American Power Conversion UPS User Manual

0 (0)
American Power Conversion UPS User Manual

®

 

 

 

 

 

Back-UPS® ES 525

www.apc.com

 

 

 

 

 

 

User’s Manual

Inspection/Placement

 

 

Connect Equipment

Ensure the following items are inside the box:

 

 

Plug the Back-UPS ES power cord directly into a wall outlet; not a surge

1

User’s Manual

2protector or power strip.

 

 

 

USB Cable

Connect Universal Serial Bus (USB) Cable

Safety Manual

The supplied USB cable and software provide automatic file saving and shutdown of the

Warranty Registration Card

operating system in the case of a sustained power cut.

PowerChute® Personal Edition Software CD-ROM

Connect the USB cable to the Back-UPS ES Data Port. Connect the other end of the cable to

Notify the reseller if damage is found. Please fill out the

computer’s USB port. When installed the software will automatically find the USB Port of your

computer.

 

 

 

Warranty Registration Card, or fill out an on-line form at

 

 

 

www.apc.com/ru, to obtain warranty coverage.

If your computer has a serial port, instead of a USB port, you can request a serial cable from

Place the UPS as follows:

APC for use in connecting to the Back-UPS ES 525. Contact the office closest to you (see

APC Contact Information below). A serial cable will be sent to you at no charge.

Provide 5 cm clearance at the top and sides for

 

 

 

 

 

 

 

 

 

adequate airflow around the UPS.

 

 

Battery Back-up plus

Surge Protection

Avoid direct sunlight.

 

 

 

 

 

 

 

 

These outlets are powered whenever the Back-UPS ES is switched ON. During a power

Avoid excessive heat.

Avoid excessive humidity or liquids.

outage or other utility problems (low and high voltages), these outlets will be powered for a

Avoid excessive dust.

limited time by the Back-UPS ES. Plug your computer, monitor, and one other device into

these outlets.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0 - 40oC

3Operation and Software Installation

Press the ON/OFF switch to power the unit ON.

A single short beep and the green “Power On” indicator confirms that Back-UPS ES is on and ready to provide protection.

The Back-UPS ES should initially charge for at least 16 hours to ensure sufficient runtime. The unit is being charged whenever it is connected to utility power, whether the unit is turned ON or OFF.

Install PowerChute® Personal Edition Software

Place the PowerChute Personal Edition Software CDROM into your computer and follow the installation instructions on the screen.

Battery Replacement

The Back-UPS ES is shipped with battery connected. Typical battery life is 3 to 6 years. Battery replacement is a safe procedure isolated from electrical hazards. Do not replace the battery when the UPS is On Battery (amber indicator is lit).

NOTE: Small sparks may occur during battery connection. This is normal.

Turn the Back-UPS over. Press down on the two 1 release tabs. Slide the battery cover completely

off of the unit.

Release Tabs

Battery

Cover

Lift the battery out of the UPS. Note the wire 2 color at each terminal. Disconnect the two wires

from the battery terminals.

Caution: The plug on

 

 

 

the supply cord is the

 

 

 

disconnect

device

for

 

 

 

this product. The socket-

 

Battery Backup plus

Surge Protection

outlet that you plug into

 

 

 

shall be located near the

 

 

 

equipment and shall be

 

Surge Protection

 

easily

accessible.

The

 

 

 

socket-outlet

must

be a

Status

Back-UPS ES

grounding type.

 

 

see back

 

 

 

 

panel

 

 

Surge Protection

This outlet provides full-time protection from surges even if the Back-UPS ES is switched OFF. Plug your printer, fax machine, scanner, or other peripheral that does not need battery power into this outlet.

Connect FAX/Modem/Phone

Back-UPS ES protects a single line (2-wire) fax, modem or phone from surges when it is connected through the Back-UPS ES as shown.

Wall Outlet

Computer

 

 

USB Port

 

 

 

 

 

 

 

Circuit

 

 

 

Breaker

UPS Status

 

 

AC Line

Modem/Phone/Fax

 

Indicator

 

Cord

Status

 

 

 

see back

 

 

 

panel

 

 

 

Power

Status Indications

 

Switch

 

 

The Back-UPS ES indicates operating status using a combination of visual and audible indicators.

Status LED

Audible Indication

Status

Alarm Terminates When

 

 

 

 

Green

None

On Line - UPS is supplying conditioned AC

n/a

 

 

power to the connected equipment.

 

 

 

 

 

Amber

4 beeps every 30

On Battery - UPS is supplying battery

The UPS transfers back to On

 

seconds

power to the equipment connected to the

Line operation, or when the

 

 

Battery outlets.

UPS is turned off.

 

 

 

 

Amber

Rapid beeping

Low Battery Warning - UPS is supplying

The UPS transfers back to On

 

 

battery power to the equipment connected

Line operation, or when the

 

 

to the Battery outlets and the battery is near

UPS is turned off.

 

 

exhaustion.

 

 

 

 

 

Amber, flashing

None

Start-up Self-Test -UPS software is

The UPS is turned off with the

 

 

running a diagnostic test.

power switch or when the test is

 

 

 

completed.

 

 

 

 

Red

Beeps for 1 minute

Replace Battery - occurs when the battery

The UPS is turned off with the

 

every 5 hours.

fails self-test.

power switch or the battery is

 

 

 

replaced.

 

 

 

 

Red

Constant tone

Overloaded - Occurs when one or more of

The UPS is turned off with the

 

 

the battery powered outlets is overloaded.

power switch, or the equipment

 

 

 

connected to the overloaded

 

 

 

outlet(s) is disconnected.

 

 

 

 

Alternating Amber

None

Shutdown - Occurs when the UPS is

n/a

and Green

 

operating On Battery and has shutdown the

 

 

 

applications running on the connected

 

 

 

computer and has shutdown the computer.

 

 

 

 

 

Green and

Beeps every 2

Unit is online and battery is disconnected.

UPS power switch is turned

Amber, flashing

seconds.

 

OFF or when the battery is

 

 

 

connected.

 

 

 

 

See the Troubleshooting section for additional assistance.

Battery Terminal

Battery Wire

3

Connect the two wires to the replacement

 

 

battery and install the battery into the unit.

4

Slide the battery cover on the unit until it

locks in place.

990-1466 Copyright © 2003 American Power Conversion Corp. All rights reserved.