GE AJCQ06LCG, AJCM10DCG, AJCQ08ACG Maintance Manual

0 (0)

Air Conditioners

Room

Safety Instructions . . . . . . . . . 2, 3

About the Controls . . . . . . . . . . 4-9

Cool Models. . . . . . . . . . . . . . . . . . . . . 4, 5

Heat Models . . . . . . . . . . . . . . . . . . . . . 6, 7

Vent Control. . . . . . . . . . . . . . . . . . . . . . . . 8

Care and Cleaning

Grille and Case. . . . . . . . . . . . . . . . . . . 10

Outdoor Coils . . . . . . . . . . . . . . . . . . . . 10

Front Grille . . . . . . . . . . . . . . . . . . . . . . . . 10

Air Filter . . . . . . . . . . . . . . . . . . . . . . . 10-11

Long Term Storage . . . . . . . . . . . . . . 12

Installation Instructions

Before You Begin. . . . . . . . . . . . . . .12-13

Installing a J-Model in

an Existing Wall Case . . . . . . . . . . . . . 14

Through-the-Wall

Installation . . . . . . . . . . . . . . . . . . . . . . . 15

Troubleshooting Tips . . . . . . . 16

Normal Operating Sounds . . . . . . . 16

Consumer Support

Warranty. . . . . . . . . . . . . . . . . . . . . . . . . 19

Consumer Support. . . . . . Back Cover

Write the model and serial numbers here:

Model # _________________________

Serial # ____________________________

Find these numbers on a label on the front of the base pan behind the front grille.

Owner’s Manual and

Installation Instructions

Cool Only:

AJCM 08,

10

ACG

 

AJCM 10,

12

DCG

 

AJCQ

06

 

LCG

 

AJCQ

08, 10, 12

ACG

 

AJCQ

09, 10, 12

DCG

 

 

 

 

 

Heat/Cool:

AJEM

12

 

DCF

 

AJEQ

06

 

LCF

 

AJEQ

08

 

ACF

 

AJEQ

09, 10, 12

DCF

Español

For a Spanish version of this manual, visit our Website at GEAppliances.com.

Para consultar una version en español de este manual de instrucciones, visite nuestro sitio de internet GEAppliances.com.

Française

For a French version of this manual, visit our Website at GEAppliances.com.

Pour une version française de ce manuel d’utilisation, veuillez visiter notre site web à l’adresse GEAppliances.com.

49-7754 02-16 GE

IMPORTANT SAFETY INFORMATION.

READ ALL INSTRUCTIONS BEFORE USING.

SAFETY INFORMATION

This is the safety alert symbol. This symbol alerts you to potential hazards that can kill or hurt you and others. All safety messages will follow the safety alert symbol and the word “DANGER”, “WARNING”, or “CAUTION”. These words are defined as:

 

DANGER

Indicates a hazardous situation which, if not avoided, will result in death or serious injury.

 

 

 

 

 

WARNING

Indicates a hazardous situation which, if not avoided, could result in death or serious injury.

 

 

 

 

CAUTION

Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.

 

 

 

 

 

 

WARNING

For your safety, the information in this manual must be followed to minimize the risk of fire or explosion, electric shock, or to prevent property damage, personal injury, or loss of life.

SAFETY PRECAUTIONS

WARNING

Risk of electric shock. Can cause injury or death. For your safety, the information in this manual must be followed to minimize the risk of fire, electric shock or personal injury.

Use this appliance only for its intended purpose as described in this Owner’s Manual.

This air conditioner must be properly installed in accordance with the Installation Instructions before it is used.

Never unplug your air conditioner by pulling on the power cord. Always grip plug firmly and pull straight out from the receptacle.

Replace immediately all electric service cords that have become frayed or otherwise damaged. A damaged power supply cord must be replaced with a new power supply cord obtained from the manufacturer and not repaired. Do not use a cord that shows cracks or abrasion damage along its length or at either the plug or connector end.

Turn OFF and unplug your air conditioner before making any repairs or cleaning.

NOTE: We strongly recommend that any servicing be performed by a qualified individual.

For your safety…do not store or use combustible materials, gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance.

All air conditioners contain refrigerants, which under federal law must be removed prior to product disposal. If you are getting rid of an old product with refrigerants, check with the company handling disposal about what to do.

SAVE THESE INSTRUCTIONS

2

IMPORTANT SAFETY INFORMATION. READ ALL INSTRUCTIONS BEFORE USING.

