GMVC96
Two-Stage,Variable-Speed
ECMGasFurnace
Upto96%AFUE |
|
Contents |
|
Nomenclature........................................ |
2 |
Product Specifications........................... |
3 |
Dimensions............................................. |
4 |
Airflow Data............................................ |
5 |
Wiring Diagrams..................................... |
9 |
Accessories........................................... |
10 |
Standard Features |
Cabinet Features |
•ComfortNet™ Communicating System compatible
•Heavy-duty aluminized-steel tubular heat exchanger
•Stainless-steel secondary heat exchanger
•Two-stage gas valve provides quiet, economical heating
•Durable Silicon Nitride igniter
•Quiet two-speed induced draft blower
•Utilizes ComfortNet™ communicating, two-stage or single-stage thermostats
•Self-diagnostic control board with constant memory fault code history output to a dual 7-segment display
•Color-coded low-voltage terminals with provisions for electronic air cleaner and humidifier
•Efficient and quiet variable-speed airflow system gently ramps up or down according to heating or cooling demand
•Multiple continuous fan speed options offer quiet air circulation
•Auto-Comfort and enhanced dehumidification modes available
•All models comply with California 40 ng/J Low NOx emissions standard
•Designed for multi-position installation — upflow, horizontal left or right
•Certified for direct vent (2-pipe) or non-direct vent (1-pipe)
•Easy to install top venting with optional side venting
•Convenient left or right connection for gas and electrical service
•Cabinet air leakage(QLeak) ≤ 2%
•Heavy-gauge steel cabinet with durable baked-enamel finish
•Fully insulated heat exchanger and blower section
•Airtightsolidbottomorside-returnwitheasy-cuttabs foreffortlessremovalinbottomair-inletapplications
ENERGYSTAR®andtheENERGYSTARmarkareregisteredtrademarks ownedbytheU.S.EnvironmentalProtectionAgency.ENERGYSTAR productsarethird-partycertifiedbyanEPA-recognizedCertification Body. ProductsthatearntheENERGYSTARpreventgreenhousegas emissions by meeting strict energy efficiency guidelines set by the U.S.EnvironmentalProtectionAgency.
*Complete warranty details available from your local dealer or at www.goodmanmfg.com. To receive the Lifetime Heat Exchanger Limited Warranty (good for as long as you own your home), 10-Year Unit Replacement Limited Warranty and 10-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. Online registration is not required in California or Québec.
SS-GMVC96 |
www.goodmanmfg.com |
12/15 |
Supersedes 8/15
Nomenclature |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
G |
M |
V |
C |
96 |
060 |
3 |
B |
N |
A |
A |
|
|
1 |
2 |
3 |
4 |
5,6 |
7,8,9 |
10 |
11 |
12 |
13 |
14 |
Brand |
|
|
|
|
|
|
|
|
|
|
Minor Revision |
