GE AHY10LZ, AHY08LZ, AHY12LZ, AHY14LZ Installation Manual

0 (0)

ROOM AIR CONDITIONER

SAFETY INFORMATION . . . . . . . . .3

OPERATING INSTRUCTIONS. . . .5

CARE AND CLEANING . . . . . . . . . . .7

INSTALLATION INSTRUCTIONS. .8

TROUBLESHOOTING TIPS. . . . . . 13

WIFI SETUP . . . . . . . . . . . . . . . . . . . . . . 14

LIMITED WARRANTY . . . . . . . . . . . 17

CONSUMER SUPPORT . . . . . . . . . . 18

Before you begin

Record the GE module number and password for wifi setup. To locate this information, see page 14.

GE Module Number #____________

Password #____________________

Write the model and serial numbers here:

Model #_________________

Serial # _________________

You can find the rating label on the side of the air conditioner.

OWNER’S MANUAL &

INSTALLATION

INSTRUCTIONS

AHY08

AHY10

AHY12

AHY14

ENGLISH/ESPAÑOL

GE is a trademark of the General Electric Company. Manufactured under trademark license.

49-5000469 Rev. 0 01-20 GEA

THANK YOU FOR MAKING GE APPLIANCES A PART OF YOUR HOME.

Whether you grew up with GE Appliances, or this is your first, we’re happy to have you in the family.

We take pride in the craftsmanship, innovation and design that goes into every GE Appliances product, and we think you will too. Among other things, registration of your appliance ensures that we can deliver important product information and warranty details when you need them.

Register your GE appliance now online. Helpful websites and phone numbers are available in the Consumer Support section of this Owner’s Manual. You may also mail in the pre-printed registration card included in the packing material.

2

 

49-5000469 Rev. 0

 

IMPORTANT SAFETY INFORMATION

READ ALL INSTRUCTIONS BEFORE USING THE APPLIANCE

WARNING For your safety, the information in this manual must be followed to minimize the risk of fire, electric shock or personal injury.

Ŷ 8VH WKLV DSSOLDQFH RQO\ IRU LWV LQWHQGHG SXUSRVH DV described in this Owner’s Manual.

Ŷ This air conditioner must be properly installed in accordance with the Installation Instructions before it is used.

Ŷ Never unplug your air conditioner by pulling on the power cord. Always grip plug firmly and pull straight out from the receptacle.

Ŷ Replace immediately all electric service cords that have become frayed or otherwise damaged. A damaged power supply cord must be replaced with a new power supply cord obtained from the manufacturer and not repaired. Do not use a cord that shows cracks or abrasion damage along its length or at either the plug or connector end.

Ŷ Turn the unit OFF and unplug your air conditioner before cleaning.

Ŷ For your safety…do not store or use combustible materials, gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance.

Ŷ If the receptacle does not match the plug, the receptacle must be changed out by a qualified electrician.

 

 

 

 

 

Risk of Fire or Explosion. This unit contains flammable refrigerant.

 

 

 

WARNING

 

 

 

 

 

Additional safety precautions must be followed.

 

 

 

 

 

Ŷ Do not drill holes in the unit.

Ŷ 'R QRW XVH PHDQV WR DFFHOHUDWH WKH GHIURVWLQJ SURFHVV

or to clean, other than those recommended by the

Ŷ Maintenance, cleaning, and service should only be

manufacturer.

 

 

performed by technicians properly trained and qualified

 

 

 

 

 

 

Ŷ The appliance shall be stored in a room without

in the use of flammable refrigerants.

continuously operating ignition sources (for example:

Ŷ GE Appliances does not support any servicing of the

open flames, an operating gas appliance or an

air conditioner.

operating electric heater.

 

 

Ŷ Dispose of air conditioner in accordance with Federal

Ŷ Do not pierce or burn refrigerant tubing. Be aware that

refrigerants may not contain an odor.

and Local Regulations. Flammable refrigerants require

special disposal procedures. Contact your local

 

 

 

 

 

 

Ŷ Keep ventilation openings clear of obstruction.

authorities for the environmentally safe disposal of your

Ŷ When handling, installing, and operating the appliance,

air conditioner.

 

care should be taken to avoid damage to the refrigerant tubing.

INFORMATION SAFETY

READ AND SAVE THESE INSTRUCTIONS

49-5000469 Rev. 0

3

SAFETY INFORMATION

IMPORTANT SAFETY INFORMATION

READ ALL INSTRUCTIONS BEFORE USING THE APPLIANCE

WARNING USE OF EXTENSION CORDS

RISK OF FIRE. Could cause serious injury or death.

