American Power Conversion SRT2200XLA, SRT2200RMXLA, SRT3000XLA, SRT3000RMXLA, SRT2200RMXLA-NC Users Manual

...
5 (1)
Operation Manual
Smart-UPS™ On-Line SRT
Uninterruptible Power Supply
SRT2200XLA
SRT2200RMXLA
SRT3000XLA
SRT3000RMXLA SRT2200RMXLA-NC SRT3000RMXLA-NC
Tow er/Rack-Mount 2U

Product Description

The APC by Schneider Electric Smart-UPS™ On-Line SRT is a high performance uninterruptible power supply (UPS). The UPS helps to provide pro tec tion for electronic equipment from utility power blackouts , brownouts, sags, surges, small utility power fluctuations and large disturba nces. The UPS also provides bat tery backup power for connected equipment until utility power returns to acceptable levels or the ba tteries are completely dischar ged.
This user manual is available on the enclosed Documentation CD and on the APC by Schneider Electric web site, www.apc.com.

General Information

Important Safety Messages

Read the instructions carefull y to become familiar with the equipm ent before attempt ing to install, operate, service or maintain the UPS. The following special messages may appear throughout this manual or on the equipment to warn of potential hazards or to call attention to information that clarif ies or simplifies a procedure.
The addition of this symbol to a Danger or Warning product safety label indicates that an electrical hazard exists which will result in personal injury if the instructions are not followed.
The addition of this symbol to a Warning or Cauti on product safety label indicates that a hazard exists that can result in inj ury and product damage if the instructions are not followed.
WARNING
WARNING indicates a potentially hazardous situat ion which, if not avoided, can result in death or serious injury.
CAUTION
CAUTION indicates a potentially hazardous sit uation which, if not avoided, can re s u lt in minor or moderate injury.
NOTICE
NOTICE used to address practices not relate d to physical injury. The safety alert symbol is not used with this sign al wor d.
1Smart-UPS On-Line SRT2200XLA/SRT3000XLA Tow er/Rack-Mount 2U

Safety and General Information

• Adhere to all nati onal and local electric al codes.
• All wiring must be performed by a quali fied electrician.
• Changes and modifications to this unit not expressly approved by APC could void the warranty.
• This UPS is intended for indoor use only.
• Do not operate this UPS in dire ct sunlight, in cont act with fluids, or where there is excessive dus t or humidity.
• Be sure the air vents on the UPS are not bloc ked. Allow adequate space for proper ventilation .
• For a UPS with a factory installed power cord, connect the UPS power cable directly to a wall outlet. Do not use surge pro t ectors or ext en si on co r d s.
• The battery ty pical ly lasts for two to five years. En vironmenta l fa ctors imp act batte ry li fe. El evated ambie nt temperatures, poor quality utility power, and frequent short dura tion discharge s will shorten battery life.
• Replace the batte ry immediately when the UPS indicates battery re placement is necessary.
• The equipment is heavy. Alw ays practice safe lifting techniques ade quate for the weight of the equipment.
• The batterie s are heavy. Remov e the b atter ies b efore i nsta lli ng the UPS and e xterna l batt ery packs (XLB Ps), in a rack.
• Always install XLBPs at the bottom in rack-mount configurations. The UPS must be installed above the XLBPs.
• Always install peripheral equipment abov e the UPS in rack-mount configurations.
• Additional safety information can be found in the Safety Guide supplied with this unit.
Deenergizing safety
The UPS contains internal batteries and may present a shock hazard even when disconnected from the branch circuit (mains). Be fore installing or servi cing the equipment
• input circuit breaker is in the OFF position.
• inte rnal UPS the b at teries ar e re mo ved.
• XLBP battery modules are disconnected.
check that the:
Electrical safety
• For models with a hardwired input, the connection to the branch circuit (mains) must be perform ed by a qualif ied electr ician.
• Have a proper grounding for input s ocket for the models with pluggable power cords.
Battery safety
• Before installing or replacing the batte ries, remove jewelr y such as wr is twatches and rings. High short circuit current through conductive materials could ca us e severe burns.
• Do not dispose of batteries by burning them. The bat teries may explode.
• Do not open or mutilate batteries. Relea sed electrolyte is harmful to the skin and eyes, an d may be toxic.
Smart-UPS On-Line SRT2200XLA/SRT3000XLA Tow er/ R ack-Mount 2U2
General information
• The UPS will recognize as many as 10 external battery packs connected to the UPS.
Note: For each XLBP added, increased recharge time will be required.
• The model an d serial numbers are located on a small, rear panel label. For some models, an additional label is located on the chassis under the front bezel.
• Always re cycle used b atterie s.
• Recycle the package materials or save them for reuse.
FCC Class A radio frequency warning
This equipment has be en tes ted and found to comply with the l imits for a Cla ss A digit al devi ce, pur suant to part 15 of the FCC Rules. These limit s are inten ded to pr ovide re asonable protec tio n against ha rmful in te rferenc e when the equipment is operated in a commercial environ ment. This equipment generates, uses, and can radi ate radio frequency energy and, if not installed an d used in accordance with the instruction manual, may cause harmful interference to radio communication s. Operation of this equipment in a residential a r ea is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
3Smart-UPS On-Line SRT2200XLA/SRT3000XLA Tow er/Rack-Mount 2U

