Hitachi RAS-80YHA User Manual

4 (1)

SPLIT TYPE

INDOOR UNIT/OUTDOOR UNIT

MODEL

RAS-80YHA/RAC-80YHA

INDOOR UNIT

OUTDOOR UNIT

RAS-80YHA

RAC-80YHA

Instruction manual Page 1~22 To obtain the best performance and ensure years of trouble free use, please read this instruction manual completely.

– 1 –

SAFETY PRECAUTION

Please read the “Safety Precaution” carefully before operating the unit to ensure correct usage of the unit.

Pay special attention to signs of “Warning” and “ Caution”. The “Warning” section contains matters which, if not observed strictly, may cause death or serious injury. The “Caution” section contains matters which may result in serious consequences if not observed properly. Please observe all instructions strictly to ensure safety.

The sign indicate the following meanings.

 

Make sure to connect earth line.

The sign in the figure indicates prohibition.

 

Indicates the instructions that must be followed.

 

Please keep this manual after reading.

 

 

 

 

PRECAUTIONS DURING INSTALLATION

 

 

 

Do not reconstruct the unit.

 

 

 

 

Water leakage, fault, short circuit or fire may occur if you reconstruct

 

 

 

the unit by yourself.

 

 

 

 

Please ask your sales agent or qualified technician for the installation

 

 

 

of your unit. Water leakage, short circuit or fire may occur if you install

WARNING

the unit by yourself.

 

 

 

 

Please use earth line.

 

 

 

 

Do not place the earth line near water or gas pipes, lightning-conductor,

 

 

 

or the earth line of telephone. Improper installation of earth line may

 

 

 

cause electric shock.

 

 

 

 

A circuit breaker should be installed depending on the mounting site of

 

 

 

the unit. Without a circuit breaker, the danger of electric shock exists.

CAUTION

 

Do not install near location where there is flammable gas. The outdoor

 

unit may catch fire if flammable gas leaks around it.

 

 

 

Please ensure smooth flow of water when installing the drain hose.

 

 

 

PRECAUTIONS DURING SHIFTING OR MAINTENANCE

 

Should abnormal situation arises (like burning smell), please stop operating the unit

 

 

and turn off the circuit breaker. Contact your agent. Fault, short circuit or fire may

W

 

occur if you continue to operate the unit under abnormal situation.

A

 

Please contact your agent for maintenance. Improper self maintenance may cause

R

 

electric shock and fire.

 

N

 

 

I

 

Please contact your agent if you need to remove and reinstall the unit. Electric

N

 

 

 

 

G

 

shock or fire may occur if you remove and reinstall the unit yourself improperly.

 

 

 

PRECAUTIONS DURING OPERATION

 

Avoid an extended period of direct air flow for your health.

W

 

 

Do not insert a finger, a rod or other objects into the air outlet or inlet. As the fan

 

 

is rotating at a high speed, it will cause injury. Before cleaning, be sure to stop the

A

 

 

 

 

operation and turn the breaker OFF.

R

 

 

 

 

N

Do not use any conductor as fuse wire, this could cause fatal accident.

I

 

 

 

 

N

 

 

During thunder storm, disconnect and turn off the circuit breaker.

G

 

 

 

 

 

 

 

This unit has UV LED which emits ultra violet light.

 

 

AVOID DIRECT EYE EXPOSURE.

 

 

 

 

– 2 –

 

Hitachi RAS-80YHA User Manual

PRECAUTIONS DURING OPERATION

The product shall be operated under the manufacturer specification and not for any other intended use.

Do not attempt to operate the unit with wet hands, this could cause fatal accident.

When operating the unit with burning equipments, regularly ventilate the room to avoid oxygen insufficiency.

Do not direct the cool air coming out from the air-conditioner panel to face household heating apparatus as this may affect the working of apparatus such as the electric kettle, oven etc.

Please ensure that outdoor mounting frame is always stable, firm and without defect. If not, the outdoor unit may collapse and cause danger.

 

Do not splash or direct water to the body of the unit when cleaning it as this

 

may cause short circuit.

 

Do not use any aerosol or hair sprays near the indoor unit. This chemical

 

can adhere on heat exchanger fin and blocked the evaporation water flow

 

to drain pan. The water will drop on tangential fan and cause water splashing

C

out from indoor unit.

A

 

U

Please switch off the unit and turn off the circuit breaker during cleaning, the

T

high-speed fan inside the unit may cause danger.

I

 

O

 

N

 

Turn off the circuit breaker if the unit is not to be operated for a long period.

