Deutz DTC Service Manual

DTC - List Modified for FSDS
Diagnosis- and Fehlercodes
Error Path DEUTZ SPN Blink

AirFltSysReac 11 107 1-3-6 APP1 12 91 2-2-6 APPPwm 14 91 2-2-2 APPPwmPer 15 91 2-2-2 APSCD 16 108 2-9-2 ArHt1 17 729 2-6-3 ArHt2 18 730 2-6-3 ArHtCD_NoLd 19 676 2-6-3 ArHtCD_RlyErr 20 676 2-6-3 BattCD 22 168 3-1-8 BattCDSysReac 23 168 3-1-8 BIPCyl1 24 523561 5-3-1 BIPCyl2 25 523562 5-3-2 BIPCyl3 26 523563 5-3-3 BIPCyl4 27 523564 5-3-4 BIPCyl5 28 523565 5-3-5 BIPCyl6 29 523566 5-3-6 BIPCyl7 30 523567 5-3-7 BIPCyl8 31 523568 5-3-8 BPSCD 32 102 2-2-3 BPSCDSysReac 33 102 2-2-3 CLSCDSysReac 37 111 2-3-5 CmbChbMisfire1 38 1323 2-4-1 CmbChbMisfire2 39 1324 2-4-1 CmbChbMisfire3 40 1325 2-4-1 CmbChbMisfire4 41 1326 2-4-1 CmbChbMisfire5 42 1327 2-4-1 CmbChbMisfire6 43 1328 2-4-1 CmbChbMisfire7 44 1450 2-4-1 CmbChbMisfire8 45 1451 2-4-1 CmbChbMisfireMul 46 1322 2-4-1 CmbChbSysReac 47 1346 2-4-1 CoEngShOffDemIgr 48 1109 3-4-1 CRERCD 52 1072 5-2-8 CSLpCD 53 1081 3-2-8

Referenced ECU Software P490_: 220, 310, 501 P491_: 220, 310, 400, 501
P492_: 213 P513_: 214, 300
Error Path DEUTZ SPN Blink

CTLpCD 54 704 1-2-3 CTSCD 55 110 2-2-5 CTSCDSysReac 56 110 2-3-2 Dummy1CD_Max 57 701 1-0-0 Dummy1CD_Min 58 701 1-0-0 Dummy1CD_SigNpl 59 701 1-0-0 Dummy2CD_Max 60 702 1-0-0 Dummy2CD_Min 61 702 1-0-0 Dummy2CD_SigNpl 62 702 1-0-0 EGRCD_Max 69 2791 4-1-4 EGRCD_Min 70 2791 4-1-4 EGRCD_SigNpl 71 2791 4-1-5 EGRCDIntEGR 72 2791 4-1-6 EngCDTrqCalcOut 74 923 5-5-5 EngMBackUp 75 190 2-1-2 EngMCaS1 76 190 2-1-2 EngMCrS1 77 190 2-1-2 EngMOfsCaSCrS 78 190 2-1-3 EngPrtSysReacFOC 79 190 2-1-4 EngPrtSysReacORC 80 190 2-1-4 ESLpCD 81 703 1-4-2 ExFlCD 82 1074 2-1-9 FanCD 83 975 2-3-8 FanCDEval 85 1639 2-3-8 FanCDSysReac 86 523602 2-3-8 FlFCD 87 97 2-2-8 FlFCD_WtLvl 89 97 2-2-8 FlPSCD 90 94 2-1-6 FlPSCDSysReac 91 94 2-1-6 FrmMngDecV1 94 523239 5-2-6 FrmMngFunModCtl 95 523240 5-2-7 FrmMngTOEngPrt 106 523212 3-3-3 FrmMngTOPrHtEnCmd 110 523216 3-3-7 FrmMngTORxCCVS 112 523218 1-1-1 FrmMngTORxEngTemp 113 523604 1-1-2

Error Path DEUTZ SPN Blink

FrmMngTOSwtOut 117 523238 1-1-5 FrmMngTOTCO1 118 523222 1-1-6 FrmMngTOTSC1AE 120 523605 1-1-8 FrmMngTOTSC1AR 121 523606 1-1-9 FrmMngTOTSC1DE 122 523607 1-1-8 FrmMngTOTSC1DR 123 523608 1-1-9 FrmMngTOTSC1PE 124 523609 1-1-8 FrmMngTOTSC1TE 125 898 1-1-8 FrmMngTOTSC1TR 126 520 1-1-9 FrmMngTOTSC1VE 127 523610 1-1-8 FrmMngTOTSC1VR 128 523611 1-1-9 FrmMngTxTO 131 523500 2-7-1 FTSCD 133 174 2-2-7 FTSCDSysReac 134 174 2-3-7 GOTSCD 136 523618 1-3-3 GOTSCDSysReac 137 523619 1-3-3 HdThrt 138 29 1-2-6 HOTSCD 139 1638 3-1-4 HOTSCDSysReac 140 1638 3-1-4 HWEMonCom 141 523617 5-5-5 HWEMonEEPROM 142 630 2-8-1 HWEMonRcyLocked 143 523612 5-5-5 HWEMonRcySuppressed 144 523612 5-5-5 HWEMonRcyVisible 145 523612 5-5-5 HWEMonUMaxSupply 146 523612 5-5-5 HWEMonUMinSupply 147 523612 5-5-5 IATSCDk 149 105 1-2-8 IATSCDSysReac 150 105 2-3-3 InjVlvBnk1A 153 523350 1-5-1 InjVlvBnk1B 154 523351 1-5-1 InjVlvCyl2A 155 523352 1-5-2 InjVlvBnk2B 156 523353 1-5-2 InjVlvChipA 157 523354 1-5-3 InjVlvChipB 158 523355 1-5-3 InjVlvCyl1A 159 651 1-5-4

DEUTZ A
G, VS-TA, Fi, Su Page 1 von 67 Rev. 2.0
DTC - List
Diagnosis- and Fehlercodes
Error Path DEUTZ SPN Blink
InjVlvCyl1B 160 651 1-5-4 InjVlvCyl2A 161 652 1-5-5 InjVlvCyl2B 162 652 1-5-5 InjVlvCyl3A 163 653 1-5-6 InjVlvCyl3B 164 653 1-5-6 InjVlvCyl4A 165 654 1-6-1 InjVlvCyl4B 166 654 1-6-1 InjVlvCyl5A 167 655 1-6-2 InjVlvCyl5B 168 655 1-6-2 InjVlvCyl6A 169 656 1-6-3 InjVlvCyl6B 170 656 1-6-3 InjVlvCyl7A 171 657 1-6-4 InjVlvCyl7B 172 657 1-6-4 InjVlvCyl8A 173 658 1-6-5 InjVlvCyl8B 174 658 1-6-5 InjVlvErrDet 175 523370 5-5-5 MeUnCD_ADC 176 523615 1-3-5 MeUnCDNoLoad 177 523615 1-3-5 MeUnCDSCBat 178 523615 1-3-5 MeUnCDSCGnd 179 523615 1-3-5 MnRly1_SCB 182 2634 1-3-7 MnRly1_SCG 183 2634 1-3-8 Montr 184 523420 1-3-9 MRlyCD 186 2634 2-6-1 MRlyCDMnRly2 187 563 2-6-1 MRlyCDMnRly3 188 2634 2-6-1 MSSCD1 189 523450 1-4-3 MSSCD2 190 523451 1-4-3 MSSCD3 191 523452 1-4-3 NetMngCANAOff 192 639 2-7-1 NetMngCANBOff 193 1231 2-7-1 NetMngCANCOff 194 1235 2-7-1 OPLpCD 195 705 1-3-5 OPSCD 196 100 2-2-4 OPSCD1 197 100 2-3-1
Referenced ECU Software P490_: 220, 310, 501 P491_: 220, 310, 400, 501
P492_: 213 P513_: 214, 300
Error Path DEUTZ SPN Blink
OPSCDSysReacHi 198 100 2-3-1 OPSCDSysReacLo 199 100 2-3-1 OSwCD 200 1237 1-4-5 OTSCD 201 175 1-4-4 OTSCDSysReac 203 175 1-4-4 PRVMon 208 523470 1-4-6 RailCD 209 157 1-4-7 RailCDOfsTst 210 157 1-4-7 RailMeUn0 211 523613 1-3-4 RailMeUn1 212 523613 1-3-4 RailMeUn2 213 523613 1-3-4 RailMeUn3 214 523613 1-3-4 RailMeUn4 215 523613 1-3-4 RailMeUn7 216 523613 1-3-4 SOPTst 218 523490 1-4-9 SSpMon1 219 1079 2-8-2 SSpMon2 221 1080 2-8-2 SSpMon3 222 523601 2-8-2 StrtCDHS 223 677 5-1-2 StrtCDLS 224 677 5-1-2 SysLamp 225 624 5-1-3 T15CD 226 158 5-1-4 T50CD 227 523550 5-1-5 TPUMon 228 523550 5-5-5 VSSCD1 232 84 5-2-1 WdCom 235 523600 5-5-5 PRVMonSysReac 236 523470 1-4-6 APPCDSwtnSel 237 523006 2-4-2 FrmMng_TORxEngPress 238 523007 2-1-5 MplCtl 239 523008 4-2-4 OLSCD 240 98 2-1-1 OLSCDSysReacHi 241 98 2-5-1 ADPSCDAna 242 107 1-3-6 OLSCDSysReacLo 243 98 2-5-2 PrvMonWear 244 523009 2-5-3
Error Path DEUTZ SPN Blink
RailMeUn8 245 523010 2-5-4 FlSys_FLPFMSysReac 246 523650 5-4-1 FlSys_FTSFMSysReac 247 523651 5-4-2 FlSys_FlushStateEngineOff 248 523652 5-4-3 FlSys_RapeOilHeatEx 249 523653 5-4-4 FrmMngDieselLvl 250 523654 5-4-5 FrmMngFuelTemp 251 523655 5-4-6 FrmMngLowPressureDiesel 252 523656 5-4-7 FrmMngRapeOilIn 253 523657 5-6-1 FrmMngRapeOilLvl 254 523658 5-6-2 FrmMngRapeOilVlv1 255 523659 5-6-3 FrmMngRapeOilVlv2 256 523660 5-6-4 FrmMngRapeOilVlv3 257 523661 5-6-5 FrmMngRapeOilVlv4 258 523662 5-6-6 FrmMngRapeOilVlv5 259 523663 5-6-7 FrmMngSTIN1RX 260 523664 5-6-8 FrmMngStEKP 261 523665 5-6-9 FrmMngStLmp 262 523666 5-7-1 FrmMngStOutRx 263 523667 5-7-2
DEUTZ A
G, VS-TA, Fi, Su Page 2 von 67 Rev. 2.0
DTC - List
Diagnosis- and Fehlercodes
Referenced ECU Software P490_: 220, 310, 501 P491_: 220, 310, 400, 501
P492_: 213 P513_: 214, 300
AirFltSysReac
Error Description
Air filter differential pressure: the pressure difference of the intake air between the filter inlet and outlet calculated by ECU is above the target range and the ECU activates a system reaction
Error Codes
DEUTZ: 11, Blink: 1-3-6, SPN: 107, FMI (Bit 0,1,2,3): 0: data valid, but above normal working area 11: Errormode not identifiable 11: Errormode not identifiable 11: Errormode not identifiable
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Pressure loss above target range with system reaction, air filter clogged or defective, sensor not working, connection cable demaged
Corrective Action
Check airfilter and if necessary clean or renew it, check cabling, check air filter and if necessary replace the filter component, check sensor and if necessary replace it, check connection cable and if necessary repair or replace it
Others Error Properties
Priority 2, self healing, as measured value a current value will be showed.
APP1
Error Description
Analog accelerator pedal sensor 1 or double accelerator pedal sensor: the voltage measured by ECU is out of the target range or the calculated pedal position is implausible compared with the position of the second pedal
Error Codes
DEUTZ: 12, Blink: 2-2-6, SPN: 91, FMI (Bit 0,1,2,3): 3: Voltage to high or short circuit to +Ubatt 4: Voltage to low or short circuit to -Ubatt 11: Errormode not identifiable 2: data stream is defective
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Voltage outside target range, signal implausible compared to signal of redundant pedal (analog pedal 1), sensor defective, connection cable demaged
Corrective Action
Check cabling, check accelator pedal sensor and if necessary replace it, check connection cable and if necessary repair or replace it
Others Error Properties
Priority 4, not self healing, as measured value a current value will be showed.
APPPwm
Error Description
Digital accelerator pedal sensor (PWM): the signal received by ECU is defective or implausible or the pulse­duty factor is out of the target range
Error Codes
DEUTZ: 14, Blink: 2-2-2, SPN: 91, FMI (Bit 0,1,2,3): 8: unusual frequency, pulse or period. 8: unusual frequency, pulse or period. 2: data stream is defective 8: unusual frequency, pulse or period.
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Duty cycle outside target range, signal erroneous or implausible (pedal 1), sensor defective, onnection cable demaged
Corrective Action
Check cabling, check accelator pedal sensor and if necessary replace it, check connection cable and if necessary repair or replace it
Others Error Properties
Priority 4, self healing, as measured value a current value will be showed.
To First Page
DEUTZ A
G, VS-TA, Fi, Su Page 3 von 67 Rev. 2.0
DTC - List
Diagnosis- and Fehlercodes
Referenced ECU Software P490_: 220, 310, 501 P491_: 220, 310, 400, 501
P492_: 213 P513_: 214, 300
APPPwmPer
Error Description
digital accelerator pedal sensor (PWM): the frequence of the signal received by ECU is out of the target range
Error Codes
DEUTZ: 15, Blink: 2-2-2, SPN: 91, FMI (Bit 0,1,2,3): 8: unusual frequency, pulse or period. 8: unusual frequency, pulse or period. 11: Errormode not identifiable 11: Errormode not identifiable
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Pulse frequency outside target range (pedal 1), sensor defective, connection cable demaged
Corrective Action
Check cabling, check accelator pedal sensor and if necessary replace it, check connection cable and if necessary repair or replace it
Others Error Properties
Priority 4, self healing, as measured value a current value will be showed.
APSCD
Error Description
Ambient air pressure sensor (in ECU): the voltage measured by ECU is out of the target range or the calculated ambient air pressure is implausible compared with the charge air pressure
Error Codes
DEUTZ: 16, Blink: 2-9-2, SPN: 108, FMI (Bit 0,1,2,3): 3: Voltage to high or short circuit to +Ubatt 4: Voltage to low or short circuit to -Ubatt 11: Errormode not identifiable 2: data stream is defective
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Ambient air pressure sensor defective, ECU defective
Corrective Action
Change ECU
Others Error Properties
Priority 4, self healing, as measured value a default value will be showed.
ArHt1
Error Description
Air heater relay: the current drain measured by ECU is out of the target range
Error Codes
DEUTZ: 17, Blink: 2-6-3, SPN: 729, FMI (Bit 0,1,2,3): 3: Voltage to high or short circuit to +Ubatt 4: Voltage to low or short circuit to -Ubatt 5: current to low or broken wire 11: Errormode not identifiable
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Cable break or short circuit at EDC output, relay defective, connection cable demaged
Corrective Action
Check cabling, if sensor not working, check relay and if necessary replace it, check connection cable and if necessary repair or replace it
Others Error Properties
Priority 2, self healing, as measured value a shutoff value will be showed.
To First Page
DEUTZ A
G, VS-TA, Fi, Su Page 4 von 67 Rev. 2.0
DTC - List
Diagnosis- and Fehlercodes
Referenced ECU Software P490_: 220, 310, 501 P491_: 220, 310, 400, 501
P492_: 213 P513_: 214, 300
ArHt2
Error Description
Air heater magnet valve: the current drain measured by ECU is out of the target range
Error Codes
DEUTZ: 18, Blink: 2-6-3, SPN: 730, FMI (Bit 0,1,2,3): 3: Voltage to high or short circuit to +Ubatt 4: Voltage to low or short circuit to -Ubatt 5: current to low or broken wire 11: Errormode not identifiable
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Cable break or short circuit, valve defective, connection cable demaged
Corrective Action
Check valve and if necessary replace it, check connection cable and if necessary repair or replace it
Others Error Properties
Priority 2, self healing, as measured value a shutoff value will be showed.
ArHtCD_NoLd
Error Description
Air heater relay: the ECU detects no switching operation at the input of a readback process
Error Codes
DEUTZ: 19, Blink: 2-6-3, SPN: 676, FMI (Bit 0,1,2,3): 11: Errormode not identifiable 4: Voltage to low or short circuit to -Ubatt 11: Errormode not identifiable 11: Errormode not identifiable
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Relay energized, but no feedback on sense line, relay defective or wrong wired, preheat component defective, connection cable demaged
Corrective Action
Check cabling of preheat component, if relay not working,check relay and if necessary replace it, check preheat component and if necessary replace it, check connection cable and if necessary repair or replace it
Others Error Properties
Priority 3, not self healing, as measured value a nominal value for output status will be showed.
ArHtCD_RlyErr
Error Description
Air heater relay: the ECU detects an implausible signal at the input of a readback process
Error Codes
DEUTZ: 20, Blink: 2-6-3, SPN: 676, FMI (Bit 0,1,2,3): 5: current to low or broken wire 2: data stream is defective 11: Errormode not identifiable 11: Errormode not identifiable
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Relay not energized, but working voltage on sense line, relay defective (can not disconnect or switch off), preheat component defective, connection cable demaged
Corrective Action
Check cabling of preheat component, if relay not working,check relay and if necessary replace it, check preheat component and if necessary replace it, check connection cable and if necessary repair or replace it
Others Error Properties
Priority 3, not self healing, as measured value a nominal value for output status will be showed.
To First Page
DEUTZ A
G, VS-TA, Fi, Su Page 5 von 67 Rev. 2.0
DTC - List
Diagnosis- and Fehlercodes
Referenced ECU Software P490_: 220, 310, 501 P491_: 220, 310, 400, 501
P492_: 213 P513_: 214, 300
BattCD
Error Description
Battery voltage: the voltage measured by ECU is out of the target range
Error Codes
DEUTZ: 22, Blink: 3-1-8, SPN: 168, FMI (Bit 0,1,2,3): 0: data valid, but above normal working area 1: data valid, but below normal working area 11: Errormode not identifiable 11: Errormode not identifiable
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Voltage below target range, battery defective, too high power supply voltage, too high contact resistance, wiring demaged, energie system overloaded, parametering inaccurate, ECU defective
Corrective Action
Check LIMA?, ECU, cabling, contact resistance, safety fuses, too high load in energy system, check battery and if necessary replace it, check battery pole and if necessary clean it, check connection cable and if necessary repair or replace it, check volta
Others Error Properties
Priority 3, self healing, as measured value a current value will be showed.
BattCDSysReac
Error Description
Battery voltage: the voltage measured by ECU is out of the target range; the ECU activates a system reaction
Error Codes
DEUTZ: 23, Blink: 3-1-8, SPN: 168, FMI (Bit 0,1,2,3): 2: data stream is defective 2: data stream is defective 11: Errormode not identifiable 11: Errormode not identifiable
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Above target range with system reaction, too high power supply voltage, parametering inaccurate, ECU defective
Corrective Action
Check dataset of calibration of working voltage for application, check LIMA? Check voltage of generator, check the parameters and if necessary correct them, replace ECU
Others Error Properties
Priority 4, self healing, as measured value a current value will be showed.
BIPCyl1
Error Description
Begin of injection of cylinder 1: the ECU can not identify the magnet valve or the injection pump with the measured value of current drain at the begin of the injection
Error Codes
DEUTZ: 24, Blink: 5-3-1, SPN: 523561, FMI (Bit 0,1,2,3): 2: data stream is defective 2: data stream is defective 2: data stream is defective 2: data stream is defective
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Value outside target range or missing (cylinder 1), magnet valve or injection pump defective
Corrective Action
Check magnetic valve or injection pump and if necessary change them
Others Error Properties
Priority 3, self healing, as measured value a current value will be showed.