|
G |
Goodman® Brand |
|
|
|
|
|
|
|
|
|
A - Initial Release |
|
|
|
|
|
|
|
|
|
|
|
|
|
B - 1st Revision |
Configuration |
|
|
|
|
|
|
|
|
|
|
|
|
M |
Upflow/Horizontal |
|
|
|
|
|
|
|
|
|
Major Revision |
|
C |
Downflow/Horizontal |
|
|
|
|
|
|
|
|
|
A - Initial Release |
|
|
|
|
|
|
|
|
|
|
|
|
|
B - 1st Revision |
Motor |
|
|
|
|
|
|
|
|
|
|
|
|
V Variable Speed ECM / ComfortNet |
|
|
|
|
|
|
|
|
NOx |
|||
E |
Multi-Speed ECM |
|
|
|
|
|
|
|
|
|
N - Low NOx |
|
S |
Single Speed |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Cabinet Width |
Gas Valve |
|
|
|
|
|
|
|
|
|
|
B - 17.5" |
|
M |
Modulating |
|
|
|
|
|
|
|
|
|
|
C - 21" |
C |
Two Stage |
|
|
|
|
|
|
|
|
|
|
D - 24.5" |
S |
Single Stage |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Maximum CFM |
AFUE |
|
|
|
|
|
|
|
|
|
|
2 - 800 CFM |
|
92 |
92% AFUE |
|
|
|
|
|
|
|
|
|
|
3 - 1200 CFM |
96 |
96% AFUE |
|
|
|
|
|
|
|
|
|
|
4 - 1600 CFM |
97 97-98% AFUE |
|
|
|
|
|
|
|
|
|
|
5 - 2000 CFM |
|
MBTU/h |
|
|
|
|
|
|
|
|
|
|
|
|
040 - 40,000 BTU/h |
080 - 80,000 BTU/h |
|
120 - 120,000 BTU/h |
|
|
|
|
|
||||
060 - 60,000 BTU/h |
100 - 100,000 BTU/h |
|
|
|
|
|
|
|
|
|
Accessories
Model |
Description |
GMVC96 |
GMVC96 |
GMVC96 |
GMVC96 |
GMVC96 |
GMVC96 |
|
0403BNA |
0603BNA |
0803BNA |
0804CNA |
1005CNA |
1205DNA |
|||
|
|
|||||||
CTK04 |
ComfortNet-compatible Control |
√ |
√ |
√ |
√ |
√ |
√ |
|
|
|
|
|
|
|
|
|
|
CVENT-2 |
Concentric Vent Kit (2") |
√ |
√ |
√ |
√ |
√ |
√ |
|
|
|
|
|
|
|
|
|
|
CVENT-3 |
Concentric Vent Kit (3") |
√ |
√ |
√ |
√ |
√ |
√ |
|
|
|
|
|
|
|
|
|
|
CFSB17 |
Downflow Sub-Base 17.5" |
--- |
--- |
--- |
--- |
--- |
--- |
|
|
|
|
|
|
|
|
|
|
CFSB21 |
Downflow Sub-Base 21" |
--- |
--- |
--- |
--- |
--- |
--- |
|
|
|
|
|
|
|
|
|
|
CFSB24 |
Downflow Sub-Base 24" |
--- |
--- |
--- |
--- |
--- |
--- |
|
|
|
|
|
|
|
|
|
|
RF000142 |
Drain Kit -Horizontal Left Vertical Flue |
√ |
√ |
√ |
√ |
√ |
√ |
|
|
|
|
|
|
|
|
|
|
EFR02 |
External Filter Rack with 16"x25" Permanent Filter |
√ |
√ |
√ |
√ |
--- |
--- |
|
|
|
|
|
|
|
|
|
|
0170K00000S |
Flush Mount Vent Kit - 3" or 2" |
√ |
√ |
√ |
√ |
√ |
√ |
|
|
|
|
|
|
|
|
|
|
0170K00001S |
Flush Mount Vent Kit - 2" |
√ |
√ |
√ |
√ |
√ |
√ |
|
|
|
|
|
|
|
|
|
|
AFE18-60A |
Fossil Fuel (Dual Fuel) Kit |
√ |
√ |
√ |
√ |
√ |
√ |
|
|
|
|
|
|
|
|
|
|
HASFK |
High-Altitude Natural Gas Kit |
HASFK-1 |
HASFK-1 |
HASFK-2 |
HASFK-2 |
HASFK-3 |
HASFK-2 |
|
|
|
|
|
|
|
|
|
|
HASFK |
High-Altitude LP Gas Kit |
HASFK-1 |
HASFK-1 |
HASFK-1 |
HASFK-2 |
HASFK-2 |
HASFK-2 |
|
|
|
|
|
|
|
|
|
|
LPLP03 |
Low LP Gas Pressure Switch |
√ |
√ |
√ |
√ |
√ |
√ |
|
|
|
|
|
|
|
|
|
|
LPM-08 |
LP Conversion Kits |
√ |
√ |
√ |
√ |
√ |
√ |
|
|
|
|
|
|
|
|
|
2 |
www.goodmanmfg.com |
SS-GMVC96 |
Product Specifications
|
GMVC96 |
GMVC96 |
