The information presented in this manual is not warranted by the APC by
Schneider Electric to be authoritative, error free, or complete. This
publication is not meant to be a substitute for a detailed operational and site
specific development plan. Therefore, APC by Schneider Electric assumes
no liability for damages, violations of codes, improper installation, system
failures, or any other problems that could arise based on the use of this
Publication.
The information contained in this Publication is provided as is and has been
prepared solely for the purpose of evaluating data center design and
construction. This Publication has been compiled in good faith by APC by
Schneider Electric. However, no representation is made or warranty given,
either express or implied, as to the completeness or accuracy of the
information this Publication contains.
IN NO EVENT SHALL APC BY SCHNEIDER ELECTRIC, OR ANY
PARENT, AFFILIATE OR SUBSIDIARY COMPANY OF APC BY
SCHNEIDER ELECTRIC OR THEIR RESPECTIVE OFFICERS,
DIRECTORS, OR EMPLOYEES BE LIABLE FOR ANY DIRECT,
INDIRECT, CONSEQUENTIAL, PUNITIVE, SPECIAL, OR INCIDENTAL
DAMAGES (INCLUDING, WITHOUT LIMITATION, DAMAGES FOR LOSS
OF BUSINESS, CONTRACT, REVENUE, DATA, INFORMATION, OR
BUSINESS INTERRUPTION) RESULTING FROM, ARISING OUT, OR IN
CONNECTION WITH THE USE OF, OR INABILITY TO USE THIS
PUBLICATION OR THE CONTENT, EVEN IF APC BY SCHNEIDER
ELECTRIC HAS BEEN EXPRESSLY ADVISED OF THE POSSIBILITY OF
SUCH DAMAGES. APC BY SCHNEIDER ELECTRIC RESERVES THE
RIGHT TO MAKE CHANGES OR UPDATES WITH RESPECT TO OR IN
THE CONTENT OF THE PUBLICATION OR THE FORMAT THEREOF AT
ANY TIME WITHOUT NOTICE.
Copyright, intellectual, and all other proprietary rights in the content
(including but not limited to software, audio, video, text, and photographs)
rests with APC by Schneider Electric or its licensors. All rights in the content
not expressly granted herein are reserved. No rights of any kind are licensed
or assigned or shall otherwise pass to persons accessing this information.
This Publication shall not be for resale in whole or in part.
Room Monitor 355 Installation and Quick Configuration
Safety
Read the instructions carefully to become familiar with the equipment
before trying to assemble, operate, service or maintain it. The following
special messages may appear throughout this manual or on the
equipment to warn of potential hazards or to call attention to information
that clarifies or simplifies a procedure.
The addition of this symbol to a Danger or Warning safety
label indicates that an electrical hazard exists which will
result in personal injury if the instructions are not followed.
This is the safety alert symbol. It is used to alert you to
potential personal injury hazards. Obey all safety messages
that follow this symbol to avoid possible injury or death.
DANGER
Indicates an imminently hazardous situation which, if not avoided, will result
in death or serious injury.
WARNING
Indicates a potentially hazardous situation which, if not avoided, can result in
death or serious injury.
CAUTION
Indicates a potentially hazardous situation which, if not avoided, can result in
moderate injury.
NOTICE
Addresses practices not related to physical injury including certain
environmental hazards, potential damage or loss of data.
Safety Information for the Room Monitor 355
DANGER
HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH
• No user serviceable parts inside. Refer servicing to qualified personnel.
• Use indoors in a dry location.
Failure to follow these instructions will result in death or serious
injury.
Room Monitor 355 Installation and Quick Configuration
1
Introduction
The APC by Schneider Electric NetBotz® Room Monitor 355 functions
as the central hardware appliance for a NetBotz security and
environmental monitoring system. The Room Monitor 355 can be
installed anywhere in a room and includes an integrated camera and
internal sensors that monitor temperature, humidity, dew point, air flow,
and motion. It also includes four sensor ports for connecting
temperature, humidity, smoke, door, vibration, spot fluid, and third-party
dry contact and 0
following features:
• Image processor that generates images up to 1280 x 1024
resolution, 24-bit color, and up to 30 frames per second.
NOTE: The maximum frame rate describes the maximum number
of images that the camera imager is capable of producing each
second. The actual frame rate is dependent on the amount of
available bandwidth and current resolution.
• Image Size: 7.7 mm x 6.1 mm (9.82 mm diagonal = 0.39 in).
• Field of View: 64º (H) x 53º (V) for all resolutions.
• User adjustable and switchable industry-standard CS-mount lens.
CS-mount permits access to hundreds of different general
purpose and special purpose lenses.
ATTENTION: THE EQUIPMENT CONTAINS, AND THE
SOFTWARE ENABLES, VISUAL RECORDING
CAPABILITIES, THE IMPROPER USE OF WHICH MAY
SUBJECT YOU TO CIVIL AND CRIMINAL PENALTIES.
APPLICABLE LAWS REGARDING THE USE OF SUCH
CAPABILITIES VARY BETWEEN JURISDICTIONS AND MAY
REQUIRE AMONG OTHER THINGS EXPRESS WRITTEN
CONSENT FROM RECORDED SUBJECTS. YOU ARE
SOLELY RESPONSIBLE FOR INSURING STRICT
COMPLIANCE WITH SUCH LAWS AND FOR STRICT
ADHERENCE TO ANY/ALL RIGHTS OF PRIVACY AND
PERSONALTY. USE OF THIS SOFTWARE FOR ILLEGAL
SURVEILLANCE OR MONITORING SHALL BE DEEMED
UNAUTHORIZED USE IN VIOLATION OF THE END USER
SOFTWARE AGREEMENT AND RESULT IN THE
IMMEDIATE TERMINATION OF YOUR LICENSE RIGHTS
THEREUNDER.
