Safety Precautions

arning •Violation of warnings may lead to serious injury or death.

Turn power off before contact

Install a circuit breaker.

Use with proper rated voltage.

of the product.

•Risk of fire and electric shock.

(less than ±10%)

 

 

•Risk of electric shock.

 

•Risk of fire and product dam-

 

 

age.

If there is a ground wire, perform grounding work.

•Risk of electric shock.

Do not install in areas that have risks of flooding.

•Risk of electric shock and fire.

Do not cover the device with clothes or paper. Do not place it near inflammables.

•Otherwise, it may cause malfunction of the device or fire.

If the lamp turns off by itself, do not disassemble the product. Contact your local LGE sales representative for repair.

•Risk of electric shock and product malfunctioning.

 

logy

Techno

standard

about

electric

s

facilitie

Electric work must be performed by a certified technician according to the installation manual.

•Inadequate power capacity and faulty electric work may lead to fire or electric shock.

Do not use the product if impurities are present in the product or if the product is submerged.

•Risk of accidents such as electric shock and product damage.

Do not disassemble or arbitrarily remodel the product. Do not use for underwater lighting pur- poses. (Underwater landscape, searchlight, fishing, events, etc.)

•Risk of fire and electric shocks.

Do not stare directly at the lamp when turned on.

•Strong light may cause visual impairment.

Do not randomly connect the power polarities.

•Risk of product damage and accidents.

Do not store in a humid area.

•Risk of product malfunctioning.

Must fix the product properly on the ceiling.

•Risk of product dropping and causing injury to the user.

Do not expose the product to water when cleaning it.

•Risk of fire and electric shock.

Do not use if the product has

Be careful not to apply exces-

been dropped or exposed to

sive force to the power cable.

shock.

•Otherwise, it may cause the de-

 

•Risk of product malfunctioning.

vice to drop or result in electric

 

shock.

caution • Violation of precautions may lead to light injury or product damage.

Keep some distance between the lamp and the object to be illuminated.

•If the illumination distance is too close or if the illumination is on a material's surface, this may cause discoloration or deformation of the object or cause fire.

•Do not wipe the surface with inflammables, such as alcohol, benzene, and acetone. •Do not use the device in places with corrosive gases.

•The color and the brightness of the lamp may differ even among the same model because the LED light source has "light dispersion".

Installation

Make sure to turn off the main power switch off the installation space before connection.

Connect so that the colors of the 3 power cables match.

(LIVE: BROWN, NEUTRAL: BLUE, P.E.: GREEN/YELLOW)

power

1(875$/ Interior wiring of the building

/,9( 3 (

Wire connectors Wi

Product’s power

1Drill and prepare the ceiling so that it can accommodate the product.

Refer to page 3 for product size.

3Tuck up a spring of the product and then hang it on the ceiling.

6Check to see if the product’s exterior surface is installed on the ceiling so that there

is no gap between them.

2Connect the 3 product cables to the interior wiring of the building. For wire connectors,

use standardized products.

The 4 Inch product is used for Singlephase two-wire system. (Without P.E.)

4Insert the power cable in such a way that the power cable does not get tangled between

the ceiling surface and the product.

7Turn the power switch on to verify that the product is working properly.

{c @ }

5Sufficiently lift the product so that the spring can be inserted on the other side.

Duringtheuseofconnectorsocket,ifthepowerlineis forcedin,itmaynotbelightedduetodefectcontact.

-Connector Socket-

When this luminaire is connected to branch circuit, installation engineer must use the connector that meets the glow-wire test of 650°C (in case of France, 850°C) or higher.

Dimming Terminal Connection

To dim the lamps, a compatible dimmer should be used.

The use of incompatible dimmers will result in damage to the products.

Before installing dimmers, verify the compatible dimmer list with your local LGE sales representative.

 

 

Pin No.

Output Name

 

 

1

GND

1

2

2

0~10V

 

 

 

 

 

Wire dimming function is included. (0-10V)

Please use wire with designated thickness. (24-20AWG)Be careful of the polarity for correct dimming control.

Maximum number of products to be connected to 1 dimming controller: 14 (Compatible dimmer: 5743 09(Legrand))