GMVC96 |
GMVC96 |
GMVC96 |
GMVC96 |
|
0403BNA |
0603BNA |
0803BNA |
0804CNA |
1005CNA |
1205DNA |
|
|
|
|
|
|
|
HeatingData |
|
|
|
|
|
|
High Fire Input¹ |
40,000 |
60,000 |
80,000 |
80,000 |
100,000 |
120,000 |
High Fire Output¹ |
38,400 |
57,600 |
76,800 |
76,800 |
96,000 |
115,200 |
Low-Fire Steady-State Input¹ |
28,000 |
42,000 |
56,000 |
56,000 |
70,000 |
84,000 |
Low-Fire Steady-State Output¹ |
26,880 |
40,320 |
53,760 |
53,760 |
67,200 |
80,640 |
AFUE² |
96 |
96 |
96 |
96 |
96 |
96 |
Temperature Rise Range (°F) |
20 - 50 |
20 - 50 |
35 - 65 |
25 - 55 |
35 - 65 |
35 - 65 |
Vent Diameter³ |
2" - 3" |
2" - 3" |
2" - 3" |
2" - 3" |
2" - 3" |
2" - 3" |
No. of Burners |
2 |
3 |
4 |
4 |
5 |
6 |
|
|
|
|
|
|
|
CirculatorBlower |
|
|
|
|
|
|
Available AC @ 0.5" ESP |
1.5 - 3 |
1.5 - 3 |
1.5 - 3 |
1.5 - 4 |
2 - 5 |
2 - 5 |
Size (D x W) |
10" x 8" |
11" x 8" |
11" x 8" |
11" x 10" |
11" x 10" |
11" x 11" |
Horsepower @ 1075 RPM |
½ |
½ |
½ |
¾ |
1 |
1 |
Speed |
VS ECM |
VS ECM |
VS ECM |
VS ECM |
VS ECM |
VS ECM |
|
|
|
|
|
|
|
ElectricalData |
|
|
|
|
|
|
Min. Circuit Ampacity |
7.8 |
7.8 |
7.8 |
10.6 |
14.4 |
14.4 |
Max. Overcurrent Device (amps) |
15 |
15 |
15 |
15 |
20 |
20 |
|
|
|
|
|
|
|
ShippingWeight(lbs) |
114 |
117 |
120 |
141 |
143 |
156 |
¹Natural Gas BTU/h
²DOE AFUE based upon Isolated Combustion System (ICS)
³Installer must supply one or two PVC pipes: one for combustion air (optional) and one for the flue outlet (required). Vent pipe must be either 2" or 3" in diameter, depending upon furnace input, number of elbows, length of run and installation (1 or 2 pipes). The optional Combustion Air Pipe is dependent on installation/code requirements and must be 2" or 3" diameter PVC.
Minimum Circuit Ampacity = (1.25 x Circulator Blower Amps) + ID Blower amps. Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes.
Maximum Overcurrent Protection Device refers to maximum recommended fuse or circuit breaker size. May use fuses or HACR-type circuit breakers of the same size as noted.
Notes
•All furnaces are manufactured for use on 115 VAC, 60 Hz, single-phase electrical supply.
•Gas Service Connection ½" FPT
•Important: Size fuses and wires properly and make electrical connections in accordance with the National Electrical Code and/or all existing local codes.
•For bottom return: Failure to unfold flanges may reduce airflow by up to 18%. This could result in performance and noise issues.
•For servicing or cleaning, a 24" front clearance is required. Unit connections (electrical, flue and drain) may necessitate greater clearances than the minimum clearances listed above. In all cases, accessibility
clearance must take precedence over clearances from the enclosure where accessibility clearances are greater.
SS-GMVC96 |
www.goodmanmfg.com |
3 |