WARNING

HOW TO CONNECT ELECTRICITY

WARNING Risk of electric shock. Can cause injury or death. This appliance must be properly grounded. Do not, under any circumstances, cut or remove the third (ground) prong from the power cord. For personal safety, this appliance must be properly grounded.

The power cord of this appliance is equipped with a 3-prong (grounding) plug which mates with a

standard 3-prong (grounding) wall outlet to minimize the possibility of electric shock hazard from this appliance.

Have the wall outlet and circuit checked by a qualified electrician to make sure the outlet is properly grounded.

Power cord may include a current interrupter device. A test and reset button is provided on the plug case. The device should be tested on a periodic basis by first pressing the TEST button and then the

RESET button. If the TEST button does not trip or if the RESET button will not stay engaged, discontinue use of the air conditioner and contact a qualified service technician.

Where a 2-prong wall outlet is encountered, it is your personal responsibility and obligation to have it replaced with a properly grounded 3-prong wall outlet.

WARNING

Risk of electric shock. Can cause injury or death.

The air conditioner should always be plugged into its own individual electrical outlet which has a voltage rating that matches the rating plate. This provides the best performance and also prevents overloading house wiring circuits which could cause a fire hazard from overheated wires.

See the Installation Instructions, Electrical Requirements section for specific electrical connection requirements.

USE OF EXTENSION CORDS

 

 

 

DO NOT use an extension cord with this Built-in Air

WARNING

 

RISK OF FIRE. Could cause

 

Conditioner.

serious injury or death.

 

 

DO NOT use surge protectors or multi-outlet adaptors

 

 

 

with this Built-in Air Conditioner.

USE OF ADAPTER PLUGS

 

 

WARNING

Risk of electric shock. Can cause injury or death.

We strongly recommend against the use of an adapter plug.

If you must use an adapter, where local codes permit, a temporary connection may be made to a properly grounded 2-prong wall outlet by use of a UL-listed adapter available at most local hardware stores.

The larger slot in the adapter must be aligned with the larger slot in the wall outlet to provide proper polarity in the connection of the power cord.

When disconnecting the power cord from the adapter, always hold the adapter in place with one hand while pulling the power cord plug with the other hand. If this is not done, the adapter ground terminal is very likely to break with repeated use.

If the adapter ground terminal breaks, DO NOT USE the air conditioner until a proper ground has been established.

Attaching the adapter ground terminal to a wall outlet cover screw does not ground the appliance unless the cover screw is metal, not insulated, and the wall outlet is grounded through the house wiring. You should have the circuit checked by a qualified electrician to make sure the outlet is properly grounded.

READ AND FOLLOW THIS SAFETY INFORMATION CAREFULLY.

SAVE THESE INSTRUCTIONS

3

$ERXW WKH FRQWUROV RQ WKH DLU FRQGLWLRQHU³&RRO 2QO\ 0RGHOV

Appearance may vary.

 

 

 

 

 

 

 

 

 

 

Cool

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fan

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Hi

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Mode

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

On

 

 

 

 

 

 

Med

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Low

 

 

 

 

 

Off

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Delay Hrs

 

 

 

Temp

 

 

 

 

Reset

Power

 

On Off

 

 

 

 

 

Filter

 

 

 

 

On/Off

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Power

Cool Fan

Mode

Temp High

Med

On

Delay

Hrs Low

Off

Air Conditioner Controls

Remote Control

Controls

Lights beside the touch pads on the air conditioner control panel indicate the selected settings.

1. Power On/Off

Turns air conditioner on and off.

2.Display

Displays the temperature setting. Displays hours when setting the timer.

3. Mode

On the remote control, use to set the air conditioner to

Cool or Fan mode.

On the air conditioner controls, use to set Cool or Fan mode at High, Med or Low fan speed. Indicator lights on the air conditioner controls will show the mode and fan speed selected.

4.Temp Increase + /Decrease – Pads

Use to set temperature when in COOL mode.

5.Fan Speeds

Use to set the fan speed at Low, Med or High.

6.Delay Hrs

2Q³When the air conditioner is off, it can be set to automatically turn on in half an hour to 24 hours at its previous setting. Each touch will set the time in half hours up to 10 and then in hours up to 24.

To cancel the Delay Timer, press the On pad until “CL” appears. Then wait until the display turns off.

2II³When the air conditioner is on, it can be set to automatically turn off in half an hour to 24 hours. Each touch will set the time in half hours up to 10 and then in hours up to 24.

