Elica EVR636S2, EVL436S2, EVR636BL Installation Manual

0 (0)

Models: EVL430S2 EVL436S2 EVL424SS EVR630S2 EVR636S2 EVR630BL EVR636BL

Use, Care, and

Installation Guide

Guide d’utilisation, d’entretien et d’installation

Guía de instalación, uso y mantenimiento

READ AND SAVE THESE

INSTRUCTIONS

LISEZ CES

INSTRUCTIONS ET

CONSERVEZ-LES

LEA Y CONSERVE ESTAS INSTRUCCIONES

LIB0139140A

Printed in Mexico

06/18

1

ENGLISH

Contents

 

Important safety notice.................................................................................................................................................................................................

3

Electrical & installation requirements ................................................................................................................................................................

4

Before installing the hood ......................................................................................................................................................................................

4

Product dimensions .......................................................................................................................................................................................................

4

List of materials.................................................................................................................................................................................................................

5

Parts supplied ..............................................................................................................................................................................................................

5

Parts not supplied ......................................................................................................................................................................................................

5

Ducting options and examples..................................................................................................................................................................................

6

Installation .........................................................................................................................................................................................................................

6

Electrical connection................................................................................................................................................................................................

8

Complete the installation........................................................................................................................................................................................

9

Description of the hood.................................................................................................................................................................................................

9

Control..................................................................................................................................................................................................................................

9

Maintenance ......................................................................................................................................................................................................................

10

Warranty ...........................................................................................................................................................................................................................

11

APPROVED FOR RESIDENTIAL APPLIANCES

FOR RESIDENTIAL USE ONLY

READ AND SAVE THESE INSTRUCTIONS

PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING.

INSTALLATION MUST COMPLY WITH ALL LOCAL CODES.

IMPORTANT: Save these Instructions for the Local Electrical Inspector’s use.

INSTALLER: Please leave these Instructions with this unit for the owner.

OWNER: Please retain these instructions for future reference.

Safety Warning: Turn off power circuit at service panel and lock out panel, before wiring this appliance. Requirement: 120 V AC, 60 Hz. 15 or 20 A Branch Circuit.

2

I IMPORTANT SAFETY NOTICE

I CAUTION

FOR GENERAL VENTILATING USE ONLY. DO NOT USE TO EXHAUST HAZARDOUS OR EXPLOSIVE MATERIALS OR VAPOURS.

IWARNING

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:

A.Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer.

B.Before servicing or cleaning the unit, switch power off at service panel and lock service panel disconnecting means to prevent power from being switched on accidentally.

When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.

C.Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes & standards, including fire-rated construction.

D.Sufficient air is needed for proper combustion and exhausting of gases through the flue (Chimney) of fuel burning equipment to prevent backdrafting.

Follow the heating equipment manufacturers guideline and safety standards such as those published by the national fire protection association (NFPA), the american society for heating, refrigeration and air conditioning engineers (ASHRAE), and the local code authorities.

E.When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.

F.Ducted systems must always be vented to the outdoors.

I CAUTION

To reduce risk of fire and to properly exhaust air, be sure to duct air outside - do not vent exhaust air into spaces within walls, ceilings, attics, crawl spaces, or garages.

IWARNING

TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCT WORK.

Install this hood in accordance with all requirements specified.

IWARNING

To reduce the risk of fire or electric shock, do not use this hood with any external solid state speed control device.

IWARNING

TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE.

a)Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium settings.

b)Always turn hood ON when cooking at high heat or when flambeing food (I.e. Crepes Suzette, Cherries Jubilee, Peppercorn Beef Flambe’).

c)Clean ventilating fans frequently. Grease should not be allowed to accumulate on fan or filter.

d)Use proper pan size. Always use cookware appropriate for the size of the surface element.

IWARNING

TO REDUCE THE RISK OF INJURY TO PERSONS, IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING:a

a)SMOTHER FLAMES with a close-fitting lid, cookie sheet, or other metal tray, then turn off the gas burner or the electric element. BE CAREFUL TO PREVENT BURNS. If the flames do not go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT.

b)NEVER PICK UP A FLAMING PAN - you may be burned.

c)DO NOT USE WATER, including wet dishcloths or towels - a violent steam explosion will result.

d)Use an extinguisher ONLY if:

1)You know you have a class ABC extinguisher, and you already know how to operate it.

2)The fire is small and contained in the area where it started.

3)The fire department is being called.

4)You can fight the fire with your back to an exit.

e)Ducted fans must always be vented to the outdoor.

aBased on “Kitchen Fire Safety Tips” published by NFPA.

