Pilz PNOZ s11 Data Sheet

Contact expansion modules
Input
A1 A2
=
Power
=
K1
K2
13
23 33 51
24 34 52
14
43
44
*
Interface
base
unit
63
73 83
74 84
64
93
94
Up to PL e of EN ISO 13849-1
PNOZ s11
Gertebild
][Bildunterschrift Kontakterweiterungen
Approvals
PNOZ s11
Unit features
Gertemerkmale
Positive-guided relay outputs:
– 8 safety contacts (N/O), instanta-
neous
– 1 auxiliary contact (N/C), instan-
taneous
Safe separation of safety contacts
from all other circuits
LED indicator for:
– Input status, channel 1 – Input status, channel 2 – Switch status, safety contacts – Error
Plug-in connection terminals (either
spring-loaded terminal or screw terminal)
Unit description
Bestimmung/Gertebesch reibung Kontakter weiterungen Schalt _PNOZ
The unit meets the requirements of EN 60947-5-1, EN 60204-1 and VDE 0113-1. The contact expansion module is used to increase the number of instantaneous safety contacts avail­able on a base unit. Base units are all safety relays with feedback loop mon­itoring. The category that can be achieved in accordance with EN 954-1 and EN ISO 13849-1 depends on the cate-
gory of the base unit. The contact ex­pansion module may not exceed this.
Safety features
Sicherheitseigenschaften Kontakterweiterungen allg_PNOZ
The unit meets the following safety re­quirements:
The contact expansion module ex-
pands an existing circuit. As the output relays are monitored via the base unit's feedback loop, the safe­ty functions on the existing circuit are transferred to the contact ex­pansion module.
The safety function remains effec-
tive in the case of a component fail­ure.
Earth fault in the feedback loop:
Detected, depending on the base unit that is used.
Earth fault in the input circuit:
The output relays de-energise and the safety contacts open.
Zulassungen
Block diagram
Blockschaltbild
*Safe separation in accordance with EN 60947-1, 6 kV
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: pilz.gmbh@pilz.de
1001967-EN-04-2011-09
Contact expansion modules
POWER
Input
Feedback
Output safe
t1 t1t2 t2
R
lmax
Rl / km
I
max
=
Up to PL e of EN ISO 13849-1
PNOZ s11
Function description
][Funktionsbeschreibung_Erweiterungsgert
with PNOZsigma base unit:
Dual-channel operation via
PNOZsigma connector
Timing diagram
Key
Power: Supply voltage Input: Input circuits A1
Wiring
without PNOZsigma base unit:
Single-channel operation: one input
circuit affects the output relays
][Zeitdiagramm_PNOZs_Kontakterw_in_out_aux-rfk
Output safe: Safety contacts 13-14,
23-24, 33-34, 43-44, 63-64, 73-74, 83-84, 93-94
Feedback: Feedback loop 51-52
: Switch-on delay
t
1
: Delay-on de-energisation
t
2
][Verdrahtung_Si_unverz_1Hi_unverz
Please note:
Information given in the “Technical
details” must be followed.
Outputs 13-14, 23-24, 33-34, 43-
44, 63-64, 73-74, 83-84, 93-94 are safety contacts, output 51-52 is an auxiliary contact (e.g. for display).
To prevent contact welding, a fuse
should be connected before the output contacts (see technical de­tails).
Calculation of the max. cable runs
in the input circuit:
l
max
R
= max. overall cable resist-
lmax
ance (see technical details)
/km = cable resistance/km
R
l
Use copper wire that can withstand
60/75 °C.
Sufficient fuse protection must be
provided on all output contacts with capacitive and inductive loads.
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: pilz.gmbh@pilz.de
1001967-EN-04-2011-09Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
-2
Contact expansion modules
A1 A2
24 V DC
0 V
PNOZsigma expansion module
A1 A2
24 V DC
0 V
PNOZsigma expansion module
A1
A20 V
O1
L-
PNOZsigma expansion module
52
51
feedback loop
PNOZsigma expansion module
51
52
24 V DC
feedback loop
PNOZsigma expansion module
Interface
PNOZsigma
PNOZsigma base unit
PNOZsigma expansion module
Up to PL e of EN ISO 13849-1
PNOZ s11
Preparing for operation
Betriebsbereitschaft herstellen PNOZs
Supply voltage
Supply voltage AC DC
Input circuit
Input circuit Single-channel Dual-channel Base unit:
Safety relay PNOZ X
Base unit: Safety relay PNOZelog Driven via semiconductor outputs (24 VDC)
Feedback circuit
Feedback circuit Base unit: Safety relay
PNOZ X
The inputs that evaluate the feedback loop will depend on the base unit and applica­tion
Connection to PNOZsigma base unit
Base unit: Safety relay PNOZsigma
The feedback loop is connected and eval­uated via the connector
][Betriebsbereitschaft_herstellen_Info_Erweiterungsgert_DB
INFORMATION
If a base unit and a contact expander
Do not connect A1 to the contact ex-
pander module! module from the PNOZsigma range are connected via the connector, no additional wiring is necessary.
Base unit: Safety relay PNOZelog
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: pilz.gmbh@pilz.de
1001967-EN-04-2011-09