Schneider Electric ILA1R, ILA1F, ILA1B User Manual

ILA1B, ILA1F, ILA1R

Lexium Integrated Drive Product manual
V2.00, 09.2008
0198441113562, V2.00, 09.2008
Important information ILA1B, ILA1F, ILA1R
This manual is part of the product.
Carefully read this manual and observe all instructions.
Keep this manual for future reference.
Hand this manual and all other pertinent product documentation over to all users of the product.
Carefully read and observe all safety instructions and the chapter "Be­fore you begin - safety information".
Some products are not available in all countries. For information on the availability of products, please consult the cata­log.
Subject to technical modifications without notice.
All details provided are technical data which do not constitute warranted qualities.
Most of the product designations are registered trademarks of their re­spective owners, even if this is not explicitly indicated.
2 Lexium Integrated Drive
0198441113562, V2.00, 09.2008
ILA1B, ILA1F, ILA1R Table of Contents

Table of Contents

Important information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Table of Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Writing conventions and symbols. . . . . . . . . . . . . . . . . . . . . . . 9
1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
1.1 About this manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
1.2 Unit overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
1.3 Components and interfaces . . . . . . . . . . . . . . . . . . . . . 12
1.3.1 Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
1.3.2 Interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
1.4 Name plate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
1.5 Type code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
1.6 Documentation and literature references . . . . . . . . . . . 17
1.7 Declaration of conformity. . . . . . . . . . . . . . . . . . . . . . . . 18
1.8 TÜV certificate for functional safety. . . . . . . . . . . . . . . . 19
2 Before you begin - safety information. . . . . . . . . . . . . . . . . . . 21
2.1 Qualification of personnel . . . . . . . . . . . . . . . . . . . . . . . 21
2.2 Intended use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
2.3 Hazard categories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
2.4 Basic information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
2.5 Functional safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
2.6 Standards and terminology . . . . . . . . . . . . . . . . . . . . . . 25
3 Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
3.1 Certifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
3.2 Ambient conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
3.3 Mechanical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
3.3.1 Degree of protection . . . . . . . . . . . . . . . . . . . . . . . . . 29
3.3.2 Mounting position . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
3.3.3 Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
3.4 Electrical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
3.4.1 Supply Voltage VDC at CN1. . . . . . . . . . . . . . . . . . . 32
3.4.2 Fieldbus at CN2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
3.4.3 Reference value supply to CN2 . . . . . . . . . . . . . . . . 33
3.4.4 Fieldbus at CN3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
3.4.5 24V signals to CN4. . . . . . . . . . . . . . . . . . . . . . . . . . 33
3.4.6 STO safety function at CN5 and CN6. . . . . . . . . . . . 33
0198441113562, V2.00, 09.2008
Lexium Integrated Drive 3
Table of Contents ILA1B, ILA1F, ILA1R
3.5 Conditions for UL 508C . . . . . . . . . . . . . . . . . . . . . . . . 34
4 Basics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
4.1 Functional safety. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
5 Engineering. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
5.1 External power supply units . . . . . . . . . . . . . . . . . . . . . 37
5.1.1 Supply voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
5.2 Ground design . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
5.3 Safety function STO ("Safe Torque Off"). . . . . . . . . . . . 40
5.3.1 Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
5.3.2 Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
5.3.3 Requirements for using the safety function . . . . . . . 41
5.3.4 Application examples STO. . . . . . . . . . . . . . . . . . . . 43
5.4 Monitoring functions . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
