REPAIR PARTS
GMH95 95% Upflow Hybrid Furnace
GMH950453BXAD
GMH950453BXAE
GMH950453BXAF
GMH950703BXAE
GMH950703BXAF
GMH950703BXAG
GMH950704CXAD
GMH950704CXAE
GMH950704CXAF
GMH950904CXAE
GMH950904CXAF
GMH950904CXAG
GMH950905CXAB
GMH950905CXAC
GMH950905DXAD
GMH950905DXAE
GMH951155DXAE
GMH951155DXAF
GMH951155DXAG
This manual is to be used by qualified technicians only. |
|
This manual replaces RP-718. |
|
|
© 2012-2013 Goodman Manufacturing Company, L.P. ◊ 5151 San Felipe, Suite 500 ◊ Houston, TX 77056 |
||
|
|
|
|
RP-718A |
www.goodmanmfg.com |
www.amana-hac.com |
June 2013 |
Important Information |
|
Index |
|
Functional Parts List ................................................................................................... |
3 |
Illustration and Parts ................................................................................................... |
4 - 13 |
Views shown are for parts illustrations only, not servicing procedures |
|
Text Codes:
AR - As Required
NA - Not Available
NS - Not Shown
00000000 - See Note
QTY - Quantity |
Example (QTY 3) (If Quantity not shown, Quantity = 1) |
|
M - Model |
Example (M1) (If M Code not shown, then part is used on all Models) |
|
Expanded Model Nomenclature: |
||
|
|
|
Example |
|
|
M1 - Model#1 |
|
|
M2 - Model#2 |
|
|
M3 - Model#3 |
|
|
|
|
|
Goodman Manufacturing Company, L.P. is not responsible for personal injury or property damage resulting from improper service. Review all service information before beginning repairs.
Warranty service must be performed by an authorized technician, using authorized factory parts. If service is required after the warranty expires, Goodman Manufacturing Company, L.P. also recommends contacting an authorized technician and using authorized factory parts.
Goodman Manufacturing Company, L.P. reserves the right to discontinue, or change at any time, specifications or designs without notice or without incurring obligations.
For assistance within the U.S.A. contact:
Consumer Affairs Department Goodman Manufacturing Company, L.P. 7401 Security Way
Houston, Texas 77040 877-254-4729-Telephone 713-863-2382-Facsimile
For assistance outside the U.S.A. contact:
International Division
Goodman CompManufany,cturingL.P.Company, L.P.
7401 Security Way
Houston, Texas 77040 713-861-2500-Telephone 713-863-2382-Facsimile
2 |
www.goodmanmfg.com |
www.amana-hac.com |
RP-718A |
Functional Parts
Part
No: Description:
Expanded Model Nomenclature
10735102 |
BECKETT BURNER (QTY A/R) |
0131F00022 |
BLOWER MOTOR 1/2 HP, 4 SP, 6 PL (M7, |
|
M8, M9, M10, M11, M12) |
0131F00020 |
BLOWER MOTOR 1/3 HP, 4 SP, 6 PL (M1, |
|
M2, M3, M4, M5, M6) |
10759415 |
BLOWER MOTOR 3/4 HP, 4 SP, 8 PL (M13, |
|
M14, M15, M16, M17, M18, M19) |
D6723311 |
BLOWER WHEEL (M13, M14, M15, M16, M17, |
|
M18, M19) |
B1368047 |
BLOWER WHEEL 10 X 10 (M7, M8, M9, M10, |
|
M11, M12) |
B1368058 |
BLOWER WHEEL 10 X 8 (M1, M2, M3, M4, |
|
M5, M6) |
CAP125000370VA |
CAPACITOR 12.5/370V (M1, M2, M3, M4, M5, |
|
M6) |
CAP150000370VA |
CAPACITOR 15/370V (M13, M14, M15, M16, |
|
M17, M18, M19) |
CAP200000370VA |
CAPACITOR 20/370V (M7, M8, M9, M10, M11, |
|
M12) |
0130F00010 |
FLAME SENSOR |
0257F00140 |
HEAT EXCHANGER ASSY 4B (M15, M16) |
0257F00180 |
HEAT EXCHANGER ASSY 5B (M17, M18, |
|
M19) |
0257F00143 |
HT EX ASSY 2B FUR (M1, M2, M3) |
0257F00146 |
HT EX ASSY 3B FUR (M7, M8, M9) |
0257F00178 |
HT EX ASSY 3B FUR (M4, M5, M6) |
0257F00179 |
HT EX ASSY 4B FUR (M10, M11, M12, M13, |
|
M14) |
0130F00008 |
IGNITOR-SINI 17 SEC |
0130F00105 |
LIMIT SWITCH (M13, M14) |
10123519 |
MANUAL RESET LIMIT (M17, M18, M19) |
10123517 |
MANUAL RESET LIMIT (M13, M14) |
10123535 |
MANUAL RESET LIMIT-RED (M1, M2, M3, M4, |
|
M5, M6, M7, M8, M9, M10, M11, M12, M15, |
|
M16) |
10123533 |
MANUAL RESET LIMIT-YELLOW (M1, M2, |
|
M3, M4, M5, M6, M7, M8, M9, M10, M11, M12, |
|
M15, M16, M17, M18, M19) |
PCBBF132 |
PCB 2STAGE HYBRID FUR |
0130F00110 |
PRESSURE SWITCH - GREEN (M13, M14) |
0130F00001P |
PRESSURE SWITCH-GRAY (M10, M11, M12) |
0130F00002P |
PRESSURE SWITCH-OLIVE (M4, M5, M6) |
0130F00000P |
PRESSURE SWITCH-SUNGOLD (M1, M2, M3, |
|
M7, M8, M9, M15, M16, M17, M18, M19) |
20197308 |
PRESSURE SWITCH-YELLOW |
20162903 |
PRIMARY LIMIT - BLUE (M4, M5, M6, M7, M8, |
|
M9, M15, M16, M17, M18, M19) |
0130F00038 |
PRIMARY LIMIT - LT BLUE 120º (M13, M14) |
20162904 |
PRIMARY LIMIT-TEMPERATURE CONTROL |
|
(M1, M2, M3, M10, M11, M12) |
B1141605 |
TRANSFORMER 120V TO 24V, 40 VA |
0151M00028 |
VALVE,GAS(HW)VR92 |
SPECIAL PARTS
0161F00000P GOODMAN NAMEPLATE
M1 - GMH950453BXAD
M2 - GMH950453BXAE
M3 - GMH950453BXAF
M4 - GMH950703BXAE
M5 - GMH950703BXAF
M6 - GMH950703BXAG
M7 - GMH950704CXAD
M8 - GMH950704CXAE
M9 - GMH950704CXAF
M10 - GMH950904CXAE
M11 - GMH950904CXAF
M12 - GMH950904CXAG
M13 - GMH950905CXAB
M14 - GMH950905CXAC
M15 - GMH950905DXAD
M16 - GMH950905DXAE
M17 - GMH951155DXAE
M18 - GMH951155DXAF
M19 - GMH951155DXAG
RP-718A |
www.goodmanmfg.com www.amana-hac.com |
3 |
Cabinet
4 |
www.goodmanmfg.com www.amana-hac.com |
RP-718A |