JENN-AIR JED4430GB, JED3430GS, JED4536KS, JED4536KB, JED4536GS Installation Instructions

...
0 (0)

30" (76.2 CM) AND 36" (91.4 CM) ELECTRIC DOWNDRAFT COOKTOP INSTALLATION INSTRUCTIONS

INSTRUCTIONS D’INSTALLATION DE LA TABLE DE CUISSON ÉLECTRIQUE AVEC ASPIRATION PAR LE BAS DE 30" (76,2 CM) ET 36" (91,4 CM)

Table of Contents/Table des matières

COOKTOP SAFETY........................................................................

2

INSTALLATION REQUIREMENTS.................................................

2

Tools and Parts.............................................................................

2

Location Requirements.................................................................

3

Venting Requirements...................................................................

4

Venting Methods...........................................................................

5

Electrical Requirements................................................................

7

INSTALLATION INSTRUCTIONS...................................................

8

Prepare Cooktop..........................................................................

8

Install Foam Strip..........................................................................

9

Install Cooktop..............................................................................

9

Make Electrical Connection..........................................................

9

Complete Installation..................................................................

10

SÉCURITÉ DE LA TABLE DE CUISSON.....................................

11

EXIGENCES D’INSTALLATION....................................................

11

Outils et pièces...........................................................................

11

Exigences d’emplacement.........................................................

12

Exigences concernant l’évacuation............................................

13

Méthodes d’évacuation..............................................................

14

Spécifications électriques...........................................................

16

INSTRUCTIONS D’INSTALLATION.............................................

17

Préparation de la table de cuisson.............................................

17

Installation de la bande de mousse............................................

18

Installation de la table de cuisson..............................................

18

Raccordement électrique...........................................................

18

Achever l’installation...................................................................

19

IMPORTANT:

Save for local electrical inspector’s use.

IMPORTANT :

À conserver pour consultation par l’inspecteur local des installations électriques.

W10848428A

COOKTOP SAFETY

Your safety and the safety of others are very important.

many important safety messages in this manual and on your appliance. Always read and obey all safety

safety alert symbol.

alerts you to potential hazards that can kill or hurt you and others.

messages will follow the safety alert symbol and either the word “DANGER” or “WARNING.”

mean:

DANGER WARNING

You can be killed or seriously injured if you don't immediately follow instructions.

You can be killed or seriously injured if you don't follow instructions.

All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can happen if the instructions are not followed.

INSTALLATION REQUIREMENTS

Tools and Parts

Gather the required tools and parts before starting installation. Read and follow the instructions provided with any tools listed here.

Tools needed

■■

Tape measure

■■

Marker or pencil

■■

Flat-blade screwdriver

■■

Pliers

■■

Phillips head screwdriver

■■

1/4" drill bit

■■

Drill

■■

Jigsaw

■■

Level

■■

Ratchet with 3/8" socket

■■

6" socket extension

■■

1/4" nut driver

Parts supplied

 

 

■■

Vent grille

■■

Downdraft motor

■■ Pre-filter

 

assembly

 

Clamping brackets (2)

■■

Plenum

■■

 

Bracket attachment

■■ Plenum screw pack

■■

 

screws (2)

 

 

 

Parts needed

■■ A UL Listed or CSA Approved strain relief for 7/8" (2.2 cm) knockout.

■■ A UL Listed or CSA Approved conduit connector for 1/2" (1.3 cm) trade-size metal-clad conduit

■■ UL Listed wire connectors ■■ Metal ducting

■■ Wall cap

6" (15.2 cm) Round Surface Wall Cap Damper Order Part Number A406

5" (12.7 cm) Round Surface Wall Cap Damper Order Part Number A405

31/4" x 10" (8.3 cm x 25.4 cm) Surface Wall Cap Damper Order Part Number A403

To order, see the “Assistance or Service” section of the Use and Care Guide.

■■ Vent clamps

Check local codes. Check existing electrical supply. See the “Electrical Requirements” section.

It is recommended that all electrical connections be made by a licensed, qualified electrical installer.