To cancel the Delay Timer, press the Off pad until “CL” appears and wait for the set temperature to be displayed. The unit will now resume normal operation.

7.Reset Filter

LED will turn on when fan has accumulated 250 hours of run time as a reminder to clean filter. Press Reset Filter to turn off the LED and reset the accumulated run time.

8.Remote Control Signal Receiver

NOTE: When the air conditioner is turned on, it will automatically start in the setting last used.

Remote Control

To ensure proper operation, aim the remote control at the signal receiver on the air conditioner.

The remote control signal has a range of up to 21 feet.

Make sure nothing is between the air conditioner and the remote control that could block the signal.

0DNH VXUH EDWWHULHV DUH IUHVK DQG LQVWDOOHG FRUUHFWO\³VHH the Care and Cleaning section.

4

Cool Mode

Remote Control

1.Press Cool pad.

2.Press Low, Med or High pads to set desired fan speed.

3. Press the Increase +/ Decrease – pads to set the desired temperature 60°F to 85°F in 1°F increments.

Control Panel

1.Press the Mode pad until the Cool indicator light is lit and the Low, Med or High indicator light is lit for the desired fan speed.

2.Press the Increase + / Decrease – pads to set the desired temperature 60°F to 85°F in 1°F increments.

A thermostat is used to maintain the room temperature. The compressor will cycle on and off to keep the room at the set level of comfort. Set the thermostat at a lower number and the indoor air will become cooler.

Set the thermostat at a higher number and the indoor air will become warmer.

NOTE: If the air conditioner is off and is then turned on while set to Cool, it will take approximately 3 minutes for the compressor to start and cooling to begin.

Cooling Descriptions

)RU1RUPDO&RROLQJ³Select the Cool mode and High or Med fan with a middle set temperature.

)RU0D[LPXP&RROLQJ³Select the Cool mode and HIGH fan with a lower set temperature.

)RU4XLHWHUDQG1LJKWWLPH&RROLQJ³Select the Cool mode and Low fan with a middle set temperature.

NOTE: If you switch from a Cool setting to Off or to a fan setting, wait at least 3 minutes before switching back to a Cool setting.

FAN MODE

Use the Fan mode to provide air circulation and filtering without cooling. Since fan-only settings do not provide cooling, a temperature setting will not be displayed.

Remote Control

Press Fan pad. Press Low, Med or High pads to set desired fan speed.

Control Panel

Press the Mode pad until the Fan indicator light is lit and the Low, Med or High indicator light is lit for the desired fan speed.

5

$ERXW WKH FRQWUROV RQ WKH DLU FRQGLWLRQHU³+HDW &RRO 0RGHOV

Appearance may vary.

 

Cool

Mode

 

Fan

On

 

Heat

 

 

Off

 

Hi

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Low

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Timer

 

 

Temp

 

 

 

 

 

 

 

On Off

Fan

 

 

 

 

Power

 

 

 

 

 

 

 

 

 

 

On/Off

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Air Conditioner Controls

Remote Control

Lights beside the touch pads on the air conditioner

control panel indicate the selected settings.

Controls

1. ON/OFF

Turns air conditioner on and off.

2.Display

Displays the temperature setting. Displays hours when setting the timer.

3. MODE

On the air conditioner controls, use to set COOL, HEAT or FAN mode. Indicator lights on the air conditioner controls will show the mode selected.

4.TEMP Increase + /Decrease – Pads

Use to set temperature when in COOL or HEAT mode.

5.FAN Speeds

Use to set the fan speed at LOW or HIGH. Indicator lights will show the speed selected.

6.TIMER

21³When the air conditioner is off, it can be set to automatically turn on in half an hour to 24 hours at its previous setting. Each touch will set the time in half hours up to 10 and then in hours up to 24.

To cancel the On Timer, press the ON pad until “CL” appears. Then wait until the display turns off.

2))³When the air conditioner is on, it can be set to automatically turn off in half an hour to 24 hours. Each touch will set the time in half hours up to 10 and then in hours up to 24.

To cancel the Off Timer, press the OFF pad until “CL” appears and wait for the set temperature to be displayed. The unit will now resume normal operation.

7.Remote Control Signal Receiver

NOTE: When the air conditioner is turned on, it will automatically start in the setting last used.

Remote Control

To ensure proper operation, aim the remote control at the signal receiver on the air conditioner.