To First Page
DEUTZ A
G, VS-TA, Fi, Su Page 6 von 67 Rev. 2.0
DTC - List
Diagnosis- and Fehlercodes
Referenced ECU Software P490_: 220, 310, 501 P491_: 220, 310, 400, 501
P492_: 213 P513_: 214, 300
BIPCyl2
Error Description
Begin of injection of cylinder 2: the ECU can not identify the magnet valve or the injection pump with the measured value of current drain at the begin of the injection
Error Codes
DEUTZ: 25, Blink: 5-3-2, SPN: 523562, FMI (Bit 0,1,2,3): 2: data stream is defective 2: data stream is defective 2: data stream is defective 2: data stream is defective
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Value outside target range or missing (cylinder 2), magnet valve or injection pump defective
Corrective Action
Check magnetic valve or injection pump and if necessary change them
BIPCyl3
Error Description
Begin of injection of cylinder 3: the ECU can not identify the magnet valve or the injection pump with the measured value of current drain at the begin of the injection
Error Codes
DEUTZ: 26, Blink: 5-3-3, SPN: 523563, FMI (Bit 0,1,2,3): 2: data stream is defective 2: data stream is defective 2: data stream is defective 2: data stream is defective
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Value outside target range or missing (cylinder 3), magnet valve or injection pump defective
Corrective Action
Check magnetic valve or injection pump and if necessary change them
BIPCyl4
Error Description
Begin of injection of cylinder 4: the ECU can not identify the magnet valve or the injection pump with the measured value of current drain at the begin of the injection
Error Codes
DEUTZ: 27, Blink: 5-3-4, SPN: 523564, FMI (Bit 0,1,2,3): 2: data stream is defective 2: data stream is defective 2: data stream is defective 2: data stream is defective
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Value outside target range or missing (cylinder 4), magnet valve or injection pump defective
Corrective Action
Check magnetic valve or injection pump and if necessary change them
Others Error Properties
Priority 3, self healing, as measured value a current value will be showed.
DEUTZ A
G, VS-TA, Fi, Su Page 7 von 67 Rev. 2.0
Others Error Properties
Priority 3, self healing, as measured value a current value will be showed.
Others Error Properties
Priority 3, self healing, as measured value a current value will be showed.
To First Page
DTC - List
Diagnosis- and Fehlercodes
Referenced ECU Software P490_: 220, 310, 501 P491_: 220, 310, 400, 501
P492_: 213 P513_: 214, 300
BIPCyl5
Error Description
Begin of injection of cylinder 5: the ECU can not identify the magnet valve or the injection pump with the measured value of current drain at the begin of the injection
Error Codes
DEUTZ: 28, Blink: 5-3-5, SPN: 523565, FMI (Bit 0,1,2,3): 2: data stream is defective 2: data stream is defective 2: data stream is defective 2: data stream is defective
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Value outside target range or missing (cylinder 5), magnet valve or injection pump defective
Corrective Action
Check magnetic valve or injection pump and if necessary change them
BIPCyl6
Error Description
Begin of injection of cylinder 6: the ECU can not identify the magnet valve or the injection pump with the measured value of current drain at the begin of the injection
Error Codes
DEUTZ: 29, Blink: 5-3-6, SPN: 523566, FMI (Bit 0,1,2,3): 2: data stream is defective 2: data stream is defective 2: data stream is defective 2: data stream is defective
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Value outside target range or missing (cylinder 6), magnet valve or injection pump defective
Corrective Action
Check magnetic valve or injection pump and if necessary change them
BIPCyl7
Error Description
Begin of injection of cylinder 7: the ECU can not identify the magnet valve or the injection pump with the measured value of current drain at the begin of the injection
Error Codes
DEUTZ: 30, Blink: 5-3-7, SPN: 523567, FMI (Bit 0,1,2,3): 2: data stream is defective 2: data stream is defective 2: data stream is defective 2: data stream is defective
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Value outside target range or missing (cylinder 7), magnet valve or injection pump defective
Corrective Action
Check magnetic valve or injection pump and if necessary change them
Others Error Properties
Priority 3, self healing, as measured value a current value will be showed.
DEUTZ A
G, VS-TA, Fi, Su Page 8 von 67 Rev. 2.0
Others Error Properties
Priority 3, self healing, as measured value a current value will be showed.
Others Error Properties
Priority 3, self healing, as measured value a current value will be showed.
To First Page
DTC - List
Diagnosis- and Fehlercodes
Referenced ECU Software P490_: 220, 310, 501 P491_: 220, 310, 400, 501
P492_: 213 P513_: 214, 300
BIPCyl8
Error Description
Begin of injection of cylinder 8: the ECU can not identify the magnet valve or the injection pump with the measured value of current drain at the begin of the injection
Error Codes
DEUTZ: 31, Blink: 5-3-8, SPN: 523568, FMI (Bit 0,1,2,3): 2: data stream is defective 2: data stream is defective 2: data stream is defective 2: data stream is defective
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Value outside target range or missing (cylinder 8), magnet valve or injection pump defective
Corrective Action
Check magnetic valve or injection pump and if necessary change them
Others Error Properties
Priority 3, self healing, as measured value a current value will be showed.
BPSCD
Error Description
Charge air pressure sensor: the measured voltage of sensor by ECU is out of the target range; the calculated charge air pressure is implausible or the received value via CAN is defective
Error Codes
DEUTZ: 32, Blink: 2-2-3, SPN: 102, FMI (Bit 0,1,2,3): 3: Voltage to high or short circuit to +Ubatt 4: Voltage to low or short circuit to -Ubatt 2: data stream is defective 2: data stream is defective
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Cable break or short circuit, sensor defective, onnection cable demaged
Corrective Action
Check cabling, if LDF6T sensor not working, check sensor and if necessary replace it, check connection cable and if necessary repair or replace it
Others Error Properties
Priority 4, self healing, as measured value a default value will be showed.
BPSCDSysReac
Error Description
Charge air pressure: the charge air pressure calculated by ECU is above the target range; the ECU activates a system reaction
Error Codes
DEUTZ: 33, Blink: 2-2-3, SPN: 102, FMI (Bit 0,1,2,3): 2: data stream is defective 2: data stream is defective 11: Errormode not identifiable 11: Errormode not identifiable
Error Detection
Continuous light or blink of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Outside target range with system reaction, air system demaged, sensor defective, onnection cable demaged
Corrective Action
Check air system, inspect air system and if necessary repair it, check sensor and if necessary replace it, check connection cable and if necessary repair or replace it
Others Error Properties
Priority 4, self healing, as measured value a current value will be showed.
To First Page
DEUTZ AG
, VS-TA, Fi, Su Page 9 von 67 Rev. 2.0
DTC - List
Diagnosis- and Fehlercodes
Referenced ECU Software P490_: 220, 310, 501 P491_: 220, 310, 400, 501
P492_: 213 P513_: 214, 300
CLSCDSysReac
Error Description
Coolant level: the coolant level calculated by ECU is underneath the allowed minimum
Error Codes
DEUTZ: 37, Blink: 2-3-5, SPN: 111, FMI (Bit 0,1,2,3): 1: data valid, but below normal working area 1: data valid, but below normal working area 11: Errormode not identifiable 11: Errormode not identifiable
Error Detection
Continuous light or blink of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Outside target range with system reaction, cooling system untight, sensor defective, onnection cable demaged
Corrective Action
Check coolant level, check cabling, inspect cooling system and if necessary repair it, check sensor and if necessary replace it, check connection cable and if necessary repair or replace it
CmbChbMisfire1
Error Description
Misfire at cylinder 1: the number of the misfire detected by ECU is out of the allowed limit value
Error Codes
DEUTZ: 38, Blink: 2-4-1, SPN: 1323, FMI (Bit 0,1,2,3): 12: Defective component 11: Errormode not identifiable 11: Errormode not identifiable 11: Errormode not identifiable
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Misfire detected (cylinder 1), magnet valve or injection pump defective, fuel system defective, motor engineering demaged
Corrective Action
Check magnetic valve or injection pump and if necessary replace them, check fuel system and if necessary repair it, check motor engineering and if necessary repair it
CmbChbMisfire2
Error Description
Misfire at cylinder 2: the number of the misfire detected by ECU is out of the allowed limit value
Error Codes
DEUTZ: 39, Blink: 2-4-1, SPN: 1324, FMI (Bit 0,1,2,3): 12: Defective component 11: Errormode not identifiable 11: Errormode not identifiable 11: Errormode not identifiable
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Misfire detected (cylinder 2), magnet valve or injection pump defective, fuel system defective, motor engineering demaged
Corrective Action
Check magnetic valve or injection pump and if necessary replace them, check fuel system and if necessary repair it, check motor engineering and if necessary repair it
Others Error Properties
Priority 3, not self healing, as measured value a current value will be showed.
DEUTZ A
G, VS-TA, Fi, Su Page 10 von 67 Rev. 2.0
Others Error Properties
Priority 0, not self healing, as measured value a current value will be showed.
Others Error Properties
Priority 0, not self healing, as measured value a current value will be showed.
To First Page
DTC - List
Diagnosis- and Fehlercodes
Referenced ECU Software P490_: 220, 310, 501 P491_: 220, 310, 400, 501
P492_: 213 P513_: 214, 300
CmbChbMisfire3
Error Description
Misfire at cylinder 3: the number of the misfire detected by ECU is out of the allowed limit value
Error Codes
DEUTZ: 40, Blink: 2-4-1, SPN: 1325, FMI (Bit 0,1,2,3): 12: Defective component 11: Errormode not identifiable 11: Errormode not identifiable 11: Errormode not identifiable
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Misfire detected (cylinder 3), magnet valve or injection pump defective, fuel system defective, motor engineering demaged
Corrective Action
Check magnetic valve or injection pump and if necessary replace them, check fuel system and if necessary repair it, check motor engineering and if necessary repair it
CmbChbMisfire4
Error Description
Misfire at cylinder 4: the number of the misfire detected by ECU is out of the allowed limit value
Error Codes
DEUTZ: 41, Blink: 2-4-1, SPN: 1326, FMI (Bit 0,1,2,3): 12: Defective component 11: Errormode not identifiable 11: Errormode not identifiable 11: Errormode not identifiable
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Misfire detected (cylinder 4), magnet valve or injection pump defective, fuel system defective, motor engineering demaged
Corrective Action
Check magnetic valve or injection pump and if necessary replace them, check fuel system and if necessary repair it, check motor engineering and if necessary repair it
CmbChbMisfire5
Error Description
Misfire at cylinder 5: the number of the misfire detected by ECU is out of the allowed limit value
Error Codes
DEUTZ: 42, Blink: 2-4-1, SPN: 1327, FMI (Bit 0,1,2,3): 12: Defective component 11: Errormode not identifiable 11: Errormode not identifiable 11: Errormode not identifiable
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Misfire detected (cylinder 5), magnet valve or injection pump defective, fuel system defective, motor engineering demaged
Corrective Action
Check magnetic valve or injection pump and if necessary replace them, check fuel system and if necessary repair it, check motor engineering and if necessary repair it
Others Error Properties
Priority 0, not self healing, as measured value a current value will be showed.
DEUTZ A
G, VS-TA, Fi, Su Page 11 von 67 Rev. 2.0
Others Error Properties
Priority 0, not self healing, as measured value a current value will be showed.
Others Error Properties
Priority 0, not self healing, as measured value a current value will be showed.
To First Page
DTC - List
Diagnosis- and Fehlercodes
Referenced ECU Software P490_: 220, 310, 501 P491_: 220, 310, 400, 501
P492_: 213 P513_: 214, 300
CmbChbMisfire6
Error Description
Misfire at cylinder 6: the number of the misfire detected by ECU is out of the allowed limit value
Error Codes
DEUTZ: 43, Blink: 2-4-1, SPN: 1328, FMI (Bit 0,1,2,3): 12: Defective component 11: Errormode not identifiable 11: Errormode not identifiable 11: Errormode not identifiable
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Misfire detected (cylinder 6), magnet valve or injection pump defective, fuel system defective, motor engineering demaged
Corrective Action
Check magnetic valve or injection pump and if necessary replace them, check fuel system and if necessary repair it, check motor engineering and if necessary repair it
CmbChbMisfire7
Error Description
Misfire at cylinder 7: the number of the misfire detected by ECU is out of the allowed limit value
Error Codes
DEUTZ: 44, Blink: 2-4-1, SPN: 1450, FMI (Bit 0,1,2,3): 12: Defective component 11: Errormode not identifiable 11: Errormode not identifiable 11: Errormode not identifiable
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Misfire detected (cylinder 7), magnet valve or injection pump defective, fuel system defective, motor engineering demaged
Corrective Action
Check magnetic valve or injection pump and if necessary replace them, check fuel system and if necessary repair it, check motor engineering and if necessary repair it
CmbChbMisfire8
Error Description
Misfire at cylinder 8: the number of the misfire detected by ECU is out of the allowed limit value
Error Codes
DEUTZ: 45, Blink: 2-4-1, SPN: 1451, FMI (Bit 0,1,2,3): 12: Defective component 11: Errormode not identifiable 11: Errormode not identifiable 11: Errormode not identifiable
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Misfire detected (cylinder 8), magnet valve or injection pump defective, fuel system defective, motor engineering demaged
Corrective Action
Check magnetic valve or injection pump and if necessary replace them, check fuel system and if necessary repair it, check motor engineering and if necessary repair it
Others Error Properties
Priority 0, not self healing, as measured value a current value will be showed.
DEUTZ A
G, VS-TA, Fi, Su Page 12 von 67 Rev. 2.0
Others Error Properties
Priority 0, not self healing, as measured value a current value will be showed.
Others Error Properties
Priority 0, not self healing, as measured value a current value will be showed.
To First Page
DTC - List
Diagnosis- and Fehlercodes
Referenced ECU Software P490_: 220, 310, 501 P491_: 220, 310, 400, 501
P492_: 213 P513_: 214, 300
CmbChbMisfireMul
Error Description
Misfire at more cylinders: the number of the misfire detected by ECU is out of the allowed limit value
Error Codes
DEUTZ: 46, Blink: 2-4-1, SPN: 1322, FMI (Bit 0,1,2,3): 12: Defective component 11: Errormode not identifiable 11: Errormode not identifiable 11: Errormode not identifiable
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Misfire detected, magnet valve or injection pump defective, fuel system defective, motor engineering demaged
Corrective Action
Check magnetic valve or injection pump and if necessary replace them, check fuel system and if necessary repair it, check motor engineering and if necessary repair it
Others Error Properties
Priority 0, not self healing, as measured value a current value will be showed.
CmbChbSysReac
Error Description
Misfire at more cylinders: the number of the misfire detected by ECU is out of the allowed limit value; the ECU activates a system reaction
Error Codes
DEUTZ: 47, Blink: 2-4-1, SPN: 1346, FMI (Bit 0,1,2,3): 0: data valid, but above normal working area 11: Errormode not identifiable 11: Errormode not identifiable 11: Errormode not identifiable
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Misfire detected with system reaction, magnet valve or injection pump defective, fuel system defective, motor engineering demaged
Corrective Action
Check magnetic valve or injection pump and if necessary replace them, check fuel system and if necessary repair it, check motor engineering and if necessary repair it
Others Error Properties
Priority 0, not self healing, as measured value a current value will be showed.
CoEngShOffDemIgr
Error Description
Request of engine off: the operator ignors the engine off request within an allowed period.
Error Codes
DEUTZ: 48, Blink: 3-4-1, SPN: 1109, FMI (Bit 0,1,2,3): 2: data stream is defective 11: Errormode not identifiable 11: Errormode not identifiable 11: Errormode not identifiable
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Shut-off request ignored by operator
Corrective Action
Warranty relevant
Others Error Properties
Priority 4, not self healing, as measured value a current value will be showed.
To First Page
DEUTZ A
G, VS-TA, Fi, Su Page 13 von 67 Rev. 2.0
DTC - List
Diagnosis- and Fehlercodes
Referenced ECU Software P490_: 220, 310, 501 P491_: 220, 310, 400, 501
P492_: 213 P513_: 214, 300
CRERCD
Error Description
Engine brake actuator (internal): the current drain measured by ECU is out of the target range or the maximum permissble temperature of the ECU component for power supply of the actuator is exceeded.
Error Codes
DEUTZ: 52, Blink: 5-2-8, SPN: 1072, FMI (Bit 0,1,2,3): 3: Voltage to high or short circuit to +Ubatt 4: Voltage to low or short circuit to -Ubatt 5: current to low or broken wire 11: Errormode not identifiable
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
cable break or short circuit, sensor defective, connection cable demaged
Corrective Action
Check actuator and if necessary replace it, check connection cable and if necessary repaire or replace it
Others Error Properties
Priority 2, not self healing, as measured value a nominal value for output status will be showed.
CSLpCD
Error Description
Indicator lamp of air heater relay: the current drain measured by ECU is out of the target range or the maximum permissble temperature of the ECU component for power supply of the lamp is exceeded
Error Codes
DEUTZ: 53, Blink: 3-2-8, SPN: 1081, FMI (Bit 0,1,2,3): 3: Voltage to high or short circuit to +Ubatt 4: Voltage to low or short circuit to -Ubatt 5: current to low or broken wire 2: data stream is defective
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Cable break or short circuit, lamp defective, connection cable demaged
Corrective Action
Check cabling and load, check lamp and if necessary replace it, check connection cable and if necessary repair or replace it
Others Error Properties
Priority 1, not self healing, as measured value a nominal value for output status will be showed.
CTLpCD
Error Description
Warning lamp for coolant temperature: the current drain measured by ECU is out of the target range or the maximum temperature of the ECU component for power supply of the lamp is exceeded
Error Codes
DEUTZ: 54, Blink: 1-2-3, SPN: 704, FMI (Bit 0,1,2,3): 11: Errormode not identifiable 11: Errormode not identifiable 11: Errormode not identifiable 11: Errormode not identifiable
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Cable break or short circuit, lamp defective, connection cable demaged
Corrective Action
Check cabling and load, check lamp and if necessary replace it, check connection cable and if necessary repair or replace it
Others Error Properties
Priority 1, not self healing, as measured value a nominal value for output status will be showed.
To First Page
DEUTZ A
G, VS-TA, Fi, Su Page 14 von 67 Rev. 2.0
DTC - List
Diagnosis- and Fehlercodes
Referenced ECU Software P490_: 220, 310, 501 P491_: 220, 310, 400, 501
P492_: 213 P513_: 214, 300
CTSCD
Error Description
Coolant temperature sensor: the voltage of the sensor measured by ECU is out of the target range; the coolant temperature calculated by ECU is implausible compared with the oil temperature or the received value via CAN is defective
Error Codes
DEUTZ: 55, Blink: 2-2-5, SPN: 110, FMI (Bit 0,1,2,3): 3: Voltage to high or short circuit to +Ubatt 4: Voltage to low or short circuit to -Ubatt 2: data stream is defective 2: data stream is defective
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Cable break or short circuit, lamp defective, connection cable demaged
Corrective Action
Check cabling, sensor defect, check sensor and if necessary replace it, check connection cable and if necessary repair or replace it
Others Error Properties
Priority 4, self healing, as measured value a default value will be showed.
CTSCDSysReac
Error Description
Coolant temperature: the coolant temperature calculated by ECU is above the target range; the ECU activates a system reaction
Error Codes
DEUTZ: 56, Blink: 2-3-2, SPN: 110, FMI (Bit 0,1,2,3): 0: data valid, but above normal working area 0: data valid, but above normal working area 11: Errormode not identifiable 11: Errormode not identifiable
Error Detection
Continuous light or blink of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Outside target range with system reaction, cooling system not enough to be filled, clogged or demaged, cooling compressor dropped out, sensor defective, onnection cable demaged
Corrective Action
Check cycle cooling system and compressor, inspect cooling system and if necessary repair it, check cooling compressor and if necessary replace it, check sensor and if necessary replace it, check connection cable and if necessary repair or replace it
Others Error Properties
Priority 4, self healing, as measured value a current value will be showed.
