GIGABYTE GS-R1271-RH Owner's Manual

4 (1)

GS-R1271-RH

1U Rack Mount Server

System Installation Guide

Dual Intel® Xeon LGA771 Processor Serverboard

Rev. 1.0

GS-R1271-RH Rack Mount Server

 

Table of Content

 

Safety, Care and Regulatory Information ................................................

4

Introduction ..............................................................................................

8

Contents Packages ................................................................................

8

Chapter 1 Features Summary .................................................................

9

Chapter 2 System Hardware Installation ...............................................

11

Step 2-1: Chassis Removal and Installation .................................................................

11

Step 2-2: CPU Installation ...............................................................................................

12

Step 2-3: Heat Sink Installation .......................................................................................

13

Step 2-4: Memory Installation ........................................................................................

14

Step 2-5: PCI Expansion Card Installation ....................................................................

15

Step 2-6: Hard Disk Drive Installation ............................................................................

16

Step 2-7: FAN Duct Removal and Installation ..............................................................

17

Chapter 3 Appearance of GS-R1271-RH .............................................

18

3-1: Front View of GS-R1271-RH ..................................................................................

18

3-2: Rear View of GS-R1271-RH ..................................................................................

19

3-3: Switch and LED Indicators Introduction .................................................................

20

3-4: LAN LED Description ...............................................................................................

21

3-5: Connector Icon Description .....................................................................................

22

Chapter 4 Motherboard Jumper Setting ...............................................

23

4-1: GA-7NCSV1-RH Motherboard Jumpper Setting ...................................................

23

Chapter 5 BIOS Setup ..........................................................................

27

Main ...........................................................................................................

29

Advanced Processor Options ........................................................................................

31

Advanced ...................................................................................................

34

Memory Configuration .....................................................................................................

35

PnP Configuration ............................................................................................................

36

I/O Device Configuration .................................................................................................

38

Advanced Chipset Control .............................................................................................

40

Security ......................................................................................................

43

TPM State ..................................................................................................

45

2

 

Table of Content

Server .........................................................................................................

46

System Management ......................................................................................................

47

Console Redirection ........................................................................................................

48

Boot ............................................................................................................

50

Exit .............................................................................................................

51

3

GS-R1271-RH Rack Mount Server

Safety, Care and Regulatory Information

/ Important safety information

Read and follow all instructions marked on the product and in the documentation before you operate your system. Retain all safety and operating instructions for future use.

*The product should be operated only from the type of power source indicated on the rating label.

*If your computer has a voltage selector switch, make sure that the switch is in the proper position for your area. The voltage selector switch is set at the factory to the correct voltage.

*The plug-socket combination must be accessible at all times because it serves as the main disconnecting device.

*All product shipped with a three-wire electrical grounding-type plug only fits into a grounding-type power outlet. This is a safety feature. The equipment grounding should be in accordance with local and national electrical codes. The equipment operates safely when it is used in accordance with its marked electrical ratings and product usage instructions

*Do not use this product near water or a heat source.

*Set up the product on a stable work surface or so as to ensure stability of the system.

*Openings in the case are provided for ventilation. Do not block or cover these openings. Make sure you provide adequate space around the system for ventilation when you set up your work area. Never insert objects of any kind into the ventilation openings.

*To avoid electrical shock, always unplug all power cables and modem cables from the wall outlets before removing covers.

*Allow the product to cool before removing covers or touching internal components.

/Precaution for Product with Laser Devices

Observe the following precautions for laser devices:

*Do not open the CD-ROM drive, make adjustments, or perform procedures on a laser device other than those specified in the product's documentation.

*Only authorized service technicians should repair laser devices.

/Precaution for Product with Modems, Telecommunications, ot Local Area Network Options

Observe the following guidelines when working with options:

* Do not connect or use a modem or telephone during a lightning storm. There may be a risk of electrical shock from lightning.

4

Safety Information

*To reduce the risk of fire, use only No. 26 AWG or larger telecommunications line cord.

*Do not plug a modem or telephone cable into the network interface controller (NIC) receptacle.