6 Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
6.1 Electromagnetic compatibility, EMC . . . . . . . . . . . . . . . 46
6.2 Mechanical installation . . . . . . . . . . . . . . . . . . . . . . . . . 47
6.3 Electrical installation . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
6.3.1 Wiring examples . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
6.3.2 Overview of all connections . . . . . . . . . . . . . . . . . . . 51
6.3.3 Connection via cable entry. . . . . . . . . . . . . . . . . . . . 52
6.3.4 Connection with industrial connectors . . . . . . . . . . . 55
6.3.5 Connection of VDC supply voltage . . . . . . . . . . . . . 55
6.3.6 PROFIBUS DP connection . . . . . . . . . . . . . . . . . . . 58
6.3.7 CAN connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
6.3.8 RS485 connection . . . . . . . . . . . . . . . . . . . . . . . . . . 64
6.3.9 24V signal interface connection. . . . . . . . . . . . . . . . 69
6.3.10 Connection of STO safety function . . . . . . . . . . . . . 70
6.3.11 Connection of reference signals for CAN or RS485. 72
6.3.12 Connection of reference signals for PROFIBUS DP 74
6.4 Connection accessories . . . . . . . . . . . . . . . . . . . . . . . . 77
6.4.1 Accessory "Insert kit, 3x I/O" . . . . . . . . . . . . . . . . . . 77
6.4.2 Accessory "Insert kit, 2x I/O, 1x STO in" . . . . . . . . . 77
6.4.3 Accessory "Insert kit, 1x STO in, 1x STO out" . . . . . 77
6.4.4 Accessory "Insert kit, 4x I/O, 1x STO in, 1x STO out" . . 78
6.5 Checking wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
7 Commissioning. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81
7.1 Preparing for commissioning . . . . . . . . . . . . . . . . . . . . 82
7.2 Running commissioning . . . . . . . . . . . . . . . . . . . . . . . . 83
7.2.1 First setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83
7.2.2 Starting 24V signal interface . . . . . . . . . . . . . . . . . . 84
7.2.3 Setting parameters for encoder . . . . . . . . . . . . . . . . 88
4 Lexium Integrated Drive
0198441113562, V2.00, 09.2008
ILA1B, ILA1F, ILA1R Table of Contents
7.2.4 Testing safety functions . . . . . . . . . . . . . . . . . . . . . . 90
7.2.5 Releasing the holding brake manually . . . . . . . . . . . 90
7.2.6 Testing with relative positioning . . . . . . . . . . . . . . . . 91
7.2.7 Optimizing the motor behavior . . . . . . . . . . . . . . . . . 92
7.3 Lexium CT commissioning software . . . . . . . . . . . . . . . 94
7.3.1 Firmware update via fieldbus . . . . . . . . . . . . . . . . . . 95
7.4 Controller optimization with step response . . . . . . . . . . 96
7.4.1 Controller structure . . . . . . . . . . . . . . . . . . . . . . . . . . 96
7.4.2 Checking and optimizing default settings . . . . . . . . . 97
7.4.3 Optimization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 98
7.4.4 Optimizing the speed controller . . . . . . . . . . . . . . . . 99
7.4.5 Setting the Posicast filter . . . . . . . . . . . . . . . . . . . . 102
7.4.6 Optimizing the position controller . . . . . . . . . . . . . . 103
8 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105
8.1 Basics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105
8.1.1 Default parameter values . . . . . . . . . . . . . . . . . . . . 105
8.1.2 External monitoring signals . . . . . . . . . . . . . . . . . . 105
8.1.3 Positioning limits. . . . . . . . . . . . . . . . . . . . . . . . . . . 107
8.1.4 Internal monitoring signals . . . . . . . . . . . . . . . . . . . 108
8.1.5 Operating states and state transitions . . . . . . . . . . 111
8.1.6 Operating-mode-specific status information . . . . . . 112
8.1.7 Other status information . . . . . . . . . . . . . . . . . . . . . 113
8.2 Operating modes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114
8.2.1 Operating mode Jog . . . . . . . . . . . . . . . . . . . . . . . . 116
8.2.2 Operating mode Profile velocity . . . . . . . . . . . . . . . 118
8.2.3 Operating mode Profile position . . . . . . . . . . . . . . . 120
8.2.4 Operating mode Homing. . . . . . . . . . . . . . . . . . . . . 122
8.2.5 Operating mode Electronic gear. . . . . . . . . . . . . . . 129
8.3 Functions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133
8.3.1 Definition of the direction of rotation . . . . . . . . . . . . 133
8.3.2 Motion profile . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133
8.3.3 Quick Stop . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 134
8.3.4 Programmable inputs and outputs . . . . . . . . . . . . . 135