Dummy1CD_Max
Error Description
Reserve output 1: the ECU detects a short circuit to battery
Error Codes
DEUTZ: 57, Blink: 1-0-0, SPN: 701, FMI (Bit 0,1,2,3): 11: Errormode not identifiable 11: Errormode not identifiable 11: Errormode not identifiable 11: Errormode not identifiable
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Short circuit to Ubatt (output 1), connection cable demaged
Corrective Action
Check connection cable and if necessary repair or replace it
Others Error Properties
Priority 1, not self healing, as measured value a shutoff value will be showed.
To First Page
DEUTZ A
G, VS-TA, Fi, Su Page 15 von 67 Rev. 2.0
DTC - List
Diagnosis- and Fehlercodes
Referenced ECU Software P490_: 220, 310, 501 P491_: 220, 310, 400, 501
P492_: 213 P513_: 214, 300
Dummy1CD_Min
Error Description
Reserve output 1: the ECU detects a short circuit to ground
Error Codes
DEUTZ: 58, Blink: 1-0-0, SPN: 701, FMI (Bit 0,1,2,3): 11: Errormode not identifiable 11: Errormode not identifiable 11: Errormode not identifiable 11: Errormode not identifiable
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Short circuit to ground (output 1), connection cable demaged
Corrective Action
Check connection cable and if necessary repair or replace it
Others Error Properties
Priority 1, not self healing, as measured value a shutoff value will be showed.
Dummy1CD_SigNpl
Error Description
Reserve output 1: the ECU detects no load or excess temperature of the ECU component for power supply of the connected components
Error Codes
DEUTZ: 59, Blink: 1-0-0, SPN: 701, FMI (Bit 0,1,2,3): 11: Errormode not identifiable 11: Errormode not identifiable 11: Errormode not identifiable 11: Errormode not identifiable
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Cable break or ECU internal error (output 1), connection cable demaged, connected components defective, parametering of the output inaccurate, ECU defective
Corrective Action
Check connection cable and if necessary repair or replace it, check parameters and if necessary correct it, replace ECU
Others Error Properties
Priority 1, not self healing, as measured value a shutoff value will be showed.
Dummy2CD_Max
Error Description
Reserve output 2: the ECU detects a short circuit to battery
Error Codes
DEUTZ: 60, Blink: 1-0-0, SPN: 702, FMI (Bit 0,1,2,3): 11: Errormode not identifiable 11: Errormode not identifiable 11: Errormode not identifiable 11: Errormode not identifiable
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Short circuit to Ubatt (output 2), onnection cable demaged
Corrective Action
Check connection cable and if necessary repair or replace it
Others Error Properties
Priority 1, not self healing, as measured value a shutoff value will be showed.
To First Page
DEUTZ A
G, VS-TA, Fi, Su Page 16 von 67 Rev. 2.0
DTC - List
Diagnosis- and Fehlercodes
Referenced ECU Software P490_: 220, 310, 501 P491_: 220, 310, 400, 501
P492_: 213 P513_: 214, 300
Dummy2CD_Min
Error Description
Reserve output 2: the ECU detects a short circuit to ground
Error Codes
DEUTZ: 61, Blink: 1-0-0, SPN: 702, FMI (Bit 0,1,2,3): 11: Errormode not identifiable 11: Errormode not identifiable 11: Errormode not identifiable 11: Errormode not identifiable
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Short circuit to ground (output 2), connection cable demaged
Corrective Action
Check connection cable and if necessary repair or replace it
Others Error Properties
Priority 1, not self healing, as measured value a shutoff value will be showed.
Dummy2CD_SigNpl
Error Description
Reserve output 2: the ECU detects no load or excess temperature of the ECU component for power supply of the connected components
Error Codes
DEUTZ: 62, Blink: 1-0-0, SPN: 702, FMI (Bit 0,1,2,3): 11: Errormode not identifiable 11: Errormode not identifiable 11: Errormode not identifiable 11: Errormode not identifiable
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Cable break or ECU internal error (output 2), connection cable demaged, connected components defective, parametering of the output inaccurate, ECU defective
Corrective Action
Check connection cable and if necessary repair or replace it, check parameters and if necessary correct it, replace ECU
Others Error Properties
Priority 1, not self healing, as measured value a shutoff value will be showed.
EGRCD_Max
Error Description
Actuator of the external EGR valve: the ECU detects a short circuit to battery
Error Codes
DEUTZ: 69, Blink: 4-1-4, SPN: 2791, FMI (Bit 0,1,2,3): 3: Voltage to high or short circuit to +Ubatt 11: Errormode not identifiable 11: Errormode not identifiable 11: Errormode not identifiable
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Short circuit to Ubatt, connection cable demaged
Corrective Action
Check cabling, sensor defect, check sensor and if necessary replace it, check connection cable and if necessary repair or replace it
Others Error Properties
Priority 3, not self healing, as measured value a shutoff value will be showed.
To First Page
DEUTZ A
G, VS-TA, Fi, Su Page 17 von 67 Rev. 2.0
DTC - List
Diagnosis- and Fehlercodes
Referenced ECU Software P490_: 220, 310, 501 P491_: 220, 310, 400, 501
P492_: 213 P513_: 214, 300
EGRCD_Min
Error Description
Actuator of the external EGR valve: the ECU detects a short circuit to ground
Error Codes
DEUTZ: 70, Blink: 4-1-4, SPN: 2791, FMI (Bit 0,1,2,3): 11: Errormode not identifiable 4: Voltage to low or short circuit to -Ubatt 11: Errormode not identifiable 11: Errormode not identifiable
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Short circuit to ground, connection cable demaged
Corrective Action
Check cabling, sensor defect, check sensor and if necessary replace it, check connection cable and if necessary repair or replace it
Others Error Properties
Priority 3, not self healing, as measured value a shutoff value will be showed.
EGRCD_SigNpl
Error Description
Actuator of the external EGR valve: the ECU detects no load or excess temperature of the ECU component for power supply of the connected components
Error Codes
DEUTZ: 71, Blink: 4-1-5, SPN: 2791, FMI (Bit 0,1,2,3): 11: Errormode not identifiable 11: Errormode not identifiable 5: current to low or broken wire 2: data stream is defective
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Cable break or excess temperature, sensor defective, connection cable demaged
Corrective Action
Check cabling, sensor defect, check sensor and if necessary replace it, check connection cable and if necessary repair or replace it
Others Error Properties
Priority 3, not self healing, as measured value a shutoff value will be showed.
EGRCDIntEGR
Error Description
Actuator of the internal EGR valve: the ECU detects no load or excess temperature of the ECU component for power supply of the actuator
Error Codes
DEUTZ: 72, Blink: 4-1-6, SPN: 2791, FMI (Bit 0,1,2,3): 3: Voltage to high or short circuit to +Ubatt 4: Voltage to low or short circuit to -Ubatt 5: current to low or broken wire 2: data stream is defective
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Cable break, short circuit or excess temperature, sensor defective, connection cable demaged
Corrective Action
Check cabling, sensor defect, check sensor and if necessary replace it, check connection cable and if necessary repair or replace it
Others Error Properties
Priority 3, not self healing, as measured value a shutoff value will be showed.
To First Page
DEUTZ A
G, VS-TA, Fi, Su Page 18 von 67 Rev. 2.0
DTC - List
Diagnosis- and Fehlercodes
Referenced ECU Software P490_: 220, 310, 501 P491_: 220, 310, 400, 501
P492_: 213 P513_: 214, 300
EngCDTrqCalcOut
Error Description
Output with PWM signal of the engine power: the current drain measured by ECU is out of the target range or the maximum permissible temperature of the ECU component to control the output is exceeded
Error Codes
DEUTZ: 74, Blink: 5-5-5, SPN: 923, FMI (Bit 0,1,2,3): 3: Voltage to high or short circuit to +Ubatt 4: Voltage to low or short circuit to -Ubatt 5: current to low or broken wire 2: data stream is defective
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Engine Power output: cable break or short circuit, output defective, connection cable demaged
Corrective Action
Check cabling, sensor defect, check sensor and if necessary replace it, check connection cable and if necessary repair or replace it
Others Error Properties
Priority 1, not self healing, as measured value a shutoff value will be showed.
EngMBackUp
Error Description
Crankschaft speed sensor: the ECU receives no signal and uses the signal from camschaft speed sensor as alternative to calculate the engine speed
Error Codes
DEUTZ: 75, Blink: 2-1-2, SPN: 190, FMI (Bit 0,1,2,3): 11: Errormode not identifiable 12: Defective component 11: Errormode not identifiable 11: Errormode not identifiable
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Engine running only with cam-shaft speed signal, transmitter defective, connection cable demaged
Corrective Action
Check cabling of crankschaft sensor, check crankschaft sensor and if necessary replace it, check connection cable and if necessary repair or replace it
Others Error Properties
Priority 3, self healing, as measured value a - will be showed.
EngMCaS1
Error Description
Camschaft speed sensor: the ECU receives no signal or the signal is defective
Error Codes
DEUTZ: 76, Blink: 2-1-2, SPN: 190, FMI (Bit 0,1,2,3): 12: Defective component 8: unusual frequency, pulse or period. 11: Errormode not identifiable 11: Errormode not identifiable
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Speed signal from cam-shaft defectiveiv or missing, transmitter defective, connection cable demaged, parametering of the sensor wheel inaccurate
Corrective Action
Check cabling, check camschaft sensor and if necessary replace it, check configuration of sensor wheel, check connection cable and if necessary repair or replace it, check parameters and if necessary correct them
Others Error Properties
Priority 4, self healing, as measured value a 0 will be showed.
To First Page
DEUTZ A
G, VS-TA, Fi, Su Page 19 von 67 Rev. 2.0
DTC - List
Diagnosis- and Fehlercodes
Referenced ECU Software P490_: 220, 310, 501 P491_: 220, 310, 400, 501
P492_: 213 P513_: 214, 300
EngMCrS1
Error Description
Crankschaft speed sensor: the ECU receives no signal or the signal is defective
Error Codes
DEUTZ: 77, Blink: 2-1-2, SPN: 190, FMI (Bit 0,1,2,3): 12: Defective component 8: unusual frequency, pulse or period. 11: Errormode not identifiable 11: Errormode not identifiable
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Speed signal from crankshaft defectiveiv or missing, transmitter defective, connection cable demaged, sensor wheel installed inaccurately
Corrective Action
Check cabling, check camschaft sensor and if necessary replace it, check configuration of sensor wheel, check connection cable and if necessary repair or replace it, check the position of sensor wheel and if necessary correct it
Others Error Properties
Priority 4, self healing, as measured value a 0 will be showed.
EngMOfsCaSCrS
Error Description
Speed sensor of crankschaft and camschaft: the received signals are out of phase
Error Codes
DEUTZ: 78, Blink: 2-1-3, SPN: 190, FMI (Bit 0,1,2,3): 2: data stream is defective 11: Errormode not identifiable 11: Errormode not identifiable 11: Errormode not identifiable
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Speed signals of crank-shaft and cam-shaft are phase­shifted, sensor wheel installed in wrong position, sensor wrong wired
Corrective Action
Check position from crankschaft sensor wheel to camschaft sensor wheel, polarisation crankschaft or camschaft sensor, check position of sensor wheel and if necessary correct it, check cabling and if necessary correct it
Others Error Properties
Priority 4, not self healing, as measured value a - will be showed.
EngPrtSysReacFOC
Error Description
Engine speed: the engine speed calculated by ECU is above the target range; the ECU activates a system reaction
Error Codes
DEUTZ: 79, Blink: 2-1-4, SPN: 190, FMI (Bit 0,1,2,3): 0: data valid, but above normal working area 11: Errormode not identifiable 11: Errormode not identifiable 11: Errormode not identifiable
Error Detection
Blink of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Engine overspeed detected with system reaction, maximum engine speed exceeded
Corrective Action
Others Error Properties
Priority 5, not self healing, as measured value a current value will be showed.
To First Page
DEUTZ A
G, VS-TA, Fi, Su Page 20 von 67 Rev. 2.0
DTC - List
Diagnosis- and Fehlercodes
Referenced ECU Software P490_: 220, 310, 501 P491_: 220, 310, 400, 501
P492_: 213 P513_: 214, 300
EngPrtSysReacORC
Error Description
Engine speed: under overrun conditions, the engine speed calculated by ECU is above the target range; the ECU activates a system reaction
Error Codes
DEUTZ: 80, Blink: 2-1-4, SPN: 190, FMI (Bit 0,1,2,3): 14: Special Instructions 11: Errormode not identifiable 11: Errormode not identifiable 11: Errormode not identifiable
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Overrun conditions detected with system reaction, maximum engine speed exceeded
Corrective Action
Others Error Properties
Priority 4, self healing, as measured value a current value will be showed.
ESLpCD
Error Description
Indicator lamp for engine running: the current drain measured by ECU is out of the target range or the maximum permissible temperature of the ECU component for power supply of the lamp is exceeded
Error Codes
DEUTZ: 81, Blink: 1-4-2, SPN: 703, FMI (Bit 0,1,2,3): 3: Voltage to high or short circuit to +Ubatt 4: Voltage to low or short circuit to -Ubatt 5: current to low or broken wire 2: data stream is defective
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Cable break or internal ECU error, lamp defective, connection cable demaged
Corrective Action
Check cabling and load, check lamp and if necessary replace it, check connection cable and if necessary repair or replace it
Others Error Properties
Priority 1, not self healing, as measured value a shutoff value will be showed.
ExFlCD
Error Description
Engine brake flap actuator: the current drain measured by ECU is out of the target range or the maximum permissible temperature of the ECU component for power supply of the actuator is exceeded
Error Codes
DEUTZ: 82, Blink: 2-1-9, SPN: 1074, FMI (Bit 0,1,2,3): 3: Voltage to high or short circuit to +Ubatt 4: Voltage to low or short circuit to -Ubatt 5: current to low or broken wire 11: Errormode not identifiable
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Engine brake flap actuator: cable break or short circuit, sensor defective, connection cable demaged
Corrective Action
Check cabling, sensor defect, check sensor and if necessary replace it, check connection cable and if necessary repair or replace it
Others Error Properties
Priority 2, not self healing, as measured value a shutoff value will be showed.
To First Page
DEUTZ A
G, VS-TA, Fi, Su Page 21 von 67 Rev. 2.0
DTC - List
Diagnosis- and Fehlercodes
Referenced ECU Software P490_: 220, 310, 501 P491_: 220, 310, 400, 501
P492_: 213 P513_: 214, 300
FanCD
Error Description
Fan power stage: the current drain measured by ECU is out of the target range or the maximum permissible temperature of the ECU component for power supply of the actuator is exceeded
Error Codes
DEUTZ: 83, Blink: 2-3-8, SPN: 975, FMI (Bit 0,1,2,3): 3: Voltage to high or short circuit to +Ubatt 4: Voltage to low or short circuit to -Ubatt 5: current to low or broken wire 2: data stream is defective
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
cable break or short circuit, sensor defective, connection cable demaged
Corrective Action
Check cabling, sensor defect, check sensor and if necessary replace it, check connection cable and if necessary repair or replace it
Others Error Properties
Priority 2, not self healing, as measured value a nominal value will be showed.
FanCDEval
Error Description
Fan speed sensor: the current drain measured by ECU is out of the target range
Error Codes
DEUTZ: 85, Blink: 2-3-8, SPN: 1639, FMI (Bit 0,1,2,3): 3: Voltage to high or short circuit to +Ubatt 4: Voltage to low or short circuit to -Ubatt 11: Errormode not identifiable 11: Errormode not identifiable
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Sensor defective, connection cable demaged, fan speed outside the target range
Corrective Action
Check sensor and if necessary replace it, check connectionn cable and if necessary repair or replace it, check fan
Others Error Properties
Priority 2, self healing, as measured value a current value will be showed.
FanCDSysReac
Error Description
Fan speed: the fan speed calculated by ECU is above the target range; the ECU activates a system reaction
Error Codes
DEUTZ: 86, Blink: 2-3-8, SPN: 523602, FMI (Bit 0,1,2,3): 2: data stream is defective 2: data stream is defective 11: Errormode not identifiable 11: Errormode not identifiable
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Above target range with system reaction
Corrective Action
Others Error Properties
Priority 3, self healing, as measured value a current value will be showed.
To First Page
DEUTZ A
G, VS-TA, Fi, Su Page 22 von 67 Rev. 2.0
DTC - List
Diagnosis- and Fehlercodes
Referenced ECU Software P490_: 220, 310, 501 P491_: 220, 310, 400, 501
P492_: 213 P513_: 214, 300
FlFCD
Error Description
Fuel filter water level sensor: the voltage of sensor measured by ECU is out of the target range
Error Codes
DEUTZ: 87, Blink: 2-2-8, SPN: 97, FMI (Bit 0,1,2,3): 3: Voltage to high or short circuit to +Ubatt 4: Voltage to low or short circuit to -Ubatt 11: Errormode not identifiable 11: Errormode not identifiable
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
cable break or short circuit, sensor defective, connection cable demaged
Corrective Action
Check cabling, if sensor not working, check sensor and if necessary replace it, check connection cable and if necessary repair or replace it
Others Error Properties
Priority 1, self healing, as measured value a default value will be showed.
FlFCD_WtLvl
Error Description
Water in fuel: the water level calculated by ECU is above the allowed limit value
Error Codes
DEUTZ: 89, Blink: 2-2-8, SPN: 97, FMI (Bit 0,1,2,3): 12: Defective component 11: Errormode not identifiable 11: Errormode not identifiable 11: Errormode not identifiable
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Above target range, excess of maximum permissible water level in fuel filter
Corrective Action
flush water seperator
Others Error Properties
Priority 3, not self healing, as measured value a current value will be showed.
FlPSCD
Error Description
Low fuel pressure sensor: the voltage of sensor measured by ECU is out of the target range
Error Codes
DEUTZ: 90, Blink: 2-1-6, SPN: 94, FMI (Bit 0,1,2,3): 3: Voltage to high or short circuit to +Ubatt 4: Voltage to low or short circuit to -Ubatt 11: Errormode not identifiable 11: Errormode not identifiable
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
cable break or short circuit, sensor defective, connection cable demaged
Corrective Action
Check cabling, if sensor not working, check sensor and if necessary replace it, check connection cable and if necessary repair or replace it
Others Error Properties
Priority 3, self healing, as measured value a default value will be showed.
To First Page
DEUTZ A
G, VS-TA, Fi, Su Page 23 von 67 Rev. 2.0
DTC - List
Diagnosis- and Fehlercodes
Referenced ECU Software P490_: 220, 310, 501 P491_: 220, 310, 400, 501
P492_: 213 P513_: 214, 300
FlPSCDSysReac
Error Description
Low fuel pressure: the low fuel pressure calculated by ECU is underneath the target range; the ECU activates a system reaction
Error Codes
DEUTZ: 91, Blink: 2-1-6, SPN: 94, FMI (Bit 0,1,2,3): 2: data stream is defective 2: data stream is defective 11: Errormode not identifiable 11: Errormode not identifiable
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Below target range with system reaction, interruption in cycling process of low fuel pressure (for example, fuel pump defective), sensor defective, connection cable demaged
Corrective Action
Check low fuel pressure loop system, Check fuel pump, inspect fuel system and if necessary repair it, check sensor and if necessary replace it, check connection cable and if necessary repair or replace it
Others Error Properties
Priority 3, self healing, as measured value a current value will be showed.
FrmMngDecV1
Error Description
CAN message DecV1 (Pseudo Pedal): the message can not be received by ECU or the received value is above the target range
Error Codes
DEUTZ: 94, Blink: 5-2-6, SPN: 523239, FMI (Bit 0,1,2,3): 12: Defective component 12: Defective component 12: Defective component 2: data stream is defective
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Missing or value above target range (message "DecV1" = pseudo pedal), CAN bus wrong cabled, wiring is demaged, receiver (sender of the message) work inaccurately, parametering inaccurate
Corrective Action
Check CAN Bus cabling (Bus sheduling, polarity, short circuit, power interrupt), test protocol of receiver, check CAN functional range
Others Error Properties
Priority 1, self healing, as measured value a default value will be showed.
