ABB component drives
ACS55, 0.25 to 3 hp / 0.18 to 2.2 kW
ABB component drives are designed
to be incorporated into a wide
variety of simple machines such as
automatic gates, conveyors, exercise
equipment, industrial ovens and
other applications in commercial
environments. The drives work with
single phase power supply and are
widely available and through the
ABB‘s distribution network
Drive parameters are easily set by
configuring the drive’s DIP switches
and potentiometers on the front panel.
For volume configuration, the optional
DriveConfig kit, which includes PC
software, can be used. DriveConfig
provides advanced drive configuration
options with different macros for default
I/O connections. DriveConfig can even
be used to configure unpowered drives.
Highlights
− Compact and slim
− Flexible installation
− Reduced motor noise with high
switching frequency
− Integrated 1
as standard
− Easy configuration via potentiometer
and switches
− Flexible and fast configuration of
powered and unpowered drives with
DriveConfig kit
st
environment EMC filter
Voltage and power range
− 1-phase, 110 to 120 V +10/-15%
(0.25 to 0.5 hp) 0.18 to 0.37 kW
− 1-phase, 200 to 240 V +10/-15%
(0.25 to 3 hp) 0.18 to 2.2 kW
Applications
− Fans and pumps
− Exercise equipment
− Gate control
− Material handling
− Conveyors
Options
− Input/Output chokes
− Potentiometer
− DriveConfig kit
Technical data and types
Ratings Output current Input Type code Frame
P
hp kW A A A mm mm mm mm kg
Built-in EMC filter, 1-phase supply voltage 200/240 V, +10/-15%, 3-phase output 200/240 V
0.25 0.18 1.4 2.1 4.4 ACS55-01E-01A4-2 A 170 146.5 45 128 0.65
0.5 0.37 2.2 3.3 6.9 ACS55-01E-02A2-2 A 170 146.5 45 128 0.7
1.0 0.75 4.3 6.5 10.8 ACS55-01E-04A3-2 B 170 146.5 67.5 128 0.95
2 1.5 7.6 11.4 18.2 ACS55-01E-07A6-2 D 226 203 70 159 1.1
3 2.2 9.8 14.7 22 ACS55-01E-09A8-2 D 226 203 70 159 1.1
No EMC filter, 1-phase supply voltage 200/240 V, +10/-15%, 3-phase output 200/240 V
0.25 0.18 1.4 2.1 4.4 ACS55-01N-01A4-2 A 170 146.5 45 128 0.65
0.5 0.37 2.2 3.3 6.9 ACS55-01N-02A2-2 A 170 146.5 45 128 0.7
1.0 0.75 4.3 6.5 10.8 ACS55-01N-04A3-2 B 170 146.5 67.5 128 0.95
2 1.5 7.6 11.4 18.2 ACS55-01N-07A6-2 C 194 171 70 159 1.1
3 2.2 9.8 14.7 22 ACS55-01N-09A8-2 C 194 171 70 159 1.1
Built-in EMC filter, 1-phase supply voltage 110/120 V, +10/-15%, 3-phase output 200/240 V
0.25 0.18 1.4 2.1 6.4 ACS55-01E-01A4-1 A 170 146.5 45 128 0.65
0.5 0.37 2.2 3.3 9.5 ACS55-01E-02A2-1 A 170 146.5 45 128 0.7
No EMC filter, 1-phase supply voltage 110/120 V, +10/-15%, 3-phase output 200/240 V
0.25 0.18 1.4 2.1 6.4 ACS55-01N-01A4-1 A 170 146.5 45 128 0.55
0.5 0.37 2.2 3.3 9.5 ACS55-01N-02A2-1 A 170 146.5 45 128 0.6
H1 = Height with mounting clip
H2 = Height without mounting clip
W = Width
D = Depth
ABB standard macro I/O configuration (default)
nominal max current size H1 H2 W D Weight
NPN
ACS55
COM
COM
SPEED/AI
+10 V
jog reverse start/
H1
H2
stop
+12 V
START
REV
JOG
SCR
1011RO1
RO2
Supply terminals L, N (R, S)
Configuration switches
Control potentiometers
DriveConfig kit interface
Relay output terminals
Analogue input signal selector (U/I)
Control terminal
Motor terminals T1, T2, T3 (U, V, W)
fault or run
Motor connection
Voltage
3-phase, from 0 to U
(for 110/120 V from 0 to 230 V)
Frequency
Overload capacity
0 to 120/130 Hz
150% (60 s)
Control connections
One analog input
Voltage signal
Current signal
Potentiometer reference value
Response time
Resolution
Accuracy
Three digital inputs
0 (2) to 10 V, 200 kΩ single-ended
0 (4) to 20 mA, 100 Ω single-ended
10 V ±2% max. 10 mA, 1 kΩ ≤ R ≤ 10 kΩ
≤ 60 ms
0.1%
±1%
12 V DC with internal or 12 to 24 V DC
external supply, PNP
Input impedance
Response time
1.5 Ω
≤ 9 ms
One relay output
Switching voltage
Maximum continuous current
12 to 250 V AC or max 30 V DC
2 A
Application parameters
As standard With DriveConfig kit
Motor nominal frequency
Acceleration time
Deceleration time
Maximum frequency
Relay output
Load type
50/60 Hz 40 to 250 Hz
0.1 to 30 s 0.1 to 100 s
0.1 to 30 s 0.1 to 100 s
50 to 120 Hz 0 to 250 Hz
Fault/Run Fault/Fault (-1)/Run
Pump/fan or constant
Switching frequency
Standard
5 kHz, adjustable up to 16 kHz with
automatic switching frequency reduction
Features available with
DriveConfig kit
Application macro selection, IR
compensation, constant speed selection,
stop mode selection, reset mode
selection
Product compliance
CE, UL, cUL, C-Tick and GOST R approvals
Environmental limits
Degree of protection
IP20
Ambient temperature
-20 to 40 °C
with nominal current and 5 kHz switching
frequency, no frost allowed
up to 50 °C
Relative humidaity
with derating
lower than 95% (without condensation)
SUPPLY
3AUA0000073307 REV D US 17.12.2009
D
W
For more information see catalog ABB component drives,
ACS55-PHTC01U-EN (3AUA0000073307).
For more information please contact:
www.abb.us/drives
© Copyright 2009 ABB. All rights reserved. Specifications subject to change
without notice.