8.3.5 Fast position capture . . . . . . . . . . . . . . . . . . . . . . . 139
8.3.6 Standstill window . . . . . . . . . . . . . . . . . . . . . . . . . . 141
8.3.7 Function of the holding brake . . . . . . . . . . . . . . . . . 142
9 Diagnostics and troubleshooting . . . . . . . . . . . . . . . . . . . . . 145
9.1 Error indication and troubleshooting . . . . . . . . . . . . . . 145
9.1.1 Diagnostics via commissioning software . . . . . . . . 145
9.1.2 Diagnostics via fieldbus . . . . . . . . . . . . . . . . . . . . . 145
9.1.3 Operation state and error indication . . . . . . . . . . . . 150
9.1.4 Reset error message . . . . . . . . . . . . . . . . . . . . . . . 150
9.1.5 Error classes and error response . . . . . . . . . . . . . . 151
9.1.6 Causes of errors and troubleshooting. . . . . . . . . . . 151
9.2 Overview of error numbers . . . . . . . . . . . . . . . . . . . . . 154
0198441113562, V2.00, 09.2008
Lexium Integrated Drive 5
Table of Contents ILA1B, ILA1F, ILA1R
10 Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 157
10.1 Representation of parameters . . . . . . . . . . . . . . . . . . 157
10.2 Overview Parameters . . . . . . . . . . . . . . . . . . . . . . . . . 158
10.3 Parameter groups. . . . . . . . . . . . . . . . . . . . . . . . . . . . 159
10.3.1 Parameter group "CAN" . . . . . . . . . . . . . . . . . . . . . 159
10.3.2 Parameter group "Capture" . . . . . . . . . . . . . . . . . . 159
10.3.3 Parameter group "Commands" . . . . . . . . . . . . . . . 160
10.3.4 Parameter group "Config" . . . . . . . . . . . . . . . . . . . 161
10.3.5 Parameter group "Control". . . . . . . . . . . . . . . . . . . 163
10.3.6 Parameter group "ErrMem0" . . . . . . . . . . . . . . . . . 163
10.3.7 Parameter group "Gear". . . . . . . . . . . . . . . . . . . . . 164
10.3.8 Parameter group "Homing" . . . . . . . . . . . . . . . . . . 165
10.3.9 Parameter group "I/O" . . . . . . . . . . . . . . . . . . . . . . 166
10.3.10 Parameter group "Manual". . . . . . . . . . . . . . . . . . . 167
10.3.11 Parameter group "Motion" . . . . . . . . . . . . . . . . . . . 168
10.3.12 Parameter group "Profibus" . . . . . . . . . . . . . . . . . . 168
10.3.13 Parameter group "ProgIO0" . . . . . . . . . . . . . . . . . . 169
10.3.14 Parameter group "PTP" . . . . . . . . . . . . . . . . . . . . . 170
10.3.15 Parameter group "RS485" . . . . . . . . . . . . . . . . . . . 171
10.3.16 Parameter group "Settings" . . . . . . . . . . . . . . . . . . 172
10.3.17 Parameter group "Status" . . . . . . . . . . . . . . . . . . . 173
10.3.18 Parameter group "VEL" . . . . . . . . . . . . . . . . . . . . . 177
11 Accessories and spare parts . . . . . . . . . . . . . . . . . . . . . . . . . 179
11.1 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 179
11.2 Gearboxes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 180
12 Service, maintenance and disposal . . . . . . . . . . . . . . . . . . . . 181
12.1 Service address . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 182
12.2 Maintenance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 182
12.2.1 Lifetime STO safety function . . . . . . . . . . . . . . . . . 182
12.3 Replacing units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 183
12.4 Shipping, storage, disposal. . . . . . . . . . . . . . . . . . . . . 183
6 Lexium Integrated Drive
0198441113562, V2.00, 09.2008
ILA1B, ILA1F, ILA1R Table of Contents
13 Glossary. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 185
13.1 Units and conversion tables . . . . . . . . . . . . . . . . . . . . 185
13.1.1 Length. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 185
13.1.2 Mass . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 185
13.1.3 Force. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 185
13.1.4 Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 185
13.1.5 Rotation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 186
13.1.6 Torque. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 186
13.1.7 Moment of inertia . . . . . . . . . . . . . . . . . . . . . . . . . . 186
13.1.8 Temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 186
13.1.9 Conductor cross section . . . . . . . . . . . . . . . . . . . . . 186
13.2 Terms and Abbreviations. . . . . . . . . . . . . . . . . . . . . . . 187
14 Index. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 189
0198441113562, V2.00, 09.2008
Lexium Integrated Drive 7
Table of Contents ILA1B, ILA1F, ILA1R
8 Lexium Integrated Drive
0198441113562, V2.00, 09.2008
ILA1B, ILA1F, ILA1R Writing conventions and symbols

