Delfield SSF2-SH25-209 User Manual

5 (1)
Delfield SSF2-SH25-209 User Manual

Delfield®

Specification Line®

Installation, Use and Care Manual

Please read this manual completely before attempting to install or operate this equipment! Notify carrier of damage! Inspect all components immediately. See page 3.

IMPORTANT

INFORMATION

 

 

USE

 

READ

BEFORE

 

 

 

 

INSTRUCTIONS!

 

SAVE

THESE

PLEASE

 

 

 

 

 

 

 

 

 

 

 

 

 

June 2011

Delfield

Important Warning And Safety Information

WARNING

Read this manual thoroughly before operating, installing, or performing maintenance on the equipment.

FAILURE TO FOLLOW INSTRUCTIONS IN THIS MANUAL CAN CAUSE PROPERTY DAMAGE, INJURY OR DEATH.

DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS OR LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE.

UNLESS ALL COVER AND ACCESS PANELS ARE IN PLACE AND PROPERLY SECURED, DO NOT OPERATE THIS EQUIPMENT.

DAMP OR WET HANDS MAY STICK TO COLD SURFACES.

ALLOW HEATED EQUIPMENT TO COOL DOWN BEFORE ATTEMPTING TO CLEAN OR SERVICE.

CAUTION

Observe the following:

Minimum clearances must be maintained.

Keep the equipment area free and clear of combustible material.

Allow adequate clearance for air openings.

Operate equipment only on the type of electricity indicated on the specification plate.

Unplug the unit before making any repairs.

Retain this manual for future reference.

2

Specification Line

Contents

 

Serial Number........................................................................

3

Receiving And Inspecting The Equipment.............................

3

Model Numbers.....................................................................

4

Introduction...........................................................................

5

Specifications..................................................................

6-12

Installation.....................................................................

13-14

Electronic Temperature Control Operation.....................

15-16

Evaporator Fan Operation....................................................

16

Door Reversal Procedures...................................................

17

Heated Cabinet Operation....................................................

18

Maintenance..................................................................

19-20

Wiring Diagrams............................................................

21-28

Compressor Diagrams.........................................................

29

Replacement Parts........................................................

30-34

Standard Labor Guidelines..................................................

35

Standard Two Year Warranty...............................................

36

Additional Three Year Warranty...........................................

37

Notes.............................................................................

38-39

Serial Number Location

The serial number is on the identification plate that also includes the model number. On refrigeration and freezer units the identification plate is located inside the left most door near the top front corner of the left interior wall. On heated units, the identification plate is located in the shroud area on the right side panel.

Always have the serial number of your unit available when calling for parts or service. A complete list of authorized Delfield parts depots can be found at www.delfield.com.

©2011 The Delfield Company. All rights reserved. Reproduction without written permission is prohibited. “Delfield” is a registered trademark of The Delfield Company.

Receiving And Inspecting The Equipment

Even though most equipment is shipped crated, care should be taken during unloading so the equipment is not damaged while being moved into the building.

1.Visually inspect the exterior of the package an skid or container. Any damage should be noted and reported to the delivering carrier immediately.

2.If damaged, open and inspect the contents with the carrier.

3.In the event that the exterior is not damaged, yet upon opening, there is concealed damage to the equipment notify the carrier. Notification should be made verbally as well as in written form.

4.Request an inspection of the concealed equipment. This should be done within 10 days from receipt of the equipment.

5.Check the lower portion of the unit to be sure legs or casters are not bent.

6.Also open the compressor compartment housing and visually inspect the refrigeration package. Be sure lines are secure and base is still intact.

7.Freight carriers can supply the necessary forms upon request.

8.Retain all crating material until an inspection has been made or waived.

Uncrating the Equipment

First cut and remove the banding from around the crate. Remove the front of the crate material, use of some tools will be required. If the unit is on legs remove the top of the crate as well and lift the unit off the skid. If the unit is on casters it can be "rolled" off the skid.

