Sanyo HIT POWER 220A, HIT POWER 210A, HIT POWER 215A, HIT POWER 205A Manual

0 (0)

General Installation Manual

© Jul 2010, Sanyo Electric Co., Ltd. All Rights Reserved. 7/13/10

General Installation Manual for SANYO

 

installation,

including,

without

 

 

subject the module to mechanical

HIT® Photovoltaic Modules. Please read

 

limitation, the risk of electric shock.

 

 

or electrical hazards.

 

 

 

 

 

this manual carefully before installing or

PV

modules

 

generate

DC(direct

Sparks may occur; do not install

using

SANYO

modules.

 

This

manual

 

current)

electrical

 

energy

when

 

 

modules where flammable gases

applies to the following HIT Power

 

exposed to sunlight or other light

 

 

or vapors are present.

 

 

 

products:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

sources. Even a single module

 

Never

rest

or

leave

a

module

HIT Power 220A (HIT-N220A01)

 

 

produces

enough

voltage

and

 

 

unsupported or unsecured.

 

 

HIT Power 215A (HIT-N215A01)

 

 

current, to cause shocks and burns

Do not drop modules.

 

 

 

 

 

HIT Power 210A (HIT-N210A01)

 

 

if

safety

precautions

are

not

Do

not use or install broken

HIT Power 205A (HIT-N205A01)

 

 

followed.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

modules.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The shock hazard increases as

Do

not artificially concentrate

INTRODUCTION

 

 

 

 

 

 

 

 

 

 

 

 

modules are connected in parallel,

 

 

sunlight on a module.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

producing

higher

 

current,

and

as

 

Do

not

touch

the

junction

box

Thank

you

for

 

choosing

SANYO

HIT

 

modules

are

connected

in

series,

 

 

 

 

 

terminals.

 

 

 

 

 

 

 

 

 

photovoltaic

(PV)

modules.

With proper

 

producing higher voltages.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Do

not change the wiring of

operation

and

 

maintenance,

SANYO

HIT

To avoid the hazard of electric

 

 

 

bypass diodes.

 

 

 

 

 

 

 

PV modules will provide you with clean,

 

sparks, shock, fire, burns, damage

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

renewable solar electricity for many years.

 

and injury:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

This manual contains important installation,

Cover the entire front surface of

 

CAUTIONS

 

 

 

 

 

 

 

 

 

maintenance and safety information. The

 

the PV modules with a dense,

Use

a

module

for

its

intended

word “module” as used in this manual refers

 

opaque

material

such

as

a

 

purpose only.

 

 

 

 

 

 

 

 

to one or more PV modules.

Retain this

 

cardboard box, during installation

Do not treat the back sheet, frame,

manual for future reference.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

and handling of the modules.

 

 

or front surface with paint or

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Disclaimer of Liability

 

 

 

 

 

 

 

 

Work only in dry conditions, with

 

adhesives,

to

avoid

reducing

its’

 

 

 

 

 

 

 

 

 

dry modules and dry tools.

 

 

 

functionality, damage, and causing

SANYO does not assume responsibility and

 

 

 

 

Do not stand or step on a modules.

 

inoperable

conditions,

 

and

other

expressly

disclaims

 

liability

for

loss,

 

 

 

Do

not

puncture,

cut,

scratch

 

unknown troubles.

 

 

 

 

 

 

damage, or

expense

arising

out

of,

or

in

 

 

 

 

 

 

 

 

ordamage the

back

sheet of a

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

any

way

 

connected

with

installation,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

module. Back sheet damage will

GENERAL SAFETY

 

 

 

 

 

 

 

 

operation,

use,

or maintenance

 

by using

 

 

 

 

 

 

 

 

 

 

 

void a module’s Limited Warranty

Follow all permissions, installation and

this manual.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

and

may cause

fire. Never

use

inspection requirements.

 

 

 

 

 

 

SANYO assumes no responsibility for any

 

modules

with

a

damaged back

Before installing modules, contact the

infringement

of

patents

or

 

other

rights

of

 

 

 

sheet.

 

 

 

 

 

 

 

 

 

 

 

 

appropriate

 

 

authorities

 

having

third parties, which may result from use of

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Do

not

 

allow

 

children

and

 

jurisdiction

to

determine

 

permissions,

modules.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

unauthorized

persons

near

the

 

installation

 

 

and

 

 

inspection

No license

is

 

granted

by

implication

or

 

 

 

 

 

 

 

 

installation

or

storage

site

of

 

requirements,

 

which

 

 

should

be

under

any

patent

or

patent

rights.

The

 

 

 

 

 

 

modules.

 

 

 

 

 

 

 

 

 

 

followed.

 

 

 

 

 

 

 

 

 

 

 

information in this manual is believed to be

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Completely ground all modules.