I CAUTION

Automatically Operated Device - To reduce the risk of Injury disconnect from power supply before servicing.

3

ELECTRICAL & INSTALLATION REQUIREMENTS

IMPORTANT

Observe all governing codes and ordinances.

It is the customer’s responsibility:

To contact a qualified electrical installer.

To assure that the electrical installation is adequate and in conformance with National Electrical Code, ANSI/NFPA 70

— latest edition*, or CSA Standards C22.1-94, Canadian Electrical Code, Part 1 and C22.2 No.0-M91-latest edition** and all local codes and ordinances.

If codes permit and a separate ground wire is used, it is recommended that a qualified electrician determine that the ground path is adequate.

Do not ground to a gas pipe.

Check with a qualified electrician if you are not sure range hood is properly grounded.

Do not have a fuse in the neutral or ground circuit.

IMPORTANT

Save Installation Instructions for electrical inspector’s use.

The range hood must be connected with copper wire only.

The range hood should be connected directly to the fused disconnect (Or circuit breaker) box through metal electrical conduit.

Wire sizes must conform to the requirements of the National Electrical Code ANSI/NFPA 70 — latest edition*, or CSA Standards C22.1-94, Canadian Electrical Code Part 1 and C22.2 No. 0-M91 - latest edition** and all local codes and ordinances.

A U.L.- or C.S.A.-listed conduit connector must be provided at each end of the power supply conduit (at the range hood and at the junction box).

Copies of the standards listed may be obtained from:

*National Fire Protection Association Batterymarch Park Quincy, Massachusetts 02269

**CSA International 8501 East Pleasant Valley Road Cleveland, Ohio 44131-5575

BEFORE INSTALLING THE HOOD

1For the most efficient air flow exhaust, use a straight run or as few elbows as possible.

CAUTION: Vent unit to outside of building, only.

2At least two people are necessary for installation.

3Fittings material is provided to secure the hood to most types of walls/ceilings, consult a Qualified Installer, check if they perfectly fit with your cabinet/wall.

4Do not use flex ducting.

5COLD WEATHER installations should have an additional backdraft damper installed to minimize backward cold air flow and a nonmetallic thermal break to minimize conduction of outside temperatures as part of the ductwork. The damper should be on the cold air side of the thermal break.

The break should be as close as possible to where the ducting enters the heated portion of the house.

6Make up air: Local building codes may require the use of Make-Up Air Systems when using Ducted Ventilation Systems greater than specified CFM of air movement. The specified CFM varies from locale to locale. Consult your HVAC professional for specific requirements in your area.

PRODUCT DIMENSIONS

F

E

 

 

 

Models

 

 

 

 

 

 

 

 

 

 

 

EVL424SS

EVL430S2

EVL436S2

G

 

 

 

 

EVR630S2

EVR636S2

 

 

 

 

EVR630BL

EVR636BL

 

 

 

 

 

 

 

 

A

2358” (60 cm)

30” (76.2 cm)

36” (91.4 cm)

 

 

 

B

 

191116” (50 cm)

 

 

 

C

C*

 

Max: 42

1

⁄ ” (107 cm)

 

 

 

 

 

 

8

 

 

 

 

 

 

Min: 28616” (72 cm)

 

 

 

D

D**

 

Max: 38316” (97 cm)

 

 

 

 

 

 

 

 

 

 

 

Min: 28616” (72 cm)

 

 

 

 

E

 

6” (15.24 cm)

 

 

 

 

F

 

7316” (18.3 cm)

 

 

 

 

G

 

8316” (20.8 cm)

 

A

B

 

 

 

 

 

 

 

 

*

Ductless (Recirculating) version

 

 

 

 

 

 

**

Ducted version

 

 

 

 

4

LIST OF MATERIALS

Removing the packaging.

I CAUTION

Remove carton carefully, Wear gloves to protect against sharp edges.

I WARNING

Remove the protective film covering the product before putting into operation.

Supplied Part

Pieces

1

Hood assembly and

LED lamps already installed

6 5x45 mm

5.4x75 mm

4

 

3.5x9.5 mm

2

 

4x8 mm

2

 

Torx 10 adapter

1

 

Supplied Part

Pieces

2

Duct covers

1

6” round air transition

2 8x40 mm

4 10x60 mm

1 Duct cover bracket

1

Mounting template

Parts no supplied

Tools/Materials required

Optional accessories and consumable parts

• Level

KIT

# Part

• Drill

• 114” (3.2 cm), 18” (3.2 mm), and 116” (4.8 mm) drill bits

 

 

 

 

• Pencil

Recirculating Kit

KIT02766

• Wire stripper or utility knife

 

 

• Tape measure or ruler

Long Chimney

KIT02762

• Pliers

Extension

 

• Caulking gun and weatherproof caulking compound

 

 

 

 

• Jigsaw or keyhole saw

Long Chimney

KIT0140998

• Metal snips

Extension Black

 

• Screwdrivers:

 

 

 

 

- Flat-blade

 

 

- Phillips

 

 

5

Ducting Options

Closely follow the instructions set out in this manual.