2

JENN-AIR JED4430GB, JED3430GS, JED4536KS, JED4536KB, JED4536GS Installation Instructions

Location Requirements

IMPORTANT: Observe all governing codes and ordinances. When installing cooktop, use minimum dimensions given.

■■ To eliminate the risk of burns or fire by reaching over the heated surface units, cabinet storage space located above the surface units should be avoided. If cabinet storage is to be provided, the risk can be reduced by installing a range hood that projects horizontally a minimum of 5" (12.7 cm) beyond the bottom of the cabinets.

■■ Use the countertop opening dimensions that are given with these Installation Instructions. Given dimensions are minimum clearances and provide 0" (0 cm) clearance.

■■ Grounded electrical supply is required. See the “Electrical Requirements” section.

■■ If cabinet has drawers, drawers will need to be removed and drawer fronts installed on front of cabinet.

IMPORTANT: An under-counter built-in oven cannot be installed under this product.

Product Dimensions

30" (76.2 cm) Cooktop – for standard and electric models

A

C

B

A.221/16" (56.0 cm) without stainless steel trim or 221/2" (57.2 cm) or 23" (58.5 cm) with stainless steel trim (depending on model)

B.Model/serial rating/clearance plate location

C.203/4" (52.7 cm) screw head to screw head

A

G

 

 

F

 

 

E

 

 

 

D

B

 

 

C

A. 307/8" (78.4 cm)

E. 2" (5.1 cm) recommended minimum

B. 123/16" (31.0 cm)

 

cabinet to motor clearance

C. 2813/64" (72.3 cm)

F.

1823/32" (47.6 cm)

D. 1423/32" (37.4 cm)

G. 321/32" (9.3 cm)

36" (91.4 cm) Cooktop – for standard and electric models

B

A.203/4" (52.7 cm) screw head to screw head

B.Model/serial rating/clearance plate location

C.221/16" (56.0 cm) without stainless steel trim or 221/2" (57.2 cm) or 23" (58.5 cm) with stainless steel trim (depending on model)

 

A

G

 

F

 

E

 

D

B

 

C

A.

365/16" (92.3 cm)

E. 2" (5.1 cm) recommended minimum

B.

1119/32" (29.4 cm)

cabinet to motor clearance

C. 3411/64" (86.8 cm)

F. 1823/32" (47.6 cm)

D. 1423/32" (37.4 cm)

G. 321/32" (9.3 cm)

3

Cabinet Dimensions

A

D

C B

L E F G

H

I

KJ

A.30" (76.2 cm) on 30" (76.2 cm) models 36" (91.4 cm) on 36" (91.4 cm) models

B.Combustible area above countertop (shown by dashed box above)

C.30" (76.2 cm) minimum clearance between top of cooktop platform and bottom of uncovered wood or metal cabinet (24" [61 cm] minimum clearance if bottom of wood or metal cabinet is covered by not less than 1/4" [0.6 cm] flame retardant millboard covered with not less than No. 28 MSG sheet steel, 0.015" [0.04 cm] stainless steel, 0.024" [0.06 cm] aluminum, or 0.020" [0.05 cm] copper)

D.13" (33 cm) recommended upper cabinet depth

E.2" (5.1 cm)

F.211/8" (53.7 cm)

G.18" (45.7 cm) minimum clearance from upper cabinet to countertop within minimum horizontal clearances to cooktop

H.Junction box or outlet: 12" (30.5 cm) minimum from bottom of countertop

I.Junction box or outlet; 10" (25.4 cm) from right-hand side of cabinet

J.287/8" (73.3 cm) on 30" (76.2 cm) models 349/16" (87.8 cm) on 36" (91.4 cm) models

K.21/2" (6.4 cm) minimum distance to nearest left and right side combustible surface above cooktop

L.11/2" (3.8 cm) minimum clearance between back wall and countertop

NOTES: After making the countertop cutout, some installations may require notching down the base cabinet side walls to clear the cooktop base. To avoid this modification, use a base cabinet with sidewalls wider than the cutout.

