Mounting Instructions
may or may not include
all components shown for kit installation
D103999X012
May 2014
Digital Valve Controller on
Use these instructions to mount a FIELDVUE™
DVC6200/DVC2000 to a Linear Actuator.
Avoid personal injury or property
damage from sudden release of process
pressure or bursting of parts. Before
performing any maintenance
operations:
Always wear protective clothing,
gloves, and eyewear.
Do not remove the actuator from
the valve while the valve is still
pressurized.
Disconnect any operating lines
providing air pressure, electric power, or
a control signal to the actuator. Be sure
the actuator cannot suddenly open or
close the valve.
Use bypass valves or completely
shut off the process to isolate the valve
from process pressure. Relieve process
pressure from both sides of the valve.
Vent the pneumatic actuator
loading pressure and relieve any
actuator spring precompression.
Use lock-out procedures to be sure
that the above measures stay in effect
while you work on the equipment.
Check with your process or safety
engineer for any additional measures
that must be taken to protect against
process media.
The visual aids in this document are for general
reference representation only. Refer to the
appropriate actuator instruction manual for actuator
installation, operation, maintenance, and parts
identification as this manual
.
1. Isolate the control valve from the process line
pressure and release pressure from both sides of the
valve body. Shut off all pressure lines to the actuator,
releasing all pressure from the actuator. Use lock-out
procedures to be sure that the above measures stay in
effect while you work on the equipment.
2. Attach connector arm to stem block using
existing or provided fasteners (including spacers and
stud bolts, if applicable).
1

Digital Valve Controller on
For fork-style connector arms remove the jam nuts
and indicator disk from the stem. Place the fork-style
extension arm flush with the bottom of the stem block
onto the Valve Stem. Reattach the indicator disk and
nuts.
Mounting Instructions
D103999X012
May 2014
3. Attach extension arm to connector arm using
provided fasteners.
2

Mounting Instructions
(Array not included with kit)
D103999X012
May 2014
4. Attach mounting bracket to actuator using
provided fasteners and spacers if required for your
application.
Digital Valve Controller on
5. Loosely attach array to extension arm using
provided fasteners. Fasteners to be tightened upon
array adjustment.
3

Digital Valve Controller on
6. Attach aligning template to mounting bracket.
Mounting Instructions
D103999X012
May 2014
7. Align array with aligning template. Once the array
is aligned with the mark remove the template from the
mounting bracket.
4

Mounting Instructions
D103999X012
May 2014
8. Attach device to mounting bracket using
provided fasteners.
Digital Valve Controller on
9. Attach shield to mounting plate using provided
fasteners if applicable.
5

Digital Valve Controller on
Finished Assembly
Mounting Instructions
D103999X012
May 2014
6

Mounting Instructions
D103999X012
May 2014
Digital Valve Controller on
Air Filter Regulator
Alignment Template
Connector Arm
DVC6200
Common Mounting
Bracket
Extension Arm
Shield
Linear Feedback Array
Spacer
DVC2000
Insert Assembly
U-Bracket
7

Digital Valve Controller on
Neither Emerson, Emerson Process Management, Fisher, nor any of their affiliated entities assumes responsibility for the selection, use and
maintenance of any product. Responsibility for the selection, use and maintenance of any product remains with the purchaser and end user.
Emerson Process Management
Mounting Instructions
D103999X012
May 2014
Fisher and FIELDVUE are marks owned by Fisher Controls International LLC, a member of the Emerson Process Management business unit of Emerson Electric
Co. Emerson Process Management, Emerson, and the Emerson logo are trademarks and service marks of Emerson Electric Co. All other marks are the
property of their respective owners.
The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not to
be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. We reserve the
right to modify or improve the designs or specifications of such products at any time without notice.
Marshalltown, Iowa 50158 USA
Sorocaba, 18087 Brazil
Chatham, Kent ME4 4QZ UK
Dubai, United Arab Emirates
Singapore 128461 Singapore
_____________________________________________________________________________________________________
© 2014 Fisher Controls International LLC. All right reserved.
8