The remote control signal has a range of up to 21 feet.

Make sure nothing is between the air conditioner and the remote control that could block the signal.

0DNH VXUH EDWWHULHV DUH IUHVK DQG LQVWDOOHG FRUUHFWO\³VHH the Care and Cleaning section.

6

COOL MODE

Remote Control

1.Press COOL pad.

2.Press LOW or HIGH pads to set desired fan speed.

3.Press the ,1&5($6( '(&5($6(²pads to set the desired temperature 60°F to 85°F in 1°F increments.

Control Panel

1.Press the MODE pad until the COOL indicator light is lit.

2.Press the FAN pad until HIGH or LOW indicator light is lit for desired fan speed.

3.Press the ,1&5($6( '(&5($6(²pads to set the desired temperature 60°F to 85°F in 1°F increments.

A thermostat is used to maintain the room temperature. The compressor will cycle on and off to keep the room at the set level of comfort. Set the thermostat at a lower number and the indoor air will become cooler.

Set the thermostat at a higher number and the indoor air will become warmer.

NOTE: If the air conditioner is off and is then turned on while set to COOL, it will take approximately 3 minutes for the compressor to start and cooling to begin.

Cooling Descriptions

)RU1RUPDO&RROLQJ³Select the COOL mode and HIGH fan with a middle set temperature.

)RU0D[LPXP&RROLQJ³Select the COOL mode and HIGH fan with a lower set temperature.

)RU4XLHWHUDQG1LJKWWLPH&RROLQJ³Select the COOL mode and LOW fan with a middle set temperature.

NOTE: There will be a 3-minute delay between setting changes such as COOL to OFF and back to COOL.

HEAT MODE

Remote Control

1.Press HEAT pad.

2.Press LOW or HIGH pads to set desired fan speed.

3.Press the ,1&5($6( '(&5($6(²pads to set the desired temperature 60°F to 85°F in 1°F increments.

Control Panel

1.Press the MODE pad until the HEAT indicator light is lit.

2.Press the FAN pad until HIGH or LOW indicator light is lit for desired fan speed.

3.Press the ,1&5($6( '(&5($6(²pads to set the desired temperature 60°F to 85°F in 1°F increments.

A thermostat is used to maintain the room temperature. The heater will cycle on and off to keep the room at the set level of comfort. Set the thermostat at a higher number and the indoor air will become warmer.

Set the thermostat at a lower number and the indoor air will become cooler.

NOTE: If the air conditioner is off and is then turned on while set to HEAT, it will take approximately 1 minute for the heater to start and heating to begin.

Heating Descriptions

)RU1RUPDO+HDWLQJ³Select the Heat mode and HIGH fan with a middle set temperature.

)RU0D[LPXP+HDWLQJ³Select the HEAT mode and HIGH fan with a higher set temperature.

)RU4XLHWHUDQG1LJKWWLPH+HDWLQJ³Select the HEAT mode and LOW fan with a middle set temperature.

FAN

Use the FAN to provide air circulation and filtering without cooling or heating. Since fan only settings do not provide cooling or heating, a temperature setting will not be displayed.

Remote Control

Press FAN pad. Press LOW or HIGH pads to set desired fan speed.

Control Panel

Press the MODE pad until the FAN indicator light is lit and the LOW or HIGH indicator light is lit for the desired fan speed.

7

About the controls on the air conditioner

Vent Control

The vent control is located behind the front grille on the right side of the air discharge area. When CLOSED, only the air inside the room will be circulated and conditioned. When OPEN, the vent allows outdoor fresh air exchange.

To open or close the vent:

1.Remove the front grille.

2.Remove the vent card screw.

3.Remove vent card, turn it over and replace it by locating rear hole in card over locating pin inside air discharge and reattaching screw at front.

The unit leaves the factory set at the CLOSE position.

Locating hole

Locating hole

Screw hole

Screw hole

OPEN position

CLOSE position

(Mesh end toward back)

(Mesh end toward front)

Air Direction

Horizontal louvers

on the front grille let you control the air direction up and down.

Cool Only Models

Auxiliary Controls – Dip Switches (location varies by model)

The auxiliary dip switch controls are located behind the

URRP FDELQHW³DV VKRZQ LQ WKLV ILJXUH

The owner is responsible for checking switches and ensuring they are in the desired position.