Ŷ '2 127 XVH VXUJH SURWHFWRUV RU PXOWL RXWOHW DGDSWRUV

Ŷ '2 127 XVH DQ H[WHQVLRQ FRUG ZLWK WKLV :LQGRZ $LU

with this Window Air Conditioner.

 

Conditioner.

 

 

 

HOW TO CONNECT ELECTRICITY

 

Do not, under any circumstances, cut or remove the third (ground) prong from the power cord. For personal safety, this appliance must be properly grounded.

DO NOT use an adapter plug with this appliance.

The power cord of this appliance is equipped with a 3-prong (grounding) plug which mates with a standard 3-prong (grounding) wall outlet to minimize the possibility of electric shock hazard from this appliance.

Power cord includes a current interrupter device. A test and reset button is provided on the plug case. The device should be tested on a periodic basis by first pressing the TEST button and then the RESET button while plugged into the outlet. If the TEST button does not trip or if the RESET button will not stay engaged, discontinue use of the air conditioner and contact a qualified service technician.

Have the wall outlet and circuit checked by a qualified electrician to make sure the outlet is properly grounded.

Where a 2-prong wall outlet is encountered, it is your personal responsibility and obligation to have it replaced with a properly grounded 3-prong wall outlet.

The air conditioner should always be plugged into its own individual electrical outlet which has a voltage rating that matches the rating plate.

This provides the best performance and also prevents overloading house wiring circuits which could cause a fire hazard from overheated wires.

See the Installation Instructions, Electrical Requirements section for specific electrical connection requirements.

WARNING Chemical Burn Hazard. Keep batteries away from children.

Ŷ 7KLV SURGXFW FRQWDLQV D OLWKLXP EXWWRQ FRLQ FHOO EDWWHU\

Ŷ If you think batteries might have been swallowed or

,I D QHZ RU XVHG OLWKLXP EXWWRQ FRLQ FHOO EDWWHU\ LV

placed inside any part of the body, seek immediate

swallowed or enters the body, it can cause severe

medical attention.

internal burns and can lead to death in as little

Ŷ 7KH FHOOV VKDOO EH GLVSRVHG RI SURSHUO\ LQFOXGLQJ

as 2 hours. Always completely secure the battery

keeping them away from children.

compartment. If the battery compartment does not

Ŷ Even used cells may cause injury.

close securely, stop using the product, remove the

batteries, and keep it away from children.

 

READ AND SAVE THESE INSTRUCTIONS

4

49-5000469 Rev. 0

Controls

Features and appearance will vary.

Lights beside the touch pads on the air conditioner control panel indicate the selected settings.

1

2

3

4

 

 

8

7

 

 

 

Mode

Cool

Fan Eco

Filter

Sleep

 

 

 

Speed

Auto

Med High

WiFi

 

1

4

5

6

+

3 -

ON/OFF

MODE

SPEED

DELAY

TEMP/TIME

TEMP/TIME

5

9

Solid light indicates WiFi

 

 

connected

Air Conditioner Controls

connecting

 

 

Blinking light indicates

 

 

See Appliance Communication

Remote Control

 

section in this manual

1. Power Pad

Turns air conditioner on and off. When turned on, the display will show the room temperature.

2. Display

Shows the room temperature or time remaining on the Delay timer. Shows the Set temperature while setting the temperature in Cool or Eco modes.

3. Temp and Delay Increase + /Decrease - Pads

8VH WR VHW WHPSHUDWXUH RU GHOD\ WLPH 7HPSHUDWXUH FDQ be set in Cool and Eco mode.

4. Mode Pad

8VH WR VHW WKH DLU FRQGLWLRQHU WR Fan Only, Cool, or

Eco mode.

5. Fan Speed Pad

In Cool or Eco PRGH 8VH WR VHW WKH IDQ VSHHG WR

Auto, High, Med or Low on the unit.

In Fan Only PRGH 8VH WR VHW WKH IDQ VSHHG WR High, Med, or Low on the unit.

6. Delay Pad (set by remote control only)

Delay ON—When the air conditioner is off, it can be set to automatically come on in 1 to 24 hours at its previous mode and fan settings.

Delay OFF—When the air conditioner is on, it can be set to automatically turn off in 1 to 24 hours.