Product Overview

Specifications

For additional specifications refer to the APC by Schneider Electric web site, www.apc.com.
Environmental
Temperature
Operating Storage Operating
Elevation
Storage Humidity Protection Class
Note: Charge the battery modules every six months during storage.
Environmental factors impact battery life. Elevated ambient temperatures, high humidity, poor quality mains power , and frequent short duration discharges will shorten battery life.
0% to 95% relative humidity , non-condensing
IP 20 rating
0º to 40º C (32º to 104º F)
-15º to 45º C (5º to 113º F) 0 - 3,000 m (0 - 10,000 ft) 0 - 15,000 m (50,000 ft)
Physical
SRT2200XLA/SRT2200RMXLA/SRT2200RMXLA-NC model
The UPS is heavy. Follow all lif ting guidelin es.
Lifting guidelines 18 - 32 kg (40 - 70 lb) 32 - 55 kg (70 - 120 lb)
Unit weight batteries included, without packaging 26.5 kg (58.4 lb) Unit weight batteries included, with packaging Rack-Mount models: 34.6 kg (76.2 lb)
Tower models: 31.6 kg (69.7 lb)
Unit dimensions without packaging Height x Width x Depth
Unit dimensions with packaging Height x Width x Depth
The model and serial numbe rs a r e on a small label located on the rear pane l.
85 (2U) mm x 432 mm x 560 mm
3.35 (2U) in x 17 in x 22 in 245 mm x 600 mm x 810 mm
9.7 in x 23.6 in x 31.9 in
SRT3000XLA/SRT3000RMXLA/SRT3000RMXLA-NC model
The UPS is heavy. Follow all lif ting guidelin es.
Lifting guidelines 18 - 32 kg (40 - 70 lb) 32 - 55 kg (70 - 120 lb)
Unit weight batteries included, without packaging 32 kg (70.5 lb) Unit weight batteries included, with packaging Rack-Mount models : 41 kg (90.4 lb)
Tower models: 38 kg (83.8 lb)
Unit dimensions without packaging Height x Width x Depth
Unit dimensions with packaging Height x Width x Depth
The model and serial numbe rs a r e on a small label located on the rear pane l.
Smart-UPS On-Line SRT2200XLA/SRT3000XLA Tow er/ R ack-Mount 2U4
85 (2U) mm x 432 mm x 611 mm
3.35 (2U) in x 17 in x 24 in 245 mm x 600 mm x 870 mm
9.7 in x 23.6 in x 34.3 in
Battery
NOTICE
RISK OF EQUIPMENT DAMAGE
• Replace the battery at least every 5 years.
• Replace the battery immediately when the UPS indicates battery replacement is necessary.
Failure to follow these instructions can result in equipment damage
SRT2200 models S RT3000 models Battery type Replacem e nt ba tt ery module
This UPS has swappable battery modules. Refer to the appropriat e replacement battery us er m anual for installation instructions. Contact your dealer or go the APC by Schneider Electric web site,
www.apc.com for information on replacement batteries.
Number of battery modules 1 battery module Voltage for each battery mo dule 72 VDC 96 VDC Total battery voltage for the UPS 72 VDC 96 VDC Ah rating 5 Ah per battery module XLBP ca b l e length 500 mm (19.7 in)
Sealed, maintenance-free, Valve Regulated
Lead-Acid battery
APCRBC141 APCRBC152
5Smart-UPS On-Line SRT2200XLA/SRT3000XLA Tow er/Rack-Mount 2U
Electrical
Models Max. Rating
Onlin e Gree n Mode
Branch Circuit
Overcurrent Rating /
Building C ircuit Breaker
(CB) C u rrent Rating
SRT2200XLA 2200 VA / 1800 W 1800 VA 20 A SRT2200RMXLA/SRT2200RMXLA-NC SRT3000XLA 3000 VA / 2700 W 2700 VA 30 A SRT3000RMXLA/SRT3000RMXLA-NC
CAUTION
RISK OF FIRE, RISK OF DAMAGE TO EQUIPMENT OR PERSONNEL
Connect the UPS models onl y to a circuit provided with recommended maxi mu m branch circuit overcu rrent protection in accordance with the National Electrical Code, ANSI/NFPA 70 and the Canadian Electrical Code, Part I, C22.1.
Failure to fol low these instructions can result in fire, equipment damage and minor or moderate injury.
Output
Output Frequency 50 Hz / 60 Hz (Selectable) Nominal Output Voltage 120 V
Input
Input Frequency 40 Hz - 70 Hz Nominal Input Voltage 120 V Nominal Input Current SRT2200 models: 16 A
SRT3000 models: 24 A

