature, etc. Therefore, it is not possible to define a generally
applicable minimum value.
) is dependent on many factors, such as the room size or the
)
setting if you want to set the relative
FAN
No dehumidification takes place in this programme. The room air is drawn in
through the air inlet3, passes through the filter5 and is discharged back into
the room through the air outlet7.
Select this programme if you want to circulate but not dehumidify the air in the
room.
SLE 200 A1
GB│IE│NI│CY
│
13 ■
Timer function
The appliance is equipped with a timer function that can be used with either of
the programmes. Switch-off times, ranging from 1 to 12 hours, can be selected.
Once the set time has elapsed, the appliance switches off permanently.
♦ While the appliance is running, press the
switch-off time between 1 and 12 hours. The selected switch-off time flashes
for approx. 5 seconds on the display w and then the current programme is
shown again. Additionally, a point appears on the right of the displayw,
above the
♦ To end the timer prematurely, press either the
until appears on the displayw or switch off the appliance with the
buttonz.
symbol. This indicates that the timer function has been activated.
Emptying the water tank
The water tank6 has a capacity of approx.2.2litres. When the water tank6
is full, the appliance will beep for approx. 20 seconds and will appear on
the displayw. The dehumidification stops, the fan continues to run for approx.
3 minutes and then switches off.
♦ Pull the water tank6 carefully out of the appliance using the grips on the
side (see figure 1).
buttone repeatedly to set a
buttone repeatedly
■ 14 │ GB
6
Fig. 1
♦ Tip out the water and replace the water tank6 into the appliance. The
appliance resumes operation with the previously selected programme after
around 3 minutes.
│IE│NI│
CY
SLE 200 A1
Permanent drainage
You can use the supplied drainage hoseu or the EU garden hose adapteri
to set up permanent drainage.
ATTENTION
► When setting up permanent drainage, make sure that the hose is not kinked
and that it runs downwards along its entire length. Otherwise, the water
may flow back into the appliance and damage it.
► Check the entire connection system regularly for leaks.
♦ Switch off the appliance and pull the stopper9 out of the outlet opening8.
♦ Connect either the supplied drainage hoseu or the EU garden hose
adapteri to the outlet opening8 (see figures2+3).
♦ If you are using the EU garden hose adapteri, screw a garden hose onto
the EU garden hose adapteri (see figure 3).
8
9
i
Fig. 2 Fig. 3
SLE 200 A1
u
ATTENTION
► Screw on the EU garden hose adapter hand-tight only.
Do not use a wrench as it could damage the EU garden hose adapteri.
NOTE
► Depending on the garden hose system you use, you may need an additional
adapter. These are available from specialist stores.
♦ Set up the appliance so that the end of the hose is positioned over a drain.
The open end of the hose must lie below the outlet opening8 of the appliance (i.e. the hose must have a downwards gradient).
GB│IE│NI│CY
│
15 ■
Cleaning
ATTENTION
Possible damage to the appliance.
► Do not allow any liquids or moisture to get into the appliance.
► Always remove the mains plug from the mains power socket before cleaning
the appliance.
► Do not use aggressive or abrasive cleaning agents, as they may corrode
the surface of the casing.
♦ If necessary, wipe the housing with a slightly damp cloth.
♦ Clean the ventilation openings regularly with a suitable soft brush to remove
dust and dirt.
♦ Remove the water tank6, pour out the water and dry it well inside and
outside before placing it back in the appliance.
♦ We recommend cleaning the water tank6 every two weeks to prevent
mould and bacteria. Fill the water tank6 with lukewarm water and add
some washing-up liquid. Rinse several times with lukewarm water. We also
recommend disinfection following cleaning.
To do this, use any standard commercial, alcohol-based disinfecting agent
or high-proof alcohol. Both substances are completely harmless if followed
by repeated rinsing with lukewarm water.
■ 16 │ GB
│IE│NI│
CY
SLE 200 A1
Clean air filter
The performance of the appliance also depends on how clean the air filter5 is.
The air filter5 should be cleaned every 2 weeks.
♦ Carefully pull the water tank6 out of the appliance using the grips on the
side.
♦ Guide the plastic frame4 with the air filter 5 inserted past the retaining
tabs of the housing and pull it downwards out of the appliance (see figure 4).
Fig. 4
♦ Vacuum the air filter5 or clean it with a soft brush.
♦ Place the plastic frame4 with the inserted air filter5 back in the appliance.
♦ Place the water tank6 back in the appliance.
5
4
Storage
SLE 200 A1
♦ Remove the plug from the mains power socket. Roll up the mains cable0
loosely and wrap the Velcro tapeq around it so that it does not become
a tripping hazard.
♦ Empty the water tank6 if you are not going to use the appliance for a
long time.
♦ Always store the appliance in upright position and in a dry and dust-free
environment out of direct sunlight.
GB│IE│NI│CY
│
17 ■
Troubleshooting
This section contains important information on fault identification and rectification.
Causes of malfunction and fault rectification
The following table will help you identify and rectify minor malfunctions:
FaultPossible causeRemedy
The appliance
will not switch
on.
The appliance
stops occasionally (the
fan switches
off).
The appliance
is producing
no or too little
condensate.
The ejected air
is warm.
appears
on the displayw.
appears
on the displayw.
The mains plug is not plugged in.
The mains socket is not supplying
any power.
The humidity of the room has
reached the desired level.
The ventilation openings are
dirty or covered.
The room's windows and doors
are open.
The appliance is running in the
FAN programme. Dehumidification is not taking place.
Heat exchange process
Temperature sensor/humidity
sensor error
The water tank6 is full.Empty the water tank6.
The water tank 6 is not inserted
properly.
Insert the plug into the mains power
socket.
Check the house mains fuse.
This is a normal feature of the
appliance.
Ensure that the air inlet and air
outlet openings are clean and
free of obstructions.
Close the windows and doors.
Select the DEHUMIDIFICATION
programme.
This is a normal feature of the
appliance.
Contact the Customer Service
department.
Insert the water tank6 into the
appliance correctly.
■ 18 │ GB
NOTE
► If the above-mentioned solutions do not resolve the problem, please contact
Customer Service (see section Service).
│IE│NI│
CY
SLE 200 A1
Loading...
+ 49 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.