PIR Motion Sensor
Mechanism
41EPIRM-TN
Installation
Instructions
NOTICE
RISK OF EQUIPMENT DAMAGE OR MALFUNCTION
(WIRING CONNECTIONS)
To avoid damaging the equipment and possibly voiding the
warranty:
• Test operation during installation and correct any wiring
errors immediately.
• Keep cable insulation away from the sides of the
enclosure to avoid possible damage or long term
degradation of the cable insulation.
Failure to follow these instructions can result in
equipment damage or malfunction.
Installation example: hallway
ZONE
MASK
SEGMENTS
D
LOUNGE
A
HALL
B
PET
DOOR
ZONE
MASK
SEGMENTS
C
PET
DOOR
Cabling and connections
Single PIR mechanism
N
L
PE
LOAD
NA
PE
A Active
N Neutral
L Load
PE Protective Earth
A
L
N
PIR MECHANISM
N
A
L
DANGER
HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR
ARC FLASH
• It is illegal for persons other than an appropriately
licensed electrical contractors or other persons authorised
by legislation to work on the xed wiring of any electrical
installation.
• To comply with all safety standards, the product must be
used only for the purpose described in this instruction and
must be installed in accordance with the wiring rules and
regulation in the location where it is installed.
• There are no user serviceable parts inside the product.
Failure to follow these instructions will result in death
or serious injury.
DANGER
RISK OF ELECTRIC SHOCK
• Hazardous voltage and electrical current may be present
at the wire leads of this product even when the device is
switched o.
• Lock out and tag the input circuit before accessing the
wiring connections.
• A circuit breaker (250 V a.c. 10 A) Type C must be
installed according to AS/NZS 60898.
• Use a terminal block to connect the PIR Mechanism to
the electrical circuit.
• After wiring, wrap the terminal block with insulating tape.
Failure to follow these instructions will result in death
or serious injury.
Detection pattern and range
100° Horizontal
Sensor locations
82° Vertical
Max. 5 m @ 20–25 °C
A 1× sensor to cover hallway front entrance.
B 1× sensor to cover hallway back entrance.
C Zone mask used to prevent detection near the pet door.
D Sensor covering lounge area. Zone mask used to prevent
detection in the hallway zone. (See Zone masking.)
Orientation for multi-gang installation
Fitting the PIR mechanism to the grid
A
B
C
2× PIR mechanisms (e.g. hallway application)
NA
L
N
PE
LOAD
A
PIR MECHANISM PIR MECHANISM
N
A
L
PE
A
A Active
N Neutral
L Load
PE Protective Earth
NN
A
L
N
Securing the PIR mechanism fly leads
Note: Ensure that the PIR mechanism y leads are tied back
or otherwise secured in accordance with the wiring rules and
regulations that apply in the location where the mechanism is
installed.
Mounting the grid
Wall box depth:
min. 41 mm
CAUTION
EQUIPMENT DAMAGE HAZARD
• Install the device according to instructions in this
document.
• Pay attention to the specications and wiring diagrams
related to the installation.
• Do not use this product for any other purpose than
specied in this instruction.
Failure to follow these instructions can result in minor
injuries, or equipment damage.
1 Open the locking bar A.
2 Push the head of the PIR mechanism into the grid aperture
until the head clicks into place B.
3 Close the locking bar C.
Adjusting the timer and lux settings
min. 2 lx
Timer
Lux
(Approx.
10 mins)
max.
15 mins
max.
2000 lx
min. 10 secs
Zone masking
A
B
Masked
zone
50°
50°
1 Remove zone mask segments to allow sensor to detect
movement A.
2 Remaining segments prevent detection of movement B.
Fitting the carrier or zone mask to the skin
Installing the skin Removing the skin
Manual override options
Depending on the wiring and the type of switch used, the
following manual override options are possible:
Option 1: Manual override activated by the sensor using a
rocker switch.
Option 2: Manual override bypassing the sensor using a
rocker switch.
Option 3: Manual override with 3-position switch.
Choose a manual override option
to suit the desired operation.
Desired operation 1 2 3
Switch load On when movement detected. Yes Yes Yes
Switch load O when no movement detected
and sensor timer has expired.
Manually switch load O indenitely until
manual switch back to sensor operation.
Manually switch load On indenitely until
manual switch back to sensor operation.
Manually switch sensor O indenitely until
manual switch back to sensor operation.
Manually switch load O on exit, then sensor
resumes normal operation automatically.
