Goodman GMVC960603BNA User Manual

0 (0)
Goodman GMVC960603BNA User Manual

GMVC96

Two-Stage,Variable-Speed

ECMGasFurnace

Upto96%AFUE

Contents

 

Nomenclature........................................

2

Product Specifications...........................

3

Dimensions.............................................

4

Airflow Data............................................

5

Wiring Diagrams.....................................

9

Accessories...........................................

10

Standard Features

Cabinet Features

ComfortNetCommunicating System compatible

Heavy-duty aluminized-steel tubular heat exchanger

Stainless-steel secondary heat exchanger

Two-stage gas valve provides quiet, economical heating

Durable Silicon Nitride igniter

Quiet two-speed induced draft blower

Utilizes ComfortNetcommunicating, two-stage or single-stage thermostats

Self-diagnostic control board with constant memory fault code history output to a dual 7-segment display

Color-coded low-voltage terminals with provisions for electronic air cleaner and humidifier

Efficient and quiet variable-speed airflow system gently ramps up or down according to heating or cooling demand

Multiple continuous fan speed options offer quiet air circulation

Auto-Comfort and enhanced dehumidification modes available

All models comply with California 40 ng/J Low NOx emissions standard

Designed for multi-position installation — upflow, horizontal left or right

Certified for direct vent (2-pipe) or non-direct vent (1-pipe)

Easy to install top venting with optional side venting

Convenient left or right connection for gas and electrical service

Cabinet air leakage(QLeak) ≤ 2%

Heavy-gauge steel cabinet with durable baked-enamel finish

Fully insulated heat exchanger and blower section

Airtightsolidbottomorside-returnwitheasy-cuttabs foreffortlessremovalinbottomair-inletapplications

ENERGYSTAR®andtheENERGYSTARmarkareregisteredtrademarks ownedbytheU.S.EnvironmentalProtectionAgency.ENERGYSTAR productsarethird-partycertifiedbyanEPA-recognizedCertification Body. ProductsthatearntheENERGYSTARpreventgreenhousegas emissions by meeting strict energy efficiency guidelines set by the U.S.EnvironmentalProtectionAgency.

*Complete warranty details available from your local dealer or at www.goodmanmfg.com. To receive the Lifetime Heat Exchanger Limited Warranty (good for as long as you own your home), 10-Year Unit Replacement Limited Warranty and 10-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. Online registration is not required in California or Québec.

SS-GMVC96

www.goodmanmfg.com

12/15

Supersedes 8/15

Nomenclature

 

 

 

 

 

 

 

 

 

 

 

 

 

G

M

V

C

96

060

3

B

N

A

A

 

 

1

2

3

4

5,6

7,8,9

10

11

12

13

14

Brand

 

 

 

 

 

 

 

 

 

 

Minor Revision

G

Goodman® Brand

 

 

 

 

 

 

 

 

 

A -­ Initial Release

 

 

 

 

 

 

 

 

 

 

 

 

B -­ 1st Revision

Configuration

 

 

 

 

 

 

 

 

 

 

 

M

Upflow/Horizontal

 

 

 

 

 

 

 

 

 

Major Revision

C

Downflow/Horizontal

 

 

 

 

 

 

 

 

 

A -­ Initial Release

 

 

 

 

 

 

 

 

 

 

 

 

B -­ 1st Revision

Motor

 

 

 

 

 

 

 

 

 

 

 

V Variable Speed ECM / ComfortNet

 

 

 

 

 

 

 

 

NOx

E

Multi-­Speed ECM

 

 

 

 

 

 

 

 

 

N -­ Low NOx

S

Single Speed

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cabinet Width

Gas Valve

 

 

 

 

 

 

 

 

 

 

B -­ 17.5"

M

Modulating

 

 

 

 

 

 

 

 

 

 

C -­ 21"

C

Two Stage

 

 

 

 

 

 

 

 

 

 

D -­ 24.5"

S

Single Stage

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Maximum CFM

AFUE

 

 

 

 

 

 

 

 

 

 

2 -­ 800 CFM

92

92% AFUE

 

 

 

 

 

 

 

 

 

 

3 -­ 1200 CFM

96

96% AFUE

 

 

 

 

 

 

 

 

 

 

4 -­ 1600 CFM

97 97-­98% AFUE

 

 

 

 

 

 

 

 

 

 

5 -­ 2000 CFM

MBTU/h

 

 

 

 

 

 

 

 

 

 

 

040 -­ 40,000 BTU/h

080 -­ 80,000 BTU/h

 

120 -­ 120,000 BTU/h

 

 

 

 

 

060 -­ 60,000 BTU/h

100 -­ 100,000 BTU/h

 

 

 

 

 

 

 

 

 

Accessories

Model

Description

GMVC96

GMVC96

GMVC96

GMVC96

GMVC96

GMVC96

0403BNA

0603BNA

0803BNA

0804CNA

1005CNA

1205DNA

 

