3.5 - 139
3.5
Isolated Hermetic Surface Mount Package
1.5 Amp, -5V, -12V, -15V Negative Voltage Regulators
4 11 R1 Supersedes 1 05 R0
FEATURES
• Small Hermetic Surface Mount Package
• Chip Isolated From Package
• Output Voltages: -5V, -12V, -15V
• Output Voltages Set Internally To ±1%
• Built-In Thermal Overload Protection
• Short Circuit Current Limiting
• Product Is Available Hi-Rel Screened
DESCRIPTION
These three terminal negative regulators are supplied in a hermetically sealed surface mount package. All protective features are designed into the circuit including thermal shutdown, current limiting and safe-area control. With heat sinking, they can deliver over 1.5 amps of output current. These units feature internally trimmed output voltages to ±1% of nominal output voltage. Standard voltages are -5V, -12V, and
-15V. These units are ideally suited for Military applications where a hermetically sealed surface mount package is required.
ABSOLUTE MAXIMUM RATINGS
Input to Output Voltage Differential........................................-35V
Operating Junction Temperature Range........................- 55°C to + 150°C
Storage Temperature Range .................................- 55°C to + 150°C
Typical Power/Thermal Characteristics:
Rated Power @ 25°C
TC..........................................................17.5W
TA.............................................................3W
Thermal Resistance:
θ
JC
........................................................4.2°C/W
θ
JA
........................................................42°C/W
Lead Temperature at Case (5 sec).................................225°C
OM7644SMOM7642SM
OM7643SM
3.5 - 140
OM7642SM - OM7644SM
3.5
ELECTRICAL CHARACTERISTICS -5 Volt V
IN
= -10V, Io= 500mA, -55°C ≤ TA≤ 125°C (unless otherwise specified)
Parameter Symbol Test Conditions Min. Max. Unit
Output Voltage V
OUT
TA= 25°C -4.95 -5.05 V
V
IN
= -7.5V to -20V -4.85 -5.15 V
Line Regulation V
RLINE
VIN= -7.5V to -20V 12 mV
(Note 1)
25 mV
V
IN
= -8.0V to -12V 5 mV
12 mV
Load Regulation V
RLOAD
IO = 5mA to 1.5 Amp 20 mV
(Note 1)
25 mV
I
O
= 250mA to 750 mA 15 mV
30 mV
Standby Current Drain I
SCD
2.5 mA
3.0 mA
Standby Current Drain ∆I
SCD
VIN= -7.0V to -20V 0.4 mA
Change With Line (Line)
Standby Current Drain ∆I
SCD
IO= 5mA to 1000mA 0.4 mA
Change With Load (Load)
Dropout Voltage V
DO
V
OUT
= 100mV, I
O
=1.0A 2.5 V
Peak Output Current I
O (pk)
TA= 25°C 1.5 3.3 A
Short Circuit Current I
DS
VIN= -35V 1.2 A
(Note 2)
2.8 A
Ripple Rejection ∆V
IN
f =120 Hz, ∆VIN= -10V 63 dB
V
OUT
(Note 3) 60 dB
Output Noise Voltage N
O
TA= 25°C, f =10 Hz to 100KHz 40 µV/V
(Note 3) RMS
Long Term Stability ∆V
OUT
TA= 25°C, t = 1000 hrs. 75 mV
(Note 3) ∆t
ELECTRICAL CHARACTERISTICS -12 Volt V
IN
= -19V, Io= 500mA, -55°C ≤ TA≤ 125°C (unless otherwise specified)
Parameter Symbol Test Conditions Min. Max. Unit
Output Voltage V
OUT
TA= 25°C -11.88 -12.12 V
V
IN
= -14.5V to -27V -11.64 -12.36 V
Line Regulation V
RLINE
VIN= -14.5V to -27V 20 mV
(Note 1)
50 mV
V
IN
= -16V to -22V 10 mV
30 mV
Load Regulation V
RLOAD
IO = 5mA to 1.5 Amp 32 mV
(Note 1)
60 mV
I
O
= 250mA to 750 mA 16 mV
30 mV
Standby Current Drain I
SCD
3.5 mA
4.0 mA
Standby Current Drain ∆I
SCD
VIN= -14.5V to -27V 0.8 mA
Change With Line (Line)
Standby Current Drain ∆I
SCD
IO= 5mA to 1000mA 0.5 mA
Change With Load (Load)
Dropout Voltage V
DO
V
OUT
= 100mV, I
O
=1.0A 1.8 V
Peak Output Current I
O (pk)
TA= 25°C, IO= 5mA to 1A 1.5 3.3 A
Short Circuit Current I
DS
V
IN
= -35V 1.2 A
(Note 2)
2.8 A
Ripple Rejection ∆V
IN
f =120 Hz, ∆VIN= -10V 56 dB
V
OUT
(Note 3) 53 dB
Output Noise Voltage N
O
TA= 25°C, f =10 Hz to 100KHz 40 µV/V
(Note 3) RMS
Long Term Stability ∆V
OUT
TA= 25°C, t = 1000 hrs. 120 mV
(Note 3) ∆t
Notes:
1. Load and Line Regulation are specified at a constant junction temperature. Pulse testing with low duty cycle is used. Changes in output voltage due to heating effects must be taken into account separately.
2. Short Circuit protection is only assured up to V
IN
= -35V.
3. If not tested, shall be guaranteed to the specified limits. The • denotes the specifications which apply over the full operating temperature range.