E-STOP relays, safety gate monitors
Up to PL c of EN ISO 13849-1
PNOZ s1
Gertebild
][Bildunterschrift
Safety relay for monitoring E-STOP
pushbuttons and safety gates.
Approvals
PNOZ s1
SÜDDEUTSCHLAND
Zulassungen
Unit features
Gertemerkmale
` Relay outputs:
– 2 safety contacts (N/O), instanta-
neous
` 1 semiconductor output
` Connection options for:
– E-STOP pushbutton
– Safety gate limit switch
– Reset button
` A connector can be used to con-
nect 1 PNOZsigma contact expander module
` LED indicator for:
– Supply voltage
– Input status, channel 1
– Input status, channel 2
– Switch status, safety contacts
– Reset circuit
– Error
` Plug-in connection terminals (either
spring-loaded terminal or screw
terminal)
Unit description
Bestimmung/Gertebeschreibung NOT-AUS, Schutz_PNOZ
The safety relay meets the requirements of EN 60947-5-1, EN 60204-1
and VDE 0113-1 and may be used in
applications with
` E-STOP pushbuttons
` Safety gates
Safety features
][Sicherheitseigenscha ften Schaltgerät_allgem einer Teil
The relay meets the following safety
requirements:
` The circuit is redundant with built-in
self-monitoring.
` The safety function remains effec-
tive in the case of a component failure.
` The correct opening and closing of
the safety function relays is tested
automatically in each on-off cycle.
Sicherheitseigenschaften Zusatz - Sicherung DC_PNOZ
` The unit has an electronic fuse.
Block diagram
Blockschaltbild
A1 A2
=
Power
=
Input
Reset/
Start
S34
Y32
K1
K2
13
14
23
24
unit
Interface
expansion
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: pilz.gmbh@pilz.de
NSG-D-2-392-2010-10
E-STOP relays, safety gate monitors
Up to PL c of EN ISO 13849-1
PNOZ s1
Function description
][Funktionen_einkanalig
` Single-channel operation: no re-
dundancy in the input circuit, earth
faults in the reset and input circuit
are detected.
][Funktionen_autoStart
Timing diagram
POWER
Reset/Start
Input
Output safe
Semi
Key
` Power: Supply voltage
` Reset/Start: Reset circuit S34
` Input: Input circuits A1-A2
` Output safe: Safety contacts 13-14,
23-24
` Semi: Semiconductor outputY32
` Automatic start: Unit is active once
the input circuit has been closed.
][Funktionen_manuStart
` Manual reset: Unit is active once
the input circuit is closed and then
the reset circuit is closed.
][Funktionen_Kontaktvervielfachung_PNOZsigma
` Increase in the number of available
instantaneous safety contacts by
][Zeitdiagramm_auto_manu_semi
1 2
t1 t2
t1 t2
` c: Automatic reset
` d: Manual reset
` a: Input circuit closes before reset
circuit
` b: Reset circuit closes before input
circuit
connecting contact expander modules or external contactors/relays;
A connector can be used to connect 1 PNOZsigma contact expander module.
ab
t1
t1
t2
3
t
` t
1
` t
2
` t
3
t2
: Switch-on delay
: Delay-on de-energisation
: Recovery time
Wiring
][Verdrahtung_Si_unverz
Please note:
` Information given in the “Technical
details” must be followed.
` Outputs 13-14, 23-24 are safety
contacts.
` To prevent contact welding, a fuse
should be connected before the
output contacts (see technical details).
` Calculation of the max. cable runs
in the input circuit:
l
max
R
lmax
=
I
max
Rl / km
R
= max. overall cable resist-
lmax
ance (see technical details)
/km = cable resistance/km
R
l
` Use copper wire that can withstand
60/75 °C.
` Sufficient fuse protection must be
provided on all output contacts with
capacitive and inductive loads.
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: pilz.gmbh@pilz.de
NSG-D-2-392-2010-10Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
-2
E-STOP relays, safety gate monitors
Up to PL c of EN ISO 13849-1
PNOZ s1
Preparing for operation
Betriebsbereitschaft her stellen
` Supply voltage
Supply voltage AC DC
` Input circuit
Input circuit Single-channel Dual-channel
E-STOP
without detection of shorts across contacts
Safety gate
without detection of shorts across contacts
A1
A1
S1
L+
S1
L+
A1
A2
S1
L+
L-
` Reset circuit
Reset circuit Reset circuit Feedback circuit
Automatic reset
A1
S34
Manual reset
A1
S34
S3
A1
S34
13 (23)
14 (24)
A1
S34
13 (23)
14 (24)
K5
K5
K6
K5
K6
K6
K5
K6
L1
N
S3
L1
N
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: pilz.gmbh@pilz.de
NSG-D-2-392-2010-10