Bongard BFP User Manual

5 (1)
Bongard BFP User Manual

Performances

20 adjustable levels (40 tray slides)Opticom control

Assembled freezing compressor (for an ambient temperature lower than 30°C)

BFP supplied assembled

Connecting power 230 V Single PH + Gr, 50 Hz

The advantages

Possibility to have assembled compressor, remote compressor, tropicalized assembled or disassembled compressor, silent compressor

Incorporated topside hermetic refrigeration unit

Refrigeration unit ready for use with refrigerating fluid R 404A

Easy to move thanks to its 3 wheels and 2 adjustable feet

Adjustable humidity (3090%)

The cabinets are fitted with “U-rails” for use either as a pastry or bakery unit

Easy cleaning

According to standards

BFP with tilting doors

Reach-In Retarder-proofer

Use

The BFP retarder-proofer is used to slow down and control proofing of dough pieces over a period of time defined by the user.

Operating principle

The dough pieces are stored in the retarder-proofer (between 2°C and 4°C) to retard proofing (72 hours maximum). Once the control panel has been programmed, the proofer manages the temperature increase on the basis of information previously entered by the user. Electronic regulation supervise stage-by-stage warming (and/or constant temperature increase degree- by-degree). The proofer stabilises the hot cycle temperature and offers at the end of the cycle a "sleeping" function, i.e. repeating the cold cycle if the controller is not activated after 45 minutes following the programmed end of proofing (adjustable values).

Construction

4 vertical mixed “U-rails” designed to receive the tray slides:BFP 1C5P : composed of 57 levels, with spacing of 21 mm

Cabinet : 60 mm isothermal hot electro-plated zinc panels, pre-lacquered, painted and coated with a protective food grade PVC of 120 micron thick

Panels are injected with polyurethane foam 40 kg/m35 tilting doors

Aluminium (frame and fins) and copper (tube) ceiling-fitted evaporatorWater connection Ø 12 mm, water drain Ø 32 mm

Models shipped disassembled, for on site assembly

   Remarks on refrigeration unit (compressor) :

Standard assembled: standard compressor on the top of the retarder-proofer.

Not assembled: standard compressor supplied separately from the retarder-proofer. The connection has to be done by a refrigerating engineer.

Remote compressor: specific high power compressor for a distance from 8 to 12 m to the retarder-proofer. The connection has to be done by a refrigerating engineer.

Tropicalized disassembled: compressor for a distance up to 4 m, specified for an ambiance below 40°C. The connection has to be done by a refrigerating engineer.

Tropicalized assembled: standard compressor on the top of the retarder-proofer, specified for an ambiance up to 40°C.

(*)Standard assembled: standard compressor on the top of the retarder-proofer.The retarder-proofer is delivered disassembled.

On request, one can have remote compressors or silent compressors

 

 

 

97

Bongard reserves the right to alter the characteristics of the models without prior notice - 12/2011

 

 

 

 

 

Loading...