All responsability, for any eventual inconveniences, damages or fires caused by not complying with the instructions in this manual, is declined.

Ducting version

Ductless (Recirculating)

The hood is equipped with a 6” (15.2 cm) round transition for discharge of fumes to the outside.

Roof Venting

A

B

Wall Venting

B

A

A.

Roof cap

A.

Wall cap

B.

6” (15.2 cm) round vent

B.

6” (15.2 cm) round vent

In cases where it should not be possible to discharge cooking fumes and vapour to the outside.

Attach a charcoal filter and the deflector on the duct cover support bracket. Fumes and vapours are recycled through the top grille by means of a duct connected to the transition and the transition mounted on the deflector.

For this version only: purchase the Ductless Recirculating Kit. Minimum Duct Size: 6” Round Pipe.

A

B

A.Deflector

B.6” (15.2 cm) round vent

Preparation

Do not cut a joist or stud unless absolutely necessary. If a joist or stud must be cut, then a supporting frame must be constructed.

Fittings material is provided to secure the hood to most types of walls/ceilings.

However, a qualified technician must verify suitability of the materials in accordance with the type of wall/ceiling. Before making cutouts, make sure there is proper clearance within the ceiling or wall for exhaust vent.

Recommended installation height:

Hood installation height above cooktop is the users preference. The lower the hood is above the cooktop, the more efficient the capturing of cooking odors, grease and smoke.

Installation

I CAUTION

 

Installation Heights

Hood

EVL430S2,

EVR630S2, EVR636S2,

models

EVL436S2,

EVR630BL, EVR636BL

 

EVL424SS

 

 

 

 

 

GAS

27″ (66.6 cm)

30″ (76.2 cm)

cooktops

 

 

ELECTRIC

24″ (61 cm)

27″ (66.6 cm)

cooktops

 

 

There is no maximum mounting height, however, we recommend mounting the hood no greater than 36” (91.4 cm) above the cooking surface. For every inch (2.54 cm) above 36” (91.4 cm), fume and moisture capture efficiency diminishes at an increasing rate and may not deliver an acceptable level of ventilating performance.

This hood is intended for household use.

PLEASE READ THE INSTALLATION MANUAL FOR SPECIFIC APPLICATION. Check your ceiling height and hood height before selecting your hood.

Prepare location

It is recommended that the vent system be installed before hood is installed.

Before making cutouts, make sure there is proper clearance within the ceiling or wall for exhaust vent.

Check your ceiling height and the hood height maximum before you select your hood.

1Disconnect power.

2Determine which venting method to use: roof, wall, or nonvented.

3Select a flat surface for assembling the range hood. Place covering over that surface.

I WARNING

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING.

4Using 2 or more people, lift range hood onto covered surface.

6

A

Mounting the duct cover bracket

1Determine and mark the centerline on the wall where the canopy hood will be installed. Disconnect power.

2Select a mounting height from the Installation Heights chart. Mark a reference line on the wall.

3Tape template in place, aligning the template centerline and bottom of template with hood bottom line and with the centerline marked on the wall.

C

B

A.Centerline

B.Fastener locations

C.Mounting height reference (hood bottom line)

4Mark centers of the fastener locations through the template to the wall.

IMPORTANT: All screws must be installed into wood.

If there is no wood to screw into, additional wall framing supports may be required.

5Remove the template.

6Drill 316” (4.8 mm) pilot holes at all locations where screws are being installed into wood.

7Install the 2 - 5 x 45 mm mounting screws. Leave a 14” (6.4 mm) gap between the wall and the back of the screw head to slide range hood into place.

14

(6.4 mm)

Vent cover bracket installation

1Attach vent cover bracket to wall flush to the ceiling using 2 - 5 x 45 mm screws.

 

A

 

C

 

D

B

 

A. 8 x 40 mm anchors

C. Vent cover support bracket

B. Centerline on wall

D. 5 x 45 mm screws

Complete preparation

1Determine and make all necessary cuts in the wall for the vent system. Install the vent system before installing the hood. See “Venting Requirements” section.