How to set:

Press the Delay pad on the remote control. Each touch of the Increase + / Decrease - pads on the remote control will set the timer in 1-hour intervals.

To review the remaining time on the Delay timer, press the Delay SDG RQ WKH UHPRWH FRQWURO 8VH WKH Increase

+ / Decrease - pads on the remote control to set a new time if desired.

To cancel the timer, press Decrease pad on the remote control until the set time is zero.

7. Sleep Pad (set by air conditioner controls only)

The SLEEP mode sets the unit to gradually change settings over an 8 hour period to allow for some increased energy efficiency during sleep hours.

The SLEEP mode is available only in COOL and FAN only settings.

Press the SLEEP mode pad and its light will illuminate. The fan indicator will stay at the same setting but the air conditioner will automatically change the FAN speed to low in either COOL or FAN only mode.

In FAN only mode, the fan will stay in the LOW speed setting for 8 hours. After 8 hours, the air conditioner will resume the settings that were in place before the SLEEP mode pad was pressed.

In COOL mode, the fan will stay in the LOW speed setting for 8 hours from the time the SLEEP mode pad was pressed. The air conditioner will also raise the set point 2°F in 30 minutes and 2°F more in another 30 minutes where it will remain for the next 7 hours. After 8 hours, the air conditioner will resume the settings that were in place before the SLEEP mode pad was pressed.

While the unit is in SLEEP mode, pressing any pad will return it to the settings that were in place before the SLEEP mode pad was pressed.

8. Filter Reset Pad

This feature automatically notifies you that the air filter must be cleaned. The indicator light will come on after 250 hours of operation. Clean the air filter (refer to page 6), place it back in the front panel, and press the Filter Reset pad. The light will go off.

9. WiFi Connect Pad

Enables connection of the air conditioner to the home WiFi. Download App for details at:

www.GEAppliances.com/connect.

Controls CONDITIONER: AIR THE USING

49-5000469 Rev. 0

5

USING THE AIR CONDITIONER

Using the Air Conditioner

Do Not Operate in Freezing Outdoor Conditions

This cool-only air conditioner was not designed for freezing

It must not be used when the outdoor temperature is below

outdoor conditions.

freezing (32°F).

Control Panel Lights On/Off Feature

7KLV DLU FRQGLWLRQHU KDV D FRQWURO SDQHO OLJKWV RQ RII

To turn this feature off, press and hold the SLEEP pad,

feature where its lights will turn off when there is no

on the unit, for 5 seconds. The unit will beep to signal

activity with the controls for over one minute. To wake

the successful toggle of the feature on and off.

up the controls, press any pad on the controls and the

 

lights will come on to show the previous settings.

 

Remote Control

Ŷ To ensure proper operation, aim the remote control at the

Ŷ Make sure nothing is between the air conditioner and the

signal receiver on the air conditioner.

remote control that could block the signal.

Ŷ The remote control signal has a range of up to 20 feet.

Ŷ Make sure batteries are fresh and installed correctly as

 

indicated on the remote control.

Cool Mode

8VH WKH &RRO PRGH DW Low, Med, High or Speed for

FRROLQJ 8VH WKH Temperature Increase + Decrease - pads to set the desired temperature between 64°F and 86°F in 1°F increments.

An electronic thermostat is used to maintain the room temperature. The compressor will cycle on and off

to keep the room at the set level of comfort. Set the thermostat at a lower number and the indoor air will become cooler. Set the thermostat at a higher number and the indoor air will become warmer.

NOTE: If the air conditioner is off and is then turned on while set to a Cool setting or if turned from a fan setting to a Cool setting, it may take approximately 3 minutes for the compressor to start and cooling to begin.

Cooling Descriptions

For Normal Cooling—Select the Cool mode and

High or Med fan with a middle set temperature.

For Maximum Cooling—Select the Cool mode and High fan with a lower set temperature.

For Quieter and Nighttime Cooling—Select the

Cool mode and Low fan with a middle set temperature.

Eco Mode

Controls the fan.

ON—The fan will cycle on and off with the compressor. This may result in wider variations of room temperature and humidity. NOTE: the fan may continue to run

for a short time or may pulse intermittently after the compressor cycles off to sample the room air.

OFF—The fan runs all the time, while the compressor cycles on and off.

Fan Only Mode

8VH WKH )DQ 2QO\ 0RGH DW /RZ 0HG RU +LJK IDQ VSHHG to provide air circulation and filtering without cooling. Since fan-only settings do not provide cooling, a Set temperature cannot be entered. The room temperature will appear in the display.