Writing conventions and symbols

Work steps If work steps must be performed consecutively, this sequence of steps
is represented as follows:
쮿 Special prerequisites for the following work stepsStep 1Specific response to this work stepStep 2
If a response to a work step is indicated, this allows you to verify that the work step has been performed correctly.
Unless otherwise stated, the individual steps must be performed in the specified sequence.
Bulleted lists The items in bulleted lists are sorted alphanumerically or by priority. Bul-
leted lists are structured as follows:
Item 1 of bulleted list
Item 2 of bulleted list –Subitem for 2 –Subitem for 2
Item 3 of bulleted list
Making work easier Information on making work easier is highlighted by this symbol:
Sections highlighted this way provide supplementary information on making work easier.
Parameters Parameters are shown as follows:
Gruppe.Name Index:Subindex
SI units SI units are the original values. Converted units are shown in brackets
behind the original value; they may be rounded.
Example: Minimum conductor cross section: 1.5 mm
2
(AWG 14)
0198441113562, V2.00, 09.2008
Lexium Integrated Drive 9
Writing conventions and symbols ILA1B, ILA1F, ILA1R
10 Lexium Integrated Drive
0198441113562, V2.00, 09.2008

ILA1B, ILA1F, ILA1R 1 Introduction

1 Introduction

1.1 About this manual

This manual is valid for all ILA1B, ILA1F, ILA1R standard products. This chapter lists the type code for this product. The type code can be used to identify whether your product is a standard product or a customized model.

1.2 Unit overview

Figure 1.1 Device overview
The "Lexium Integrated Drive" consists of a motor and integrated elec­tronics. The product integrates interfaces, control electronics, a holding brake (optional) and the power stage.
Reference value supply The "Lexium Integrated Drive" moves the motor according to the com-
mands recieved by a fieldbus master, e.g. a PLC or a PC.
Safety function The integrated safety function STO (IEC 61800-5-2) meets the require-
ments of Safety Integrity Level SIL2. The safety function allows for a cat­egory 0 stop as per EN 60204-1 without external power contactors. It is not necessary to interrupt the supply voltage. This reduces the system costs and the response times.
The STO safety function is available as of device revision RS10 (see nameplate).
Using the library considerably facilitates controlling the device. The library is available for download from the Internet.
http://www.schneider-electric.com
0198441113562, V2.00, 09.2008
Lexium Integrated Drive 11
1 Introduction ILA1B, ILA1F, ILA1R

1.3 Components and interfaces

6 75
1
2
5
6
7
3
4
8
9
12
11
10
Figure 1.2 Components and interfaces
(1) Synchronous AC servo motor (2) Holding brake (optional) (3) Encoder (4) Electronics housing (5) Insert for sealing (accessory) (6) Insert with cable entry (accessory) (7) I/O insert with industrial connector (accessory) (8) Switches for settings (9) Cover of electronics housing, must not be removed (10) Cover of connector housing, to be removed for installation (11) Cover with industrial connector for Vdc supply voltage and IN/
OUT fieldbus connection (optional)
(12) Electrical interfaces
12 Lexium Integrated Drive
0198441113562, V2.00, 09.2008
ILA1B, ILA1F, ILA1R 1 Introduction

1.3.1 Components

Motor The motor is a brushless AC synchronous servo motor with 3-phase
technology. The motor has a high power density due to the use of the lat­est magnetic materials and an optimized design.
Encoder The standard drive system operates with a singleturn encoder.
The singleturn encoder has an internal resolution of 16384 increments per revolution.
The drive system can optionally be equipped with a multiturn encoder. The multiturn encoder covers a range of 4096 motor revolutions.
Electronics The electronic system comprises control electronics and power stage.
They have a common power supply and are not galvanically isolated.
The drive can be parameterized and controlled via the fieldbus interface.
4 digital 24V signals are also available. Each of them can be used as an input or output.
Holding brake The drive can optionally be equipped with an integrated holding brake.
The holding brake is controlled automatically.
0198441113562, V2.00, 09.2008
Lexium Integrated Drive 13
1 Introduction ILA1B, ILA1F, ILA1R