■■ A minimum side clearance of 6" (15.2 cm) is recommended between side of cooktop and side wall for maximum ventilation performance.

■■ A minimum clearance of 2" (5.1 cm) is recommended between the motor/blower and cabinet for proper cooling. A 6" (15.2 cm) clearance is recommended for servicing access.

Cutout Dimensions

A B

D

C

E

F

H

I

J

G

A.287/8" (73.3 cm) maximum on 30" (76.2 cm) models 349/16" (87.8 cm) maximum on 36" (91.4 cm) models

B.211/8" (53.7 cm) maximum on both 30" (76.2 cm) and 36" (91.4 cm) models

C.819/32" (21.8 cm) on 30" (76.2 cm) models 157/16" (39.2 cm) on 36" (91.4 cm) models

D.619/64" (16.0 cm) on both 30" (76.2 cm) and 36" (91.4 cm) models

E.2" (5.1 cm) minimum space to front edge of cooktop

F.Floor exhaust option

G.61/8" (15.6 cm) for 6" (15.2 cm) vent system 51/8" (13 cm) for 5" (12.7 cm) vent system

H.819/32" (21.8 cm) on 30" (76.2 cm) models 157/16" (39.2 cm) on 36" (91.4 cm) models

I.16" (40.6 cm) on both 30" (76.2 cm) and 36" (91.4 cm) models

J.Wall exhaust option

Venting Requirements

IMPORTANT: This cooktop must be exhausted outdoors unless using the Duct-Free Filter Accessory Kit. See the “Venting Methods” section.

■■ Do not terminate the vent system in an attic or other enclosed area.

■■ Use a vent cap.

■■ Vent system must terminate to the outside.

■■ Use only a 6" (15.2 cm) diameter round or 31/4" x 10"

(8.3 cm x 25.4 cm) rectangular vent except as follows: For electric cooktops, a 5" (12.7 cm) diameter round vent may be used for venting straight out the back of the cooktop and directly through the wall for 10 ft (3.0 m) or less.

■■ Before making cutouts, make sure there is proper clearance within the wall or floor for the exhaust vent.

■■ Do not cut a joist or stud unless absolutely necessary. If a joist or stud must be cut, then a supporting frame must be constructed.

■■ The size of the vent should be uniform.

■■ The vent system must have a damper. If roof or wall cap has a damper, do not use damper supplied with the range hood.

■■ Use vent clamps to seal all joints in the vent system.

■■ Use caulking to seal exterior wall or roof opening around the cap.

■■ Determine which venting method is best for your application.

4

For Best Performance:

■■ Use 26-gauge minimum galvanized or 25-gauge minimum aluminum metal vent. Poor quality pipe fittings can reduce airflow. Flexible metal vent is not recommended.

NOTE: Local codes may require a heavier gauge material.

■■ Metal duct may be reduced to 30-gauge galvanized steel or 26-gauge aluminized steel if allowed by local codes. This reduction is based on information in the International Residential Codes Section M1601.1 (2006 edition).

■■ Do not install 2 elbows together.

■■ Use no more than three 90° elbows.

■■ If an elbow is used, install it as far away as possible from the hood’s vent motor exhaust opening.

■■ Make sure there is a minimum of 18" (45.7 cm) of straight vent between the elbows if more than one elbow is used.

■■ Elbows too close together can cause excess turbulence that reduces airflow.

■■ Do not use a 5" (12.7 cm) elbow in a 6" (15.2 cm) or 31/4" x 10" (8.3 cm x 25.4 cm) system.

■■ Do not reduce to a 5" (12.7 cm) system after using 6" (15.2 cm) or 31/4" x 10" (8.3 cm x 25.4 cm) fittings.

■■ Avoid forming handmade crimps. Handmade crimps may restrict airflow.

■■ Use a vent cap for proper performance. If an alternate wall or roof cap is used, be certain the cap size is not reduced and that it has a backdraft damper.

■■ Use vent clamps to seal all joints in the vent system.

■■ Use caulking to seal exterior wall or roof opening around the cap.