Auto Fan Mode

Set to Auto for the fan speed to automatically set to the

If the room needs more cooling, the fan speed will

speed needed to provide optimum comfort settings with

automatically increase. If the room needs less cooling,

the set temperature.

the fan speed will automatically decrease.

6

49-5000469 Rev. 0

Using the Air Conditioner

Air Direction

8VH WKH OHYHUV WR DGMXVW WKH DLU GLUHFWLRQ OHIW RU ULJKW

Tilt the louver bank to adjust up and down.

Care and Cleaning

 

Grille and Case

 

Turn the air conditioner off and remove the plug from the

To clean, use water and a mild detergent. Do not use

wall outlet before cleaning.

bleach or abrasives.

Air Filter

The air filter behind the front grille should be checked and cleaned at least every 30 days or more often if necessary.

To remove:

Open the inlet grille by pulling downward on the tabs at the top upper corners of the inlet grille until the grille is in a 45º position. Remove the filter.

Clean the filter with warm, soapy water. Rinse and let the filter dry before replacing it. Do not clean the filter in a dishwasher.

CAUTION DO NOT operate the air conditioner without a filter because dirt and lint will clog it and reduce performance.

Outdoor Coils

The coils on the outdoor side of the air conditioner should be checked regularly. If they are clogged with dirt or soot, they may be professionally cleaned.

CLEANING AND CONDITIONER/CARE AIR THE USING

How to Insert the Battery in the Remote Control

1.Remove the screw on the back of the battery cover.

2.Pinch the slide lock and pull the battery tray out at the same time.

3.Insert new battery, making sure that the (+) and (–) of battery are installed correctly.

4.Reinsert the battery tray and reinstall the screw.

NOTES:

Ŷ 8VH RQH &5 9 /LWKLXP EDWWHU\

Ŷ Remove the battery from the remote control if the system is not going to be used for a long time.

49-5000469 Rev. 0

7

INSTALLATION INSTRUCTIONS

Installation Instructions

Questions? Call 800.GE.CARES (800.432.2737) or Visit our Website at: GEAppliances.com

BEFORE YOU BEGIN

Read these instructions completely and carefully.

IMPORTANT – Save these

instructions for local inspector’s use.

IMPORTANT – Observe all

governing codes and ordinances.

Note to Installer – Be sure to leave these instructions with the Consumer.

Note to Consumer – Keep these instructions for future reference.

Skill level – Installation of this appliance requires basic mechanical skills.

Completion time – Approximately 1 hour

We recommend that two people install

this product.

Proper installation is the responsibility of the installer.

Product failure due to improper installation is not covered under the Warranty.

<RX 0867 XVH DOO VXSSOLHG SDUWV DQG XVH SURSHU installation procedures as described in these instructions when installing this air conditioner.

ELECTRICAL

REQUIREMENTS

7KHVH PRGHOV UHTXLUH D YROW $&

60-Hz grounded outlet protected with a 15-amp time-delay fuse or circuit breaker.

The 3-prong grounding plug minimizes the possibility of electric shock hazard. If the wall outlet you plan to use is only a 2-prong outlet, it is your responsibility to have it replaced with a properly grounded 3-prong wall outlet.

CAUTION

Do not, under any circumstances, cut or remove the third (ground) prong from the power cord.

Do not change the plug on the power cord of this air conditioner.

Aluminum house wiring may present special problems—consult a qualified electrician.

ELECTRICAL

REQUIREMENTS (cont)

Power cord includes a current interrupter device. A test and reset button is provided on the plug case. The device should be tested on a periodic basis by first pressing the TEST button and then the RESET button while plugged into the outlet. If the TEST button does not trip or if the RESET button will not stay engaged, discontinue use of the air

conditioner and contact a qualified service technician.