Electrically

ground

modules

for

all

reliable,

but

 

does

not

 

constitute

 

an

 

 

 

Do

not

disassemble

 

a module,

 

systems

of

any

voltage.

 

If

not

expressed and/or implied warranty.

 

 

 

 

 

 

 

 

attempt

any

repair,

 

open

the

 

otherwise specified, it is recommended

SANYO reserves the right to make changes

 

 

 

 

 

 

that requirements of the latest National

 

junction

box

cover,

nor

remove

 

to the product, specifications, data sheets

 

 

 

 

Electrical

Code

(USA)

or

Canadian

 

any

parts

installed

 

by

Sanyo.

 

and this manual without prior notice.

 

 

 

 

 

 

 

 

There

are

no

user

serviceable

 

Electric

Code

(Canada)

or

other

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

national

or

international

electrical

General Information

 

 

 

 

 

 

 

 

 

 

parts

within

 

the

 

module

or

 

 

 

 

 

 

 

 

 

 

 

 

 

 

standards be followed. Refer to “Earth

 

 

 

 

 

 

 

 

 

 

junction box.

 

 

 

 

 

 

 

 

 

The installation of solar modules requires a

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ground

Wiring” section

for

more

Unauthorized persons - except the

 

great

degree

of

skill

and

should

only

be

 

 

information.

 

 

 

 

 

 

 

 

 

 

 

qualified

licensed

professional -

 

 

 

 

 

 

 

 

 

 

 

performed

 

 

by

 

 

qualified

 

 

licensed

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Be sure

that

the building

or

structure

 

 

 

 

 

 

 

should not perform any electrical

professionals,

including, without

limitation,

 

 

work, including wiring.

 

 

 

 

(roof, façade, etc.) where the modules

licensed contractors and electricians.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

are

being

 

installed

has

 

enough

 

 

Wear

suitable

clothing,

guards,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

strength

to

support the

 

load

of

the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

eye

protection

 

and

 

gloves

to

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

modules.

 

 

 

 

 

 

 

 

 

 

 

 

WARNING

 

 

 

 

 

 

 

 

 

 

 

 

prevent

you

from

direct

contact

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

For modules mounted on roofs, special

All instructions should be read and

 

with 30 VDC or greater.

 

 

 

 

 

 

 

 

structures may

be

required to

help

understood

 

before

 

attempting

to

Wear

non-slip

gloves

and carry

 

 

 

 

provide proper installation support.

 

install, wire, operate, and maintain a

 

modules by the frame using both

 

 

 

 

Both,

roof

construction

and

module

photovoltaic

 

module. Contact

with

 

hands. Do not attempt to carry a

electrically

active

parts

 

of

the

 

module by yourself.

 

 

 

 

 

 

installation

design

have

an

effect on

 

 

 

 

 

 

 

 

the

fire

resistance

of

 

a

building.

module such as terminals can result

Do not carry a module by its wires

 

 

 

Improper installation may contribute to

in burns, sparks,

and lethal shock

 

or junction box.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

fire hazards.

Additional devices such

whether the module is connected or

Do

not

drop

anything

on

the

 

 

as ground fault, fuses, and disconnects

disconnected.

 

 

 

 

 

 

 

 

 

 

surface of a module.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

may be required.

 

 

 

 

 

 

 

The installer assumes the risk of all

Ensure

all

system

components

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

injury

that

 

might

 

occur

during

 

are compatible, and they do not

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

Sanyo HIT POWER 220A, HIT POWER 210A, HIT POWER 215A, HIT POWER 205A Manual

General Installation Manual

© Jul 2010, Sanyo Electric Co., Ltd. All Rights Reserved. 7/13/10

Do not use modules of different

 

Size: not less than 1.5” (38 mm)

measured at Standard Test Conditions

 

specifications in the same system.

 

width

 

 

 

 

 

(STC). STC conditions are; Irradiance

Follow all safety precautions of other

 

Thickness: not less than 0.12”(3 mm)

of 1000W/m, 25oC cell temperature,

 

system components which are used.

 

Material: aluminum alloy

 

 

and solar spectral irradiance per IEC

 

 

 

bolt torque range: 16N.m to 20N.m.

60904-3.

Note:

At the

time

of

UL Listing Information

Operating Conditions

 

 

 

shipment, Sanyo guarantees the output

To satisfy UL requirements, when installing

SANYO requires that modules be operated

level of its modules to be -0/+10%

the modules, be sure to:

within the following Operating Conditions:

against

 

Rated

 

Power

 

in

1)

Use only stranded or solid copper

1)

Terrestrial applications only—no outer

SPECIFICATIONS

based

on

Sanyo’s

 

single–conductor type PV wire or USE-

 

space or Special Conditions (see

factory inspection at STC conditions.