COOL

FAN

 

 

HIGH

MODE

ON

 

MED

OFF

 

 

 

TIMER

 

TEMP

 

ON OFF

SLEEP

- +

ON

OFF

Remove the front grille to adjust the vertical louvers side-to-side to direct the air left

or right.

Fan Cycle/Continuous - Cool

ON

Filter Reminder

Function

Fan Cycle/Continuous - Cool

When this switch is enabled (RIGHT), it allows the indoor fan to cycle on/off with the compressor. When this switch is disabled (LEFT), it allows the indoor fan to run continuously. The default setting is right (fan cycle).

Filter Reminder Funtion

When this switch is enabled (RIGHT), an LED will light up the user interface after 250 of accumulated fan run time. It serves as a reminder to clean the filter. When this switch is disabled (LEFT), the function is disabled. The default setting is right (enabled).

Heat/Cool Models

Auxiliary Controls – Dip Switches (location varies by model)

The auxiliary dip switch controls are located behind the

URRP FDELQHW³DV VKRZQ LQ WKLV ILJXUH

The owner is responsible for checking switches and ensuring they are in the desired position.

Fan Cycle/Continuous - Cool

ON

Filter Reminder Function

ON

Fan Cycle/Continuous - Cool

Fan Cycle/

Continuous - Heat

Class 2

No function (reserved for future use)

8

Fan Cycle/Continuous - Cool

When this switch is enabled (UP), it allows the indoor fan to cycle on/off with the compressor. When this switch is disabled (DOWN), it allows the indoor fan to run continuously. The default setting is DOWN (continuous).

Fan Cycle/Continuous - Cool

Fan Cycle/Continuous - Heat

When this switch is enabled (UP), it allows the indoor fan to cycle on/off with the heater operation. When this switch is disabled (DOWN), it allows the indoor fan to run continuously. The default setting is UP (cyclic).

Fan Cycle/Continuous - Heat

Class 2 - Remote Thermostat

When this switch is enabled (UP), it allows the unit to operate with

 

 

 

 

 

Class 2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

a Class 2 Remote Control Wall Thermostat. The unit controls are

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

disabled. The default setting is DOWN (disabled).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Terminal Connections Remote Thermostat - Class 2 (on some models)

 

 

 

 

 

 

 

 

 

The controls are located under a plastic cover behind the front grille.

1.Remove the front grille. See the Front Grille section of Care and Cleaning.

2.Remove the screws securing the plastic cover over the wiring connections. Set aside screws and plastic cover.

3.To make wiring connections, insert the wires into the bottom of the terminals and tighten screws securely.

4.After all desired connections have been made, replace the plastic cover and front grille.

The owner is responsible for making all connections and setting the appropriate dip switches.

When connected, the unit will be controlled by a remote thermostat.

NOTE: The number 3 dip switch must be in the enabled (UP) position to activate the remote thermostat. (See the installation instructions supplied with the remote thermostat.)

IMPORTANT:

The thermostat connections provide 24 V AC only.

If using a digital/electronic wall thermostat, ensure it is compatible with 24 VAC signal. See the Installation Instructions for the wall thermostat.

NOTICE:

Damage to a wall thermostat or to the electronics can result from improper connections. Special care must be used in connecting the wires. No line voltage connections should be made to any circuit. Isolate all wires in building from line voltage.

Terminal connections

location under front

grille

Red - 24 V AC only Green - Low Speed Fan

Green - High Speed Fan

No Function

(reserved for furture use)

Yellow - Compressor White - Heater

Common - Ground No Function

(reserved for furture use)

9

Care and cleaning of the air conditioner.

Grille and Case

Turn the air conditioner off and remove the plug from the wall outlet before cleaning.

To clean, use water and a mild detergent. Do not use bleach or abrasives.

Outdoor Coils

The coils on the outdoor side of the air conditioner should be checked regularly.

If they are clogged with dirt or soot they may be professionally steam cleaned, a service available through your GE service outlet.

Front Grille

The front grille can be removed for more thorough cleaning and to locate the model and serial numbers on the front of the base pan.

To remove:

1.Pull the filter out.

2.Remove the two grille screws.

On some models

On some models

3.Pull the grille out from the bottom and lift up from the tabs on the top of the case.

Grille

Tab

To replace:

Hook the tabs on the front grille even with the tabs on the case and snap into place.

Replace the screws and filter.

Grille

Tab

10

To maintain optimum performance, clean the filter at least every 30 days.