*Disconnect the modem cable before opening a product enclosure, touching or installing internal components, or touching an uninsulated modem cable or jack.

*Do not use a telephone line to report a gas leak while you are in the vicinity of the leak.

/Federal Communications Commission (FCC) Statement

Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

Properly shielded and grounded cables and connectors must be used in order to meet FCC emission limits. Neither the provider nor the manufacturer are responsible for any radio or television interference caused by using other than recommended cables and connectors or by unauthorized changes or modifications to this equipment. Unauthorized changes or modifications could void the user's authority to operatetheequipment.

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:

(1)this device may not cause harmful interference, and

(2)this device must accept any interference received, including interference that may cause undesired operation.

/ FCC part 68 (applicable to products fitted with USA modems)

The modem complies with Part 68 of the FCC Rules. On this equipment is a label that contains, among other information, the FCC registration number and Ringer Equivalence Number (REN) for this equipment. You must, upon request, provide this information to your telephone company.

If your telephone equipment causes harm to the telephone network, the Telephone Company may discontinue your service temporarily. If possible, they will notify in advance. But, if advance notice is not practical, you will be notified as soon as possible. You will be informed of your right to file a complaint with the FCC.

5

GS-R1271-RH Rack Mount Server

Your telephone company may make changes in its facilities, equipment, operations, or procedures that could affect proper operation of your equipment. If they do, you will be notified in advance to give you an opportunity to maintain uninterrupted telephone service.

The FCC prohibits this equipment to be connected to party lines or coin-telephone service.

The FCC also requires the transmitter of a FAX transmission be properly identified (per FCC Rules Part 68, Sec. 68.381 (c) (3)).

/for Canadian users only /

/Canadian Department of Communications Compliance Statement

This digital apparatus does not exceed the Class B limits for radio noise emissions from digital apparatus as set out in the radio interference regulations of Industry Canada.

Le present appareil numerique n'emet pas de bruits radioelectriques depassant les limites applicables aux appareils numeriques de Classe B prescrites dans le reglement sur le brouillage radioelectrique edicte par Industrie Canada.

/ DOC notice (for products fitted with an Industry Canada-compliant modem)

The Canadian Department of Communications label identifies certified equipment. This certification means that the equipment meets certain telecommunications network protective, operational and safety requirements. The Department does not guarantee the equipment will operate to the user satisfaction.

Before installing this equipment, users ensure that it is permissible to be connected to the facilities of the local Telecommunications Company. The equipment must also be installed using an acceptable method of connection. The customer should be aware that compliance with the above conditions might not prevent degradation of service in some situations.

Repairs to certified equipment should be made by an authorized Canadian maintenance facility designated by the supplier.Any repairs or alterations made by the user to this equipment, or equipment malfunctions, may give the telecommunications company cause to request the user to disconnect the equipment.

Users should ensure for their own protection that the electrical ground connections of the power utility, telephone lines and internal metallic water pipe system, if resent are connected together. This precaution may be particularly important in rural areas.

Caution: Users should not attempt to make such connections themselves, but should contact the appropriate electric inspection authority, or electrician, as appropriate.

6

Safety Information

NOTICE: The Load Number (LN) assigned to each terminal device denotes the percentage of the total load to be connected to a telephone loop which is used by the device, to prevent overloading. The termination on a loop may consist of any combination of devices subject only to the requirement that the sum of the Load Numbers of all the devices does not exceed 100.

/ for European users only /

CAUTION

Danger of explosion if battery is incorrectly replaced.

Replace only with the same or equivalent type recommended by the manufacturer.

Dispose of used batteries according to the manufacturer’sinstructions.

7

GS-R1271-RH Rack Mount Server

Introduction

Welcome to Gigabyte GS-R1271-RH Rack mount Server System Installation Guide. The guide provides instructions for configuration hardware for the GS-R1271-RH your system.

This installation guide will assist you in installing all the essential components for the sever system. For your protection, please read and undertand all of the safety and operating instructions regarding your Gigabyte Server and retain for future reference. The procedures in this guidebook assume that your are a system or network administrator experienced in installing similar hardware.

