Alignment Information

Model : GRUNDIG SC690

Ref. No. : SC690

Date : 16 FEB 2000

A)FM Radio section

1)FM IF

INPUT

SIGNAL

OUTPUT

SET RADIO

ADJUST

ADJUST FOR

REMARK

TP8

10.7MHz

TP3,4

Quiet Point

T101,102

Max. o/p symmetrical

Vol. at min. position

2)

RF VOLTAGE

 

 

 

 

 

 

BAND

SIGNAL

OUTPUT

SET RADIO

ADJUST

ADJUST FOR

REMARK

 

FM

- -

TP2,5

108MHz

L102

1.7V~ 2.3V

high end 7.3V ~7.7V

3)

FM RF

 

 

 

 

 

 

 

INPUT

SIGNAL

OUTPUT

SET RADIO

ADJUST

ADJUST FOR

REMARK

 

TP1,2

90MHz

Speaker

90MHz

L101

Max. o/p

Vol. at max. position

 

TP1,2

106MHz

„ „

106MHz

TC102

„ „

„ „

4)

75KHZ CRYSTAL

 

 

 

 

 

 

 

OUTPUT

 

ADJUST

ADJUST FOR

REMARK

 

 

 

TP6,7

 

CHECK ONLY

75KHz± 10HZ

 

 

5)1.8432MHZ CRYSTAL

OUTPUT

ADJUST

ADJUST FOR

REMARK

TC201

TC201

1.8432MHz± 10HZ

 

Note :

1.Use the digital meter to measure each required voltage on the above items

2.Use weak signal in RF alignment

3.Radio & LCD board must be connected before alignment

4.Use the frequency counter to measure each required frequency on the about items.

SonoClock 690