1.3.2 Interfaces

Standard available interfaces:
Supply voltage VDC The supply voltage VDC supplies the control electronics and the power
stage.
The ground connections of all interfaces are galvanically connected. For more information see chapter 5.2 "Ground design". This chapter also provides information on protection against reverse polarity.
Fieldbus interface Functions:
Profibus DP connection
CAN bus connection
RS485 bus connection The fieldbus interface is used for parameterizing and controlling the
drive. The fieldbus interface allows the drive to be integrated into a field­bus network and controlled by a master such as a PLC.
The drive can be commissioned via any of the above interfaces. This re­quires, for example, a PC with a suitable fieldbus converter (e.g. USB­CAN). The commissioning software is available for PCs; it supports the various fieldbus versions.
The firmware can be updated via any of the interfaces.
24 V signal interface 4 digital 24V signals are available. Each of them can be used as an input
or outputs.
The 24V signals are availab le to the master controller. However, it is also possible to parameterize special functions such as connection of limit switches.
14 Lexium Integrated Drive
0198441113562, V2.00, 09.2008
ILA1B, ILA1F, ILA1R 1 Introduction

1.4 Name plate

The nameplate contains the following data:
1 2 3 4 5 6 7
Figure 1.3 Nameplate
IL ...
I ...
U
N
M
N
I
max
n
N
DOM
Insulation class T
ambmax
PR
ID SN
Rev
made in Germany
(1) Type code (2) Type code (old designation) (3) Nominal voltage (4) Nominal torque (5) Maximum input current (6) Nominal speed (7) Date of manufacture (8) Thermal class (9) Maximum ambient air temperature (10) Software revision (11) Hardware revision (12) Firmware number (13) Material number (14) Serial Number
RS
8
9
10
USC
11 12 13 14
0198441113562, V2.00, 09.2008
Lexium Integrated Drive 15
1 Introduction ILA1B, ILA1F, ILA1R

1.5 Type code

ILA 1F57 1PB1A0--
Motor
ILA = Servo motor
Supply voltage
1 = 24 ... 36 V
Communication interface
B = PROFIBUS DP F = CANopen DS301 R = RS485
Size
57 = 57 mm
DC
Length
1 = 1 stack 2 = 2 stacks
Winding
P = Medium speed of rotation/medium torque T = High speed of rotation/low torque
Connection version
B = Printed circuit board connector C = Industrial connector
Position capture
1 = Servo Singleturn 2 = Servo Multiturn
Holding brake
A = Without holding brake F = With holding brake
Gearbox
0 = Without gearbox
1)
.
2)
Reserved
1) Not available in combination with the holding brake option
2) Not available in combination with the servo multiturn option.
Customized product In the case of a customized product, position 9 is an "S".
Positions 10 ... 13 are the number of the customized product.
Example: IL••••••S1234--
16 Lexium Integrated Drive
0198441113562, V2.00, 09.2008
ILA1B, ILA1F, ILA1R 1 Introduction

1.6 Documentation and literature references

The following manuals belong to this product:
Product manual, describes the technical data, installation, com­missioning and all operating modes and functions.
Fieldbus manual, description required to integrate the product into a fieldbus.
Source product manuals The current product manuals are available for download from the Inter-
net.
http://www.schneider-electric.com
Source EPLAN Macros For easier engineering, macro files and product master data are availa-
ble for download from the Internet at:
http://www.schneider-electric.com
Additional literature We recommend the following literature for more in-depth information:
Ellis, George: Control System Design Guide. Academic Press
Kuo, Benjamin; Golnaraghi, Farid: Automatic Control Systems. John Wiley & Sons
0198441113562, V2.00, 09.2008
Lexium Integrated Drive 17
1 Introduction ILA1B, ILA1F, ILA1R