 

2 cable, 12AWG or larger conductors,

 

below).

 

 

 

 

2) Under real conditions, a

photovoltaic

 

rated 600V, 90 , sunlight resistant, for

2)

The ambient temperature must be

module

may

experience

 

conditions

 

modules and interconnect wiring that is

 

within

–20°C

(-4°F) to

46°C

(115°F).

that

produce more

current

 

 

and/or

 

 

The temperature limits are defined as

voltage than

reported at

 

 

Standard

 

exposed to weather.

 

 

 

 

 

the Monthly Average High or

Low of

Test Conditions. Therefore,

Isc

value

2)

Observe the requirements described in

 

 

the installation site.

 

 

 

of

modules should be multiplied by a

 

sections labeled INSTALLATION and

 

 

 

 

 

3)

The

wind

pressure

load

of

the

factor of 1.25 to determine

ampacity.

 

SPECIFICATIONS.

 

installation site should be less than

An additional factor of 1.25 may be

 

 

 

INSTALLATION

 

2,880N/m2 (60PSF).

 

 

 

required

for

sizing

conductors,

fuses,

4)

Some environmental conditions could

disconnects,

etc.

Please

refer

to

General

 

apply. Please refer to Sanyo’s warranty

section

690.8

of

the

 

National

Please read this guide completely before

 

 

 

exclusions.

 

 

 

 

Electrical Code (NEC) for guidelines.

installing or using your Sanyo PV modules.

 

 

 

 

 

 

 

 

 

 

 

 

The Voc must be factored according

This

section contains important electrical

 

 

 

 

 

 

 

 

 

 

 

 

 

 

to

the

lowest recorded

 

ambient

and mechanical specifications.

 

 

 

 

 

 

 

 

SPECIFICATIONS

 

 

 

temperature

recorded

 

for

 

the

Modules should be firmly fixed in place

 

 

 

 

 

 

 

 

location where the modules will be

 

in a manner suitable to withstand all

Notes on Specifications

 

 

 

 

 

 

 

installed. Please

refer

to

section

 

expected loads, including wind and

1)

Rated

electrical characteristics

are

 

690.7

of

the

NEC

for

more

 

snow loads.

 

within

–5%

to +10%

of the

values

 

 

information

regarding

 

 

voltage

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Metals

 

used

in locations that are

 

 

 

 

 

exposed

to

moisture

 

shall

not

be

Installation (reference)

 

 

 

employed alone or in combinations that

 

 

 

 

 

 

 

 

could result in deterioration or

 

 

 

 

 

corrosion.

 

 

 

 

 

 

 

 

 

38mm

 

 

Install

modules where

they

are

not

 

 

 

 

 

 

Solar Module

 

shaded by obstacles like buildings and

38mm

 

 

 

 

 

trees.

Pay

special

attention

to avoid

 

 

 

 

Metal clamp B

 

 

 

partially

shading

the

 

modules

by

 

 

 

 

 

 

(2 places)

 

 

 

objects during the daytime.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

If

needed,

 

contact

an

Authorized

Metal clamp A

 

 

 

 

Representative

with

 

questions

(2 places)

 

 

 

 

regarding mounting profiles for Sanyo

 

 

 

 

 

PV modules.

 

 

 

 

 

 

 

 

 

 

 

Notes on Installation

 

 

 

 

 

 

 

Mounting

 

 

Clearance

between

the

roof

surface

 

 

 

 

Structure Rail

 

 

 

and module frame is required to allow

 

 

 

 

Metal clamp A

 

 

 

 

cooling air to circulate around the back

Metal clamp B

 

Solar Module

 

 

 

 

of the module. This also allows any

 

 

 

 

 

condensation or moisture to dissipate.

 

 

 

 

 

Install modules so that air can circulate

 

 

 

 

 

between the roof and the module.

 

 

 

 

 

Leave 1 inch of clearance between the

 

Mounting Structure Rail

 

 

 

roof and the module frame. If other

M8 Bolt

 

 

 

mounting means are employed this

 

Metal clamp B

 

M8 Bolt

 

may effect the temperature of the panel.

Metal clamp A

 

 

 

SANYO

recommends the installation

 

 

 

 

 

 

 

 

method and mounting profile shown in

 

Module

 

 

 

Figure 1.

 

 

 

 

 

 

 

 

M8 Nut

Mounting Structure

M8 Nut

A

module

should be attached on a

 

 

 

 

 

 

mount or support structure rail by metal

 

End of Module

Between Modules

 

clamps. The metal clamp must fulfill

 

 

 

 

 

 

 

the following specifications.

 

 

 

 

Figure 1. Installation

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2