FrmMngFunModCtl
Error Description
CAN message FunModCtl (Function Mode Control): the message can not be received by ECU
Error Codes
DEUTZ: 95, Blink: 5-2-7, SPN: 523240, FMI (Bit 0,1,2,3): 12: Defective component 11: Errormode not identifiable 11: Errormode not identifiable 11: Errormode not identifiable
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Missing message "FunModCtl" = function mode control, CAN bus wrong cabled, wiring is demaged, receiver (sender of the message) work inaccurately, parametering inaccurate
Corrective Action
Check CAN Bus cabling (Bus sheduling, polarity, short circuit, power interrupt), test protocol of receiver, check CAN functional range
Others Error Properties
Priority 1, self healing, as measured value a default value will be showed.
To First Page
DEUTZ A
G, VS-TA, Fi, Su Page 24 von 67 Rev. 2.0
DTC - List
Diagnosis- and Fehlercodes
Referenced ECU Software P490_: 220, 310, 501 P491_: 220, 310, 400, 501
P492_: 213 P513_: 214, 300
FrmMngTOEngPrt
Error Description
CAN message EngPrt (Engine Protection): the message can not be received by ECU
Error Codes
DEUTZ: 106, Blink: 3-3-3, SPN: 523212, FMI (Bit 0,1,2,3): 12: Defective component 11: Errormode not identifiable 12: Defective component 11: Errormode not identifiable
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Missing message "EngPrt" = engine protection, CAN bus wrong cabled, wiring is demaged, receiver (sender of the message) work inaccurately, parametering inaccurate
Corrective Action
Check CAN Bus cabling (Bus sheduling, polarity, short circuit, power interrupt), test protocol of receiver, check CAN functional range
Others Error Properties
Priority 1, self healing, as measured value a default value will be showed.
FrmMngTOPrHtEnCmd
Error Description
CAN message PrHtEnCmd (Preheat and Engine Command): the message received can not be received by ECU
Error Codes
DEUTZ: 110, Blink: 3-3-7, SPN: 523216, FMI (Bit 0,1,2,3): 11: Errormode not identifiable 11: Errormode not identifiable 12: Defective component 11: Errormode not identifiable
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Missing message "PrHtEnCmd" = preheat and engine command; CAN bus wrong cabled, wiring is demaged, receiver (sender of the message) work inaccurately, parametering inaccurate
Corrective Action
Check CAN Bus cabling (Bus sheduling, polarity, short circuit, power interrupt), test protocol of receiver, check CAN functional range
Others Error Properties
Priority 1, self healing, as measured value a default value will be showed.
FrmMngTORxCCVS
Error Description
CAN message RxCCVS (Cruise Control): the message can not be received by ECU
Error Codes
DEUTZ: 112, Blink: 1-1-1, SPN: 523218, FMI (Bit 0,1,2,3): 11: Errormode not identifiable 11: Errormode not identifiable 12: Defective component 11: Errormode not identifiable
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Missing message "RxCCVS" = cruise control; CAN bus wrong cabled, wiring is demaged, receiver (sender of the message) work inaccurately, parametering inaccurate
Corrective Action
Check CAN Bus cabling (Bus sheduling, polarity, short circuit, power interrupt), test protocol of receiver, check CAN functional range
Others Error Properties
Priority 1, self healing, as measured value a default value will be showed.
To First Page
DEUTZ A
G, VS-TA, Fi, Su Page 25 von 67 Rev. 2.0
DTC - List
Diagnosis- and Fehlercodes
Referenced ECU Software P490_: 220, 310, 501 P491_: 220, 310, 400, 501
P492_: 213 P513_: 214, 300
FrmMngTORxEngTemp
Error Description
CAN message RxEngTemp (Engine Temperature): the message can not be received by ECU
Error Codes
DEUTZ: 113, Blink: 1-1-2, SPN: 523604, FMI (Bit 0,1,2,3): 12: Defective component 11: Errormode not identifiable 11: Errormode not identifiable 11: Errormode not identifiable
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Missing message "RxEngTemp" = engine temperature, CAN bus wrong cabled, wiring is demaged, receiver (sender of the message) work inaccurately, parametering inaccurate
Corrective Action
Check CAN Bus cabling (Bus sheduling, polarity, short circuit, power interrupt), test protocol of receiver, check CAN functional range
Others Error Properties
Priority 1, self healing, as measured value a default value will be showed.
FrmMngTOSwtOut
Error Description
CAN message SwtOut (Switching Output): the message can not be received by ECU
Error Codes
DEUTZ: 117, Blink: 1-1-5, SPN: 523238, FMI (Bit 0,1,2,3): 12: Defective component 11: Errormode not identifiable 11: Errormode not identifiable 11: Errormode not identifiable
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Missing message "SwtOut" = switch outputs, CAN bus wrong cabled, wiring is demaged, receiver (sender of the message) work inaccurately, parametering inaccurate
Corrective Action
Check CAN Bus cabling (Bus sheduling, polarity, short circuit, power interrupt), test protocol of receiver, check CAN functional range
Others Error Properties
Priority 1, self healing, as measured value a default value will be showed.
FrmMngTOTCO1
Error Description
CAN message "TCO1" (Speedo Signal): the message can not be received by ECU
Error Codes
DEUTZ: 118, Blink: 1-1-6, SPN: 523222, FMI (Bit 0,1,2,3): 11: Errormode not identifiable 11: Errormode not identifiable 12: Defective component 11: Errormode not identifiable
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Missing message "TCO1" = speedo signal, CAN bus wrong cabled, wiring is demaged, receiver (sender of the message) work inaccurately, parametering inaccurate
Corrective Action
Check CAN Bus cabling (Bus sheduling, polarity, short circuit, power interrupt), test protocol of receiver, check CAN functional range
Others Error Properties
Priority 1, self healing, as measured value a default value will be showed.
To First Page
DEUTZ A
G, VS-TA, Fi, Su Page 26 von 67 Rev. 2.0
DTC - List
Diagnosis- and Fehlercodes
Referenced ECU Software P490_: 220, 310, 501 P491_: 220, 310, 400, 501
P492_: 213 P513_: 214, 300
FrmMngTOTSC1AE
Error Description
CAN message TSC1-AE (Torque/Speed Control #1 from Automatic Traction Control to Engine): the message can not be received by ECU
Error Codes
DEUTZ: 120, Blink: 1-1-8, SPN: 523605, FMI (Bit 0,1,2,3): 12: Defective component 12: Defective component 11: Errormode not identifiable 11: Errormode not identifiable
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Missing message "TSC1-AE", CAN bus wrong cabled, wiring is demaged, receiver (sender of the message) work inaccurately, parametering inaccurate
Corrective Action
Check CAN Bus cabling (Bus sheduling, polarity, short circuit, power interrupt), test protocol of receiver, check CAN functional range
FrmMngTOTSC1AR
Error Description
CAN message TSC1-AR (Torque/Speed Control #1 from Automatic Traction Control to Retarder): the message can not be received by ECU
Error Codes
DEUTZ: 121, Blink: 1-1-9, SPN: 523606, FMI (Bit 0,1,2,3): 12: Defective component 12: Defective component 11: Errormode not identifiable 11: Errormode not identifiable
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Missing message "TSC1-AR", CAN bus wrong cabled, wiring is demaged, receiver (sender of the message) work inaccurately, parametering inaccurate
Corrective Action
Check CAN Bus cabling (Bus sheduling, polarity, short circuit, power interrupt), test protocol of receiver, check CAN functional range
FrmMngTOTSC1DE
Error Description
CAN message TSC1-DE (Torque/Speed Control #1 from Driveline to Engine): the message can not be received by ECU
Error Codes
DEUTZ: 122, Blink: 1-1-8, SPN: 523607, FMI (Bit 0,1,2,3): 12: Defective component 12: Defective component 11: Errormode not identifiable 11: Errormode not identifiable
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Missing message "TSC1-DE", CAN bus wrong cabled, wiring is demaged, receiver (sender of the message) work inaccurately, parametering inaccurate
Corrective Action
Check CAN Bus cabling (Bus sheduling, polarity, short circuit, power interrupt), test protocol of receiver, check CAN functional range
Others Error Properties
Priority 1, not self healing, as measured value a default value will be showed.
DEUTZ A
G, VS-TA, Fi, Su Page 27 von 67 Rev. 2.0
Others Error Properties
Priority 1, not self healing, as measured value a default value will be showed.
Others Error Properties
Priority 1, not self healing, as measured value a default value will be showed.
To First Page
DTC - List
Diagnosis- and Fehlercodes
Referenced ECU Software P490_: 220, 310, 501 P491_: 220, 310, 400, 501
P492_: 213 P513_: 214, 300
FrmMngTOTSC1DR
Error Description
CAN message TSC1-DR (Torque/Speed Control #1 from Driveline to Retarder): the message can not be received by ECU
Error Codes
DEUTZ: 123, Blink: 1-1-9, SPN: 523608, FMI (Bit 0,1,2,3): 12: Defective component 12: Defective component 11: Errormode not identifiable 11: Errormode not identifiable
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Missing message "TSC1-DR", CAN bus wrong cabled, wiring is demaged, receiver (sender of the message) work inaccurately, parametering inaccurate
Corrective Action
Check CAN Bus cabling (Bus sheduling, polarity, short circuit, power interrupt), test protocol of receiver, check CAN functional range
FrmMngTOTSC1PE
Error Description
CAN message TSC1-PE (Torque/Speed Control #1 from Power Take Off to Engine): the message can not be received by ECU
Error Codes
DEUTZ: 124, Blink: 1-1-8, SPN: 523609, FMI (Bit 0,1,2,3): 12: Defective component 12: Defective component 11: Errormode not identifiable 11: Errormode not identifiable
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Missing message "TSC1-PE", CAN bus wrong cabled, wiring is demaged, receiver (sender of the message) work inaccurately, parametering inaccurate
Corrective Action
Check CAN Bus cabling (Bus sheduling, polarity, short circuit, power interrupt), test protocol of receiver, check CAN functional range
FrmMngTOTSC1TE
Error Description
CAN message TSC1-TE (Torque/Speed Control #1 from Traction Control to Engine): the message can not be received by ECU
Error Codes
DEUTZ: 125, Blink: 1-1-8, SPN: 898, FMI (Bit 0,1,2,3): 12: Defective component 12: Defective component 11: Errormode not identifiable 11: Errormode not identifiable
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Missing message "TSC1-TE", CAN bus wrong cabled, wiring is demaged, receiver (sender of the message) work inaccurately, parametering inaccurate
Corrective Action
Check CAN Bus cabling (Bus sheduling, polarity, short circuit, power interrupt), test protocol of receiver, check CAN functional range
Others Error Properties
Priority 1, not self healing, as measured value a default value will be showed.
DEUTZ A
G, VS-TA, Fi, Su Page 28 von 67 Rev. 2.0
Others Error Properties
Priority 1, not self healing, as measured value a default value will be showed.
Others Error Properties
Priority 1, not self healing, as measured value a default value will be showed.
To First Page
DTC - List
Diagnosis- and Fehlercodes
Referenced ECU Software P490_: 220, 310, 501 P491_: 220, 310, 400, 501
P492_: 213 P513_: 214, 300
FrmMngTOTSC1TR
Error Description
CAN message TSC1-TR (Torque/Speed Control #1 from Traction Control to Retarder): the message can not be received by ECU
Error Codes
DEUTZ: 126, Blink: 1-1-9, SPN: 520, FMI (Bit 0,1,2,3): 12: Defective component 12: Defective component 11: Errormode not identifiable 11: Errormode not identifiable
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Missing message "TSC1-TR", CAN bus wrong cabled, wiring is demaged, receiver (sender of the message) work inaccurately, parametering inaccurate
Corrective Action
Check CAN Bus cabling (Bus sheduling, polarity, short circuit, power interrupt), test protocol of receiver, check CAN functional range
FrmMngTOTSC1VE
Error Description
CAN message TSC1-VE (Torque/Speed Control #1 from Vehicle Control to Engine): the message can not be received by ECU
Error Codes
DEUTZ: 127, Blink: 1-1-8, SPN: 523610, FMI (Bit 0,1,2,3): 12: Defective component 12: Defective component 11: Errormode not identifiable 11: Errormode not identifiable
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Missing message "TSC1-VE", CAN bus wrong cabled, wiring is demaged, receiver (sender of the message) work inaccurately, parametering inaccurate
Corrective Action
Check CAN Bus cabling (Bus sheduling, polarity, short circuit, power interrupt), test protocol of receiver, check CAN functional range
FrmMngTOTSC1VR
Error Description
CAN message TSC1-VR (Torque/Speed Control #1 from Vehicle Control to Retarder): the message can not be received by ECU
Error Codes
DEUTZ: 128, Blink: 1-1-9, SPN: 523611, FMI (Bit 0,1,2,3): 12: Defective component 12: Defective component 11: Errormode not identifiable 11: Errormode not identifiable
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Missing message "TSC1-VR", CAN bus wrong cabled, wiring is demaged, receiver (sender of the message) work inaccurately, parametering inaccurate
Corrective Action
Check CAN Bus cabling (Bus sheduling, polarity, short circuit, power interrupt), test protocol of receiver, check CAN functional range
Others Error Properties
Priority 1, not self healing, as measured value a default value will be showed.
DEUTZ A
G, VS-TA, Fi, Su Page 29 von 67 Rev. 2.0
Others Error Properties
Priority 1, not self healing, as measured value a default value will be showed.
Others Error Properties
Priority 1, not self healing, as measured value a default value will be showed.
To First Page
DTC - List
Diagnosis- and Fehlercodes
Referenced ECU Software P490_: 220, 310, 501 P491_: 220, 310, 400, 501
P492_: 213 P513_: 214, 300
FrmMngTxTO
Error Description
CAN message: the ECU detects a timeout for one or more posted message
Error Codes
DEUTZ: 131, Blink: 2-7-1, SPN: 523500, FMI (Bit 0,1,2,3): 11: Errormode not identifiable 11: Errormode not identifiable 12: Defective component 11: Errormode not identifiable
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Timeout for sent messages
Corrective Action
Others Error Properties
Priority 1, self healing, as measured value a - will be showed.
FTSCD
Error Description
Fuel temperature sensor: the voltage measured by ECU is out of the target range
Error Codes
DEUTZ: 133, Blink: 2-2-7, SPN: 174, FMI (Bit 0,1,2,3): 3: Voltage to high or short circuit to +Ubatt 4: Voltage to low or short circuit to -Ubatt 11: Errormode not identifiable 11: Errormode not identifiable
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Fuel temp. sensor: cable break or short circuit, sendor defective, connection cable demaged
Corrective Action
Check cabling, if sensor not working, check sensor and if necessary replace it, check connection cable and if necessary repair or replace it
Others Error Properties
Priority 4, self healing, as measured value a default value will be showed.
FTSCDSysReac
Error Description
Fuel temperature: the fuel temperature calculated by ECU is above the target range; the ECU activates a system reaction
Error Codes
DEUTZ: 134, Blink: 2-3-7, SPN: 174, FMI (Bit 0,1,2,3): 0: data valid, but above normal working area 0: data valid, but above normal working area 11: Errormode not identifiable 11: Errormode not identifiable
Error Detection
Continuous light or blink of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Above target range with system reaction, interruption of fuel loop (for example, rail pressure relief valve defective), sensor defective, connection cable demaged
Corrective Action
Check fuel system and if necessary repair it, check sensor and if necessary replace it, check connection cable and if necessary repair or replace it
Others Error Properties
Priority 4, self healing, as measured value a current value will be showed.
To First Page
DEUTZ A
G, VS-TA, Fi, Su Page 30 von 67 Rev. 2.0
DTC - List
Diagnosis- and Fehlercodes
Referenced ECU Software P490_: 220, 310, 501 P491_: 220, 310, 400, 501
P492_: 213 P513_: 214, 300
OTSCD
Error Description
Customer specific temperature sensor 1: the voltage of sensor measured by ECU is out of the target range or the received value of temperature via CAN is defective
Error Codes
DEUTZ: 136, Blink: 1-3-3, SPN: 523618, FMI (Bit 0,1,2,3): 3: Voltage to high or short circuit to +Ubatt 4: Voltage to low or short circuit to -Ubatt 2: data stream is defective 11: Errormode not identifiable
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Cable break or short circuit (sensor 1), sensor defective, connection cable demaged, CAN bus wrong cabled, wiring demaged, receiver (sender of the message) work inaccurately, parametering inaccurate
Corrective Action
Customer specific bugfixing, check sensor and if necessary replace it, check connection cable and if necessary repair or replace it, Check CAN Bus cabling (Bus sheduling, polarity, short circuit, power interrupt), test protocol of receiver, check CAN fun
Others Error Properties
Priority 2, self healing, as measured value a default value will be showed.
GOTSCDSysReac
Error Description
Customer specific temperature 1: the temperature calculated by ECU is above the target range; the ECU activates a system reaction
Error Codes
DEUTZ: 137, Blink: 1-3-3, SPN: 523619, FMI (Bit 0,1,2,3): 2: data stream is defective 2: data stream is defective 11: Errormode not identifiable 11: Errormode not identifiable
Error Detection
Continuous light or blink of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Outside target range with system reaction (temperature 1), dependant on the application
Corrective Action
Customer specific bugfixing, denpendant on application
Others Error Properties
Priority 3, self healing, as measured value a current value will be showed.
HdThrt
Error Description
Hand throttle pedal sensor: the voltage measured by ECU is out of the target range or the calculated pedal position is implausible compared with the position of accelerator pedal 1
Error Codes
DEUTZ: 138, Blink: 1-2-6, SPN: 29, FMI (Bit 0,1,2,3): 3: Voltage to high or short circuit to +Ubatt 4: Voltage to low or short circuit to -Ubatt 11: Errormode not identifiable 2: data stream is defective
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Cable break or short circuit, signal implausible compared to signal of idle sensor, transmitter defective, connection cable demaged
Corrective Action
Check cabling, check sensor and if necessary replace it, check connection cable and if necessary repair or replace it
Others Error Properties
Priority 4, not self healing, as measured value a current value will be showed.
To First Page
DEUTZ A
G, VS-TA, Fi, Su Page 31 von 67 Rev. 2.0
DTC - List
Diagnosis- and Fehlercodes
Referenced ECU Software P490_: 220, 310, 501 P491_: 220, 310, 400, 501
P492_: 213 P513_: 214, 300
HOTSCD
Error Description
Customer specific temperature sensor 2: the voltage of sensor measured by ECU is out of the target range or the received value of temperature via CAN is defective
Error Codes
DEUTZ: 139, Blink: 3-1-4, SPN: 1638, FMI (Bit 0,1,2,3): 3: Voltage to high or short circuit to +Ubatt 4: Voltage to low or short circuit to -Ubatt 12: Defective component 11: Errormode not identifiable
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Cable break or short circuit (sensor 2), sensor defective, connection cable demaged, CAN bus wrong cabled, wiring demaged, receiver (sender of the message) work inaccurately, parametering inaccurate
Corrective Action
Customer specific bugfixing, check sensor and if necessary replace it, check connection cable and if necessary repair or replace it, Check CAN Bus cabling (Bus sheduling, polarity, short circuit, power interrupt), test protocol of receiver, check CAN fun
HOTSCDSysReac
Error Description
Customer specific temperature 2: the temperature calculated by ECU is above the target range; the ECU activates a system reaction
Error Codes
DEUTZ: 140, Blink: 3-1-4, SPN: 1638, FMI (Bit 0,1,2,3): 2: data stream is defective 2: data stream is defective 11: Errormode not identifiable 11: Errormode not identifiable
Error Detection
Continuous light or blink of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Outside target range with system reaction (temperature 2), dependant on the application
Corrective Action
Customer specific bugfixing, denpendant on application
Others Error Properties
Priority 3, self healing, as measured value a current value will be showed.