Air Filter

FRONT

FRONT

'LUW\ ILOWHU³1HHGV FOHDQLQJ

&ORJJHG ILOWHU³*UHDWO\

 

reduces cooling, heating

 

and airflow.

Turn the air conditioner off before cleaning.

The most important thing you can do to maintain the air conditioner is to clean the filter at least every 30 days. A clogged filter reduces cooling, heating and air flow.

Keeping the air filter clean will:

Decrease cost of operation.

Save energy.

Prevent clogged heat exchanger coils.

Reduce the risk of premature component failure.

To clean the air filters:

Vacuum off the heavy soil.

Run water through the filters.

Dry thoroughly before replacing.

To remove the air filter, on some models:

Carefully pull the tab forward, up and out.

To remove the air filter, on other models:

Pull it down.

To replace the air filter:

Replace the clean filter by pushing it back into place.

NOTICE:Do not operate the air conditioner without the filter in place. If a filter becomes torn or damaged it should be replaced immediately.

Operating without the filter in place or with a damaged filter will allow dirt and dust to reach the indoor coil and reduce the cooling, heating, airflow and efficiency of the unit.

Replacement filters are available from your salesperson, GE dealer, GE Service and Parts Center or authorized Customer Care® servicers.

11

Care and cleaning of the air conditioner.

How to Insert the Batteries in the Remote Control

1.Remove the battery cover by sliding it according to the arrow direction.

2.Insert new batteries making sure that the (+) and (–) of battery are installed correctly.

3.Reattach the cover by sliding it back into position.

NOTES:

Use 2 AAA (1.5 volt) batteries. Do not use rechargeable batteries.

Remove the batteries from the remote control if the system is not going to be used for a long time.

Do not mix old and new batteries. Do not mix alkaline, standard (carbon-zinc) or rechargeable (ni-cad, ni-mh, etc) batteries.

Long Term Storage

When the room air conditioner is not in use it is recommended that the unit be covered to eliminate drafts and limit energy loss.

Insulated covers that mount to the front of the unit, that are designed to eliminate drafts and energy loss are recommended. Approximate size of indoor cover should be 26 in * 16 in. * 7 in..

Unplug the unit before adding the cover. Follow cover manufacturer’s installation instruction to install cover.

Cover should be removed prior to running the unit.

12

Installation

Air Conditioner

Instructions

 

Questions? Call 800.GE.CARES (800.432.2737) or Visit our Website at: GEAppliances.com

BEFORE YOU BEGIN

Read these instructions completely and carefully.

IMPORTANT ³ 6DYH WKHVH LQVWUXFWLRQV for local inspector’s use.

IMPORTANT ³ 2EVHUYH DOO JRYHUQLQJ FRGHV and ordinances.

Note to Installer – Be sure to leave these instructions with the Consumer.

Note to Consumer – Keep these instructions for future reference.

Skill level – Installation of this appliance requires basic mechanical skills.

Completion time – Approximately 1 hour

We recommend that two people install this product.

Proper installation is the responsibility of the installer.

Product failure due to improper installation is not covered under the Warranty.

Air conditioner break-in period

NOTE – As with any mechanical device with moving parts, this unit will have a wear-in period. AFTER INSTALLATION, this unit should be operated for 48 hours to achieve optimum efficiency.

ELECTRICAL REQUIREMENTS

WARNING

Risk of electric shock. Can cause injury or death. This appliance must be properly grounded. Where a 2-prong wall outlet is encountered, it is your responsibility and obligation to have it replaced with a properly grounded 3-prong outlet.

Some models require a 115/120-volt a.c., 60-Hz grounded outlet protected with a 15-amp time delay fuse or circuit breaker.

The 3-prong grounding plug minimizes the possibility of electric shock hazard. If the wall outlet you plan to use is only a 2-prong outlet, it is your responsibility to have it replaced with a properly grounded 3-prong wall outlet.

Do not, under any circumstances, cut or remove the third (ground) prong from the power cord.

Do not change the plug on the power cord of this air conditioner.

Aluminum house wiring may present special

SUREOHPV³FRQVXOW D TXDOLILHG HOHFWULFLDQ

Some models require 230/208-volt a.c., protected with a time delay fuse or circuit breaker. These models should be installed on their own single branch circuit for best performance and to prevent overloading house or apartment wiring circuits, which could cause a possible fire hazard from overheating wires.

IMPORTANT!

