AEG EFC70700X, EFC90700X Manual

0 (0)

User manual

EFC 70700 - EFC 90700

Welcome to the world of Electrolux

Thank you for choosing a first class product from Electrolux, which hopefully will provide you with lots of pleasure in the future. The Electrolux ambition is to offer a wide variety of quality products that make your life more comfortable. You find some examples on the cover in this manual. Please take a few minutes to study this manual so that you can take advantage of the benefits of your new machine. We promise that it will provide a superior User Experience delivering Ease-of-Mind. Good luck!

electrolux 3

GB

4electrolux contents

Contents

GB

Safety warnings .................................

5

Description of the Appliance ..............

7

Control Panel.....................................

9

Maintenance and Care ...................

10

Special accessories .........................

14

Something Not Working ...................

14

Installation .......................................

15

The following symbols are used in this user manual:

Important information concerning your personal safety and information on how to avoid damaging the appliance.

General information and tips.

Environmental information.

Safety warnings

For the user

The cooker hood is designed to extract unpleasant odours from the kitchen, it will not extract steam.

Always cover lighted elements, to prevent excess heat from damaging the appliance. In the case of oil, gas and coal fired cookers it is essential to avoid open flames.

Also, when frying, keep the deep frying pan on the cooker top/cooker under careful control.

The hot oil in the frying pan might ignite due to overheating.

The risk of self-ignition increases when the oil being used is dirty.

It is extremely important to note that overheating can cause a fire.

Never carry out any flambé cooking under the hood.

Always disconnect the unit from the power supply before carrying out any work on the hood, including replacing the light bulb (take the cartridge fuse out of the fuse holder or switch off the automatic circuit breaker).

It is very important to clean the hood and replace the filter at the recommended intervals. Failure to do so could cause grease deposits to build up, resulting in a fire hazard.

The appliance is not intended for use by young children or infirm persons without supervision.

Older children must be supervised if using the appliance.

electrolux safety warnings 5

GB

Young children should be supervised to ensure that they do not play with the appliance.

WARNING - Ensure that the appliance is switched off before replacing the lamp to avoid the possibility of electric shock.

This appliance is marked according to the European directive 2002/96/EC on Waste Electrical and Electronic Equipment (WEEE).

By ensuring this product is disposed of correctly, you will help prevent potential negative consequences for the environment and human health, which could otherwise be caused by inappropriate waste handling of this product.

The symbol on the product, or on the documents accompanying the product, indicates that this appliance may not be treated as household waste. Instead it should be taken to the appropriate collection point for the recycling of electrical and electronic equipment.

Disposal must be carried out in accordance with local environmental regulations for waste disposal.

For more detailed information about treatment, recovery and recycling of this product, please contact your local council, your household waste disposal service or the shop where you purchased the product.

6electrolux safety warnings

For the installer

• When used as an extractor unit, the GB hood must be fitted with a hose

having preferably the same diameter as the outlet hole.

Attention: The hose is not supplied and must be purchased separately.

When installing the hood, make sure you observe the following minimum distance from the top edge of the cooking hob/ring surfaces:

electric cookers

600

mm

gas cookers

700

mm

If the instructions for installation for the gas hob specify a greater distance, this must be adhered to.

The national Standard on fuelburning systems specifies a maximum depression of 0.04 mbar in such rooms.

The air outlet must not be connected to chimney flues or combustion gas ducts. The air outlet must under no circumstances be connected to ventilation ducts for rooms in which fuel-burning appliances are installed.

The air outlet installation must comply with the regulations laid down by the relevant local authorities.

When the unit is used in extraction mode, a sufficiently large ventilation hole must be provided, with dimensions that are approximately the same as the outlet hole.

National and regional building regulations impose a number of restrictions on using hoods and fuelburning appliances connected to a chimney, such as coal or oil roomheaters and gas fires, in the same room.

Hoods can only be used safely with appliances connected to a chimney if the room and/or flat (air/environment combination) is ventilated from outside using a suitable ventilation hole approximately 500-600 cm2 large to avoid the possibility of a depression being created during operation of the hood.

If you have any doubts, contact the relevant controlling authority or building inspector’s office.

Since the rule for rooms with fuel burning appliances is “outlet hole of the same size as the ventilation hole”, a hole of 500-600 cm2, which is to say a larger hole, could reduce the performance of the extractor hood.

If the hood is used in its recirculation mode, it will operate simply and safely in the above conditions without the need for any of the aforementioned measures.

When the hood is used in its extraction mode, the following rules must be followed to obtain optimal operation:

-short and straight outlet hose

-keep bends in outlet hose to a minimum

-never install the hoses with an acute angle, they must always follow a gentle curve.

-keep the hose as large as possible (preferably the same diameter as the outlet hole).

-the length should be no more than: 3 metres with one 90° bend

2 metres with two 90° bends Bends of more than 90° will reduce the efficiency of the hood and reduce the airflow.

Failure to observe these basic instructions will drastically reduce the performance and increase the noise levels of the extractor hood.

AEG EFC70700X, EFC90700X Manual

electrolux description of the appliance

7

Description of the Appliance

The cooker hood is designed to extract unpleasant odours from the kitchen, it will not extract steam.

Extractor version

In this version fumes are extracted to the outside via a hose connected to the coupling ring.

Attention: The hose is not supplied and must be purchased separately.

In order to obtain the best performance the hose should have a diameter equal to the outlet hole. Should there already be a pipe of diameter 125 or 120 mm that ducts to the outside through the walls or roof, it is possible to use the 150/ 125-120 mm reduction flange provided. In this case the hood will be slightly noisier.

GB

To the outside

Coupling

ring

 

Hose Coupling

ring

Fig. 1 - Extractor version

Loading...