3

Delfield

Model Numbers

Series

Finish

Temp

Configuration

Section

Size

System

Doors

 

 

 

 

 

 

 

 

S=Specification

S=Stainless interior &

R=Refrigerator

None=Reach-in

1=1 Section

None=Standard

None=Standard

S=Solid Full

Line

exterior

F=Freezer

PT=Pass Thru

2=2 Section

N=Narrow

E=Export Voltage

SH=Solid Half

 

A=Stainless exterior,

H=Heated

RI=Roll-in

3=3 Section

S=Shallow

R=Remote

G=Hinged Glass Full

 

aluminum interior

D=Dual Temp

RT=Roll Thru

 

 

 

GH=Hinged Glass Half

 

M=Stainless front,

 

FF=Fish Drawers

 

 

 

SL=Sliding Glass Full

 

aluminum sides and

 

RL=Refrigerator Left

 

 

 

SLH=Sliding Glass Half

 

interior

 

FL=Freezer Left

 

 

 

SLS=Sliding Solid Full

 

 

 

TR=Top Refrigerator

 

 

 

SLSH=Sliding Solid Half

 

 

 

BR=Bottom Refrigerator

 

 

 

D=Drawers

 

 

 

TP=Top Refrigerator Pass Thru

 

 

 

 

 

 

 

BP=Bottom Refrigerator Pass Thru

 

 

 

 

 

 

 

RP=Refrigerator Left Pass Thru

 

 

 

 

 

 

 

FP=Freezer Left Pass Thru

 

 

 

 

 

 

 

 

 

 

 

 

4

Specification Line

Introduction

Model numbers starting with the letters “SS” have a stainless steel exterior and interior. Model numbers starting with the letters “SA” have an aluminum interior and a stainless steel exterior. Model numbers starting with the letters “SM” have an aluminum interior and exterior with a stainless steel front and shroud. Door gaskets are magnetic and mount to the door, snapping in place and are removable without tools. Keyed door lock is mounted in the door next to the handle.

Doors can be removed from the cabinet without the use of tools. Each door has two edge mount, self-closing, cam lift style hinges.

Refrigeration System

All components are mounted to the exterior cabinet ceiling, outside the food zone and are assembled as one-piece and can be removedasone-piece.EnvironmentallyfriendlyR404Arefrigerant is used. The system has the capability of maintaining between 33°F and 40°F (1°C and 4°C) in heavy use food service operations. Refrigerant is metered using a highly responsive thermostatic expansion valve. Systems are controlled using Delfield’s ACT Electronic Temperature Control. It provides improved pull down times, reducing compressor cycling and longer compressor life with lower energy consumption. Control system uses adaptive defrost to assure evaporator coil is free of ice and operating at optimum efficiency. Evaporator condensate is eliminated using an energy efficient hot gas system.

Freezer Refrigeration System

All components are mounted to the exterior cabinet ceiling, outside the food zone and are assembled as one-piece and can be removed as one-piece. Environmentally friendly R404A refrigerant is used. The system has the capability of maintaining between -5°F and 0°F (-21°C and -18°C) in heavy use food service operations. Refrigerant is metered using a highly responsive thermostatic expansion valve. System is controlled using Delfield’s ACT Electronic Temperature Control, which provides improved pull down times, reducing compressor cycling and longer compressor life with lower energy consumption. Control system uses adaptive defrost to assure evaporator coil is free of ice and operating at optimum efficiency. Evaporator condensate is eliminated using an energy efficient hot gas system.

Heating System

Heating system cabinets are designed to maintain temperatures between 120°F and 200°F (49°C and 93°C). Heating elements are helical shaped, with tubular fins. A circulating fan provides uniform airflow in the cabinet. The entire heating system is mounted to the exterior of the cabinet ceiling, outside the food zone. It is assembled as one piece and can be removed as one piece. An adjustable electronic thermostat controls temperature. The system ON/OFF switch is located on the front exterior of the cabinet.

Service Alert

During normal operation the evaporator fan may cycle and/or pulse independently of the compressor. Consult the service manual or contact Technical Support at 1-800-733-8829 if you are unsure of the proper function.

Dual Temperature Refrigeration/Freezer

Each compartment has its own separate refrigeration system. Condensingunitsarelocatedontopofthecabinet,outsidethefood zone, behind the upper shroud. Evaporator coils are located inside the cabinet mounted to the interior ceiling of each compartment. Defrost is automatic. Condensate travels down a tube in the cabinet sidewall to a receptacle mounted to the exterior bottom of the cabinet where it evaporates with the aid of an electric heater. Each compartment’s temperature is individually monitored and controlledwithDelfield'sACTElectronicTemperatureControl.Two exterior digital thermometers monitor temperature. Refrigerator compartment maintains temperature between 33°F and 41°F (1°C and 5°C). Freezer compartment maintains temperature between -5°F and +5°F (-21°C and -15°C). Refrigerant is metered using a highly responsive thermostatic expansion valve.

