Delfield SSHPT1-S, SSHPT2-S, SSHPT1-SH, SSHPT2-SH, SAHPT2-S General Manual

...
4 (1)
Delfield SSHPT1-S, SSHPT2-S, SSHPT1-SH, SSHPT2-SH, SAHPT2-S General Manual

Project __________________________________

®

DELFIELD

Item ____________________________________

 

Quantity ________________________________

Speciication Line®

CSI Section 11400

Date ____________________________________

 

Approved _______________________________

Self-Contained Solid Door Heated Pass-Thru

Models

One section

Two section

SSHPT1-S

SSHPT2-S

SSHPT1-SH

SSHPT2-SH

SAHPT1-S

SAHPT2-S

SAHPT1-SH

SAHPT2-SH

SMHPT1-S

SMHPT2-S

SMHPT1-SH

SMHPT2-SH

Stainless exterior and interior full door

Stainless exterior and interior half door

Stainless exterior and aluminum interior full door Stainless exterior and aluminum interior half door Stainless front aluminum exterior and interior full door Stainless front aluminum exterior and interior half door

Standard Features

 

• Stainless steel interior and exterior (SS)

 

• Stainless steel exterior, aluminum interior

 

(SA)

 

• Aluminum interior and exterior, stainless

 

front (SM)

 

• Built in door locks with heavy duty strikes

 

• Recessed metal door handle

 

• Exterior digital thermometer with high/low

 

temperature alarm

 

• Easy to use electronic control

 

• Easy access “lip up” shroud

 

• High density foamed in place

 

environmentally friendly, Kyoto Protocol

 

Compliant, Non ODP (Ozone Depletion

 

Potential), Non GWP (Global Warming

 

Potential) polyurethane keeps energy costs

 

low

 

• Three chrome plated wire shelves per section

SSHPT2-SH

• 6” adjustable stainless steel legs

• Stainless steel breaker strips

 

 

• Stainless steel interior door liner

 

• Two year parts & labor warranty

 

Options &

Accessories

Security (prison) package

6” polyurethane casters

Door ield rehingability

Additional shelves

Tray slides

Laminate on front, sides and back

Bottom mount electrical

Stainless steel banking strip

Heat shield end

Stainless steel kick plate

Laminate kick plate

4” stainless steel utility base

Specifications

Exterior: SS and SA models shall have corrosion resistant stainless steel exterior cabinet sides, front and shroud. SM models shall have corrosion resistant aluminum on exterior cabinet sides and will have stainless front and shroud. All units shall have the upper shroud hinged with a gas assist stay open feature to provide easy access to the refrigeration system.

Interior: Cabinet interior shall be corrosion resistant stainless steel (SS models) or heavy gauge aluminum (SA and SM models). Bottom and top surfaces shall be die stamped to provide radius corners and recessed loor. Three wire shelves are provided per section, standard shelves are chrome plated. Shelves rest on clips which are adjustable on 1” increments on stainless steel pilasters aixed to the cabinet interior. Pilasters are removable without tools for cleaning. Mounted to the interior ceiling, the interior incandescent light is controlled automatically through a switch mounted in the hinge assembly to protect against breakage. Door openings are protected with heavy gauge stainless steel breaker strips. An air duct shall be mounted to the ceiling assuring low velocity, even air movement throughout the cabinet interior.

Doors: Exterior shall be corrosion resistant stainless steel. Interior liner shall be stainless steel. Each door has two edge mount, self

closing, cam lift style hinges. Doors can be removed from the cabinet without the use of tools. Metal door handle shall be recessed into the door for easy grip without impacting aisle space. Keyed door lock is mounted in the door next to the handle. Lock engages into a heavy duty strike mounted to the cabinet face. Door gaskets are magnetic and mount to the door snapping in place and are removable without tools.

Heating system: Cabinets are designed to maintain temperatures between 120ºF and 200ºF. Heating elements are helical shaped, with tubular ins. High speed blower provides uniform airlow in the cabinet. Entire heating system is mounted to the exterior of the cabinet ceiling, outside the food zone. It is assembled as one piece and can be removed as one piece. Temperature is controlled by an adjustable electronic thermostat. System on/of switch is located on the front exterior of the cabinet.

Electrical: Standard electrical is 120/208-240 Volt, 60 Hz single phase. Connection must be hard wired to junction box on the exterior top of the cabinet.

980 S. Isabella Rd.

Phone: 800-733-8948 or 989-773-7981

 

Mt. Pleasant, Michigan 48858

www.delfield.com

Fax: 800-669-0619

 

 

 

 

 

<![if ! IE]>