Contents Packages

When opening the package, please ensure the system components are not damaged during the shipping. Using the following checklist to verify the contents. If any component is missing or damaged in the

system, please contact your vendor immediately.

 

; Chassis

;

GA-7NCSV1-RH Motherboard (Installed)

; Power Supply (Installed)

;

FAN Duct x 1

; CPU Heat Sink x 2

;

Silm type CD-ROM drive (Installed)

; Cables (RJ45)

;

Case Handle Kit x 2

;GS-R1271-RH Quick Refernece Guide

;Driver CD for motherboard driver & utility

* The items listed above are for reference only, and are subject to change without notice.

8

Feature Summary

Chapter 1 Features Summary

Motherboard

y

GA-7NCSV1-RH

 

Processor Supported

y

Supports Dual Intel® Xeon® processor (Hapertown/Wolfdale)

 

 

y

Intel Xeon® Quad-Core/Dual -Core processor in LGA 775 socket

 

y

Supports 1066/1333MHz FSB

 

 

 

 

Chipset

y

Intel® 5100 Chipset

 

y

Intel® ICH9 RAID

System Memory:

 

 

 

Memory Capacity

y

6 x DDR2 DIMM sockets up to 48GB

Memory Type

y

Dual Channel ECC Registered 533/667 memory

DIMM Size

y

Support 256MB, 512MB, 1GB, and 2GB memory

Error Correction:

y

Single-bit Errors Correction, Multiple Bit Errors Detection

 

 

 

 

Expansion Slot

y

1 Riser card supports 1 PCI-E x8 and 1 PCI-E x8 (x1 bandwidth)

 

 

add-on cards

 

y 1 SO-DIMM add-on card

 

 

 

 

SATA RAID controller

y

ICH9R

 

y Supports LSI Software SW RAID 0/1/10 (Windows only)

 

 

 

 

Cooling Fans:

y

5 X System Fan

Integrated LANs:

 

 

 

Controller

y

Intel® 82566DC & 82573VGbE controllers

Integrated Graphics:

 

 

 

Controller

y

XGI Volari Z9s

Graphics Memory

y

32MB DDR2

 

 

 

 

Mass Storage System

y

3 x Hot-Swap SATA HDDs

 

y 1 x slim type CD-ROM

 

y 1 x DVD Combo (optional)

 

 

 

 

Super I/O

 

 

 

Controller

y

ITE IT8718F Super I/O

 

 

 

 

Built-in I/O

y

1 x Serial port (COM)

 

y 4 x USB 2.0 dual-port connector (2 at front panel)

y 1 x VGA connector y 2 x RJ45 LAN ports

y P/S 2 Keyboard and Mouse Connectors

9

GS-R1271-RH Rack Mount Server

System BIOS:

 

BIOS Type

y Phoenix BIOS on 8Mb flash ROM

 

Server Management Functions: (Optional device)

BMC Chip

y H8S IPMI 2.0 controller

Failure Detection

y IPMI 2.0 specification of Server management

Event Logging

y 32KB Nonvolatile Memory to Log System Failure Events

Remote Management

y Follow the IPMI 2.0 specification of Server management

 

 

Environment

 

AmbientTemperature

y Operating Temperature: 5oC to 35oC

 

y Non-operating Temperature: 0oC to 50oC

Relative Humidity

y 10-80% operating Humidity at 30o C

System Dimention:

y 427.5mm x 567.5mm x 43.5 mm

Electrical Power Supply

y Single Power Supply 300W

1 0

Hardware Installation Process

Chapter 2 System Hardware Installation

Please observe the safety information in chapter “Important Safety Information”

Do not expose the server to extreme environmental conditions. Protect it from dust, humidity, and heat.

Step 2-1: Chassis Removal and Installation

Step 1 Push down the indentation located at two sides of the chassis.

Step 2 Slide toward the top chassis cover.

Step 3 Lift up to remove the top chassis cover.