Manually switch load On when entering room
(e.g. if sensor hasn’t detected movement) then
sensor resumes normal operation automatically.
Manual override
option
Yes Yes Yes
Yes No Yes
No Yes Yes
Yes No Yes
Yes No Yes
Yes No Yes
Manual override option 1
Add a 1/2 way switch.
Sensor-activated override
• Toggle the switch to position B and back to A within 1.5 seconds.
• Sensor toggles the load state On or O and maintains that state for the
duration of the sensor timer setting.
• Sensor resumes normal operation once timer expires.
Note: If power to sensor is interrupted for 1.5 seconds, the load is
switched on for about 1 minute, then sensor resumes normal operation.
Manual OFF
• Operate switch to position B (turns sensor and load O).
• Operate switch to position A to resume sensor operation.
Cabling and connections for option 1
A Active
N Neutral
L Load
PE Protective Earth
Optional 2nd sensor + switch
(e.g. hallway application)
PIR MECHANISM
N
N
A
A
L
2
C
1
SWITCH (1/2 WAY)
N
L
PE
LOAD
N
LL
A
A
L
N
A
PIR MECHANISM
N
A
L
2
C
1
SWITCH (1/2 WAY)
A
N
PE
A
A
Manual override option 2
Add a 1/2 way switch.
Labelled dolly recommended
(“Auto/Manual” shown).
Auto
Manual
Manual ON
• Operate switch to position B to override sensor and keep load On.
• Operate switch to position A for normal sensor operation.
Cabling and connections for option 2
A Active
N Neutral
L Load
PE Protective Earth
Optional 2nd sensor + switch
(e.g. hallway application)
PIR MECHANISM
N
N
A
A
L
L
2
C
1
SWITCH (1/2 WAY)
N
L
PE
LOAD
N
L
A
A
A
L
N
A
L
SWITCH (1/2 WAY)
PIR MECHANISM
N
A
L
Manual override option 3
Add a 3-position switch.
A
Labelled dolly recommended
(“Sensor/O/On” shown).
B
Manual OFF
• Operate switch to position B (turns sensor and load O).
• Operate switch to position A to resume sensor operation.
Manual ON
• Operate switch to position c to override sensor and keep load On.
• Operate switch to position A for normal sensor operation.
Cabling and connections for option 3
A Active
N Neutral
L Load
PE Protective Earth
Optional 2nd sensor + switch
(e.g. hallway application)
PIR MECHANISM
N
N
A
A
L
L
SWITCH (3-POS)
1
C
2
N
L
A
Sensor
Off
On
A
N
PE
PIR MECHANISM
A
N
N
A
L
L
A
1
C
2
SWITCH (3-POS)
Technical specifications
Operating voltage 220–240 V a.c., 50 Hz
A
Auto
Manual
N
PE
A
2
A
C
1
L
Sensor
Off
On
L
PE
LOAD
L
L
A
Load ratings Incandescent lamps: 750 W
B
Fluorescent lamps: 100 W
LED lamps: 150 W
(max. 4 lamps)
Motor: M.3
AC halogen lamps: 400 W
LV halogen lamps: 400 VA
Timer setting range min. 10 s, max. 15 mins
A
Lux setting range min. 2 lx, max. 2000 lx
Detection technology Passive Infrared (PIR)
Angle of coverage 100° horizontal, 82° vertical
Detection range max. 5 m (at 20–25 °C)
Environmental rating IP20 (for indoor use only)
Operating temperature –10 °C to 50 °C
Compliance AS/NZS 60669-2-1
Specications typical at 25 °C.
49 mm
48.5 mm
Customer care
A
B
Warranty information
C
We warrant this product for 2 years. For details, please visit http://www.
schneider-electric.com.au/en/about-us/legal/terms-and-conditions.jsp.
Our goods also come with guarantees that cannot be excluded under the
Australian Consumer Law. You are entitled to a replacement or refund for
a major failure and compensation for any other reasonably foreseeable
loss or damage. You are also entitled to have the goods repaired or
replaced if the goods fail to be of acceptable quality and the failure does
not amount to a major failure.
Schneider Electric (Australia) Pty Ltd
Customer Care Australia: 1300 369 233
N
Email: customercare.au@schneider-electric.com
www.schneider-electric.com.au
Schneider Electric reserves the right to change specications, modify
designs and discontinue items without incurring obligation and whilst
every eort is made to ensure that descriptions, specications and other
information in this catalogue are correct, no warranty is given in respect
thereof and the company shall not be liable for any error therein.
© Schneider Electric 2017