HWEMonCom
Error Description
Internal hardware monitoring: the ECU detects a communication distrubance
Error Codes
DEUTZ: 141, Blink: 5-5-5, SPN: 523617, FMI (Bit 0,1,2,3): 12: Defective component 11: Errormode not identifiable 11: Errormode not identifiable 11: Errormode not identifiable
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Communication with chip CJ 940 disturbed, ECU defective
Corrective Action
If cannot delete the error, change ECU
Others Error Properties
Priority 4, not self healing, as measured value a - will be showed.
To First Page
Others Error Properties
Priority 2, self healing, as measured value a default value will be showed.
DEUTZ A
G, VS-TA, Fi, Su Page 32 von 67 Rev. 2.0
DTC - List
Diagnosis- and Fehlercodes
Referenced ECU Software P490_: 220, 310, 501 P491_: 220, 310, 400, 501
P492_: 213 P513_: 214, 300
HWEMonEEPROM
Error Description
Internal hardware monitoring: the ECU finds an error during the access to ist EEPROM memory or works with an alternative value
Error Codes
DEUTZ: 142, Blink: 2-8-1, SPN: 630, FMI (Bit 0,1,2,3): 11: Errormode not identifiable 12: Defective component 12: Defective component 12: Defective component
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Error during EEPROM memory access or EEPROM works with substitute value, programming error, ECU defective
Corrective Action
If not programmed, EEPROM is defect --> ECU is defect, reprogram ECU and if necessary replace it
Others Error Properties
Priority 4, not self healing, as measured value a - will be showed.
HWEMonRcyLocked
Error Description
Internal hardware monitoring: the CPU of the ECU is reset and the cause is logged internally; no item will be created in error memory
Error Codes
DEUTZ: 143, Blink: 5-5-5, SPN: 523612, FMI (Bit 0,1,2,3): 11: Errormode not identifiable 11: Errormode not identifiable 11: Errormode not identifiable 14: Special Instructions
Error Detection
Blink of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
A recovery occurred which is stored as protected
Corrective Action
Recoverey occured which is stored as protected With parameter HWEMon_numRexxxxxxx the recovery nummer and the subsequent position can be identified. See especially SW-Doku _rcy_auto.pdf
Others Error Properties
Priority 5, not self healing, as measured value a - will be showed.
HWEMonRcySuppressed
Error Description
Internal hardware monitoring: the CPU of the ECU is reset and the cause is logged internally; no item will be created in error memory
Error Codes
DEUTZ: 144, Blink: 5-5-5, SPN: 523612, FMI (Bit 0,1,2,3): 11: Errormode not identifiable 11: Errormode not identifiable 11: Errormode not identifiable 14: Special Instructions
Error Detection
Blink of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
A recovery occurred which is not stored
Corrective Action
Recoverey occured which is stored as protected With parameter HWEMon_numRexxxxxxx the recovery nummer and the subsequent position can be identified. See especially SW-Doku _rcy_auto.pdf
Others Error Properties
Priority 5, not self healing, as measured value a - will be showed.
To First Page
DEUTZ A
G, VS-TA, Fi, Su Page 33 von 67 Rev. 2.0
DTC - List
Diagnosis- and Fehlercodes
Referenced ECU Software P490_: 220, 310, 501 P491_: 220, 310, 400, 501
P492_: 213 P513_: 214, 300
HWEMonRcyVisible
Error Description
Internal hardware monitoring: the CPU of the ECU is reset and an item will be created in error memory
Error Codes
DEUTZ: 145, Blink: 5-5-5, SPN: 523612, FMI (Bit 0,1,2,3): 11: Errormode not identifiable 11: Errormode not identifiable 11: Errormode not identifiable 14: Special Instructions
Error Detection
Blink of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
A recovery occurred which is visible in the error memory
Corrective Action
Recoverey occured which is stored as protected With parameter HWEMon_numRexxxxxxx the recovery nummer and the subsequent position can be identified. See especially SW-Doku _rcy_auto.pdf
HWEMonUMaxSupply
Error Description
Internal hardware monitoring: the ECU detects an excess of the target range for the power supply of ist communication module
Error Codes
DEUTZ: 146, Blink: 5-5-5, SPN: 523612, FMI (Bit 0,1,2,3): 3: Voltage to high or short circuit to +Ubatt 11: Errormode not identifiable 11: Errormode not identifiable 11: Errormode not identifiable
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Overvoltage at CJ940, power supply voltage too high, ECU defective
Corrective Action
Check working voltage and if necessary correct it, Check ECU and if necessary replace it
HWEMonUMinSupply
Error Description
Internal hardware monitoring: the ECU detects an undershooting of the target range for the power supply of ist communication module
Error Codes
DEUTZ: 147, Blink: 5-5-5, SPN: 523612, FMI (Bit 0,1,2,3): 11: Errormode not identifiable 4: Voltage to low or short circuit to -Ubatt 11: Errormode not identifiable 11: Errormode not identifiable
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Undervoltage at CJ940, power supply voltage too low, ECU defective
Corrective Action
Check working voltage and if necessary correct it, Check ECU and if necessary replace it
Others Error Properties
Priority 5, not self healing, as measured value a - will be showed.
DEUTZ A
G, VS-TA, Fi, Su Page 34 von 67 Rev. 2.0
Others Error Properties
Priority 4, not self healing, as measured value a - will be showed.
Others Error Properties
Priority 4, not self healing, as measured value a - will be showed.
To First Page
DTC - List
Diagnosis- and Fehlercodes
Referenced ECU Software P490_: 220, 310, 501 P491_: 220, 310, 400, 501
P492_: 213 P513_: 214, 300
IATSCD
Error Description
Charge air temperature sensor: the voltage of sensor measured by ECU is out of the target range or the received value of temperature via CAN is defective
Error Codes
DEUTZ: 149, Blink: 1-2-8, SPN: 105, FMI (Bit 0,1,2,3): 3: Voltage to high or short circuit to +Ubatt 4: Voltage to low or short circuit to -Ubatt 2: data stream is defective 11: Errormode not identifiable
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Cable break or short circuit, sensor defective, connection cable demaged, CAN bus wrong cabled, wiring demaged, receiver (sender of the message) work inaccurately, parametering inaccurate
Corrective Action
Check cabling, LDF6T-sensor not working, check sensor and if necessary replace it, check connection cable and if necessary repair or replace it, Check CAN Bus cabling (Bus sheduling, polarity, short circuit, power interrupt), test protocol of receiver, check CAN functional range
Others Error Properties
Priority 4, self healing, as measured value a default value will be showed.
IATSCDSysReac
Error Description
Charge air temperature: die charge air temperature calculated by ECU is above the target range; the ECU activates a system reaction
Error Codes
DEUTZ: 150, Blink: 2-3-3, SPN: 105, FMI (Bit 0,1,2,3): 0: data valid, but above normal working area 0: data valid, but above normal working area 11: Errormode not identifiable 11: Errormode not identifiable
Error Detection
Continuous light or blink of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Above target range with system reaction, air system demaged, sensor defective, connection cable demaged
Corrective Action
Check construction of LDF6T , check suction parts, check air system and if necessary repair it, check sensor and if necessary replace it, check connection cable and if necessary repair or replace it
Others Error Properties
Priority 4, self healing, as measured value a current value will be showed.
InjVlvBnk1A
Error Description
Injector cylinder bank 1: the current drain measured by ECU is above the target range
Error Codes
DEUTZ: 153, Blink: 1-5-1, SPN: 523350, FMI (Bit 0,1,2,3): 3: Voltage to high or short circuit to +Ubatt 4: Voltage to low or short circuit to -Ubatt 13: out of calibrated range 11: Errormode not identifiable
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Short circuit (cylinder bank 1), injector defective, connection cable demaged
Corrective Action
Check cabling, check injectors and if necessary replace them, check connection cable and if necessary repair or replace it
Others Error Properties
Priority 4, self healing, as measured value a current value will be showed.
To First Page
DEUTZ A
G, VS-TA, Fi, Su Page 35 von 67 Rev. 2.0
DTC - List
Diagnosis- and Fehlercodes
Referenced ECU Software P490_: 220, 310, 501 P491_: 220, 310, 400, 501
P492_: 213 P513_: 214, 300
InjVlvBnk1B
Error Description
Injector cylinder bank 1: the current drain measured by ECU is underneath the target range
Error Codes
DEUTZ: 154, Blink: 1-5-1, SPN: 523351, FMI (Bit 0,1,2,3): 13: out of calibrated range 13: out of calibrated range 5: current to low or broken wire 13: out of calibrated range
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Cable break (cylinder bank 1), injector defective, connection cable demaged
Corrective Action
Check cabling, check injectors and if necessary replace them, check connection cable and if necessary repair or replace it
InjVlvBnk2A
Error Description
Injector cylinder bank 2: the current drain measured by ECU is above the target range
Error Codes
DEUTZ: 155, Blink: 1-5-2, SPN: 523352, FMI (Bit 0,1,2,3): 3: Voltage to high or short circuit to +Ubatt 4: Voltage to low or short circuit to -Ubatt 13: out of calibrated range 11: Errormode not identifiable
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Short circuit (cylinder bank 2), injector defective, connection cable demaged
Corrective Action
Check cabling, check injectors and if necessary replace them, check connection cable and if necessary repair or replace it
InjVlvBnk2B
Error Description
Injector cylinder bank 2: the current drain measured by ECU is underneath the target range
Error Codes
DEUTZ: 156, Blink: 1-5-2, SPN: 523353, FMI (Bit 0,1,2,3): 13: out of calibrated range 13: out of calibrated range 5: current to low or broken wire 13: out of calibrated range
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Cable break (cylinder bank 2), injector defective, connection cable demaged
Corrective Action
Check cabling, check injectors and if necessary replace them, check connection cable and if necessary repair or replace it
Others Error Properties
Priority 4, self healing, as measured value a current value will be showed.
DEUTZ A
G, VS-TA, Fi, Su Page 36 von 67 Rev. 2.0
Others Error Properties
Priority 4, self healing, as measured value a current value will be showed.
Others Error Properties
Priority 4, self healing, as measured value a current value will be showed.
To First Page
DTC - List
Diagnosis- and Fehlercodes
Referenced ECU Software P490_: 220, 310, 501 P491_: 220, 310, 400, 501
P492_: 213 P513_: 214, 300
InjVlvChipA
Error Description
Internal hardware monitoring: the ECU detects an error of ist injector high current output
Error Codes
DEUTZ: 157, Blink: 1-5-3, SPN: 523354, FMI (Bit 0,1,2,3): 3: Voltage to high or short circuit to +Ubatt 2: data stream is defective 14: Special Instructions 12: Defective component
Error Detection
Blink of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
High power stage Injector A, ECU defective
Corrective Action
If error is not removable, change ECU
Others Error Properties
Priority 5, not self healing, as measured value a current value will be showed.
InjVlvChipB
Error Description
Internal hardware monitoring: the ECU detects a disturbance in its injector high current output
Error Codes
DEUTZ: 158, Blink: 1-5-3, SPN: 523355, FMI (Bit 0,1,2,3): 12: Defective component 12: Defective component 12: Defective component 12: Defective component
Error Detection
Blink of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
High power stage Injector B, ECU defective
Corrective Action
If error is not removable, change ECU
Others Error Properties
Priority 5, not self healing, as measured value a current value will be showed.
InjVlvCyl1A
Error Description
Injector 1: the current drain measured by ECU is above the target range
Error Codes
DEUTZ: 159, Blink: 1-5-4, SPN: 651, FMI (Bit 0,1,2,3): 3: Voltage to high or short circuit to +Ubatt 13: out of calibrated range 4: Voltage to low or short circuit to -Ubatt 11: Errormode not identifiable
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Short circuit (cylinder 1), injector defective, connection cable demaged
Corrective Action
Check cabling, check injectors and if necessary replace them, check connection cable and if necessary repair or replace it
Others Error Properties
Priority 4, self healing, as measured value a current value will be showed.
To First Page
DEUTZ A
G, VS-TA, Fi, Su Page 37 von 67 Rev. 2.0
DTC - List
Diagnosis- and Fehlercodes
Referenced ECU Software P490_: 220, 310, 501 P491_: 220, 310, 400, 501
P492_: 213 P513_: 214, 300
InjVlvCyl1B
Error Description
Injector 1: the current drain measured by ECU is underneath the target range
Error Codes
DEUTZ: 160, Blink: 1-5-4, SPN: 651, FMI (Bit 0,1,2,3): 13: out of calibrated range 13: out of calibrated range 5: current to low or broken wire 13: out of calibrated range
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Cable break (cylinder 1), injector defective, connection cable demaged
Corrective Action
Check cabling, check injectors and if necessary replace them, check connection cable and if necessary repair or replace it
InjVlvCyl2A
Error Description
Injector 2: the current drain measured by ECU is above the target range
Error Codes
DEUTZ: 161, Blink: 1-5-5, SPN: 652, FMI (Bit 0,1,2,3): 3: Voltage to high or short circuit to +Ubatt 13: out of calibrated range 4: Voltage to low or short circuit to -Ubatt 11: Errormode not identifiable
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Short circuit (cylinder 2), injector defective, connection cable demaged
Corrective Action
Check cabling, check injectors and if necessary replace them, check connection cable and if necessary repair or replace it
InjVlvCyl2B
Error Description
Injector 2: the current drain measured by ECU is underneath the target range
Error Codes
DEUTZ: 162, Blink: 1-5-5, SPN: 652, FMI (Bit 0,1,2,3): 13: out of calibrated range 13: out of calibrated range 5: current to low or broken wire 13: out of calibrated range
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Cable break (cylinder 2), injector defective, connection cable demaged
Corrective Action
Check cabling, check injectors and if necessary replace them, check connection cable and if necessary repair or replace it
Others Error Properties
Priority 3, self healing, as measured value a current value will be showed.
DEUTZ A
G, VS-TA, Fi, Su Page 38 von 67 Rev. 2.0
Others Error Properties
Priority 4, self healing, as measured value a current value will be showed.
Others Error Properties
Priority 3, self healing, as measured value a current value will be showed.
To First Page
DTC - List
Diagnosis- and Fehlercodes
Referenced ECU Software P490_: 220, 310, 501 P491_: 220, 310, 400, 501
P492_: 213 P513_: 214, 300
InjVlvCyl3A
Error Description
Injector 3: the current drain measured by ECU is above the target range
Error Codes
DEUTZ: 163, Blink: 1-5-6, SPN: 653, FMI (Bit 0,1,2,3): 3: Voltage to high or short circuit to +Ubatt 13: out of calibrated range 4: Voltage to low or short circuit to -Ubatt 11: Errormode not identifiable
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Short circuit (cylinder 3), injector defective, connection cable demaged
Corrective Action
Check cabling, check injectors and if necessary replace them, check connection cable and if necessary repair or replace it
InjVlvCyl3B
Error Description
Injector 3: the current drain measured by ECU is underneath the target range
Error Codes
DEUTZ: 164, Blink: 1-5-6, SPN: 653, FMI (Bit 0,1,2,3): 13: out of calibrated range 13: out of calibrated range 5: current to low or broken wire 13: out of calibrated range
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Cable break (cylinder 3), injector defective, connection cable demaged
Corrective Action
Check cabling, check injectors and if necessary replace them, check connection cable and if necessary repair or replace it
InjVlvCyl4A
Error Description
Injector 4: the current drain measured by ECU is above the target range
Error Codes
DEUTZ: 165, Blink: 1-6-1, SPN: 654, FMI (Bit 0,1,2,3): 3: Voltage to high or short circuit to +Ubatt 13: out of calibrated range 4: Voltage to low or short circuit to -Ubatt 11: Errormode not identifiable
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Short circuit (cylinder 4), injector defective, connection cable demaged
Corrective Action
Check cabling, check injectors and if necessary replace them, check connection cable and if necessary repair or replace it
Others Error Properties
Priority 4, self healing, as measured value a current value will be showed.
DEUTZ A
G, VS-TA, Fi, Su Page 39 von 67 Rev. 2.0
Others Error Properties
Priority 3, self healing, as measured value a current value will be showed.
Others Error Properties
Priority 4, self healing, as measured value a current value will be showed.
To First Page
DTC - List
Diagnosis- and Fehlercodes
Referenced ECU Software P490_: 220, 310, 501 P491_: 220, 310, 400, 501
P492_: 213 P513_: 214, 300
InjVlvCyl4B
Error Description
Injector 4: the current drain measured by ECU is underneath the target range
Error Codes
DEUTZ: 166, Blink: 1-6-1, SPN: 654, FMI (Bit 0,1,2,3): 13: out of calibrated range 13: out of calibrated range 5: current to low or broken wire 13: out of calibrated range
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Cable break (cylinder 4), injector defective, connection cable demaged
Corrective Action
Check cabling, check injectors and if necessary replace them, check connection cable and if necessary repair or replace it
InjVlvCyl5A
Error Description
Injector 5: the current drain measured by ECU is above the target range
Error Codes
DEUTZ: 167, Blink: 1-6-2, SPN: 655, FMI (Bit 0,1,2,3): 3: Voltage to high or short circuit to +Ubatt 13: out of calibrated range 4: Voltage to low or short circuit to -Ubatt 11: Errormode not identifiable
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Short circuit (cylinder 5), injector defective, connection cable demaged
Corrective Action
Check cabling, check injectors and if necessary replace them, check connection cable and if necessary repair or replace it
InjVlvCyl5B
Error Description
Injector 5: the current drain measured by ECU is underneath the target range
Error Codes
DEUTZ: 168, Blink: 1-6-2, SPN: 655, FMI (Bit 0,1,2,3): 13: out of calibrated range 13: out of calibrated range 5: current to low or broken wire 13: out of calibrated range
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Cable break (cylinder 5), injector defective, connection cable demaged
Corrective Action
Check cabling, check injectors and if necessary replace them, check connection cable and if necessary repair or replace it
Others Error Properties
Priority 3, self healing, as measured value a current value will be showed.
DEUTZ A
G, VS-TA, Fi, Su Page 40 von 67 Rev. 2.0
Others Error Properties
Priority 4, self healing, as measured value a current value will be showed.
Others Error Properties
Priority 3, self healing, as measured value a current value will be showed.
To First Page
DTC - List
Diagnosis- and Fehlercodes
Referenced ECU Software P490_: 220, 310, 501 P491_: 220, 310, 400, 501
P492_: 213 P513_: 214, 300
InjVlvCyl6A
Error Description
Injector 6: the current drain measured by ECU is above the target range
Error Codes
DEUTZ: 169, Blink: 1-6-3, SPN: 656, FMI (Bit 0,1,2,3): 3: Voltage to high or short circuit to +Ubatt 13: out of calibrated range 4: Voltage to low or short circuit to -Ubatt 11: Errormode not identifiable
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Short circuit (cylinder 6), injector defective, connection cable demaged
Corrective Action
Check cabling, check injectors and if necessary replace them, check connection cable and if necessary repair or replace it
InjVlvCyl6B
Error Description
Injector 6: the current drain measured by ECU is underneath the target range
Error Codes
DEUTZ: 170, Blink: 1-6-3, SPN: 656, FMI (Bit 0,1,2,3): 13: out of calibrated range 13: out of calibrated range 5: current to low or broken wire 13: out of calibrated range
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Cable break (cylinder 6), injector defective, connection cable demaged
Corrective Action
Check cabling, check injectors and if necessary replace them, check connection cable and if necessary repair or replace it
InjVlvCyl7A
Error Description
Injector 7: the current drain measured by ECU is above the target range
Error Codes
DEUTZ: 171, Blink: 1-6-4, SPN: 657, FMI (Bit 0,1,2,3): 3: Voltage to high or short circuit to +Ubatt 13: out of calibrated range 4: Voltage to low or short circuit to -Ubatt 11: Errormode not identifiable
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Short circuit (cylinder 7), injector defective, connection cable demaged
Corrective Action
Check cabling, check injectors and if necessary replace them, check connection cable and if necessary repair or replace it
Others Error Properties
Priority 4, self healing, as measured value a current value will be showed.
DEUTZ A
G, VS-TA, Fi, Su Page 41 von 67 Rev. 2.0
Others Error Properties
Priority 3, self healing, as measured value a current value will be showed.
Others Error Properties
Priority 4, self healing, as measured value a current value will be showed.