GE strongly recommends the removal of the old wall case

DQGWKHLQVWDOODWLRQRIDQHZ*(:DOO&DVH ,I\RX'2127 use a GE Wall Case, you run the risk of poor performance or product failure. This is not covered under the terms of the GE warranty.

13

Installation Instructions

Read these instructions completely and carefully.

Power cord may include a current interrupter device.

If the TEST button does not trip or if the RESET button

A test and reset button is provided on the plug case.

will not stay engaged, discontinue use of the air

The device should be tested on a periodic basis by first

conditioner and contact a qualified service technician.

pressing the TEST button and then the RESET button.

 

 

 

722/6 <28 0$< 1(('

Phillips-head

 

 

screwdriver

Ruler or Tape Measure

Scissors or knife

Drill

 

 

Hand or Saber Saw

Pencil

Level

 

Adjustable Wrench

 

 

GE KIT NUMBERS

USE GE

 

 

.,7 180%(5

)25

'(6&5,37,21

RAB46A ,46,

Use these kits for all GE

Standard wall case for “J” model chassis. RAG13 stamped

47A, 47, 48A, models and other brands

aluminum exterior grille included. Remove the existing case

48B & 48

not listed

and replace.

RAK65A1

All GE Models

Kit for window installation.

RAK690

RAB36, 37, 38, 46, 47 or 48

If you attach a custom architectural outdoor grille, use this kit

 

(J-Chassis)

to ensure proper airflow.

RAG13

RAB36, 37, 38, 46, 47 or 48

Standard aluminum exterior grille (included with RAB46, 47, 48,

 

(J-Chassis)

RAB46A, 47A, 48A, and 48B wall cases).

RAG14E

RAB36, 37, 38, 46, 47 or 48

Architectural louvered exterior grille.

 

(J-Chassis)

 

 

 

 

$'$ &RPSOLDQFH

Operation by

A Remote Control device is shipped with GE Built-In Air Conditioners. When operated by Re-

Remote Control

mote Control GE Built-in ACs meet all federal ADA compliance requirements.

Operation at

GE Built In Air Conditioners intended to be operated at the control panel meet federal ADA

Control Panel

compliance requirements when installed so that the controls are more than 15” from ground

 

and less than 48” from the ground.

Operation by

GE Air Conditioners intended to be operated via a wall thermostat meet federal ADA compli-

Thermostat

ance requirements when used in conjunction with an ADA compliant wall thermostat mounted

 

more than 15” and less than 48” from the ground.

14

GE AJCQ06LCG, AJCM10DCG, AJCQ08ACG Maintance Manual

Installation Instructions

,167$//,1* $ - 02'(/ ,1 $1 (;,67,1* :$// &$6(

Read these instructions completely and carefully.

1

5(029( $// 6+,33,1* 0$7(5,$/

 

,) 35(6(17 ,16,'( $,5 &21',7,21(5

 

NEXT TO COMPRESSOR

2

R(029( 7+( ),/7(5 $1' )5217 *5,//(

Remove the two screws behind the filter then remove the front grille.

3&$5()8//< 6/,'( $,5 &21',7,21(5

INTO CASE

Make sure that the tubing on the unit does not touch the wall case and that the case installation is secure.

45(,167$// /2&.,1* 3/$7( :,7+ 7$%

%(+,1' :$// &$6( )/$1*( 7,*+7(1

SCREW

Locking

plate

Tighten

screw

$77$&+ )5217 *5,//(

5 An opening for the power cord is on the bottom of the front grille.

15

Installation Instructions

,167$//,1* 7+528*+ 7+( :$//

Read these instructions completely and carefully.

1 PREPARE OPENING IN WALL

Make certain a wall receptacle is available close

to the hole location or make arrangements to install a receptacle.

The cord length for the 115-volt models is 72s to the right and 47sto the left.

For the 230/208-volt models the cord length is 65s to the right and 39s to the left.

MINIMUM

),1,6+('

OPENING

 

',0(16,216

&$6( ',0(16,216

 

+HLJKW

:LGWK

+HLJKW

:LGWK

'HSWK

 

*Dimensions may need

 

 

 

 

 

 

 

 

 

3

1

5

 

 

 

 

to be increased to fit

26

1

16s

unique situations in the

 

15 ø4s

26 ø8s

15 ø8s

 

ø16s

field if using case angles.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3SUPPORT REQUIREMENTS FOR AIR

&21',7,21(5

Mortar between the case and the brick wall around the case may be undercut at about 45° for improved caulking.

