Shure m62 schematic

0 (0)
Shure m62 schematic

 

 

 

 

 

 

 

 

 

222 HARTREY

AVE EVANSTON, ILL.

(60204) U.S.A.

 

 

M O D E L M 6 2

 

 

 

 

 

 

DATA SHEET

A U D I O L E V E L C O N T R O L L E R

 

 

AREA CODE

312/328-9000 CABLE

SHUREMICRO

 

 

C I R C U I T D I A G R A M

I

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ITEM

SHURE

DESCRIPTION

PART NO.

 

 

 

 

 

 

 

Q1,

Q2,

86A327

TRANSISTOR

Q3, Q4

Q5

86A325

TRANSISTOR

 

 

 

Q6

86A329

FET TRANSISTOR

 

 

 

 

D1

 

86A405

GERMANIUM DIODE

 

 

 

D2, D3, D4

8 6 A 4 0 3

SILICON DIODE

 

 

 

T1, T2

51A38

TRANSFORMER

 

 

 

 

NOTES:

1.ALL CAPACITORS IN MFD UNLESS SHOWN OTHERWISE AND WORKING VOLTAGES OVER 100 UNLESS SHOWN.

2.ALL RESISTORS 10% TOLERANCE.

3.THE SELECTED RESISTOR IS CHOSEN TO ADJUST POINT WHERE REGULATING ACTION STARTS TO CORRESPOND TO DISTANCE SELECTOR SWITCH SETTINGS.

M O D E L M 6 2

A U D I O L E V E L C O N T R O L L E R

AL331 (4-68) 27A514

 

Copyright 1968, Shure Brothers, Inc.

Printed In U.S.A.