To First Page
DTC - List
Diagnosis- and Fehlercodes
Referenced ECU Software P490_: 220, 310, 501 P491_: 220, 310, 400, 501
P492_: 213 P513_: 214, 300
InjVlvCyl7B
Error Description
Injector 7: the current drain measured by ECU is underneath the target range
Error Codes
DEUTZ: 172, Blink: 1-6-4, SPN: 657, FMI (Bit 0,1,2,3): 13: out of calibrated range 13: out of calibrated range 5: current to low or broken wire 13: out of calibrated range
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Cable break (cylinder 7), injector defective, connection cable demaged
Corrective Action
Check cabling, check injectors and if necessary replace them, check connection cable and if necessary repair or replace it
InjVlvCyl8A
Error Description
Injector 8: the current drain measured by ECU is above the target range
Error Codes
DEUTZ: 173, Blink: 1-6-5, SPN: 658, FMI (Bit 0,1,2,3): 3: Voltage to high or short circuit to +Ubatt 13: out of calibrated range 4: Voltage to low or short circuit to -Ubatt 11: Errormode not identifiable
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Short circuit (cylinder 8), injector defective, connection cable demaged
Corrective Action
Check cabling, check injectors and if necessary replace them, check connection cable and if necessary repair or replace it
InjVlvCyl8B
Error Description
Injector 8: the current drain measured by ECU is underneath the target range
Error Codes
DEUTZ: 174, Blink: 1-6-5, SPN: 658, FMI (Bit 0,1,2,3): 13: out of calibrated range 13: out of calibrated range 5: current to low or broken wire 13: out of calibrated range
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Cable break (cylinder 8), injector defective, connection cable demaged
Corrective Action
Check cabling, check injectors and if necessary replace them, check connection cable and if necessary repair or replace it
Others Error Properties
Priority 3, self healing, as measured value a current value will be showed.
DEUTZ A
G, VS-TA, Fi, Su Page 42 von 67 Rev. 2.0
Others Error Properties
Priority 4, self healing, as measured value a current value will be showed.
Others Error Properties
Priority 3, self healing, as measured value a current value will be showed.
To First Page
DTC - List
Diagnosis- and Fehlercodes
Referenced ECU Software P490_: 220, 310, 501 P491_: 220, 310, 400, 501
P492_: 213 P513_: 214, 300
InjVlvErrDet
Error Description
Rail pressure monitoring: the monitoring of the rail pressure will be deactivated by ECU because of the activation of the function "compression test" by user
Error Codes
DEUTZ: 175, Blink: 5-5-5, SPN: 523370, FMI (Bit 0,1,2,3): 14: Special Instructions 11: Errormode not identifiable 11: Errormode not identifiable 11: Errormode not identifiable
Error Detection
0 of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Compression test active: rail-pressure monitoring is going to be disabled
Corrective Action
not correct
Others Error Properties
Priority 1, not self healing, as measured value a 0 will be showed.
MeUnCD_ADC
Error Description
Fuel volume flow rate: the fuel volume rate calculated by ECU at outlet of the fuel metering unit is out of the target range
Error Codes
DEUTZ: 176, Blink: 1-3-5, SPN: 523615, FMI (Bit 0,1,2,3): 3: Voltage to high or short circuit to +Ubatt 4: Voltage to low or short circuit to -Ubatt 11: Errormode not identifiable 11: Errormode not identifiable
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Flow rate outside target range
Corrective Action
Check cabling , if necessary check FCU, check fuel metering unit and if necessary replace it, check connection cable and if necessary repair or replace it
Others Error Properties
Priority 4, not self healing, as measured value a current value will be showed.
MeUnCDNoLoad
Error Description
Valve at outlet of the fuel metering unit: the ECU detects no load or temperature excess of the ECU component for power supply of the valve
Error Codes
DEUTZ: 177, Blink: 1-3-5, SPN: 523615, FMI (Bit 0,1,2,3): 11: Errormode not identifiable 11: Errormode not identifiable 5: current to low or broken wire 12: Defective component
Error Detection
Continuous light, 15s blink before shut off of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
wiring error or ECU output is switched off because of overtemperature, fuel metering unit defective, connection cable demaged
Corrective Action
Check cabling , if necessary check FCU, check fuel metering unit and if necessary replace it, check connection cable and if necessary repair or replace it
Others Error Properties
Priority 4, not self healing, as measured value a current value will be showed.
To First Page
DEUTZ A
G, VS-TA, Fi, Su Page 43 von 67 Rev. 2.0
DTC - List
Diagnosis- and Fehlercodes
Referenced ECU Software P490_: 220, 310, 501 P491_: 220, 310, 400, 501
P492_: 213 P513_: 214, 300
MeUnCDSCBat
Error Description
Valve at outlet of the fuel metering unit: the current drain measured by ECU is above the target range
Error Codes
DEUTZ: 178, Blink: 1-3-5, SPN: 523615, FMI (Bit 0,1,2,3): 12: Defective component 11: Errormode not identifiable 11: Errormode not identifiable 11: Errormode not identifiable
Error Detection
Continuous light, 15s blink before shut off of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Short circuit to Ubatt, fuel metering unit defective, connection cable demaged
Corrective Action
Check cabling , if necessary check FCU, check fuel metering unit and if necessary replace it, check connection cable and if necessary repair or replace it
MeUnCDSCGnd
Error Description
Valve at outlet of the fuel metering unit: the current drain measured by ECU is above the target range
Error Codes
DEUTZ: 179, Blink: 1-3-5, SPN: 523615, FMI (Bit 0,1,2,3): 11: Errormode not identifiable 12: Defective component 11: Errormode not identifiable 11: Errormode not identifiable
Error Detection
Continuous light, 15s blink before shut off of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Short circuit to ground, fuel metering unit defective, connection cable demaged
Corrective Action
Check cabling , if necessary check FCU, check fuel metering unit and if necessary replace it, check connection cable and if necessary repair or replace it
MnRly1_SCB
Error Description
Main relay 1: the current drains measured by ECU is above the target range
Error Codes
DEUTZ: 182, Blink: 1-3-7, SPN: 2634, FMI (Bit 0,1,2,3): 3: Voltage to high or short circuit to +Ubatt 11: Errormode not identifiable 11: Errormode not identifiable 11: Errormode not identifiable
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Short circuit to Ubatt (relay 1), relay defective, connection cable demaged
Corrective Action
Check cabling, check ECU, check relay and if necessary replace it, check connection cable and if necessary repair or replace it
Others Error Properties
Priority 4, not self healing, as measured value a current value will be showed.
DEUTZ A
G, VS-TA, Fi, Su Page 44 von 67 Rev. 2.0
Others Error Properties
Priority 4, not self healing, as measured value a current value will be showed.
Others Error Properties
Priority 3, not self healing, as measured value a current value will be showed.
To First Page
DTC - List
Diagnosis- and Fehlercodes
Referenced ECU Software P490_: 220, 310, 501 P491_: 220, 310, 400, 501
P492_: 213 P513_: 214, 300
MnRly1_SCG
Error Description
Main relay 1: the current drains measured by ECU is above the target range
Error Codes
DEUTZ: 183, Blink: 1-3-8, SPN: 2634, FMI (Bit 0,1,2,3): 11: Errormode not identifiable 4: Voltage to low or short circuit to -Ubatt 11: Errormode not identifiable 11: Errormode not identifiable
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Short circuit to ground (relay 1), relay defective, connection cable demaged
Corrective Action
Check cabling, check ECU, check relay and if necessary replace it, check connection cable and if necessary repair or replace it
Others Error Properties
Priority 3, not self healing, as measured value a current value will be showed.
Montr
Error Description
Internal hardware monitoring: the ECU detects an disturbance in ist monitoring module (Wachtdog)
Error Codes
DEUTZ: 184, Blink: 1-3-9, SPN: 523420, FMI (Bit 0,1,2,3): 11: Errormode not identifiable 11: Errormode not identifiable 11: Errormode not identifiable 14: Special Instructions
Error Detection
Blink of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Watchdog counter exceeds maximum, ECU defective
Corrective Action
If error is not removable, change ECU
Others Error Properties
Priority 5, not self healing, as measured value a - will be showed.
MRlyCD
Error Description
Main relay: during the switching off, main relay does not switch on within an allowed time
Error Codes
DEUTZ: 186, Blink: 2-6-1, SPN: 2634, FMI (Bit 0,1,2,3): 7: Mechanical system not OK 12: Defective component 11: Errormode not identifiable 11: Errormode not identifiable
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
EDC16: main relay not open in allowed time or main relay open too early; EDC7: main relay not open in allowed time or short circuit of main relay to ground; EDC16: main relay defective, connection cable demaged; generally: rapid shut-off of the ECU (without waiting till the end of the afterrun), ECU defective
Corrective Action
EDC16: check external main relay, check cabling EDC7: if error is not removable, change ECU, EDC16: Check main relay and if necessary replace it, check connection cable and if necessary repair or replace it; both: if error is not removable, change ECU
DEUTZ A
Others Error Properties
Priority 3, not self healing, as measured value a current value will be showed.
To First Page
G, VS-TA, Fi, Su Page 45 von 67 Rev. 2.0
DTC - List
Diagnosis- and Fehlercodes
Referenced ECU Software P490_: 220, 310, 501 P491_: 220, 310, 400, 501
P492_: 213 P513_: 214, 300
MRlyCDMnRly2
Error Description
Main relay 2 (in ECU): during the switching off, main relay does not switch on within an allowed time
Error Codes
DEUTZ: 187, Blink: 2-6-1, SPN: 563, FMI (Bit 0,1,2,3): 7: Mechanical system not OK 12: Defective component 11: Errormode not identifiable 11: Errormode not identifiable
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
rapid shut-off of the ECU (without waiting till the end of the afterrun), ECU defective
Corrective Action
If error not removable, change ECU
Others Error Properties
Priority 3, not self healing, as measured value a current value will be showed.
MRlyCDMnRly3
Error Description
Main relay 3 (in ECU): during the switching off, main relay does not switch on within an allowed time
Error Codes
DEUTZ: 188, Blink: 2-6-1, SPN: 2634, FMI (Bit 0,1,2,3): 7: Mechanical system not OK 12: Defective component 11: Errormode not identifiable 11: Errormode not identifiable
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Short circuit to ground or emergency shut-off (relay 3 internal), rapid shut-off of the ECU (without waiting till the end of the afterrun), ECU defective
Corrective Action
Check cabling, check ECU, if error not removable, change ECU
Others Error Properties
Priority 3, not self healing, as measured value a current value will be showed.
MSSCD1
Error Description
Multi state switch 1: the voltage measured by ECU is out of the target range or the swith setting is not plausible
Error Codes
DEUTZ: 189, Blink: 1-4-3, SPN: 523450, FMI (Bit 0,1,2,3): 3: Voltage to high or short circuit to +Ubatt 4: Voltage to low or short circuit to -Ubatt 11: Errormode not identifiable 2: data stream is defective
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Cable break or short circuit, input voltage outside target range (switch 1), switch defective, connection cable demaged
Corrective Action
Check cabling and sensor, check switch and if necessary replace it, check connection cable and if necessary repair or replace it
Others Error Properties
Priority 2, self healing, as measured value a default value will be showed.
To First Page
DEUTZ A
G, VS-TA, Fi, Su Page 46 von 67 Rev. 2.0
DTC - List
Diagnosis- and Fehlercodes
Referenced ECU Software P490_: 220, 310, 501 P491_: 220, 310, 400, 501
P492_: 213 P513_: 214, 300
MSSCD2
Error Description
Multi state switch 2: the voltage measured by ECU is out of the target range or the swith setting is not plausible
Error Codes
DEUTZ: 190, Blink: 1-4-3, SPN: 523451, FMI (Bit 0,1,2,3): 3: Voltage to high or short circuit to +Ubatt 4: Voltage to low or short circuit to -Ubatt 11: Errormode not identifiable 2: data stream is defective
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Cable break or short circuit, input voltage outside target range (switch 2), switch defective, connection cable demaged
Corrective Action
Check cabling and sensor, check switch and if necessary replace it, check connection cable and if necessary repair or replace it
Others Error Properties
Priority 2, self healing, as measured value a default value will be showed.
MSSCD3
Error Description
Multi state switch 3: the voltage measured by ECU is out of the target range or the swith setting is not plausible
Error Codes
DEUTZ: 191, Blink: 1-4-3, SPN: 523452, FMI (Bit 0,1,2,3): 3: Voltage to high or short circuit to +Ubatt 4: Voltage to low or short circuit to -Ubatt 11: Errormode not identifiable 2: data stream is defective
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Cable break or short circuit, input voltage outside target range (switch 3), switch defective, connection cable demaged
Corrective Action
Check cabling and sensor, check switch and if necessary replace it, check connection cable and if necessary repair or replace it
Others Error Properties
Priority 2, self healing, as measured value a default value will be showed.
NetMngCANAOff
Error Description
CAN bus A: the ECU is not allowed to send messages, because the status "BusOff" is detected
Error Codes
DEUTZ: 192, Blink: 2-7-1, SPN: 639, FMI (Bit 0,1,2,3): 14: Special Instructions 11: Errormode not identifiable 11: Errormode not identifiable 11: Errormode not identifiable
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Cable break or short circuit, off-state (CAN bus A), CAN bus deactivated, connection cable demaged
Corrective Action
Check cabling of CAN bus and if necessary repair it, check connection cable and if necessary repair or replace it
Others Error Properties
Priority 2, self healing, as measured value a 0 will be showed.
To First Page
DEUTZ A
G, VS-TA, Fi, Su Page 47 von 67 Rev. 2.0
DTC - List
Diagnosis- and Fehlercodes
Referenced ECU Software P490_: 220, 310, 501 P491_: 220, 310, 400, 501
P492_: 213 P513_: 214, 300
NetMngCANBOff
Error Description
CAN bus B: the ECU is not allowed to send messages, because the status "BusOff" is detected
Error Codes
DEUTZ: 193, Blink: 2-7-1, SPN: 1231, FMI (Bit 0,1,2,3): 14: Special Instructions 11: Errormode not identifiable 11: Errormode not identifiable 11: Errormode not identifiable
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Cable break or short circuit, off-state (CAN bus B), CAN bus deactivated, connection cable demaged
Corrective Action
Check cabling of CAN bus and if necessary repair it, check connection cable and if necessary repair or replace it
Others Error Properties
Priority 2, self healing, as measured value a 0 will be showed.
NetMngCANCOff
Error Description
CAN bus C: the ECU is not allowed to send messages, because the status "BusOff" is detected
Error Codes
DEUTZ: 194, Blink: 2-7-1, SPN: 1235, FMI (Bit 0,1,2,3): 14: Special Instructions 11: Errormode not identifiable 11: Errormode not identifiable 11: Errormode not identifiable
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Cable break or short circuit, off-state (CAN bus C), CAN bus deactivated, connection cable demaged
Corrective Action
Check cabling of CAN bus and if necessary repair it, check connection cable and if necessary repair or replace it
Others Error Properties
Priority 2, self healing, as measured value a 0 will be showed.
OPLpCD
Error Description
Warning lamp for oil level: the current drain measured by ECU is out of the target range or the maximum temperature of the ECU component for power supply of the lamp is exceeded
Error Codes
DEUTZ: 195, Blink: 1-3-5, SPN: 705, FMI (Bit 0,1,2,3): 3: Voltage to high or short circuit to +Ubatt 4: Voltage to low or short circuit to -Ubatt 5: current to low or broken wire 2: data stream is defective
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Cable break or short circuit, lamp defective, connection cable demaged
Corrective Action
Check cabling and load, check lamp and if necessary replace it, check connection cable and if necessary repair or replace it
Others Error Properties
Priority 1, not self healing, as measured value a default value will be showed.
To First Page
DEUTZ A
G, VS-TA, Fi, Su Page 48 von 67 Rev. 2.0
DTC - List
Diagnosis- and Fehlercodes
Referenced ECU Software P490_: 220, 310, 501 P491_: 220, 310, 400, 501
P492_: 213 P513_: 214, 300
OPSCD
Error Description
Oil pressure sensor: the voltage of sensor measured by ECU is out of the target range or the received value of oil pressure via CAN is implausible (Oil pressure is above the target range with higher oil temperature at the same time)
Error Codes
DEUTZ: 196, Blink: 2-2-4, SPN: 100, FMI (Bit 0,1,2,3): 3: Voltage to high or short circuit to +Ubatt 4: Voltage to low or short circuit to -Ubatt 2: data stream is defective 0: data valid, but above normal working area
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Cable break or short circuit, sensor defective, connection cable demaged, CAN bus wrong cabled, wiring demaged, receiver (sender of the message) work inaccurately, parametering inaccurate
Corrective Action
Check cabling, if sensor not working, check sensor and if necessary replace it, check connection cable and if necessary repair or replace it, Check CAN Bus cabling (Bus sheduling, polarity, short circuit, power interrupt), test protocol of receiver, check CAN functional range
Others Error Properties
Priority 4, self healing, as measured value a default value will be showed.
OPSCD1
Error Description
Oil pressure: the oil pressure calculated by ECU is implausibly low
Error Codes
DEUTZ: 197, Blink: 2-3-1, SPN: 100, FMI (Bit 0,1,2,3): 11: Errormode not identifiable 11: Errormode not identifiable 11: Errormode not identifiable 1: data valid, but below normal working area
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Oil pressure implausible low, sensor defective, connection cable demaged
Corrective Action
Check cabling, if sensor not working, check sensor and if necessary replace it, check connection cable and if necessary repair or replace it
Others Error Properties
Priority 2, self healing, as measured value a current value will be showed.
OPSCDSysReacHi
Error Description
Oil pressure: the oil pressure calculated by ECU is above the target range; the ECU activates a system reaction
Error Codes
DEUTZ: 198, Blink: 2-3-1, SPN: 100, FMI (Bit 0,1,2,3): 0: data valid, but above normal working area 0: data valid, but above normal working area 11: Errormode not identifiable 11: Errormode not identifiable
Error Detection
Continuous light or blink of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Above target range, oil volume too large, sensor defective, oil pump defective, connection cable demaged
Corrective Action
Check oil level and if necessary correct it, check oil pump and if necessary replace it, check sensor and if necessary replace it, check connection cable and if necessary repair or replace it
Others Error Properties
Priority 4, self healing, as measured value a current value will be showed.
To First Page
DEUTZ A
G, VS-TA, Fi, Su Page 49 von 67 Rev. 2.0
DTC - List
Diagnosis- and Fehlercodes
Referenced ECU Software P490_: 220, 310, 501 P491_: 220, 310, 400, 501
P492_: 213 P513_: 214, 300
OPSCDSysReacLo
Error Description
Oil pressure: the oil pressure calculated by ECU is underneath the target range; the ECU activates a system reaction
Error Codes
DEUTZ: 199, Blink: 2-3-1, SPN: 100, FMI (Bit 0,1,2,3): 1: data valid, but below normal working area 1: data valid, but below normal working area 11: Errormode not identifiable 11: Errormode not identifiable
Error Detection
Continuous light or blink of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Below target range, oil volume too small, sensor defective, oil pump defective, connection cable demaged
Corrective Action
Check oil level and if necessary correct it, check oil pump and if necessary replace it, check sensor and if necessary replace it, check connection cable and if necessary repair or replace it
Others Error Properties
Priority 4, self healing, as measured value a current value will be showed.
OSwCD
Error Description
Bridgeover switch: the ECU receives a permanent signal
Error Codes
DEUTZ: 200, Blink: 1-4-5, SPN: 1237, FMI (Bit 0,1,2,3): 11: Errormode not identifiable 11: Errormode not identifiable 11: Errormode not identifiable 2: data stream is defective
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Switch is blocked, taster locked, connection cable demaged
Corrective Action
Check cabling, if sensor not working, check switch and if necessary replace it, check connection cable and if necessary repair or replace it
Others Error Properties
Priority 2, self healing, as measured value a current value will be showed.