2Determine the required height for the home power supply cable and drill a 1¼” (3.2 cm) hole at this location.

3Run the home power supply cable according to the National Electrical Code or CSA Standards and local codes and ordinances. There must be enough ½” conduit and wires from the fused disconnect (or circuit breaker) box to

make the connection in the hood’s electrical terminal box. NOTE: Do not reconnect power until installation is complete. 4 Use caulk to seal all openings.

Install Range Hood

1Using 2 or more people, hang range hood on 2 mounting screws through the mounting slots on back of hood.

A

B

C

A. Mounting screws

B. Mounting slots

C. Lower mounting screws

1

2Mark with a pencil the lower mounting holes location.

3Uninstall the hood assembly, and drill 316” (4.8 mm) pilot holes at marked locations.

4Hang the range hood again on 2 upper mounting screws.

5Level the range hood and tighten upper mounting screws.

6Install 2 - 5 x 45 mm lower mounting screws and tighten. Use the optional wall anchors if needed.

Connect Vent System

1Install transition on top of hood (if removed for shipping) with 2 - 3.5 x 9.5 mm sheet metal screws.

A

B

A.Vent transition

B.3.5 x 9.5 mm screw

For vented installations only:

1Fit vent system over the exhaust outlet.

2Measure from the bottom of the air deflector to the bottom of the hood outlet. Cut the ductwork at the measured dimension.

Roof outlet

Wall outlet

Dimension to measure

3Seal connection with clamps.

4Check that back draft dampers work properly.

7

Electrical Connection

I WARNING

ELECTRICAL SHOCK HAZARD.

I WARNING

DISCONNECT POWER BEFORE SERVICING.

REPLACE ALL PARTS AND PANELS BEFORE OPERATING. FAILURE TO DO SO CAN RESULT IN DEATH OR ELECTRICAL SHOCK.

1Disconnect power.

2Remove terminal box cover.

3Remove the knockout in the terminal box cover and install a UL listed or CSA approved 12” strain relief.

4Run home power supply cable through strain relief, into terminal box.

E

D

C

B

A

A.Home power supply cable

B.UL listed or CSA approved strain relief

C.Black wires

D.UL listed wire connectors

E.White wires

F.Green (or bare) and yellow-green ground wires

5Use UL listed wire connectors and connect black wires

(C) together.

6Use UL listed wire connectors and connect white wires (E) together.

I WARNING

ELECTRICAL SHOCK HAZARD.

I WARNING

ELECTRICALLY GROUND BLOWER.

CONNECT GROUND WIRE TO GREEN AND YELLOW GROUND WIRE IN TERMINAL BOX. FAILURE TO DO SO CAN RESULT IN DEATH OR ELECTRICAL SHOCK.

7Connect green (or bare) ground wire from home power supply to yellow-green ground wire (F) in terminal box using UL listed wire connectors.

8Tighten strain relief screw.

9Install terminal box cover.

10Check that all light bulbs are secure in their sockets.

11Reconnect power.

Install duct covers

When using both upper and lower vent covers, push lower cover down onto hood and lift upper cover to ceiling and install with two mounting screws.

NOTE: For vented installations, the upper vent cover may be reversed to hide slots.

C

D

C

A

B

A.Upper vent cover

B.Lower vent cover

C.4 x 8 mm screws

D.Bracket

NOTE: To prevent scratches, lay paper or a kitchen towel over the edges of the lower flue duct to protect the surface.

8

Complete Installation

 

Control

 

 

 

For non-vented (recirculating) installations only, install charcoal filters over metal grease filter.

See the “Mainteinance” section.

Install metal filters. See the “Mainteinance” section.

To get the most efficient use from your new range hood, read the “Maintenance” section.

Keep your Use, Care, and installation Guide close to range hood for easy reference.

Description of the Hood

EVR630 & EVR636 models

5

1

2

3

4

1.Blower and light controls

2.LED lamps

3.Grease filter handle

4.Grease filter

5.Duct covers

1

 

2

 

3

 

4

 

5

 

6

 

 

 

 

 

 

 

 

 

 

 

1.Button ON/OFF motor (stand by)

2.Button for low speed (suction power) selection

When flashing, it indicates that you must wash the grease filter.

3.Button for medium speed (suction power) selection

4.Button for high speed (suction power) selection

5.Button for intensive speed (suction power) selection It lasts 5 minutes then it returns to medium speed (suction power).

6.Button ON/OFF lighting

Press briefly to switch on or off the lighting of the hood. Press and hold to adjust the intensity of the light.

Indicators of filter saturation:

At regular time intervals, the hood indicates the need of performing filter maintenance.