Front Panel Features

Display interface panelUPS battery connectorsBattery moduleBezel
suo0860a
Smart-UPS On-Line SRT2200XLA/SRT3000XLA Tow er/ R ack-Mount 2U6

Rear Panel Features

Note: Refer to the table “Key to identify rear panel fe atures” on page 8, that provides a key to the callout numbers for the rear panel graphics depicted in this manual.
SRT2200XLA/SRT2200RMXLA
P
U
1
O
R
G
P
A
M
M
X
2
A
0
SRT2200RMXLA-NC
suo1092b
SRT3000XLA/SRT3000RMXLA
1
P
U
O
R
G
P
A
M
M
X
2
A
0
suo1093b
P
U
1
G
R
O
P
1
G
R
O
U
P
M
A
M
X
2
0
A
M
P
M
A
X
A
2
0
X A
3
M
P
P
U O
M
R
A
G
0 3
R
O
U
P
2
G
A
X
2
0
A
P
M
M
suo1094b
7Smart-UPS On-Line SRT2200XLA/SRT3000XLA Tow er/Rack-Mount 2U
SRT3000RMXLA-NC
Key to identify rear panel features
SmartSlot
AC input power cable
or hardwire input box
External battery
power and communication connector
The SmartSlot can be used to connect optional management accessories .
All models have factory installed inpu t power cables. Hardwired input box is an optional accessory.
Use the external battery cable on the XLBP to connect the UPS and XLBP. XLBPs provide extende d runtime during power out ages. The UPS will automatically recognize up to 10 external battery pack s.
U
P
1
G
R
O
P
1
R
O
G
U
M
P
A
M
X
2
0
A
M
P
M
A
X
A
2
0
X A
3
M
P U
P
O
M
R
A
G
0 3
R
O
U
P
2
G
A
X
2
0
A
P
M
M
suo1095b
Controllable
outlet group 1 Chassis ground screw
Controllable
outlet group 2 EPO terminal
Serial Com
USB port
Main outlet
Connect electronic devices to thes e outlets.
The UPS and XLBPs have groun d screws fo r connec ting the groun d leads. Prior t o connec ting a ground lead, disconnect the UPS from mains power.
Connect electronic devices to thes e outlets.
The Emergency Power Off (EPO) terminal allows the user to connect the UPS to a central EPO system.
The Serial Com port is used to communicate with the UPS.
Use only interface kits suppl ied or approved by APC by Schneider Electr ic. Any other serial interfa ce cable will be incompatible with the U PS connect o r.
The USB port is used to connect either a server for native operating system communications, or for software to communicate with the UPS. Note: Serial a nd USB c ommunic ation s hould not be u sed si multa neously. Use either t he Seri al Com or the USB port.
Connect electronic devices to the main outlet.
Smart-UPS On-Line SRT2200XLA/SRT3000XLA Tow er/ R ack-Mount 2U8
Loading...
+ 23 hidden pages