5

Delfield

Specifications

Reach-In Refrigerators - Hinged Doors - Standard Width & Depth

 

 

 

Storage

Shelf

No. Of

 

 

R-404A

Shipping

NEMA

Energy

Model

Voltage

Amps

Capacity

Capacity

H.P.

BTU/HR

Shelves

Charge Oz.

Weight

Plug

(KWH)

 

 

 

Ft3

Ft2

 

 

 

 

 

 

 

 

 

 

 

 

SSR1-S,SH,G,GH

115

6.0

24.96

12.81

3

1/4

2092

12.5

418lbs/

5-15P

2.64

SAR1-S,SH,G,GH

 

 

 

 

 

 

 

 

190kg

 

 

SMR1-S,SH,G,GH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SSR2-S,SH,G,GH

115

9.5

51.92

27.54

6

1/3

3226

19

650lbs/

5-15P

4.51

SAR2-S,SH,G,GH

 

 

 

 

 

 

 

 

295kg

 

 

SMR2-S,SH,G,GH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SSR3-S,SH,G,GH

115

14.5

78.89

42.47

9

1/2

5465

24

830lbs/

5-20p

5.51

SAR3-S,SH,G,GH

 

 

 

 

 

 

 

 

376kg

 

 

SMR3-S,SH,G,GH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Reach-In Refrigerators - Hinged Doors - Narrow Width

 

 

 

Storage

Shelf

No. Of

H.P.

BTU/HR

R-404A

Shipping

NEMA

Energy

Model

Voltage

Amps

Capacity

Capacity

Shelves

Charge Oz.

Weight

Plug

(KWH)

 

 

 

Ft3

Ft2

 

 

 

 

 

 

 

 

 

 

 

 

SSR1N-S,SH

115

6.8

20.97

10.59

3

1/4

2092

12.5

398lbs/

5-15P

3.16

SAR1N-S,SH

 

 

 

 

 

 

 

 

181kg

 

 

SMR1N-S,SH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SSR1N-G,GH

115

6.8

20.97

10.59

3

1/4

2092

12.5

398lbs/

5-15P

4.04

SAR1N-G,GH

 

 

 

 

 

 

 

 

181kg

 

 

SMR1N-G,GH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SSR2N-S,SH

115

9.0

43.94

23.10

6

1/3

3226

19

588lbs/

5-15P

4.31

SAR2N-S,SH

 

 

 

 

 

 

 

 

267kg

 

 

SMR2N-S,SH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SSR2N-G,GH

115

9.0

43.94

23.10

6

1/3

3226

19

588lbs/

5-15P

5.95

SAR2N-G,GH

 

 

 

 

 

 

 

 

267kg

 

 

SMR2N-G,GH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Reach-In Refrigerators - Hinged Doors - Shallow Depth

 

 

 

Storage

Shelf

No. Of

H.P.

BTU/HR

R-404A

Shipping

NEMA

Energy

Model

Voltage

Amps

Capacity

Capacity

Shelves

Charge Oz.

Weight

Plug

(KWH)

 

 

 

Ft3

Ft2

 

 

 

 

 

 

 

 

 

 

 

 

SSR1S-S,SH

115

6.8

18.25

12.81

3

1/4

2092

12.5

396lbs/

5-15P

2.66

SAR1S-S,SH

 

 

 

 

 

 

 

 

180kg

 

 

SMR1S-S,SH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SSR1S-G,GH

115

6.8

18.25

12.81

3

1/4

2092

12.5

396lbs/

5-15P

3.55

SAR1S-G,GH

 

 

 

 

 

 

 

 

180kg

 

 

SMR1S-G,GH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SSR2S-S,SH

115

7.8

37.96

27.54

6

1/3

2488

19

586lbs/

5-15P

2.98

SAR2S-S,SH

 

 

 

 

 

 

 

 

266kg

 

 

SMR2S-S,SH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SSR2S-G,GH

115

7.8

37.96

27.54

6

1/3

2488

19

586lbs/

5-15P

5.24

SAR2S-G,GH

 

 

 

 

 

 

 

 

266kg

 

 

SMR2S-G,GH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

Specification Line

Specifications, continued

Reach-In Refrigerators - Sliding Doors

 

 

 

Storage

Shelf

No. Of

 

 

R-404A

Shipping

NEMA

Energy

Model

Voltage

Amps

Capacity

Capacity

H.P.

