Mounting Instructions
may or may not include
all components shown for kit installation
D103996X012
May 2014
Use these instructions to mount a FIELDVUE™
DVC6200/DVC2000 to a Linear Actuator.
Avoid personal injury or property
damage from sudden release of process
pressure or bursting of parts. Before
performing any maintenance
operations:
Always wear protective clothing,
gloves, and eyewear.
Do not remove the actuator from
the valve while the valve is still
pressurized.
Disconnect any operating lines
providing air pressure, electric power, or
a control signal to the actuator. Be sure
the actuator cannot suddenly open or
close the valve.
Use bypass valves or completely
shut off the process to isolate the valve
from process pressure. Relieve process
pressure from both sides of the valve.
Vent the pneumatic actuator
loading pressure and relieve any
actuator spring precompression.
Use lock-out procedures to be sure
that the above measures stay in effect
while you work on the equipment.
Check with your process or safety
engineer for any additional measures
that must be taken to protect against
process media.
The visual aids in this document are for general
reference representation only. Refer to the
appropriate actuator instruction manual for actuator
installation, operation, maintenance, and parts
identification as this manual
.
Digital Valve Controller on
1. Isolate the control valve from the process line
pressure and release pressure from both sides of the
valve body. Shut off all pressure lines to the actuator,
releasing all pressure from the actuator. Use lock-out
procedures to be sure that the above measures stay in
effect while you work on the equipment.
2. Attach connector arm assembly to stem block
using provided fasteners (including spacers and stud
bolts, if applicable).
1

Mounting Instructions
Array not included with kit)
D103996X012
May 2014
For fork-style connector arms remove the nuts and
indicator disk from the stem. Place the fork-style
extension arm flush with the bottom of the stem block
onto the stem. Reattach the indicator disk and nuts.
Digital Valve Controller on
3. Loosely attach array to extension arm using
provided fasteners. (
2

Mounting Instructions
D103996X012
May 2014
4. Attach extension arm with array assembly to
connector arm.
Digital Valve Controller on
5. Attach mounting plate to actuator using provided
hardware (including stud bolts, spacers, and
L-brackets, if applicable).
3

Mounting Instructions
***Care
needs to be taken to ensure that line the index marks
on the array do not move outside of the center index
mark on the alignment template***
D103996X012
May 2014
6. Attach aligning template to mounting plate.
Adjust height of array until the middle line of the
aligning template is level with the corresponding line
of the array relative to stem block position.
Digital Valve Controller on
4

Mounting Instructions
D103996X012
May 2014
7. Attach insert assembly into the magnet housing
slot on the back of the device using the provided 3m
adhesive strip.
Digital Valve Controller on
8. Remove aligning template. Attach device to
mounting bracket using provided fasteners.
5

Mounting Instructions
D103996X012
May 2014
9. Attach remote mount air filter regulator (if
applicable).
Digital Valve Controller on
Final Assembly
6

Mounting Instructions
D103996X012
May 2014
Air Filter Regulator
DVC6200
Digital Valve Controller on
Shield
Alignment Template
Connector Arm
Common Mounting Bracket
Extension Arm
Insert Assembly
Linear Feedback Array
Spacer
U-Bracket
DVC2000
7
Mounting Plate

Mounting Instructions
Neither Emerson, Emerson Process Management, Fisher, nor any of their affiliated entities assumes responsibility for the selection, use and
maintenance of any product. Responsibility for the selection, use and maintenance of any product remains with the purchaser and end user.
described herein or their use or applicability. We reserve the
Emerson Process Management
D103996X012
May 2014
Digital Valve Controller on
Fisherand FIELDVUE are marks owned by Fisher Controls International LLC, a member of the Emerson Process Management business unit of Emerson Electric
Co. Emerson Process Management, Emerson, and the Emerson logo are trademarks and service marks of Emerson Electric Co. All other marks are the
property of their respective owners.
The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not to
be construed as warranties or guarantees, express or implied, regarding the products or services
right to modify or improve the designs or specifications of such products at any time without notice.
Marshalltown, Iowa 50158 USA
Sorocaba, 18087 Brazil
Chatham, Kent ME4 4QZ UK
Dubai, United Arab Emirates
Singapore 128461 Singapore
_____________________________________________________________________________________________________
© 2014 Fisher Controls International LLC. All right reserved.
8