1.7 Declaration of conformity

SCHNEIDER ELECTRIC MOTION DEUTSCHLAND GmbH & Co. KG
Breslauer Str. 7 D-77933 Lahr
EC DECLARATION OF CONFORMITY
EAR 2008
Y
according to EC Directive Machinery 98/37/EC according to EC Directive EMC 2004/108/EC according to EC Directive Low Voltage 2006/95/EC
We declare that the products listed below meet the requirements of the mentioned EC Directives with respect to design, construction and version distributed by us. This declaration becomes invalid with any modification on the products not authorized by us.
Designation: Motors with integrated control electronics
Type: ILA, ILE, ILS
Product number: 0x6600xxxxxxx, 0x6610xxxxxxx, 0x66206xxxxxx, 0x66307xxxxxx
0x6640xxxxxxx, 0x66606xxxxxx, 0x66707xxxxxx
Applied harmonized standards, especially:
EN ISO 13849-1:2006, Performance Level "d" (category 3) EN 61800-3:2004, second environment EN 62061:2005, SILcl 2 EN 61508:2001, SIL 2
Applied national standards
UL 508C Product documentation
and technical specifications, especially:
Company stamp:
Date/ Signature: 10 July 2008
Name/ Department: Wolfgang Brandstätter/Development
18 Lexium Integrated Drive
0198441113562, V2.00, 09.2008
ILA1B, ILA1F, ILA1R 1 Introduction

1.8 TÜV certificate for functional safety

0198441113562, V2.00, 09.2008
Lexium Integrated Drive 19
1 Introduction ILA1B, ILA1F, ILA1R
20 Lexium Integrated Drive
0198441113562, V2.00, 09.2008

ILA1B, ILA1F, ILA1R 2 Before you begin - safety information

2 Before you begin - safety information

2.1 Qualification of personnel

Only appropriately trained persons who are familiar with and understand the contents of this manual and all other pertinent product documenta­tion are authorized to work on and with this product. In addition, these persons must have received safety training to recognize and avoid haz­ards involved. These persons must have sufficient technical training, knowledge and experience and be able to foresee and detect potential hazards that may be caused by using the product, by changing the set­tings and by the mechanical, electrical and electronic equipment of the entire system in which the product is used.
All persons working on and with the product must be fully familiar with all applicable standards, directives, and accident prevention regulations when performing such work.

2.2 Intended use

This product is a motor with an integrated drive and intended for indus­trial use according to this manual.
The product may only be used in compliance with all applicable safety regulations and directives, the specified requirements and the technical data.
Prior to using the product, you must perform a risk assessment in view of the planned application. Based on the results, the appropriate safety measures must be implemented.
Since the product is used as a component in an entire system, you must ensure the safety of persons by means of the design of this entire sys­tem (e.g. machine design).
Operate the product only with the specified cables and accessories. Use only genuine accessories and spare parts.
The product must NEVER be operated in explosive atmospheres (haz­ardous locations, Ex areas).
Any use other than the use explicitly permitted is prohibited and can re­sult in hazards.
Electrical equipment should be installed, operated, serviced, and main­tained only by qualified personnel.
0198441113562, V2.00, 09.2008
Lexium Integrated Drive 21
2 Before you begin - safety information ILA1B, ILA1F, ILA1R

2.3 Hazard categories

Safety instructions to the user are highlighted by safety alert symbols in the manual. In addition, labels with symbols and/or instructions are at­tached to the product that alert you to potential hazards.
Depending on the seriousness of the hazard, the safety instructions are divided into 4 hazard categories.
@ DANGER
DANGER indicates an imminently hazardous situation, which, if not avoided, will result in death or serious injury.
@ WARNING
WARNING indicates a potentially hazardous situation, which, if not avoided, can result in death, serious injury, or equipment damage.
@ CAUTION
CAUTION indicates a potentially hazardous situation, which, if not avoided, can result in injury or equipment damage.
CAUTION
CAUTION used without the safety alert symbol, is used to address practices not related to personal injury (e.g. can result in equipment damage).
22 Lexium Integrated Drive
0198441113562, V2.00, 09.2008
ILA1B, ILA1F, ILA1R 2 Before you begin - safety information