BTU/HR

Shelves

Charge Oz.

Weight

Plug

(KWH)

 

 

 

Ft3

Ft2

 

 

 

 

 

 

 

 

 

 

 

 

SSR2-SLS,SLSH,

115

9.0

51.92

27.54

6

1/3

3226

19

670lbs/

5-15P

N/A

SLG,SLGH

 

 

 

 

 

 

 

 

304kg

 

 

SAR2-SLS,SLSH,

 

 

 

 

 

 

 

 

 

 

 

SLG,SLGH

 

 

 

 

 

 

 

 

 

 

 

SMR2-SLS,SLSH,

 

 

 

 

 

 

 

 

 

 

 

SLG,SLGH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SSR2S-SLS,SLSH,

115

7.8

37.96

27.54

6

1/3

2488

12.5

670lbs/

5-15P

N/A

SLG,SLGH

 

 

 

 

 

 

 

 

304kg

 

 

SAR2S-SLS,SLSH,

 

 

 

 

 

 

 

 

 

 

 

SLG,SLGH

 

 

 

 

 

 

 

 

 

 

 

SMR2S-SLS,SLSH,

 

 

 

 

 

 

 

 

 

 

 

SLG,SLGH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Reach-In Refrigerator/Freezer Combinations - Dual Temps - Hinged Doors - Standard Width & Depth

 

 

 

 

Storage

Shelf

No. Of

 

BTU/

R-404A

Shipping

NEMA

Energy

Model

Section

V

Amps

Capacity

Capacity

H.P.

Charge

Shelves

HR

Weight

Plug

(KWH)

 

 

 

 

Ft3

Ft2

 

Oz.

 

 

 

 

 

 

 

 

 

 

SSDTR1-SH,

Refrigerator

115

12.0

10.81

4.23

2

1/5

1543

11

525lbs/

5-20P

6.95

SSDBR1-SH,

 

 

 

 

 

 

 

 

 

238kg

 

 

SADTR1-SH,

 

 

 

 

 

 

 

 

 

 

 

 

SADBR1-SH,

 

 

 

 

 

 

 

 

 

 

 

 

Freezer

115

 

10.81

4.23

2

1/4

1260

12

 

 

 

SMDTR1-SH,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SMDBR1-SH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SSDTR1-GH,

Refrigerator

115

12.0

10.81

4.23

2

1/5

1543

11

525lbs/

5-20P

N/A

SSDBR1-GH,

 

 

 

 

 

 

 

 

 

238kg

 

 

SADTR1-GH,

 

 

 

 

 

 

 

 

 

 

 

 

SADBR1-GH,

 

 

 

 

 

 

 

 

 

 

 

 

Freezer

115

 

10.81

4.23

2

1/4

1260

12

 

 

 

SMDTR1-GH,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SMDBR1-GH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SSDRL2-S,SH,G,GH

Refrigerator

115

6.8

24.96

12.81

3

1/4

2092

12.5

730lbs/

5-15P

N/A

SSDFL2-S,SH,G,GH

 

 

 

 

 

 

 

 

 

331kg

 

 

SADRL2-S,SH,G,GH

 

 

 

 

 

 

 

 

 

 

 

 

SADFL2-S,SH,G,GH

 

 

 

 

 

 

 

 

 

 

 

 

Freezer

115

7.8

24.96

12.81

3

1/2

1516

12.5

 

5-15P

 

SMDRL2-S,SH,G,GH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SMDFL2-S,SH,G,GH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pass-Thru Refrigerator/Freezer Combinations - Dual Temps - Hinged Doors - Standard Width & Depth

 

 

 

 

Storage

Shelf

No. Of

 

BTU/

R-404A

Shipping

NEMA

Energy

Model

Section

V

Amps

Capacity

Capacity

H.P.

Charge

Shelves

HR

Weight

Plug

(KWH)

 

 

 

 

Ft3

Ft2

 

Oz.