TOOLS YOU WILL NEED

Phillips head screwdriver

'ULOO DQG ´ GULOO ELW

Pencil

 

Ruler or tape measure

 

 

 

Level

 

Scissors or knife

 

 

 

8

49-5000469 Rev. 0

Installation Instructions

 

 

 

INSTALLATION

PARTS INCLUDED

Side

 

Side Curtain

 

Foam top window

 

 

 

(Appearance may vary)

gasket

 

Frame

Right

 

 

 

 

Left

 

Top mounting rail

 

 

 

 

 

 

Curtain (2)

 

 

 

INSTRUCTIONS

Air

Remote

 

 

 

conditioner

ON/OFF

 

 

 

 

Control

MODE

 

 

 

 

 

SPEED

 

 

 

 

 

DELAY

 

 

 

 

 

+ TEMP/TIME

 

 

 

 

 

- TEMP/TIME

Bottom Seal and

 

 

 

 

 

Side Seals (3)

 

 

 

Side Curtain

 

 

 

 

 

Foam (2)

 

 

 

 

$+<$+<$+< 7\SH$

Side Brackets (2)

Window locking

 

 

AHY08: Type A (3)

Type B (9)

 

bracket (1)

 

 

 

 

 

 

49-5000469 Rev. 0

 

 

 

 

9

GE AHY10LZ, AHY08LZ, AHY12LZ, AHY14LZ Installation Manual

INSTALLATION INSTRUCTIONS

Installation Instructions

1.WINDOW REQUIREMENTS

These instructions are for a standard double-hung window. You will need to modify them for other types of windows.

The air conditioner can be installed without the

side curtain panels if needed to fit in a narrow window. See the window opening dimensions.

• All supporting parts must be secured to firm wood, masonry or metal.

• The electrical outlet must be within reach of the power cord.

• Follow the dimensions in the table and illustration for your model.

Models

A

B

AHY08

´ PLQ

´ ´

$+<$+<

´ PLQ

´ ´

AHY14

´

´ ´

A

B

(With side curtain panels)

2. STORM WINDOW REQUIREMENTS

A storm window frame will not allow the air conditioner to tilt toward the outside, and will keep it from draining properly. To adjust for this, attach a piece of wood to the sill.

WOOD PIECES WIDTH: 2Ǝ

LENGTH: Long enough to fit inside the window frame.

THICKNESS: To determine the thickness, place

D SLHFH RI ZRRG RQ WKH VLOO WR PDNH LW Ǝ KLJKHU than the top of the storm window frame or the

vinyl frame.

Attach securely with nails or screws provided by the installer.

Ǝ KLJKHU

than storm

window

frame

Storm window

frame

Ǝ KLJKHU than vinyl frame (on some windows)

Wood

Sill

9LQ\O IUDPH

3.PREPARE THE AIR CONDITIONER

A.Install the top mounting rail with 4 Type A

VFUHZV $+< $+< $+< RU 7\SH $ screws (AHY08) from the outside of the case.

Top Mounting rail

Bottom

mounting

rail

B. Apply the weather seals provided to the bottom, top and sides of the window to the seal around the perimeter of the air conditioner.

Cut and apply

 

weather strip to

 

front and bottom

 

edge of window

Cut and apply

frame.

a weather strip

Cut and apply

to side of the

curtain frame

weather strip to

(one on each

back edge of

side).

the window sill.

 

C. Slide the side curtain panels into the side panel rails.

D. Slide left and right side curtain frames into top and bottom rails. Make sure that side curtains snap into side of the frames.

Snap curtain into frame

10

49-5000469 Rev. 0

Installation Instructions

4.INSTALL THE AIR CONDITIONER IN THE WINDOW

A.Mark the center of the window. Set the air conditioner in the window so that is it centered. Place the air conditioner so that front edge of the bottom mounting rail is against the back edge of the sill.

B.Bring the window down so that the front edge of the top mounting is in front of the window. Make sure that the air conditioner is level or tilting slightly to the outside.

C. Extend the curtain panels until they fill the window. Mark the location of the holes in each

FRUQHU 8VH WKH GULOO DQG ´ GULOO ELW WR GULOO SLORW

KROHV 8VH W\SH % VFUHZV WR VHFXUH WKH VLGH panels in place.

5.SECURE AIR CONDITIONER

A.Loosen the screw on the right hand side of the air conditioner near the bottom.

B.Slide a side bracket over the screw so that the bracket is resting on the window sill. Tighten the screw.

C. 8VH D ´ GULOO ELW WR GULOO D VWDUWHU KROH LQWR WKH window sill through the holes in the side bracket.

8VH W\SH % VFUHZV WR DWWDFK WKH VLGH EUDFNHW WR the window sill.

D.Repeat the side bracket installation on the left side.

E.Measure and cut adhesive foam backed sheet. Apply over side curtain and frame.

Side curtain foam

Type B screws

Weather seals

INSTRUCTIONS INSTALLATION

49-5000469 Rev. 0

11

Loading...