2.4 Basic information

@ DANGER
UNINTENDED CONSEQUENCES OF EQUIPMENT OPERATION
When the system is started, the drives are usually out of the opera­tor's view and cannot be visually monitored.
Only start the system if there are no persons in the hazardous area.
Failure to follow these instructions will result in death or serious injury.
@ WARNING
UNEXPECTED MOVEMENT
Drives may perform unexpected movements because of incorrect wir­ing, incorrect settings, incorrect data or other errors.
Interference (EMC) may cause unpredictable responses in the sys­tem.
Carefully install the wiring in accordance with the EMC require­ments.
Switch off the voltage at the inputs STO_A (PWRR_B switching on and configuring the drive system.
Do NOT operate the drive system with unknown settings or data.
Perform a comprehensive commissioning test.
Failure to follow these instructions can result in death or serious injury.
) to avoid an unexpected restart of the motor before
(PWRR_A) and STO_B
0198441113562, V2.00, 09.2008
Lexium Integrated Drive 23
2 Before you begin - safety information ILA1B, ILA1F, ILA1R
@ WARNING
LOSS OF CONTROL
The designer of any control scheme must consider the potential failure modes of control paths and, for certain critical functions, provide a means to achieve a safe state during and after a path failure. Examples of critical control functions are EMERGENCY STOP, overtravel stop, power outage and restart.
Separate or redundant control paths must be provided for critical functions.
System control paths may include communication links. Consid­eration must be given to the implication of unanticipated transmis­sion delays or failures of the link.
Observe the accident prevention regulations and local safety guidelines.
Each implementation of the product must be individually and thor­oughly tested for proper operation before being placed into serv­ice.
Failure to follow these instructions can result in death or serious injury.
1) For USA: Additional information, refer to NEMA ICS 1.1 (latest edition), Safety Guidelines for the Application, Installation, and Maintenance of Solid State Control and to NEMA ICS 7.1 (latest edition), Safety Standards for Construction and Guide for Selection, Installation for Construction and Operation of Adjustable­Speed Drive Systems.
1)

2.5 Functional safety

@ CAUTION
UNEXPECTED BEHAVIOR AND DESTRUCTION OF SYSTEM COMPO­NENTS
When you work on the wiring and when you unplug or plug in connec­tors, this may cause unexpected behavior and destruction of system components.
Switch the power supply off before working on the wiring.
Failure to follow these instructions can result in injury or equip­ment damage.
Using the safety functions integrated in this product requires careful planning. For more information see chapter5.3 "Safety function STO ("Safe Torque Off")" on page 40.
24 Lexium Integrated Drive
0198441113562, V2.00, 09.2008
ILA1B, ILA1F, ILA1R 2 Before you begin - safety information

2.6 Standards and terminology

Technical terms, terminology and the corresponding descriptions in this manual are intended to use the terms or definitions of the pertinent standards.
In the area of drive systems, this includes, but is not limited to, terms such as "safety function", "safe state", "fault", "fault reset", "failure", "er­ror", "error message", "warning", "warning message", "alarm", etc.
Among others, these standards include:
IEC 61800 series: "Adjustable speed electrical power drive sys­tems"
IEC 61800-7 series: "Adjustable speed electrical power drive sys­tems - Part 7-1: Generic interface and use of profiles for power drive systems - Interface definition"
IEC 61158 series: "Industrial communication networks - Fieldbus specifications"
IEC 61784 series: "Industrial communication networks - Profiles"
IEC 61508 series: "Functional safety of electrical/electronic/pro­grammable electronic safety-related systems"
Also see the glossary at the end of this manual.
0198441113562, V2.00, 09.2008
Lexium Integrated Drive 25
2 Before you begin - safety information ILA1B, ILA1F, ILA1R
26 Lexium Integrated Drive
0198441113562, V2.00, 09.2008

ILA1B, ILA1F, ILA1R 3 Technical Data

3 Technical Data
This chapter contains information on the ambient conditions and on the mechanical and electrical properties of the device family and the acces­sories.