 

 

 

 

 

 

 

 

 

 

SSDRP2-S,SH,

Refrigerator

115

6.8

24.96

12.81

3

1/4

2092

19

730lbs/

5-15P

N/A

SSDFP2-S,SH

 

 

 

 

 

 

 

 

 

331kg

 

 

SADRP2-S,SH,

 

 

 

 

 

 

 

 

 

 

 

 

Freezer

115

11.5

24.96

12.81

3

3/4

1923

12.5

 

5-15P

 

SADFP2-S,SH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SMDRP2-S,SH,

 

 

 

 

 

 

 

 

 

 

 

 

SMDFP2-S,SH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7

Delfield

Specifications, continued

Reach-In Hot Food Cabinets - Hinged Doors - Standard Width & Depth

Model

Voltage

Amps

Storage

Shelf Capacity

No. Of Shelves

Shipping

NEMA

Energy

Capacity Ft3

Ft2

Weight

Plug

(KWH)

 

 

 

 

SSH1-S,SH,G,GH

120/208-240

9.0

24.96

12.81

3

418lbs/190kg

N/A

N/A

SAH1-S,SH,G,GH

 

 

 

 

 

 

 

 

SMH1-S,SH,G,GH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SSH2-S,SH,G,GH

120/208-240

16.0

51.92

27.54

6

650lbs/295kg

N/A

N/A

SAH2-S,SH,G,GH

 

 

 

 

 

 

 

 

SMH2-S,SH,G,GH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SSH3-S,SH,G,GH

120/208-240

17.8

78.89

42.47

9

830lbs/376kg

N/A

N/A

SAH3-S,SH,G,GH

 

 

 

 

 

 

 

 

SMH3-S,SH,G,GH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Reach-In Hot Food Cabinets - Hinged Doors - Narrow Width

Model

Voltage

Amps

Storage

Shelf Capacity

No. Of Shelves

Shipping

NEMA

Energy

Capacity Ft3

Ft2

Weight

Plug

(KWH)

 

 

 

 

SSH2N-S,SH

120/208-240

16.0

43.94

27.54

6

588lbs/267kg

N/A

N/A

SAH2N-S,SH

 

 

 

 

 

 

 

 

SMH2N-S,SH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pass-Thru Hot Food Cabinets - Hinged Doors - Standard Width & Depth

Model

Voltage

Amps

Storage

Shelf Capacity

No. Of Shelves

Shipping

NEMA

Energy

Capacity Ft3

Ft2

Weight

Plug

(KWH)

 

 

 

 

SSHPT1-S,SH

120/208-240

9.0

26.96

12.81

3

398lbs/181kg

N/A

N/A

SAHPT1-S,SH

 

 

 

 

 

 

 

 

SMHPT1-S,SH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SSHPT2-S,SH

120/208-240

16.0

51.92

27.54

6

650lbs/295kg

N/A

N/A

SAHPT2-S,SH

 

 

 

 

 

 

 

 

SMHPT2-S,SH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

Specification Line

Specifications, continued

Reach-In Freezers - Hinged Doors - Standard Width & Depth

 

 

 

Storage

Shelf

No. Of

 

 

R-404A

Shipping

NEMA

Energy

Model

Voltage

Amps

Capacity

Capacity

H.P.

BTU/HR

Charge

Shelves

Weight

Plug

(KWH)

 

 

 

Ft3

Ft2

 

 

Oz.

 

 

 

 

 

 

 

 

 

SSF1-S,SH

115

9.0

24.96

12.81

3

1/2

1516

12.5

440lbs/

5-15p

7.63

SAF1-S,SH

 

 

 

 

 

 

 

 

200kg

 

 

SMF1-S,SH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SSF1-G,GH

115

11.5

24.96

12.81

3

3/4

1923

12.5

440lbs/

5-15p

11.29

SAF1-G,GH

 

 

 

 

 

 

 

 

200kg

 

 

SMF1-G,GH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SSF2-S,SH

115

14.3

51.92

27.54

6

3/4

2648

17

710lbs/

5-20P

15.16

SAF2-S,SH

 

 

 

 

 

 

 

 

322kg

 

 

SMF2-S,SH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SSF2-G,GH

115/

10.0

51.92

27.54

6

1

4793

30

710lbs/

N/A

19.95

SAF2-G,GH

208-230

 

 

 

 

 

 

 

322kg

 

 

SMF2-G,GH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SSF3-S,SH

115/

12.6

78.89

42.47

9

1

4793

30

960lbs/

N/A

16.26

SAF3-S,SH

208-230

 

 

 

 

 

 

 

435kg

 

 

SMF3-S,SH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SSF3-G,GH

115/

11.4

78.89

42.47

9

1

5940

72

960lbs/

N/A

29.07

SAF3-G,GH

208-230

 

 

 

 

 

 

 

435kg

 

 

SMF3-G,GH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Reach-In Freezers - Hinged Doors - Narrow Width

 

 

 

Storage

Shelf

No. Of

 

 

R-404A

Shipping

NEMA

Energy

Model

Voltage

Amps

Capacity

Capacity

H.P.

