Pilz PNOZ x5 Data Sheet

E-STOP relays, safety gate monitors
Up to PL e of EN ISO 13849-1
PNOZ X5
Gertebild
][Bildunterschrift_NOT_Sch.tuer_Licht
Approvals
PNOZ X5
SÜDDEUTSCHLAND
Unit features
Gertemerkmale
` Positive-guided relay outputs:
– 2 safety contacts (N/O), instanta-
neous
` Connection options for:
– E-STOP pushbutton – Safety gate limit switch – Reset button – Light barriers
` LED indicator for:
– Switch status channel 1/2 – Supply voltage
` See order reference for unit types
Unit description
Bestimmung/Gertebesc hreibung NOT-AUS , Schutzt, Lichtsc hr_PNOZ
The safety relay meets the require­ments of EN 60947-5-1, EN 60204-1 and VDE 0113-1 and may be used in applications with
` E-STOP pushbuttons ` Safety gates ` Light beam devices
Safety features
][Sicherheitseigenschaften Schaltgerät_allgemeiner Teil
The relay meets the following safety requirements:
` The circuit is redundant with built-in
self-monitoring.
` The safety function remains effec-
tive in the case of a component fail­ure.
` The correct opening and closing of
the safety function relays is tested automatically in each on-off cycle.
Sicherheitseigenschaften Zusatz - Sicherung DC_PNOZ
` The unit has an electronic fuse.
Zulassungen
Block diagram
Blockschaltbild
S11 S12A1 A2
~
Input
S22
Input
S33 S34
Reset/
Start
=
Power
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: pilz.gmbh@pilz.de
13 23
K1
K2
14 24
NSG-D-2-035-2010-08
E-STOP relays, safety gate monitors
Up to PL e of EN ISO 13849-1
PNOZ X5
Function description
][Funktionen_einkanalig_Erd_Start
` Single-channel operation: no re-
dundancy in the input circuit, earth faults in the reset circuit are detect­ed.
][Funktionen_zweikanalig_ohne_quer
` Dual-channel operation without de-
tection of shorts across contacts: redundant input circuit, detects
Timing diagram
POWER
Reset/Start
Input
Output safe
Key
` Power: Supply voltage ` Reset/Start: Reset circuit S33-S34 ` Input: Input circuits S11, S12, S22 ` Output safe: Safety contacts 13-14,
23-24
` c: Automatic reset
– earth faults in the reset and input
circuit,
– short circuits in the input circuit
and, with a monitored reset, in the reset circuit too.
][Funktionen_autoStart
` Automatic start: Unit is active once
the input circuit has been closed.
][Funktionen_manuStart
][Zeitdiagramm_auto_manu
1 2
t1 t2
t1 t2
` d: Manual reset ` a: Input circuit closes before reset
circuit
` b: Reset circuit closes before input
circuit
: Switch-on delay
` t
1
` Manual reset: Unit is active once
the input circuit is closed and then the reset circuit is closed.
][Funktionen_Kontaktvervielfachung
` Increase in the number of available
instantaneous safety contacts by connecting contact expansion modules or external contactors.
ab
t1
t1
t2
t3
` t
2
` t
3
t2
: Delay-on de-energisation : Recovery time
Wiring
][Verdrahtung_Si_unverz
Please note:
` Information given in the “Technical
details” must be followed.
` Outputs 13-14, 23-24 are safety
contacts.
` To prevent contact welding, a fuse
should be connected before the output contacts (see technical de­tails).
` Calculation of the max. cable runs
in the input circuit:
l
max
R
lmax
=
I
max
Rl / km
R
= max. overall cable resist-
lmax
ance (see technical details)
/km = cable resistance/km
R
l
` Use copper wire that can withstand
60/75 °C.
` Sufficient fuse protection must be
provided on all output contacts with capacitive and inductive loads.
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: pilz.gmbh@pilz.de
NSG-D-2-035-2010-08Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
-2
E-STOP relays, safety gate monitors
Up to PL e of EN ISO 13849-1
PNOZ X5
Preparing for operation
Betriebsbereitschaft her stellen
` Supply voltage
Supply voltage AC DC
A1
A2
L1
N
` Input circuit
Input circuit Single-channel Dual-channel E-STOP
without detection of shorts across con­tacts
Safety gate without detection of shorts across con­tacts
S11 S12 S22
S11 S12 S22
S1
S1
S11
S12 S22
A1
A2
S11
S12 S22
S1
L+
L-
S1
S2
Light barrier with detection of shorts across contacts via ESPE
` Reset circuit
Reset circuit E-STOP wiring (single-channel)
Safety gate (single-channel)
Automatic reset
Manual reset
S33
S34
S33
S34
S3
S12
S12 S22
S22
E-STOP wiring (dual-channel) Safety gate (dual-channel)
S33
S34
S33
S34
24 V DC
24 V DC
S3
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: pilz.gmbh@pilz.de
NSG-D-2-035-2010-08