3.1 Certifications

Product certifications:
Certified by Assigned number Validity
TÜV Nord SAS-1728/08 2013-01-09 UL File E 153659
Certified safety function This product has the following certified safety function:
Safety function STO "Safe Torque Off" (IEC 61800-5-2)

3.2 Ambient conditions

Ambient temperature during
operation
Ambient conditions transportation
and storage
Temperature
The maximum permissible ambient temperature during operation de­pends on the distance between the devices and the required power. Ob­serve the pertinent instructions in the chapter Installation.
Operating temperature Operating temperature with cur-
rent reduction of 2% per Kelvin
1) Limit values with flanged motor (steel plate 300x300x10 mm)
2) If the product is to be used in compliance with UL 508C, note the information pro-
vided in chapter 3.5 "Conditions for UL 508C".
1) 2)
[°C] 0 ... 50 [°C] 50 ... 65
1)
The environment during transport and storage must be dry and free from dust. The maximum vibration and shock load must be within the speci­fied limits.
Temperature [°C] -25 ... +70
Max. temperature of power
1)
stage Max. temperature of motor
1) Can be read via parameter
2) Measured on the surface
2)
[°C] 105
[°C] 110
Relative humidity The following relative humidity is permissible during operation:
Relative humidity (non-condens­ing)
0198441113562, V2.00, 09.2008
[%] 15 ... 85
Lexium Integrated Drive 27
3 Technical Data ILA1B, ILA1F, ILA1R
Installation altitude The installation altitude is defined as height above sea level.
Installation altitude [m] ≤1000
Vibration and shock
EMC
Vibartion, sinusoidal As per IEC/EN 60068-2-6
Shock, semi-sinusoidal As per IEC/EN 60068-2-27:
Emission IEC/EN 61800-3: Class C2
Noise immunity IEC/EN 61800-3: Second environment
0.15 mm (from 10 Hz ... 60 Hz) 20 m/s2 (from 10 Hz ... 500 Hz)
2
150 m/s
EN 61000-6-4 EN 55022: Class A
(11 ms)
28 Lexium Integrated Drive
0198441113562, V2.00, 09.2008
ILA1B, ILA1F, ILA1R 3 Technical Data

3.3 Mechanical data

3.3.1 Degree of protection

IP degree of protection The product has the following IP degree of protection as per EN 60529.
1 2
Figure 3.1 IP degree of protection
Item Degree of
protection
1 Shaft bushing
Shaft bushing with GBX gear (accessory)
2 Housing, except shaft bushing IP54
IP41 IP54
The total degree of protection is determined by the component with the lowest degree of protection.
Overview of IP degrees of
protection
First digit Second digit Protection against intrusion of
objects
0 No protection 0 No protection 1 External objects >50 mm 1 Vertically falling dripping water 2 External objects >12 mm 2 Dripping water falling at an angle
3 External objects >2.5 mm 3 Spraying water 4 External objects >1 mm 4 Splashing water 5 Dust-protected 5 Water jets 6 Dust-tight 6 Heavy sea
Protection against intrusion of water
(75 ° ... 90 °)
7Immersion 8Submersion
Degree of protection if STO is used You must ensure that conductive substances cannot get into the product
(pollution degree 2). If you use the safety function and conductive sub­stances get into the product, the safety function may become inopera­tive.
0198441113562, V2.00, 09.2008
Lexium Integrated Drive 29
3 Technical Data ILA1B, ILA1F, ILA1R

3.3.2 Mounting position

Mounting position The following mounting positions are defined and approved as per EN
60034-7:
IM B5 drive shaft horizontal
IM V1 drive shaft vertical, shaft end down
IM V3 drive shaft vertical, shaft end up

3.3.3 Dimensions

2 3
17
5.5
M4
1 1
92.2
57.2
Ø 5.2
47.14
57.2
47.14
Figure 3.2 Dimensions
(1) Insert with cable entry (accessory) (2) Insert kit (accessory) (3) Industrial connector (option)
Total length L
ILA••571... ••1A0 ••2A0 ••1F0
L [mm] 145.3 179.3 190.8
73
9.5
20
1.6
Ø9 j6
Ø 50 h8
5.8
L
ILA••572... ••1A0 ••2A0 ••2F0
L [mm] 163.8 197.8 209.3
30 Lexium Integrated Drive
0198441113562, V2.00, 09.2008
Loading...
+ 174 hidden pages