BTU/HR

Charge

Shelves

Weight

Plug

(KWH)

 

 

 

Ft3

Ft2

 

 

Oz.

 

 

 

 

 

 

 

 

 

SSF1N-S,SH

115

7.8

20.97

10.59

3

1/2

1516

12.5

408lbs/

5-15p

7.58

SAF1N-S,SH

 

 

 

 

 

 

 

 

185kg

 

 

SMF1N-S,SH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SSF2N-S,SH

115

14.3

43.94

23.10

6

3/4

2648

17

680lbs/

5-20P

11.13

SAF2N-S,SH

 

 

 

 

 

 

 

 

308kg

 

 

SMF2N-S,SH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Reach-In Freezers - Hinged Doors - Shallow Depth

 

 

 

Storage

Shelf

No. Of

 

 

R-404A

Shipping

NEMA

Energy

Model

Voltage

Amps

Capacity

Capacity

H.P.

BTU/HR

Charge

Shelves

Weight

Plug

(KWH)

 

 

 

Ft3

Ft2

 

 

Oz.

 

 

 

 

 

 

 

 

 

SSF1S-S,SH

115

7.0

18.25

8.98

3

1/2

1516

12.5

406lbs/

5-15p

8.04

SAF1S-S,SH

 

 

 

 

 

 

 

 

184kg

 

 

SMF1S-S,SH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SSF2S-S,SH

115

11.0

37.96

19.04

6

3/4

1923

17

676lbs/

5-15P

10.55

SAF2S-S,SH

 

 

 

 

 

 

 

 

307kg

 

 

SMF2S-S,SH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9

Delfield

Specifications, continued

Pass-Thru Refrigerators - Hinged Doors - Standard Width

 

 

 

Storage

Shelf

No. Of

 

 

R-404A

Shipping

NEMA

Energy

Model

Voltage

Amps

Capacity

Capacity

H.P.

BTU/HR

Shelves

Charge Oz.

Weight

Plug

(KWH)

 

 

 

Ft3

Ft2

 

 

 

 

 

 

 

 

 

 

 

 

SSRPT1-S,SH

115

6.8

26.64

12.81

3

1/4

2092

12.5

455lbs/

5-15P

3.14

SARPT1-S,SH

 

 

 

 

 

 

 

 

206kg

 

 

SMRPT1-S,SH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SSRPT1-G,GH

115

7.8

26.64

12.81

3

1/3

2488

12.5

455lbs/

5-15P

4.58

SARPT1-G,GH

 

 

 

 

 

 

 

 

206kg

 

 

SMRPT1-G,GH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SSRPT2-S,SH

115

16.0

55.42

27.54

6

1/2

5465

24

700lbs/

5-20P

5.96

SARPT2-S,SH

 

 

 

 

 

 

 

 

318kg

 

 

SMRPT2-S,SH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SSRPT2-G,GH

115

16.0

55.42

27.54

6

1/2

5465

24

700lbs/

5-20P

8.16

SARPT2-G,GH

 

 

 

 

 

 

 

 

318kg

 

 

SMRPT2-G,GH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SSRPT3-S,SH

115

16.0

84.19

42.47

9

1/2

5465

24

972lbs/

N/A

8.84

SARPT3-S,SH

 

 

 

 

 

 

 

 

441kg

 

 

SMRPT3-S,SH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SSRPT3-G,GH

115/

12.4

84.19

42.27

9

3/4

7569

48

972lbs/

N/A

14.50

SARPT3-G,GH

208-230

 

 

 

 

 

 

 

441kg

 

 

SMRPT3-G,GH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pass-Thru Refrigerators - Hinged Doors - Shallow Depth

 

 

 

Storage

Shelf

No. Of

 

 

R-404A

Shipping

NEMA

Energy

Model

Voltage

Amps

Capacity

Capacity

H.P.

