REPAIR PARTS
GMP/GMPH
80% Gas Furnace
GMP050-3
GMP050-32
GMP075-3
GMP075-32
GMP075-4
GMP100-3
GMP100-4
GMP100-42
GMP100-5
GMP125-4
GMP125-5
GMP125-52
GMP150-5
GMP150-52
GMPH050-3
GMPH075-4
GMPH080-5
GMPH120-5
|
Goodman Manufacturing Company, L.P. |
|
|
5151 San Felipe, Suite 500 |
|
|
Houston, TX 77056 |
|
® |
www.goodmanmfg.com |
RP-370A |
|
December 2008 |
|
|
|
|
|
|
This manual replaces RP-370. |
This manual is to be used by qualified technicians only. |
Copyright © 1996-2008 Goodman Manufacturing Company, L.P |
Important Information |
|
Index |
|
Functional Parts List ................................................................................................... |
3 |
Illustration and Parts ................................................................................................... |
4 - 11 |
Views shown are for parts illustrations only, not servicing procedures.
Rev. A: Corrected heat exchanger p/ns for GMP075-4 and GMP100-5.
Text Codes:
AR - As Required
NA - Not Available
NS - Not Shown
00000000 - See Note
QTY - Quantity |
Example (QTY 3) (If Quantity not shown, Quantity = 1) |
|
M - Model |
Example (M1) (If M Code not shown, then part is used on all Models) |
|
Expanded Model Nomenclature: |
||
|
|
|
Example |
|
|
M1 - Model#1 |
|
|
M2 - Model#2 |
|
|
M3 - Model#3 |
|
|
|
|
|
Goodman Manufacturing Company, L.P. is not responsible for personal injury or property damage resulting from improper service. Review all service information before beginning repairs.
Warranty service must be performed by an authorized technician, using authorized factory parts. If service is required after the warranty expires, Goodman Manufacturing Company, L.P. also recommends contacting an authorized technician and using authorized factory parts.
Goodman Manufacturing Company, L.P. reserves the right to discontinue, or change at any time, specifications or designs without notice or without incurring obligations.
For assistance within the U.S.A. contact:
Consumer Affairs Department Goodman Manufacturing Company, L.P. 7401 Security Way
Houston, Texas 77040 877-254-4729-Telephone 713-863-2382-Facsimile
For assistance outside the U.S.A. contact:
International Division
Goodman ManufCompany,cturingL.P.Company, L.P.
7401 Security Way Houston, Texas 77040 713-861-2500-Telephone 713-863-2382-Facsimile
Copyright © 1996-2008 Goodman Manufacturing Company, L.P. |
2 |
RP-370A |
Functional Parts
Part |
|
|
|
No: |
Description: |
|
|
|
|
IO-604 |
SPECIAL INSTRUCTIONS W/36G (M1, M2, |
B1809920 |
50 HZ DSI MODULE (M6, M8, M12, M16, M18) |
|
M3, M4, M5, M7, M9, M10, M11, M13, M14, |
|
M15, M17) |
||
|
|
|
|
B13400503S |
BLOWER MOTOR 1/2 HP, 50 HZ (M12) |
IO-616 |
SUPPLEMENTAL INSTRUCTIONS (M6, M8, |
|
|
||
B13400502S |
BLOWER MOTOR 1/4 HP, 50 HZ (M6, M8) |
|
M12, M16, M18) |
|
|
||
B13400523S |
BLOWER MOTOR 3/4 HP, 50 HZ (M16) |
OBSOLETE |
USERS MANUAL (M1, M2, M3, M4, M5, M7, |
|
M9, M10, M11, M13, M14, M15, M17) |
||
|
|
|
|
B13400522S |
BLOWER MOTOR 3/4 HP, 50 HZ, DUAL |
OBSOLETE |
USERS MANUAL (CE) (M6, M8, M12, M16, |
|
SHAFT (M18) |
||
|
|
M18) |
|
|
|
|
B1340020S |
BLOWER MOTOR DIRECT DRIVE 1/2 HP |
|
(M1, M9, M11, M14) |
B1340021S |
BLOWER MOTOR DIRECT DRIVE 1/3 HP |
|
(M5, M7, M10) |
B1340022S |
BLOWER MOTOR DIRECT DRIVE 3/4 HP |
|
(M4, M17) |
B1340023S |
BLOWER MOTOR DIRECT DRIVE 3/4 HP |
|
(M2, M3, M13, M15) |
CAP100000370VAS CAPACITOR 10/370V [BLOWER] (M1, M9, M11, M12, M14)
CAP125000370RPS CAPACITOR 12.5/370V (M2, M3, M5, M7, M10, M13, M15, M16, M18)
CAP150000370VAS CAPACITOR 15/370V (M4, M17)
CAP075000370VAS CAPACITOR 7.5/370V (M6, M8)
B1401014 |
DIRECT SPARK IGNITOR-GMP 50HZ (M6, |
|
M8, M12, M16, M18) |
B1282622 |
GAS VALVE (36E) (M6, M8, M12, M16, M18) |
B1282628 |
GAS VALVE (36G) (M1, M2, M3, M4, M5, M7, |
|
M9, M10, M11, M13, M14, M15, M17) |
B1401018S |
HOT SURFACE IGNITOR (M1, M2, M3, M4, |
|
M5, M7, M9, M10, M11, M13, M14, M15, M17) |
B1809913S |
HSI BOARD W/9-PIN CONNECTOR (M1, M2, |
|
M3, M4, M5, M7, M9, M10, M11, M13, M14, |
|
M15, M17) |
B1141605 |
TRANSFORMER 120V TO 24V, 40 VA (M1, |
|
M2, M3, M4, M5, M7, M9, M10, M11, M13, M14, |
|
M15, M17) |
Expanded Model Nomenclature
M1 - GMPH050-3
M2 - GMPH075-4
M3 - GMPH080-5
M4 - GMPH120-5
M5 - GMP050-3
M6 - GMP050-32
M7 - GMP075-3
M8 - GMP075-32
M9 - GMP075-4
M10 - GMP100-3
M11 - GMP100-4
M12 - GMP100-42
M13 - GMP100-5
M14 - GMP125-4
M15 - GMP125-5
M16 - GMP125-52
M17 - GMP150-5
M18 - GMP150-52
B1141664 |
TRANSFORMER 230V, 50 HZ (M6, M8, M12, |
|
M16, M18) |
B1859005S |
VENT MOTOR & HOUSING (GMP) (M1, M2, |
|
M3, M4, M5, M7, M9, M10, M11, M13, M14, |
|
M15, M17) |
B18590505S |
VENT MOTOR & HOUSING 50 HZ (M6, M8, |
|
M12, M16, M18) |
SPECIAL PARTS
IO-137CE-A |
INSTALLATION INSTRUCTIONS GMP (M5, |
|
M6, M7, M8, M9, M10, M11, M12, M13, M14, |
|
M15, M16, M17, M18) |
IO-163B |
INSTALLATION INSTRUCTIONS GMPH (M1, |
|
M2, M3, M4) |
B10259251 |
LABEL, GOODMAN (M6, M8, M12, M16, M18) |
IO-605 |
LIGHTING INSTRUCTIONS W/36G (M1, M2, |
|
M3, M4, M5, M7, M9, M10, M11, M13, M14, |
|
M15, M17) |
RP-370 |
REPAIR PARTS MANUAL |
3 |
RP-370A |
Cabinet Assy
RP-370A |
4 |