OTSCD
Error Description
Oil temperature sensor: the voltage of sensor measured by ECU is out of the target range; the oil temperature calculated by ECU is implausible compared with coolant temperature or the received value via CAN is defective
Error Codes
DEUTZ: 201, Blink: 1-4-4, SPN: 175, FMI (Bit 0,1,2,3): 3: Voltage to high or short circuit to +Ubatt 4: Voltage to low or short circuit to -Ubatt 2: data stream is defective 2: data stream is defective
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Cable break or short circuit, sensor defective, connection cable demaged
Corrective Action
Check cabling, if sensor not working, check switch and if necessary replace it, check connection cable and if necessary repair or replace it
Others Error Properties
Priority 4, self healing, as measured value a default value will be showed.
To First Page
DEUTZ A
G, VS-TA, Fi, Su Page 50 von 67 Rev. 2.0
DTC - List
Diagnosis- and Fehlercodes
Referenced ECU Software P490_: 220, 310, 501 P491_: 220, 310, 400, 501
P492_: 213 P513_: 214, 300
OTSCDSysReac
Error Description
Oil temperature: the oil temperature calculated by ECU is above the target range; the ECU activates a system reaction
Error Codes
DEUTZ: 203, Blink: 1-4-4, SPN: 175, FMI (Bit 0,1,2,3): 0: data valid, but above normal working area 0: data valid, but above normal working area 11: Errormode not identifiable 11: Errormode not identifiable
Error Detection
Continuous light or blink of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Above target range with system reaction, oil volume too small, oil loop disturbed, sensor defective, connection cable demaged
Corrective Action
Check cycle cooling system and compressor, check oil level and if necessary correct it, check sensor and if necessary replace it, check oil loop and if necessary repair it, check connection cable and if necessary repair or replace it
Others Error Properties
Priority 4, self healing, as measured value a current value will be showed.
PRVMon
Error Description
Rail pressure relief valve: is open, will be forced to open, the forced-open failed
Error Codes
DEUTZ: 208, Blink: 1-4-6, SPN: 523470, FMI (Bit 0,1,2,3): 14: Special Instructions 2: data stream is defective 12: Defective component 11: Errormode not identifiable
Error Detection
Continuous light, 15s blink before shut off of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Rail pressure relief valve open or forced open abortive (interpretation of the rail pressure gradient), operating voltage too low, rail pressure sensor defective, fuel metering unit defective, rail pressure relief valve defective, air in fuel system
Corrective Action
Check working voltage and if necessary correct it, check rail-pressure sensor and if necessary replace it, check FCU and if necessary replace it, check rail pressure relief valve and if necessary replace it, bleed the fuel-system
Others Error Properties
Priority 4, not self healing, as measured value a current value will be showed.
RailCD
Error Description
Rail pressure sensor: the voltage of sensor measured by ECU is out of the target range
Error Codes
DEUTZ: 209, Blink: 1-4-7, SPN: 157, FMI (Bit 0,1,2,3): 3: Voltage to high or short circuit to +Ubatt 4: Voltage to low or short circuit to -Ubatt 11: Errormode not identifiable 11: Errormode not identifiable
Error Detection
Continuous light, 15s blink before shut off of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Cable break or short circuit, sensor defective, connection cable demaged
Corrective Action
Check cabling, check rail pressure sensor and if necessary replace it, check connection cable and if necessary repair or replace it
Others Error Properties
Priority 4, not self healing, as measured value a default value will be showed.
To First Page
DEUTZ A
G, VS-TA, Fi, Su Page 51 von 67 Rev. 2.0
DTC - List
Diagnosis- and Fehlercodes
Referenced ECU Software P490_: 220, 310, 501 P491_: 220, 310, 400, 501
P492_: 213 P513_: 214, 300
RailCDOfsTst
Error Description
Rail pressure sensor: the change of the voltage measured by ECU during the engine start or the after-run is out of the target range
Error Codes
DEUTZ: 210, Blink: 1-4-7, SPN: 157, FMI (Bit 0,1,2,3): 0: data valid, but above normal working area 1: data valid, but below normal working area 11: Errormode not identifiable 11: Errormode not identifiable
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Deviation of signal during start or after-run above target range, sensor defective
Corrective Action
Replace sensor
Others Error Properties
Priority 2, self healing, as measured value a current value will be showed.
RailMeUn0
Error Description
Rail pressure: the fuel pressure in rail calculated by ECU is above the target range which is dependant on the engine speed
Error Codes
DEUTZ: 211, Blink: 1-3-4, SPN: 523613, FMI (Bit 0,1,2,3): 0: data valid, but above normal working area 11: Errormode not identifiable 11: Errormode not identifiable 11: Errormode not identifiable
Error Detection
Continuous light or blink of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
1) Leakage in high pressure system (external) ,
2) Leakage at rail pressure relief valve (internal),
3) Needle clampt in open position,
4) Abrasion at injector,
5) Abrasion at high pressure pump,
6) Too low primary pressure on low pressure side, sensor defective, fuel system disturbed
Corrective Action
(A) Check for leakage (B) Chek fuel-primary pressure (C) Change components, check sensor and if necessary replace it, check fuel system and if necessary repair it
RailMeUn1
Error Description
Rail pressure: the fuel pressure in rail calculated by ECU is above the target range which is dependant on the volume flow rate
Error Codes
DEUTZ: 212, Blink: 1-3-4, SPN: 523613, FMI (Bit 0,1,2,3): 0: data valid, but above normal working area 11: Errormode not identifiable 11: Errormode not identifiable 11: Errormode not identifiable
Error Detection
Continuous light or blink of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
1) Leakage in high pressure system (external) ,
2) Leakage at rail pressure relief valve (internal),
3) Needle clampt in open position,
4) Abrasion at injector,
5) Abrasion at high pressure pump,
6) Too low primary pressure on low pressure side, sensor defective, fuel system disturbed
Corrective Action
(A) Check for leakage (B) Chek fuel-primary pressure (C) Change components, check sensor and if necessary replace it, check fuel system and if necessary repair it
DEUTZ A
Others Error Properties
Priority 4, self healing, as measured value a current value will be showed.
Others Error Properties
Priority 4, self healing, as measured value a current value will be showed.
To First Page
G, VS-TA, Fi, Su Page 52 von 67 Rev. 2.0
DTC - List
Diagnosis- and Fehlercodes
Referenced ECU Software P490_: 220, 310, 501 P491_: 220, 310, 400, 501
P492_: 213 P513_: 214, 300
RailMeUn2
Error Description
Rail pressure: the fuel pressure in rail calculated by ECU is underneath the target range which is dependant on the engine speed
Error Codes
DEUTZ: 213, Blink: 1-3-4, SPN: 523613, FMI (Bit 0,1,2,3): 0: data valid, but above normal working area 11: Errormode not identifiable 11: Errormode not identifiable 11: Errormode not identifiable
Error Detection
Continuous light or blink of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
1) No power supply in FCU,
2) ZME clamped in open position,
3) Too high pressure nach Nullförderdrossel (FCU),
4) Nullförderdrossel clogged,
5) Too high primary pressure on low pressure side, sensor defective, fuel system disturbed
Corrective Action
(A) Check return-pressure FCU (B) Check flow-pressure (C) Change FCU, check sensor and if necessary replace it, check fuel system and if necessary repair it
Others Error Properties
Priority 4, self healing, as measured value a current value will be showed.
RailMeUn3
Error Description
Rail pressure: the fuel pressure in rail calculated by ECU is underneath the target range which is dependant on the volume flow rate
Error Codes
DEUTZ: 214, Blink: 1-3-4, SPN: 523613, FMI (Bit 0,1,2,3): 1: data valid, but below normal working area 11: Errormode not identifiable 11: Errormode not identifiable 11: Errormode not identifiable
Error Detection
Continuous light or blink of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
1) Leakage in high pressure system (external) ,
2) Leakage at rail pressure relief valve (internal),
3) Needle clampt in open position,
4) Abrasion at injector,
5) Abrasion at high pressure pump,
6) Too low primary pressure on low pressure side, sensor defective, fuel system disturbed
Corrective Action
(A) Check for leakage (B) Chek fuel-primary pressure (C) Change components, check sensor and if necessary replace it, check fuel system and if necessary repair it
Others Error Properties
Priority 4, self healing, as measured value a current value will be showed.
RailMeUn4
Error Description
Rail pressure: the fuel pressure in rail calculated by ECU is above the absolute target range
Error Codes
DEUTZ: 215, Blink: 1-3-4, SPN: 523613, FMI (Bit 0,1,2,3): 0: data valid, but above normal working area 11: Errormode not identifiable 11: Errormode not identifiable 11: Errormode not identifiable
Error Detection
Continuous light or blink of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
1) No power supply in FCU,
2) ZME clamped in open position,
3) Too high pressure nach Nullförderdrossel (FCU),
4) Nullförderdrossel clogged,
5) Too high primary pressure on low pressure side, sensor defective, fuel system disturbed
Corrective Action
(A) Check return-pressure FCU (B) Check flow-pressure (C) Change FCU, check sensor and if necessary replace it, check fuel system and if necessary repair it
Others Error Properties
Priority 4, self healing, as measured value a current value will be showed.
To First Page
DEUTZ A
G, VS-TA, Fi, Su Page 53 von 67 Rev. 2.0
DTC - List
Diagnosis- and Fehlercodes
Referenced ECU Software P490_: 220, 310, 501 P491_: 220, 310, 400, 501
P492_: 213 P513_: 214, 300
RailMeUn7
Error Description
Rail pressure: the fuel pressure in rail calculated by ECU is implausible compared with the setpoint setting of the fuel metering unit
Error Codes
DEUTZ: 216, Blink: 1-3-4, SPN: 523613, FMI (Bit 0,1,2,3): 2: data stream is defective 11: Errormode not identifiable 11: Errormode not identifiable 11: Errormode not identifiable
Error Detection
Continuous light or blink of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
1) Leakage in high pressure system (external) ,
2) Leakage at rail pressure relief valve (internal),
3) Needle clampt in open position,
4) Abrasion at injector,
5) Abrasion at high pressure pump,
6) Too low primary pressure on low pressure side, sensor defective, fuel system disturbed
Corrective Action
(A) Check for leakage (B) Chek fuel-primary pressure (C) Change components, check sensor and if necessary replace it, check fuel system and if necessary repair it
Others Error Properties
Priority 4, self healing, as measured value a current value will be showed.
SOPTst
Error Description
Internal hardware monitoring: the ECU finds an disturbance in the redundant switch off path through a test during the ramp up phase
Error Codes
DEUTZ: 218, Blink: 1-4-9, SPN: 523490, FMI (Bit 0,1,2,3): 11: Errormode not identifiable 12: Defective component 3: Voltage to high or short circuit to +Ubatt 4: Voltage to low or short circuit to -Ubatt
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Test of redundant shut-off paths
Corrective Action
Could be triggered by over/undervoltage or external Watchdog
Others Error Properties
Priority 4, not self healing, as measured value a - will be showed.
SSpMon1
Error Description
Internal hardware monitoring: the ECU detects a deviation of the target range of the power supply voltage of sensor 1
Error Codes
DEUTZ: 219, Blink: 2-8-2, SPN: 1079, FMI (Bit 0,1,2,3): 3: Voltage to high or short circuit to +Ubatt 4: Voltage to low or short circuit to -Ubatt 11: Errormode not identifiable 11: Errormode not identifiable
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
5V sensor supply voltage 1 outside target range, operating voltage too high or to low, connection cable demaged, ECU defective
Corrective Action
If error not removable, change ECU, check cabling of external components, check working voltage and if necessary correct it, check connection cable and if necessary repair or replace it
Others Error Properties
Priority 3, self healing, as measured value a current value will be showed.
To First Page
DEUTZ A
G, VS-TA, Fi, Su Page 54 von 67 Rev. 2.0
DTC - List
Diagnosis- and Fehlercodes
Referenced ECU Software P490_: 220, 310, 501 P491_: 220, 310, 400, 501
P492_: 213 P513_: 214, 300
SSpMon2
Error Description
Internal hardware monitoring: the ECU detects a deviation of the target range of the power supply voltage of sensor 2
Error Codes
DEUTZ: 221, Blink: 2-8-2, SPN: 1080, FMI (Bit 0,1,2,3): 3: Voltage to high or short circuit to +Ubatt 4: Voltage to low or short circuit to -Ubatt 11: Errormode not identifiable 11: Errormode not identifiable
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
5V sensor supply voltage 2 outside target range, operating voltage too high or to low, connection cable demaged, ECU defective
Corrective Action
If error not removable, change ECU, check cabling of external components, check working voltage and if necessary correct it, check connection cable and if necessary repair or replace it
Others Error Properties
Priority 3, self healing, as measured value a current value will be showed.
SSpMon3
Error Description
Internal hardware monitoring: the ECU detects a deviation of the target range of the power supply voltage of sensor 3
Error Codes
DEUTZ: 222, Blink: 2-8-2, SPN: 523601, FMI (Bit 0,1,2,3): 3: Voltage to high or short circuit to +Ubatt 4: Voltage to low or short circuit to -Ubatt 11: Errormode not identifiable 11: Errormode not identifiable
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Wrong voltage of internal 5V reference source 3, operating voltage too high or too low, connection cable demaged, ECU defective
Corrective Action
If error not removable, change ECU, check cabling of external components, check working voltage and if necessary correct it, check connection cable and if necessary repair or replace it
Others Error Properties
Priority 3, self healing, as measured value a current value will be showed.
StrtCDHS
Error Description
Start relay (high side power stage): the current drain measured by ECU is above the target range
Error Codes
DEUTZ: 223, Blink: 5-1-2, SPN: 677, FMI (Bit 0,1,2,3): 3: Voltage to high or short circuit to +Ubatt 4: Voltage to low or short circuit to -Ubatt 11: Errormode not identifiable 11: Errormode not identifiable
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Start relay (high side): short circuit, relay defective, conncection cable defective
Corrective Action
Check cabling and start relay and if necessary replace it, check connection cable and if necessary repair or replace it
Others Error Properties
Priority 1, not self healing, as measured value a default value will be showed.
To First Page
DEUTZ A
G, VS-TA, Fi, Su Page 55 von 67 Rev. 2.0
DTC - List
Diagnosis- and Fehlercodes
Referenced ECU Software P490_: 220, 310, 501 P491_: 220, 310, 400, 501
P492_: 213 P513_: 214, 300
StrtCDLS
Error Description
start relay (low side power stage): the current drain measured by ECU is out of the target range
Error Codes
DEUTZ: 224, Blink: 5-1-2, SPN: 677, FMI (Bit 0,1,2,3): 3: Voltage to high or short circuit to +Ubatt 4: Voltage to low or short circuit to -Ubatt 5: current to low or broken wire 11: Errormode not identifiable
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Start relay (low side): cable break or short circuit, disabled by ECU, relay defective, connection cable demaged
Corrective Action
Check cabling and start relay and if necessary replace it, check connection cable and if necessary repair or replace it
Others Error Properties
Priority 1, not self healing, as measured value a default value will be showed.
SysLamp
Error Description
Error lamp (diagnositic lamp): the current drain measured by ECU is out of the target range or the maximum permissble temperature of the ECU component for power supply of the lamp is exceeded
Error Codes
DEUTZ: 225, Blink: 5-1-3, SPN: 624, FMI (Bit 0,1,2,3): 3: Voltage to high or short circuit to +Ubatt 4: Voltage to low or short circuit to -Ubatt 5: current to low or broken wire 2: data stream is defective
Error Detection
- of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Cable break or short circuit, disabled by ECU, lamp defective, connection cable demaged
Corrective Action
Check cabling and load, check lamp and if necessary replace it, check connection cable and if necessary repair or replace it
Others Error Properties
Priority 2, not self healing, as measured value a nominal value of diagnostic lamp will be showed.
T15CD
Error Description
Terminal 15: ECU receives no signal
Error Codes
DEUTZ: 226, Blink: 5-1-4, SPN: 158, FMI (Bit 0,1,2,3): 11: Errormode not identifiable 11: Errormode not identifiable 12: Defective component 11: Errormode not identifiable
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Ignition ON not detected, ignition switch defective, connection cable demaged
Corrective Action
Check cabling, if sensor not working, check ignition switch and if necessary replace it, check connection cable and if necessary repair or replace it
Others Error Properties
Priority 2, not self healing, as measured value a current value will be showed.
To First Page
DEUTZ A
G, VS-TA, Fi, Su Page 56 von 67 Rev. 2.0
DTC - List
Diagnosis- and Fehlercodes
Referenced ECU Software P490_: 220, 310, 501 P491_: 220, 310, 400, 501
P492_: 213 P513_: 214, 300
T50CD
Error Description
Terminal 50: ECU receives a permanent signal
Error Codes
DEUTZ: 227, Blink: 5-1-5, SPN: 523550, FMI (Bit 0,1,2,3): 12: Defective component 11: Errormode not identifiable 11: Errormode not identifiable 11: Errormode not identifiable
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Engine start switch stuck, start switch clamped, connection cable demaged
Corrective Action
Check cabling, if sensor not working, check start switch and if necessary replace it, check connection cable and if necessary repair or replace it
Others Error Properties
Priority 1, not self healing, as measured value a current value will be showed.
TPUMon
Error Description
Internal hardware monitoring: ECU detects a deviation between the signal of time module and the system time
Error Codes
DEUTZ: 228, Blink: 5-5-5, SPN: 523550, FMI (Bit 0,1,2,3): 11: Errormode not identifiable 11: Errormode not identifiable 11: Errormode not identifiable 2: data stream is defective
Error Detection
Blink of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Time processing unit (TPU) defective, ECU defective
Corrective Action
If error not removable, change ECU
Others Error Properties
Priority 5, not self healing, as measured value a - will be showed.
VSSCD1
Error Description
Vehicle speed: over the maximum, signal invalid or implausible compared with the injection quantity and the engine speed, offset factors unlearned
Error Codes
DEUTZ: 232, Blink: 5-2-1, SPN: 84, FMI (Bit 0,1,2,3): 0: data valid, but above normal working area 12: Defective component 8: unusual frequency, pulse or period. 14: Special Instructions
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Speed above target range, signal invalid or implausible compared to injection volume and engine speed, distance factor not learned, sensor defective, connection cable demaged
Corrective Action
Check cabling, if sensor not working, check sensor and if necessary replace it, check connection cable and if necessary repair or replace it
DEUTZ A
Others Error Properties
Priority 3, self healing, as measured value a default value will be showed.
To First Page
G, VS-TA, Fi, Su Page 57 von 67 Rev. 2.0
DTC - List
Diagnosis- and Fehlercodes
Referenced ECU Software P490_: 220, 310, 501 P491_: 220, 310, 400, 501
P492_: 213 P513_: 214, 300
WdCom
Error Description
Internal hardware monitoring: the ECU detects a disturbance in internal communication
Error Codes
DEUTZ: 235, Blink: 5-5-5, SPN: 523600, FMI (Bit 0,1,2,3): 11: Errormode not identifiable 11: Errormode not identifiable 11: Errormode not identifiable 12: Defective component
Error Detection
Blink of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Communication disturbed, ECU defective
Corrective Action
If error not to removable, change ECU
Others Error Properties
Priority 5, not self healing, as measured value a - will be showed.
PRVMonSysReac
Error Description
Rail pressure relief valve: is open, will be forced to open, the forced-open failed; the ECU activates a system reaction
Error Codes
DEUTZ: 236, Blink: 1-4-6, SPN: 523470, FMI (Bit 0,1,2,3): 12: Defective component 12: Defective component 11: Errormode not identifiable 11: Errormode not identifiable
Error Detection
Continuous light, 15s blink before shut off of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Rail pressure relief valve open or forced open abortive (interpretation of the rail pressure gradient), power supply voltage too low, rail pressure sensor defective, fuel metering unit defective, rail pressure relief valve defective, air in fuel system
Corrective Action
Check working voltage and if necessary correct it, check rail-pressure sensor and if necessary replace it, check FCU and if necessary replace it, check rail pressure relief valve and if necessary replace it, bleed the fuel-system
APPCDSwtnSel
Error Description
Controller mode switch: the signal received by ECU is defective or implausible.