BTU/HR

Shelves

Charge Oz.

Weight

Plug

(KWH)

 

 

 

Ft3

Ft2

 

 

 

 

 

 

 

 

 

 

 

 

SSRPT1S-S,SH

115

7.8

18.25

8.98

3

1/3

2488

12.5

455lbs/

5-15P

N/A

SARPT1S-S,SH

 

 

 

 

 

 

 

 

206kg

 

 

SMRPT1S-S,SH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SSRPT2S-S,SH

115

16.0

37.96

19.04

6

1/2

5465

24

700lbs/

5-20P

N/A

SARPT2S-S,SH

 

 

 

 

 

 

 

 

318kg

 

 

SMRPT2S-S,SH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pass-Thru Freezers - Hinged Doors - Standard Width

 

 

 

Storage

Shelf

No. Of

 

 

R-404A

Shipping

NEMA

Energy

Model

Voltage

Amps

Capacity

Capacity

H.P.

BTU/HR

Shelves

Charge Oz.

Weight

Plug

(KWH)

 

 

 

Ft3

Ft2

 

 

 

 

 

 

 

 

 

 

 

 

SSFPT1-S,SH

115

11.5

26.64

12.81

3

3/4

1923

12.5

672lbs/

5-15p

11.30

SAFPT1-S,SH

 

 

 

 

 

 

 

 

305kg

 

 

SMFPT1-S,SH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SSFPT2-S,SH

115/

10.0

55.42

27.54

6

1

4793

30

1001lbs/

N/A

14.26

SAFPT2-S,SH

208-230

 

 

 

 

 

 

 

454kg

 

 

SMFPT2-S,SH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SSFPT3-S,SH

115/

10.0

84.19

42.27

9

1-1/2

5185

64

1268lbs/

N/A

33.00

SAFPT3-S,SH

208-230

 

 

 

 

 

 

 

575kg

 

 

SMFPT3-S,SH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10

Specification Line

Specifications, continued

Fish Drawer Reach-In - Four Fish Drawers Per Section

 

 

 

Storage

Shelf

No. Of

 

 

R-404A

Shipping

NEMA

Energy

Model

Voltage

Amps

Capacity

Capacity

H.P.

BTU/HR

Shelves

Charge Oz.

Weight

Plug

(KWH)

 

 

 

Ft3

Ft2

 

 

 

 

 

 

 

 

 

 

 

 

SSRFF1

115

6.8

24.96

N/A

N/A

1/4

2092

12.5

418lbs/

5-15P

N/A

 

 

 

 

 

 

 

 

 

190kg

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SSRFF2

115

9.0

51.92

N/A

N/A

1/3

3226

19

650lbs/

5-15P

N/A

 

 

 

 

 

 

 

 

 

295kg

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Roll-In Refrigerators

 

 

 

Storage

Shelf

No. Of

 

 

R-404A

Shipping

NEMA

Energy

Model

Voltage

Amps

Capacity

Capacity

H.P.

BTU/HR

Shelves

Charge Oz.

Weight

Plug

(KWH)

 

 

 

Ft3

Ft2

 

 

 

 

 

 

 

 

 

 

 

 

SSRRI1-S

115

6.8

36.15

N/A

N/A

1/4

2092

12.5

476lbs/

5-15P

3.79

SARRI1-S

 

 

 

 

 

 

 

 

216kg

 

 

SMRRI1-S

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SSRRI1-G

115

7.8

36.15

N/A

N/A

1/3

2488

12.5

476lbs/

5-15P

5.46

SARRI1-G

 

 

 

 

 

 

 

 

216kg

 

 

SMRRI1-G

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SSRRI2-S

115

9.0

74.72

N/A

N/A

1/3

3226

24

768lbs/

5-15P

5.86

SARRI2-S

 

 

 

 

 

 

 

 

348kg

 

 

SMRRI2-S

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SSRRI2-G

115

16.0

74.72

N/A

N/A

1/2

5465

24

768lbs/

5-20P

9.28

SARRI2-G

 

 

 

 

 

 

 

 

348kg

 

 

SMRRI2-G

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SSRRI3-S

115

16.0

113.28

N/A

N/A

1/2

5465

24

1044lbs/

5-20p

7.56

SARRI3-S

 

 

 

 

 

 

 

 

4774kg

 

 

SMRRI3-S

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SSRRI3-G

115/

10.0

113.28

N/A

N/A

3/4

6920

48

1044lbs/

N/A

17.12

SARRI3-G

208-230

 

 

 

 

 

 

 

4774kg

 

 

SMRRI3-G

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

11

Delfield

Specifications, continued

Roll-In Freezers

 

 

 

Storage

Shelf

No. Of

 

 

R-404A

Shipping

NEMA

Energy

Model

Voltage

Amps

Capacity

Capacity

H.P.