Step 4 Reverse Step 1, ,2, 3 to replace the chassis cover

1

1

3

2

1 1

GS-R1271-RH Rack Mount Server

Step 2-2: CPU Installation

Please make sure the CPU type and speed that are supported by the motherboard.

Step 1 Raise the metal locking lever on the socket. Insert the CPU with the correct orientation. Step 2 The CPU only fits in one orientation.

Step 3 Push the metal lever back into locked position.

1

2 3

1 2

Hardware Installation Process

Step 2-3: Heat Sink Installation

Step 1 Place the Heat Sink on the CPU. Before putting the heat sink on the CPU, please well remember to apply the thermal conductivity compound on the CPU.

Step 2 Seat the heat sink in the retention modules with the four screws. Installation completed.

2

2 2

2

1

1 3

GS-R1271-RH Rack Mount Server

Step 2-4: Memory Installation

Step 1. Insert the DIMM memory module vertically into the DIMM slot, and push it down. Step 2. Close the plastic clip at both edges of the DIMM slots to lock the DIMM module.

NOTE! DIMM must be populated in order starting from DIMM6 socket. For dual-channel operation, DIMMs must be installed in matched pairs.

Step 3. Reverse the installation steps when you wish to remove the DIMM module.

2

1

2

DIMM 1

DIMM 2

DIMM 3

DIMM 4

DIMM 5

DIMM 6

 

 

 

 

 

 

x

x

x

x

Single Rank

Single Rank

 

 

 

 

 

 

x

x

Single Rank

Single Rank

Single Rank

Single Rank

 

 

 

 

 

 

Single Rank

Single Rank

Single Rank

Single Rank

Single Rank

Single Rank

 

 

 

 

 

 

x

x

x

x

Dual Rank

Dual Rank

 

 

 

 

 

 

x

x

Dual Rank

Dual Rank

Dual Rank

Dual Rank

 

 

 

 

 

 

Dual Rank

Dual Rank

Dual Rank

Dual Rank

Dual Rank

Dual Rank

 

 

 

 

 

 

x

x

Dual Rank

Dual Rank

Dual Rank

Dual Rank

 

 

 

 

 

 

x

x

Single Rank

Single Rank

Dual Rank

Dual Rank

 

 

 

 

 

 

Dual Rank

Dual Rank

Single Rank

Single Rank

Single Rank

Single Rank

 

 

 

 

 

 

Dual Rank

Dual Rank

Dual Rank

Dual Rank

Single Rank

Single Rank

 

 

 

 

 

 

1 4

GS-R1271-RH Rack Mount Server

Step 2-5: PCI Expansion Card Installation

GS-R1271-RH provides expansion riser slots for two PCI-E x8 slot. To install the peripheral, please go through the following steps.

Note!! Before installing the expansion card, please check the card size limitation. Size limitation for standard riser card is 182mm; and the size limitation for low profile riser card is 182mm.

Step 1 Loosen the riser bracket screws.

Step 2 Lift the riser bracket slightly, then pull it out from the server chassis.

Step 3 Unlock the screw on the riser bracket to remove the PCI bracket. Align the expansion card with the guiding groove. Slide the expansion card into the slot until the card firmly seats.

Step 4 Reverse step 1 to 3 to reinstall riser bracket into the system module.

3

1

2

3

 

1 5

GIGABYTE GS-R1271-RH Owner's Manual

Hardware Installation Process

Step 2-6: Hard Disk Drive Installation

Step 1 Press the release button.

Step 2 Pull the blank out of the drive bay. Step 3 Slide hard disk into blank.

Step 4 Secure it with screws.

Step 5 Slide the blank into the bay until it locks into place. Connect cable and power.

1

2

3

4

4

4 4

1 6

Hardware Installation Process

Step 2-7: FAN Duct Removal and Installation

Step 1 Pull up the cabled and align the fan duct with the guiding groove. Push down the fan duct into system ntil the its firmly seats.

Step 2 Please push the cables into the gap between fan duct and power supply.

1

Guiding groove

1 7

Loading...
+ 39 hidden pages