 

CTK04

ComfortNet-compatible Control

 

 

 

 

 

 

 

 

CVENT-2

Concentric Vent Kit (2")

 

 

 

 

 

 

 

 

CVENT-3

Concentric Vent Kit (3")

 

 

 

 

 

 

 

 

CFSB17

Downflow Sub-Base 17.5"

---

---

---

---

---

---

 

 

 

 

 

 

 

 

CFSB21

Downflow Sub-Base 21"

---

---

---

---

---

---

 

 

 

 

 

 

 

 

CFSB24

Downflow Sub-Base 24"

---

---

---

---

---

---

 

 

 

 

 

 

 

 

RF000142

Drain Kit -Horizontal Left Vertical Flue

 

 

 

 

 

 

 

 

EFR02

External Filter Rack with 16"x25" Permanent Filter

---

---

 

 

 

 

 

 

 

 

0170K00000S

Flush Mount Vent Kit - 3" or 2"

 

 

 

 

 

 

 

 

0170K00001S

Flush Mount Vent Kit - 2"

 

 

 

 

 

 

 

 

AFE18-60A

Fossil Fuel (Dual Fuel) Kit

 

 

 

 

 

 

 

 

HASFK

High-Altitude Natural Gas Kit

HASFK-1

HASFK-1

HASFK-2

HASFK-2

HASFK-3

HASFK-2

 

 

 

 

 

 

 

 

HASFK

High-Altitude LP Gas Kit

HASFK-1

HASFK-1

HASFK-1

HASFK-2

HASFK-2

HASFK-2

 

 

 

 

 

 

 

 

LPLP03

Low LP Gas Pressure Switch

 

 

 

 

 

 

 

 

LPM-08

LP Conversion Kits

 

 

 

 

 

 

 

 

2

www.goodmanmfg.com

SS-GMVC96

Product Specifications

 

GMVC96

GMVC96

GMVC96

GMVC96

GMVC96

GMVC96

 

0403BNA

0603BNA

0803BNA

0804CNA

1005CNA

1205DNA

 

 

 

 

 

 

 

HeatingData

 

 

 

 

 

 

High Fire Input¹

40,000

60,000

80,000

80,000

100,000

120,000

High Fire Output¹

38,400

57,600

76,800

76,800

96,000

115,200

Low-Fire Steady-State Input¹

28,000

42,000

56,000

56,000

70,000

84,000

Low-Fire Steady-State Output¹

26,880

40,320

53,760

53,760

67,200

80,640

AFUE²

96

96

96

96

96

96

Temperature Rise Range (°F)

20 - 50

20 - 50

35 - 65

25 - 55

35 - 65

35 - 65

Vent Diameter³

2" - 3"

2" - 3"

2" - 3"

2" - 3"

2" - 3"

2" - 3"

No. of Burners

2

3

4

4

5

6

 

 

 

 

 

 

 

CirculatorBlower

 

 

 

 

 

 

Available AC @ 0.5" ESP

1.5 - 3

1.5 - 3

1.5 - 3

1.5 - 4

2 - 5

2 - 5

Size (D x W)

10" x 8"

11" x 8"

11" x 8"

11" x 10"

11" x 10"

11" x 11"

Horsepower @ 1075 RPM

½

½

½

¾

1

1

Speed

VS ECM

VS ECM

VS ECM

VS ECM

VS ECM

VS ECM

 

 

 

 

 

 

 

ElectricalData

 

 

 

 

 

 

Min. Circuit Ampacity

7.8

7.8

7.8

10.6

14.4

14.4

Max. Overcurrent Device (amps)

15

15

15

15

20

20

 

 

 

 

 

 

 

ShippingWeight(lbs)

114

117

120

141

143

156

¹Natural Gas BTU/h

²DOE AFUE based upon Isolated Combustion System (ICS)

³Installer must supply one or two PVC pipes: one for combustion air (optional) and one for the flue outlet (required). Vent pipe must be either 2" or 3" in diameter, depending upon furnace input, number of elbows, length of run and installation (1 or 2 pipes). The optional Combustion Air Pipe is dependent on installation/code requirements and must be 2" or 3" diameter PVC.

Minimum Circuit Ampacity = (1.25 x Circulator Blower Amps) + ID Blower amps. Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes.

Maximum Overcurrent Protection Device refers to maximum recommended fuse or circuit breaker size. May use fuses or HACR-type circuit breakers of the same size as noted.

Notes

All furnaces are manufactured for use on 115 VAC, 60 Hz, single-phase electrical supply.

Gas Service Connection ½" FPT

Important: Size fuses and wires properly and make electrical connections in accordance with the National Electrical Code and/or all existing local codes.

For bottom return: Failure to unfold flanges may reduce airflow by up to 18%. This could result in performance and noise issues.