BTU/HR

Shelves

Charge Oz.

Weight

Plug

(KWH)

 

 

 

Ft3

Ft2

 

 

 

 

 

 

 

 

 

 

 

 

SSFRI1-S

115

7.8

36.15

N/A

N/A

1/2

1516

12.5

497lbs/

5-15p

11.57

SAFRI1-S

 

 

 

 

 

 

 

 

225kg

 

 

SMFRI1-S

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SSFRI2-S

115/

10.0

74.12

N/A

N/A

1

4793

30

824lbs/

N/A

21.02

SAFRI2-S

208-230

 

 

 

 

 

 

 

374kg

 

 

SMFRI2-S

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SSFRI3-S

115/

11.8

113.28

N/A

N/A

1-1/2

5394

64

1128lbs/

N/A

25.70

SAFRI3-S

208-230

 

 

 

 

 

 

 

512kg

 

 

SMFRI3-S

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Hot Food Roll-Ins

Model

Voltage

Amps

Storage

Shelf

No. Of Shelves

Shipping

NEMA

Energy

Capacity Ft3

Capacity Ft2

Weight

Plug

(KWH)

 

 

 

 

SSHRI1-S,G

120/208-240

9.0

36.15

N/A

N/A

459lbs/

N/A

N/A

SAHRI1-S,G

 

 

 

 

 

208kg

 

 

SMHRI1-S,G

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SSHRI2-S, G

120/208-240

16.0

74.72

N/A

N/A

704lbs/

N/A

N/A

SAHRI2-S, G

 

 

 

 

 

319kg

 

 

SMHRI2-S, G

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SSHRI3-S, G

120/208-240

17.8

113.28

N/A

N/A

1008lbs/

N/A

N/A

 

 

 

 

 

 

457kg

 

 

 

 

 

 

 

 

 

 

 

Roll-Thru Refrigerators - Hinged Doors

 

 

 

Storage

Shelf

No. Of

 

BTU/

R-404A

Shipping

NEMA

Energy

Model

Voltage

Amps

Capacity

Capacity

H.P.

Charge

Shelves

HR

Weight

Plug

(KWH)

 

 

 

Ft3

Ft2

 

Oz.

 

 

 

 

 

 

 

 

 

SSRRT1-S

115

7.8

38.58

N/A

N/A

1/3

2488

12.5

514lbs/

5-15P

3.97

SARRT1-S

 

 

 

 

 

 

 

 

233kg

 

 

SMRRT1-S

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SSRRT2-S

115

16.0

79.74

N/A

N/A

1/2

5465

24

776lbs/

5-20P

6.77

SARRT2-S

 

 

 

 

 

 

 

 

352kg

 

 

SMRRT2-S

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SSRRT3-S

115/

11.3

120.90

N/A

N/A

3/4

7569

48

1116lbs/

N/A

8.01

SARRT3-S

208-230

 

 

 

 

 

 

 

506kg

 

 

SMRRT3-S

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Roll-Thru Hot Food Cabinets - Hinged Doors

Model

Voltage

Amps

Storage

Shelf Capacity

No. Of

Shipping

NEMA

Energy

Capacity Ft3

Ft2

Shelves

Weight

Plug

(KWH)

 

 

 

SSHRT1-S

120/208-240

9.0

38.58

N/A

N/A

519lbs/

N/A

N/A

SAHRT1-S

 

 

 

 

 

235kg

 

 

SMHRT1-S

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SSHRT2-S

120/208-240

16.0

79.74

N/A

N/A

836lbs/

N/A

N/A

SAHRT2-S

 

 

 

 

 

379kg

 

 

SMHRT2-S

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SSHRT3-S

120/208-240

17.8

120.90

N/A

N/A

985lbs/

N/A

N/A

SAHRT3-S

 

 

 

 

 

447kg

 

 

 

 

 

 

 

 

 

 

 

12

Loading...