–5 V sensors. The integrated camera includes the
2
Room Monitor 355 Installation and Quick Configuration
Document Overview
The NetBotz Room Monitor 355 Installation and Quick Configuration
Manual describes how to install a NetBotz Room Monitor 355, how to
connect devices to the appliance, and how to configure network
settings. After performing the configuration procedures in this manual,
you can access your system through the software interface, perform
additional configuration tasks, and begin monitoring the environment.
Additional Documentation
Unless otherwise noted, the following documentation is available on the
applicable product page on the APC by Schneider Electric website,
www.apc.com. To quickly find a product page, enter the product name
or part number in the search field.
NetBotz Appliance User Guide: Includes all details for using, managing,
and configuring a NetBotz system with one of the following appliances:
NetBotz Room Monitor 355 (NBWL0355/NBWL0355A), NetBotz Rack
Monitor 450 (NBRK0450), NetBotz Room Monitor 455 (NBWL0455/
NBWL0455A), NetBotz Rack Monitor 550 (NBRK0550), or NetBotz
Rack Monitor 570 (NBRK0570).
Additional Options
The following options are available for the Room Monitor 355. For more
information about any of the options, contact your APC by Schneider
Electric representative or the distributor from whom you purchased your
APC by Schneider Electric product.
• Temperature Sensor (AP9335T)
• Temperature/Humidity Sensor (AP9335TH)
• NetBotz Spot Fluid Sensor (NBES0301)
• NetBotz Door Switch Sensor for Rooms or Third Party Racks
(NBES0302)
• NetBotz Door Switch Sensor for APC by Schneider Electric Racks
(NBES0303)
• NetBotz Dry Contact Cable (NBES0304)
• NetBotz 0–5 V Cable (NBES0305)
• NetBotz Vibration Sensor (NBES0306)
• NetBotz Smoke Sensor (NBES0307)
StruxureWare Certified
This product is certified for use in StruxureWare® systems.
Room Monitor 355 Installation and Quick Configuration
3
Physical Description
1
0
/
1
0
0
!
aem0 203a
Front
ItemDescription
Vented internal
sensors
Network link
LED
Vented opening for airflow, temperature, and humidity
sensors.
Shows the status of the network connection. Blinks to
indicate network traffic (green = connected at 10 Mbps;
yellow = connected at 100 Mbps).
Power LEDIndicates whether the unit is receiving power
Camera LEDBlinks steadily when the integrated camera is active.
Alert LEDIndicates the alert status of the system. When more than
(green = receiving power; dark = not receiving power).
one alert exists, the most severe will be indicated.
• Flashing once every eight seconds = Informational
• Flashing once every four seconds = Warning
• Flashing once every two seconds = Error
• Flashing once every second = Critical
• Flashing twice per second = Failure
Temperature
display
• Displays the current temperature from 0 to 99 in
Centigrade or Fahrenheit. The Temperature reading
comes from the internal temperature sensor. If the
temperature exceeds 99, the display will flash 99.
• When the unit first receives power, displays the unique
identifier number for one minute.
• If an alert exists, flashes at the same rate as the Alert LED.
• During a firmware upgrade, displays 88.
Lens housingMust be removed to change the focus of the integrated
camera.
4
Room Monitor 355 Installation and Quick Configuration
Rear
S
E
N
S
O
R
S
1
0
/
1
0
0
1
3
2
4
a
e
m
0
2
0
4
a
ItemDescription
Sensor ports
(4)
Used for connecting APC by Schneider Electric sensors,
third-party dry-contact sensors, and standard third-party
0–5 V sensors. Third-party dry-contact state sensors
require the NetBotz Dry Contact Cable (NBES0304).
Standard third-party 0–5 V sensors require the NetBotz
0–5 V Sensor Cable (NBES0305).
10/100 Base-T
network port
Provides for a 10/100 Base-T network connection and
power through Power-over-Ethernet (PoE). (The appliance
operates at 100 Base-T only.) Status and link LEDs
indicate network traffic:
• Status LED: blinks orange and green at start-up, then
indicates the status of the network connection
(solid green = IP address established;
blinking green = attempting to obtain an IP address).
• Link LED: blinks to indicate network traffic
(green = connected at 10 Mbps;
orange = connected at 100 Mbps).
USB portUsed to configure the appliance.
ResetUsed to restart the appliance.
Room Monitor 355 Installation and Quick Configuration
5
Inventory
ae m028 6b
Inspect the contents of the package to ensure that the parts included
match those shown below. Report missing or damaged contents to APC
by Schneider Electric or your APC by Schneider Electric reseller.
However, if damage was due to shipping, immediately report the
damage to the shipping agent.
The shipping and packaging materials are recyclable. Please save them
for later use or dispose of them appropriately.
ItemDescriptionItemDescription
Bracket mounting plate for
electrical boxes
Adhesive cable tie holders
Mounting screw wall anchors
13 mm (0.5 in) machine screws
(for electrical box)
19 mm (0.75 in) sheet metal
screws (for wall or enclosure)
T-bar mounting plate
203 mm (8 in) tie wrap
6
Room Monitor 355 Installation and Quick Configuration
Ball-joint adjuster arms
Extender arm set screw
Cable retainer
Allen wrench
Rubber bracket cover
Mounting plate
Extender arm