Error Codes
DEUTZ: 237, Blink: 2-4-2, SPN: 523006, FMI (Bit 0,1,2,3): 3: Voltage to high or short circuit to +Ubatt 4: Voltage to low or short circuit to -Ubatt 2: data stream is defective 11: Errormode not identifiable
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Cable break, signal implausible, switch defective, connection cable demaged
Corrective Action
Check switch and if necessary replace it, check connection cable and if necessary repair or replace it
Others Error Properties
Priority 2, self healing, as measured value a current value will be showed.
To First Page
DEUTZ A
Others Error Properties
Priority 4, not self healing, as measured value a current value will be showed.
G, VS-TA, Fi, Su Page 58 von 67 Rev. 2.0
DTC - List
Diagnosis- and Fehlercodes
Referenced ECU Software P490_: 220, 310, 501 P491_: 220, 310, 400, 501
P492_: 213 P513_: 214, 300
FrmMng_TORxEngPress
Error Description
CAN message EngPress (Engine Pressure): the message cannot be received by ECU
Error Codes
DEUTZ: 238, Blink: 2-1-5, SPN: 523007, FMI (Bit 0,1,2,3): 12: Defective component 11: Errormode not identifiable 11: Errormode not identifiable 11: Errormode not identifiable
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Missing message "RxEngPress" = engine pressure; CAN bus wrong cabled, wiring is damaged, receiver (sender of the message) work inaccurately, parametering inaccurate
Corrective Action
Check CAN Bus cabling (Bus scheduling, polarity, short circuit, power interrupt), test protocol of receiver, check CAN functional range
Others Error Properties
Priority 1, self healing, as measured value a default value will be showed.
MplCtl
Error Description
Data monitoring: the torque curve does not match the specification
Error Codes
DEUTZ: 239, Blink: 4-2-4, SPN: 523008, FMI (Bit 0,1,2,3): 1: data valid, but below normal working area 2: data stream is defective 11: Errormode not identifiable 11: Errormode not identifiable
Error Detection
0 of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Manipulation of Topcurve detected, data manipulation, too slow changed curve
Corrective Action
Others Error Properties
Priority 3, not self healing, as measured value a 0 will be showed.
OLSCD
Error Description
Oil level sensor: the voltage of sensor measured by ECU is out of the target range or the received value of oil level via CAN is defective or the signal value is implausible
Error Codes
DEUTZ: 240, Blink: 2-1-1, SPN: 98, FMI (Bit 0,1,2,3): 3: Voltage to high or short circuit to +Ubatt 4: Voltage to low or short circuit to -Ubatt 2: data stream is defective 2: data stream is defective
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Voltage outside target range, CAN signal error, signal implausible, sensor defective, connection cable demaged, CAN bus wrong cabled, wiring demaged, receiver (sender of the message) work inaccurately, parametering inaccurate
Corrective Action
Check cabling, if sensor not working, check sensor and if necessary replace it, check connection cable and if necessary repair or replace it, Check CAN Bus cabling (Bus sheduling, polarity, short circuit, power interrupt), test protocol of receiver, chec
DEUTZ A
Others Error Properties
Priority 3, self healing, as measured value a default value will be showed.
To First Page
G, VS-TA, Fi, Su Page 59 von 67 Rev. 2.0
DTC - List
Diagnosis- and Fehlercodes
Referenced ECU Software P490_: 220, 310, 501 P491_: 220, 310, 400, 501
P492_: 213 P513_: 214, 300
OLSCDSysReacHi
Error Description
Oil level: the oil level calculated by ECU is above the target range; the ECU activates a system reaction
Error Codes
DEUTZ: 241, Blink: 2-5-1, SPN: 98, FMI (Bit 0,1,2,3): 0: data valid, but above normal working area 11: Errormode not identifiable 11: Errormode not identifiable 11: Errormode not identifiable
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Oil level too high with system reaction, oil volume too large, sensor defective, connection cable demaged, CAN data error
Corrective Action
Check oil level and if necessary correct it, check sensor and if necessary replace it, check connection cable and if necessary repair or replace it
Others Error Properties
Priority 4, self healing, as measured value a current value will be showed.
ADPSCDAna
Error Description
Air filter differential pressure sensor: the voltage of sensor measured by ECU is out of the target range
Error Codes
DEUTZ: 242, Blink: 1-3-6, SPN: 107, FMI (Bit 0,1,2,3): 3: Voltage to high or short circuit to +Ubatt 4: Voltage to low or short circuit to -Ubatt 11: Errormode not identifiable 11: Errormode not identifiable
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Voltage outside target range, sensor defective, connection cable demaged
Corrective Action
Check cable harness, check sensor and if necessary replace it, check connection cable and if necessary repair or replace it
Others Error Properties
Priority 3, self healing, as measured value a default value will be showed.
OLSCDSysReacLo
Error Description
Oil level: the oil level calculated by ECU is underneath the target range; the ECU activates a system reaction
Error Codes
DEUTZ: 243, Blink: 2-5-2, SPN: 98, FMI (Bit 0,1,2,3): 1: data valid, but below normal working area 11: Errormode not identifiable 11: Errormode not identifiable 11: Errormode not identifiable
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Oil level too low with system reaction, oil volume too small, sensor defective, connection cable demaged, CAN data error
Corrective Action
Check oil level and if necessary correct it, check sensor and if necessary replace it, check connection cable and if necessary repair or replace it
Others Error Properties
Priority 4, self healing, as measured value a current value will be showed.
To First Page
DEUTZ A
G, VS-TA, Fi, Su Page 60 von 67 Rev. 2.0
DTC - List
Diagnosis- and Fehlercodes
Referenced ECU Software P490_: 220, 310, 501 P491_: 220, 310, 400, 501
P492_: 213 P513_: 214, 300
PrvMonWear
Error Description
Rail pressure relief valve: is open more frequently or for a longer time than what the technical specification allows
Error Codes
DEUTZ: 244, Blink: 2-5-3, SPN: 523009, FMI (Bit 0,1,2,3): 9: Abnormal update rated 10: Abnormal rate of change 14: Special Instructions 11: Errormode not identifiable
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Rail pressure relief valve open more frequently than the technical specification allowed, rail pressure relief valve open longer than the technical specification allowed, rail pressure relief valve defective
Corrective Action
Change rail pressure relief valve and remove the error through Serdia command
Others Error Properties
Priority 3, not self healing, as measured value a current value will be showed.
RailMeUn8
Error Description
Wenn the engine is in idle running, the metering unit compares its output and rail pressure with the default value (Parameter) and calculates a correction factor-it calibrates itself then
Error Codes
DEUTZ: 245, Blink: 2-5-4, SPN: 523010, FMI (Bit 0,1,2,3): 0: data valid, but above normal working area 11: Errormode not identifiable 11: Errormode not identifiable 11: Errormode not identifiable
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Corrective Action
Others Error Properties
Priority 3, not self healing, as measured value a current value will be showed.
FlSys_FLPFMSysReac
Error Description
Error Codes
DEUTZ: 246, Blink: 5-4-1, SPN: 523650, FMI (Bit 0,1,2,3): 2: data stream is defective 2: data stream is defective 11: Errormode not identifiable 11: Errormode not identifiable
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Corrective Action
Others Error Properties
Priority 4, self healing, as measured value a default value will be showed.
To First Page
DEUTZ A
G, VS-TA, Fi, Su Page 61 von 67 Rev. 2.0
DTC - List
Diagnosis- and Fehlercodes
Referenced ECU Software P490_: 220, 310, 501 P491_: 220, 310, 400, 501
P492_: 213 P513_: 214, 300
FlSys_FTSFMSysReac
Error Description
Error Codes
DEUTZ: 247, Blink: 5-4-2, SPN: 523651, FMI (Bit 0,1,2,3): 2: data stream is defective 2: data stream is defective 11: Errormode not identifiable 11: Errormode not identifiable
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Corrective Action
Others Error Properties
Priority 3, self healing, as measured value a default value will be showed.
FlSys_FlushStateEngineOff
Error Description
Error Codes
DEUTZ: 248, Blink: 5-4-3, SPN: 523652, FMI (Bit 0,1,2,3): 2: data stream is defective 11: Errormode not identifiable 11: Errormode not identifiable 11: Errormode not identifiable
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Corrective Action
Others Error Properties
Priority 3, self healing, as measured value a - will be showed.
FlSys_RapeOilHeatEx
Error Description
Error Codes
DEUTZ: 249, Blink: 5-4-4, SPN: 523653, FMI (Bit 0,1,2,3): 2: data stream is defective 11: Errormode not identifiable 11: Errormode not identifiable 11: Errormode not identifiable
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
Corrective Action
Others Error Properties
Priority 3, self healing, as measured value a - will be showed.
To First Page
DEUTZ A
G, VS-TA, Fi, Su Page 62 von 67 Rev. 2.0
DTC - List
Diagnosis- and Fehlercodes
Referenced ECU Software P490_: 220, 310, 501 P491_: 220, 310, 400, 501
P492_: 213 P513_: 214, 300
FrmMngDieselLvl
Error Description
CAN message DieselLvl (Diesel tank level): the message can not be received by ECU
Error Codes
DEUTZ: 250, Blink: 5-4-5, SPN: 523654, FMI (Bit 0,1,2,3): 3: Voltage to high or short circuit to +Ubatt 4: Voltage to low or short circuit to -Ubatt 11: Errormode not identifiable 11: Errormode not identifiable
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
CAN bus wrong cabled, wiring is demaged, receiver (sender of the message) work inaccurately, parametering inaccurate
Corrective Action
Check CAN Bus cabling (Bus sheduling, polarity, short circuit, power interrupt), test protocol of receiver, check CAN functional range
FrmMngFuelTemp
Error Description
CAN message FuelTemp (Fuel Temperature): the message can not be received by ECU
Error Codes
DEUTZ: 251, Blink: 5-4-6, SPN: 523655, FMI (Bit 0,1,2,3): 3: Voltage to high or short circuit to +Ubatt 4: Voltage to low or short circuit to -Ubatt 11: Errormode not identifiable 11: Errormode not identifiable
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
CAN bus wrong cabled, wiring is demaged, receiver (sender of the message) work inaccurately, parametering inaccurate
Corrective Action
Check CAN Bus cabling (Bus sheduling, polarity, short circuit, power interrupt), test protocol of receiver, check CAN functional range
FrmMngLowPressureDiesel
Error Description
CAN message LowPressureDiesel (Low fuel pressure diesel): the message can not be received by ECU
Error Codes
DEUTZ: 252, Blink: 5-4-7, SPN: 523656, FMI (Bit 0,1,2,3): 3: Voltage to high or short circuit to +Ubatt 4: Voltage to low or short circuit to -Ubatt 11: Errormode not identifiable 11: Errormode not identifiable
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
CAN bus wrong cabled, wiring is demaged, receiver (sender of the message) work inaccurately, parametering inaccurate
Corrective Action
Check CAN Bus cabling (Bus sheduling, polarity, short circuit, power interrupt), test protocol of receiver, check CAN functional range
Others Error Properties
Priority 3, self healing, as measured value a default value will be showed.
DEUTZ A
G, VS-TA, Fi, Su Page 63 von 67 Rev. 2.0
Others Error Properties
Priority 3, self healing, as measured value a default value will be showed.
Others Error Properties
Priority 3, self healing, as measured value a default value will be showed.
To First Page
DTC - List
Diagnosis- and Fehlercodes
Referenced ECU Software P490_: 220, 310, 501 P491_: 220, 310, 400, 501
P492_: 213 P513_: 214, 300
FrmMngRapeOilIn
Error Description
CAN messageRapeOilln (Rape oil input): the message can not be received by ECU
Error Codes
DEUTZ: 253, Blink: 5-6-1, SPN: 523657, FMI (Bit 0,1,2,3): 12: Defective component 11: Errormode not identifiable 12: Defective component 11: Errormode not identifiable
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
CAN bus wrong cabled, wiring is demaged, receiver (sender of the message) work inaccurately, parametering inaccurate
Corrective Action
Check CAN Bus cabling (Bus sheduling, polarity, short circuit, power interrupt), test protocol of receiver, check CAN functional range
FrmMngRapeOilLvl
Error Description
CAN message RapeOilLvl (Rape oil tank level): the message can not be received by ECU
Error Codes
DEUTZ: 254, Blink: 5-6-2, SPN: 523658, FMI (Bit 0,1,2,3): 3: Voltage to high or short circuit to +Ubatt 4: Voltage to low or short circuit to -Ubatt 11: Errormode not identifiable 11: Errormode not identifiable
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
CAN bus wrong cabled, wiring is demaged, receiver (sender of the message) work inaccurately, parametering inaccurate
Corrective Action
Check CAN Bus cabling (Bus sheduling, polarity, short circuit, power interrupt), test protocol of receiver, check CAN functional range
FrmMngRapeOilVlv1
Error Description
CAN message OilVlv1 (Valve 1): the message can not be received by ECU
Error Codes
DEUTZ: 255, Blink: 5-6-3, SPN: 523659, FMI (Bit 0,1,2,3): 11: Errormode not identifiable 11: Errormode not identifiable 12: Defective component 11: Errormode not identifiable
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
CAN bus wrong cabled, wiring is demaged, receiver (sender of the message) work inaccurately, parametering inaccurate
Corrective Action
Check CAN Bus cabling (Bus sheduling, polarity, short circuit, power interrupt), test protocol of receiver, check CAN functional range
Others Error Properties
Priority 3, self healing, as measured value a default value will be showed.
DEUTZ A
G, VS-TA, Fi, Su Page 64 von 67 Rev. 2.0
Others Error Properties
Priority 3, self healing, as measured value a default value will be showed.
Others Error Properties
Priority 3, self healing, as measured value a default value will be showed.
To First Page
DTC - List
Diagnosis- and Fehlercodes
Referenced ECU Software P490_: 220, 310, 501 P491_: 220, 310, 400, 501
P492_: 213 P513_: 214, 300
FrmMngRapeOilVlv2
Error Description
CAN message OilVlv2 (Valve 2): the message can not be received by ECU
Error Codes
DEUTZ: 256, Blink: 5-6-4, SPN: 523660, FMI (Bit 0,1,2,3): 11: Errormode not identifiable 11: Errormode not identifiable 12: Defective component 11: Errormode not identifiable
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
CAN bus wrong cabled, wiring is demaged, receiver (sender of the message) work inaccurately, parametering inaccurate
Corrective Action
Check CAN Bus cabling (Bus sheduling, polarity, short circuit, power interrupt), test protocol of receiver, check CAN functional range
FrmMngRapeOilVlv3
Error Description
CAN message OilVlv3 (Valve 3): the message can not be received by ECU
Error Codes
DEUTZ: 257, Blink: 5-6-5, SPN: 523661, FMI (Bit 0,1,2,3): 11: Errormode not identifiable 11: Errormode not identifiable 12: Defective component 11: Errormode not identifiable
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
CAN bus wrong cabled, wiring is demaged, receiver (sender of the message) work inaccurately, parametering inaccurate
Corrective Action
Check CAN Bus cabling (Bus sheduling, polarity, short circuit, power interrupt), test protocol of receiver, check CAN functional range
FrmMngRapeOilVlv4
Error Description
CAN message OilVlv4 (Valve 4): the message can not be received by ECU
Error Codes
DEUTZ: 258, Blink: 5-6-6, SPN: 523662, FMI (Bit 0,1,2,3): 11: Errormode not identifiable 11: Errormode not identifiable 12: Defective component 11: Errormode not identifiable
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
CAN bus wrong cabled, wiring is demaged, receiver (sender of the message) work inaccurately, parametering inaccurate
Corrective Action
Check CAN Bus cabling (Bus sheduling, polarity, short circuit, power interrupt), test protocol of receiver, check CAN functional range
Others Error Properties
Priority 3, self healing, as measured value a default value will be showed.
DEUTZ A
G, VS-TA, Fi, Su Page 65 von 67 Rev. 2.0
Others Error Properties
Priority 3, self healing, as measured value a default value will be showed.
Others Error Properties
Priority 3, self healing, as measured value a default value will be showed.
To First Page
DTC - List
Diagnosis- and Fehlercodes
Referenced ECU Software P490_: 220, 310, 501 P491_: 220, 310, 400, 501
P492_: 213 P513_: 214, 300
FrmMngRapeOilVlv5
Error Description
CAN message OilVlv5 (Valve 5): the message can not be received by ECU
Error Codes
DEUTZ: 259, Blink: 5-6-7, SPN: 523663, FMI (Bit 0,1,2,3): 11: Errormode not identifiable 11: Errormode not identifiable 12: Defective component 11: Errormode not identifiable
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
CAN bus wrong cabled, wiring is demaged, receiver (sender of the message) work inaccurately, parametering inaccurate
Corrective Action
Check CAN Bus cabling (Bus sheduling, polarity, short circuit, power interrupt), test protocol of receiver, check CAN functional range
FrmMngSTIN1RX
Error Description
CAN message STIN1 (State Inputs 1): the message can not be received by ECU
Error Codes
DEUTZ: 260, Blink: 5-6-8, SPN: 523664, FMI (Bit 0,1,2,3): 12: Defective component 11: Errormode not identifiable 12: Defective component 11: Errormode not identifiable
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
CAN bus wrong cabled, wiring is demaged, receiver (sender of the message) work inaccurately, parametering inaccurate
Corrective Action
Check CAN Bus cabling (Bus sheduling, polarity, short circuit, power interrupt), test protocol of receiver, check CAN functional range
FrmMngStEKP
Error Description
CAN message StEKP (State Electrical Fuel Supply Pump): the message can not be received by ECU
Error Codes
DEUTZ: 261, Blink: 5-6-9, SPN: 523665, FMI (Bit 0,1,2,3): 11: Errormode not identifiable 11: Errormode not identifiable 12: Defective component 11: Errormode not identifiable
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
CAN bus wrong cabled, wiring is demaged, receiver (sender of the message) work inaccurately, parametering inaccurate
Corrective Action
Check CAN Bus cabling (Bus sheduling, polarity, short circuit, power interrupt), test protocol of receiver, check CAN functional range
Others Error Properties
Priority 3, self healing, as measured value a default value will be showed.
DEUTZ A
G, VS-TA, Fi, Su Page 66 von 67 Rev. 2.0
Others Error Properties
Priority 3, self healing, as measured value a default value will be showed.
Others Error Properties
Priority 3, self healing, as measured value a default value will be showed.
To First Page
DTC - List
Diagnosis- and Fehlercodes
FrmMngStLmp
Referenced ECU Software P490_: 220, 310, 501 P491_: 220, 310, 400, 501
FrmMngStOutRx
P492_: 213 P513_: 214, 300
Error Description
CAN message StLmp (State Lamp): the message can not be received by ECU
Error Codes
DEUTZ: 262, Blink: 5-7-1, SPN: 523666, FMI (Bit 0,1,2,3): 11: Errormode not identifiable 11: Errormode not identifiable 12: Defective component 11: Errormode not identifiable
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
CAN bus wrong cabled, wiring is demaged, receiver (sender of the message) work inaccurately, parametering inaccurate
Corrective Action
Check CAN Bus cabling (Bus sheduling, polarity, short circuit, power interrupt), test protocol of receiver, check CAN functional range
Others Error Properties
Priority 3, self healing, as measured value a default value will be showed.
Error Description
CAN message StOut (State Outputs): the message can not be received by ECU
Error Codes
DEUTZ: 263, Blink: 5-7-2, SPN: 523667, FMI (Bit 0,1,2,3): 12: Defective component 11: Errormode not identifiable 12: Defective component 11: Errormode not identifiable
Error Detection
Continuous light of the fault lamp, registered in the error memory of the ECU.
Possible Error Reason
CAN bus wrong cabled, wiring is demaged, receiver (sender of the message) work inaccurately, parametering inaccurate
Corrective Action
Check CAN Bus cabling (Bus sheduling, polarity, short circuit, power interrupt), test protocol of receiver, check CAN functional range
Others Error Properties
Priority 3, self healing, as measured value a default value will be showed
DEUTZ A
To First Page
G, VS-TA, Fi, Su Page 67 von 67 Rev. 2.0