Button on with steady light:

Perform grease filter maintenance.

Button flashing:

Perform activated charcoal filter maintenance.

NOTE: Filter saturation signal is visible within the first minute after switching off the hood; within this time, the reset of saturation indicators must be performed.

Reset of filter saturation indicators:

Press and hold the button

Activation of saturation indicator activated charcoal filter: NOTE: This operation must be performed with the hood off. This indicator is normally deactivated; press and hold the

button to activate the function: the button lights up with steady light.

To deactivate the function, press and hold the button , the button lights up flashing.

CFM Reduction System

Before operating your hood:

Some States and Provinces of the US & Canada restrict the maximum exhausting airflow of range hoods.

Airflow is measured as cubic feet per minute (CFM).

These maximum levels allowed are detailed in the local code of your area. Please check local codes to find out if you need to restrict the maximum airflow of your hood. If your local code mandates a maximum airflow level below the maximum airflow of this hood (i.e.600CFM),please execute the procedure below to reduce the maximum airflow.

1

 

5

 

 

 

 

 

 

 

 

 

 

1Turn the motor OFF.

2Press the ON/OFF (1) and Intensive speed (5) buttons together for 3 seconds.

You will hear a beep and all control lights will illuminate for 3 seconds.

This action will Disable speeds 3 and 4 and effectively lower the Maximum airflow to > 300 CFM.

3Locate the CFM certification sticker in the hardware pack.

4Peel and Affix this sticker to a visible area in the blower. This sticker provides official certification to your local inspector that this hoods maximum airflow has been reduced to > 300 CFM.

9

Elica EVR636S2, EVL436S2, EVR636BL Installation Manual

EVL424SS, EVL430S2 & EVL436S2 models

5

1

2

3

4

1.Blower and light controls

2.LED lamps

3.Grease filter handle

4.Grease filters

5.Duct covers

Control

Maintenance

Cleaning

Do not spray cleaners directly to the control while cleaning the Hood. The cooker hood should be cleaned regularly (at least with the same frequency with which you carry out maintenance of the fat filters) internally and externally. Clean using the cloth dampened with neutral liquid detergent. Do not use abrasive products. Do not use chlorine base cleaners.

DO NOT USE ALCOHOL!

IWARNING:

Failure to carry out the basic cleaning recommendations of the cooker hood and replacement of the filters may cause fire risks. Therefore, we recommend oserving these instructions.

The manufacturer declines all responsibility for any damage to the motor or any fire damage linked to inappropriate maintenance or failure to observe the above safety recommendations.

Grease Filter

Traps cooking grease particles.

This must be cleaned once a month using non aggressive detergents, either by hand or in the dishwasher, which must be set to a low temperature and a short cycle. When washed in a dishwasher, the grease filter may discolour slightly, but this does not affect its filtering capacity.

To remove the grease filter, pull the spring release handle.

EVR630 & EVR636 models

EVL424, EVL430 & EVL436 models

A

A

1.Light On/Off button

2.Blower On/Off button

3.Blower speed minimum button

4.Blower speed medium button

5.Blower speed maximum button

NOTE: Control buttons will light up when range hood is On.

Operating the light

The Light On/Off button (1) controls both lights. Press once for On and again for Off.

Operating the blower

The Blower On/Off button (2) turns the blower On or Off. The Blower Speed buttons (3, 4 and 5) set the desired speed and control the sound level for quiet operation. The speed can be changed anytime during fan operation by pressing the desired blower speed button.

1To turn the blower On, press the Blower On/Off button (2) and the desired speed button (3, 4 or 5).

2To turn the blower Off, press the Blower On/Off button (2).

Any of the 3 blower speed buttons can be in the On position at the same time. The blower will operate at the highest speed button that is pushed in. For lower blower speeds, the higher

speed buttons must not be pushed in.

A.Spring release handle

Replacing a LED Lamp

The LED lights are replaceable by a service technician only. See “Who to contact” section in the warranty for service contact information.

Charcoal filter NOTE

When used in recirculation mode, To Reduce the Risk of Fire and Shock use only conversion kit Models:

Recirculating kit: KIT02766

If the model is not vented to the outside, the air will be recirculated through disposable charcoal filters that help remove smoke and odors.

1Cover the grill that protects the suction motor with the carbon filter so that the slots on the filter correspond to the pins on the sides of the motor protection grill.

2Turn the carbon filter clockwise to block them (bayonet fixing).

NOTE: The charcoal filters cannot be cleaned. It should be replaced every 4-6 months (depending on hood usage).

10