 

Inside

 

Top of case

 

Outside

Caulking

Undercut

 

mortar

2SUPPORT REQUIREMENTS FOR AIR

&21',7,21(5

The air conditioner wall case may be installed with 1/4smin. extension out from the inside wall

or with 1/4smin. extension out from the outside wall.

The finished sides of the opening should be structural wall members.

/LQWHO ² Use a lintel in brick veneer and brick and block types of wall to support the bricks

or blocks above the opening. Do not allow the wall case to be used in lieu of a lintel.

)ODVKLQJ ² Install flashing (drip rail) as shown to prevent water from dripping inside the wall and down the outside of the building.

Brick veneer

Lintel angle

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(if required)

 

 

 

 

 

 

 

 

 

Plaster line

 

 

 

 

 

 

 

 

 

Caulking

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(on all 4 sides

 

 

 

 

 

 

 

 

 

 

on the outside

 

 

 

 

 

 

 

 

 

Trim

and inside

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

molding

of the case)

 

 

 

 

 

 

 

 

 

 

 

 

 

Caulking

 

(if desired)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(above

 

Room side

 

 

 

 

 

and

 

 

 

 

 

 

 

 

 

 

 

 

 

below the

 

 

 

 

 

 

 

flashing)

 

 

Flashing

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(drip rail)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1/4smin. extension

 

 

 

 

 

inside the wall from

 

 

 

 

 

 

 

 

 

 

 

the trim molding

 

 

16

Before you call for service…

Troubleshooting Tips: Save time and money! Review the chart below first and you may not need to call for service.

Problem

Possible Causes

What To Do

 

 

 

Air conditioner

The air conditioner

• Make sure the air conditioner plug is pushed completely

does not start

is unplugged.

into the outlet.

 

 

 

 

7KHIXVHLVEORZQ FLUFXLW

• Check the house fuse/circuit breaker box and replace

 

breaker is tripped.

the fuse or reset the breaker.

 

 

 

 

Power failure.

• If power failure occurs, turn the air conditioner OFF. When

 

 

power is restored, wait 3 minutes to restart the air conditioner

 

 

to prevent tripping of the compressor overload.

The current interrupter device is tripped.

Press the RESET button located on the power cord plug.

If the RESET button will not stay engaged, discontinue use of the air conditioner and contact a qualified service technician.

Air conditioner does not cool or heat (some models) as it should

Airflow is restricted.

• Make sure there are no curtains, blinds or furniture blocking

 

the front of the air conditioner.

 

 

The temp control may

• In COOL mode or HEAT mode (some models), press the

not be set correctly.

DECREASE – pad.

 

 

The air filter is dirty.

• Clean the filter at least every 30 days.

 

See the Operating Instructions section.

The room may have been hot.

When the air conditioner is first turned on, you need to allow time for the room to cool down.

 

Cold air is escaping.

• Check for open furnace registers and cold air returns.

 

 

• Make sure the air conditioner’s vent is in the closed position.

 

 

 

 

Cooling coils have iced up.

• See “Air conditioner freezing up” below.

 

 

 

Air conditioner

Ice blocks the airflow

• Set the controls at HIGH FAN or HIGH COOL and set the

freezing up

and stops the air conditioner

thermostat to a higher temperature to allow the ice to melt.

 

from cooling the room.

• Check filter for cleanliness.

 

 

 

The remote control is

The batteries are inserted

• Check the position of the batteries. They should be

not working

incorrectly.

inserted correctly.

 

 

 

 

The batteries may be dead.

• Replace the batteries.

 

 

 

Water drips outside

+RW KXPLGZHDWKHU

• This is normal.

 

 

 

Water drips indoors

The air conditioner is not

• For proper water disposal, make sure the air conditioner

 

tilted to the outside.

case is level or slants slightly from the case front to the rear.

 

 

 

Water collects in

Moisture removed from air

• This is normal for a short period in areas with little

base pan

and drains into base pan.

humidity; normal for a longer period in very humid areas.

Normal Operating Sounds

You may hear a pinging noise caused by water being picked up and thrown against the condenser on rainy days or when the humidity is high. This design feature helps remove moisture and improve efficiency.

You may hear the thermostat click when the compressor cycles on and off.

Water will collect in the base pan during high humidity or on rainy days. The water may overflow and drip from the outdoor side of the unit.

The fan may run even when the compressor does not.

17

Notes.

18

Loading...
+ 42 hidden pages