The length of vent system and number of elbows should be kept to a minimum to provide efficient performance.

The maximum equivalent length of the vent system is 60 ft (18.3 m). For altitudes above 4,500 ft (1372 m), reduce recommended vent run by 20% for best performance.

Cold Weather Installations

An additional backdraft damper should be installed to minimize backward cold air flow.

Makeup Air

Local building codes may require the use of makeup air systems when using ventilation systems greater than specified CFM of air movement. The specified CFM varies from locale to locale. Consult your HVAC professional for specific requirements in your area.

Venting Methods

Common venting methods are shown for a counter-mounted downdraft cooktop. The cooktop may be vented through the wall or floor.

Option 1 – Roof Venting

Option 2 – Wall Venting

B

B

A

 

 

 

 

 

 

 

 

 

A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A. 6" (15.2 cm) round roof venting

A. 6" (15.2 cm) round wall venting

B. Roof cap

B. Wall cap

Option 3 – Venting

Option 4 – Venting Behind

Between Floor Joists

Cabinet Kick Plate

A

B

3¼" x 10"

A (8.3 cm x 25.4 cm) B

A.

Wall cap

A.

Wall cap

B.

6" (15.2 cm) round wall venting

B.

6" (15.2 cm) round wall venting

5

Concrete Slab Installations – Exhaust Through Wall

 

 

B

 

A

 

 

D

 

 

 

N

 

C

E

 

F

 

 

 

M

 

 

H G

 

 

I

 

 

 

 

L

 

K

 

 

J

 

 

 

A.Wall cap

B.6" (15.2 cm) round metal vent

C.16" (40.6 cm) maximum

D.6" (15.2 cm) round PVC sewer pipe

E.6" (15.2 cm) round metal duct

F.6" (15.2 cm) round PVC coupling

G.Concrete slab

H.6" (15.2 cm) round PVC sewer pipe

I.6" (15.2 cm) round 90° PVC sewer pipe elbow

J.Tightly pack gravel or sand completely around pipe.

K.30 ft (9.1 m) max.

L.6" (15.2 cm) round 90° PVC sewer pipe elbow

M.6" (15.2 cm) round PVC coupling

N.12" (30.5 cm) minimum

Duct-Free Filter Accessory Kit

On select downdraft models, the Duct-Free Filter Accessory Kit Part Number JDA7000WX is now available. Duct-Free Filter Accessory Kit is ideal for both new construction and kitchen renovation projects because it provides an easy alternative to the installation of metal ducting and venting in the downdraft

system outside the home. The kit includes all required hardware, one filter and complete installation instructions.Calculating Vent System Length

To calculate the length of the system you need, add the equivalent feet (meters) for each vent piece used in the system.

Vent Piece

6" (15.2 cm) Round

45° elbow

2.5 ft

 

(0.8 m)

 

 

90° elbow

5.0 ft

 

(1.5 m)

 

 

6" (15.2 cm) wall cap

0.0 ft

 

(0.0 m)

 

 

31/4" x 10" (8.3 cm x 25.4 cm)

4.5 ft

to 6" (15.2 cm) transition

(1.4 m)

 

 

 

6" (15.2 cm) to 31/4" x 10"

1 ft

(8.3 cm x 25.4 cm) transition

(0.3 m)

 

 

 

31/4" x 10" (8.3 cm x 25.4 cm)

5.0 ft

to 6" (15.2 cm) 90° elbow

(1.5 m)

transition

 

 

 

6" (15.2 cm) to 31/4" x 10"

5.0 ft

(8.3 cm x 25.4 cm) 90° elbow

(1.5 m)

transition

 

 

 

31/4" x 10" (8.3 cm x 25.4 cm)

5.0 ft

90° elbow

(1.5 m)

 

 

 

31/4" x 10" (8.3 cm x 25.4 cm)

12.0 ft

flat elbow

(3.7 m)

 

 

 

31/4" x 10" (8.3 cm x 25.4 cm)

0.0 ft

wall cap

(0.0 m)

 

 

 

6