Do not climb on the outdoor unit or put objects on it.

Do not put water container (like vase) on the indoor unit to avoid water dripping into the unit. Dripping water will damage the insulator inside the unit and causes short-circuit.

Do not place plants directly under the air flow as it is bad for the plants.

When operating the unit with the door and windows opened, (the room humidity is always above 80%) and with the air deflector facing down or moving automatically for a long period of time, water will condense on the air deflector and drips down occasionally. This will wet your furniture. Therefore, do not operate under such condition for a long time.

If the amount of heat in the room is above the cooling or heating capability of the unit (for example: more people entering the room, using heating equipments and etc.), the preset room temperature cannot be achieved.

This appliance is not intended for use by young children or infirm persons unless they have been adequately supervised by a responsible person to ensure that they can use the appliance safely.

Young children should be supervised to ensure that they do not play with the appliance.

3 –

NAMES AND FUNCTIONS OF EACH PART

INDOOR UNIT

AIR FILTER

To prevent dust from coming into the indoor unit.

(Refer page 21)

FRONT PANEL (AIR INLET).

INDOOR UNIT INDICATORS

Light indicator showing the operating condition.

(Refer page 5)

HORIZONTAL DEFLECTOR

VERTICAL DEFLECTOR (AIR OUTLET)

(Refer page 16)

REMOTE CONTROLLER

Send out operation signal to the indoor unit. So as to operate the whole unit. (Refer page 6)

OUTDOOR UNIT

AIR INLET (BACK, LEFT SIDE)

AIR OUTLET

Blow out warm air.

MODEL NAME AND DIMENSIONS

MODEL

WIDTH (mm)

HEIGHT (mm)

DEPTH (mm)

 

 

 

 

RAS-80YHA

1150

333

245

 

 

 

 

RAC-80YHA

925

875

315

 

 

 

 

– 4 –

OPERATION INDICATOR

TEMPORARY SWITCH

Temporary Switch

Press

Non-conductor Stick

Use this switch to start and stop when the remote controller does not work. [Use non-conductor stick (example toothpick)]

By pressing the temporary switch, the operation is done in previously set operation mode.

When the operation is done using the temporary switch after the power source is turned off and turn on again, the operation is done in automatic mode.

INDOOR UNIT INDICATORS

TIMER LAMP

This lamp lights when the timer is working.

OPERATION LAMP

This lamp lights during operation.

The OPERATION LAMP flashes in the following cases during heating.

(1)During preheating

For about 2–3 minutes after starting up.

(2)During defrosting

Defrosting will be performed about once an hour when frost forms on the heat exchanger of the outdoor unit, for 5–10 minutes each time.

FILTER LAMP

When the device is operated for a total of about 200 hours, the FILTER lamp lights to indicate that it is time to clean the filter. The lamp goes out when the “ (AUTO SWING)” button is pressed while the device is on “STANDBY MODE”.

– 5 –

NAMES AND FUNCTIONS OF EACH PART

REMOTE CONTROLLER

This controls the operation of the indoor unit. The range of control is about 7 meters. If indoor lighting is controlled electronically, the range of control may be shorter.

This unit can be fixed on a wall using the fixture provided. Before fixing it, make sure the indoor unit can be controlled from the remote controller.

Signal emitting window/transmission sign

Point this window toward the indoor unit when controlling it. The transmission sign blinks when a signal is sent.

Display

This indicates the room temperature selected, current time, timer status, function and intensity of circulation selected.

START/STOP button

Press this button to start operation. Press it again to stop operation.

FAN SPEED selector

This determines the fan speed. Every time you press this button, the intensity of circulation will change from (AUTO) to (HI) to (MED) to (LOW) (during the (FAN) mode, from HI to MED to LOW).

AUTO SWING button

Controls the angle of the horizontal air deflector.

TEMPERATURE buttons

Use these buttons to raise or lower the temperature setting. (Keep pressed, and the value will change more quickly.)

SLEEP button

Use this button to set the sleep timer.

TIME button

Use this button to set and check the time and date.

RESET buttons

FUNCTION selector

Use this button to select the operating mode. Every time you press it, the mode will change from (AUTO) to (HEAT) to (DEHUMIDIFY) to (COOL) and to (FAN) cyclically.

PARALLEL SWING button

Controls the angle of the vertical air deflectors to parallel.

SYMMETRY SWING button

Controls the angle of the vertical air deflectors to symmetry.

TIMER control

Use this button to set the timer.

OFF-TIMER button Select the turn OFF time.

ON-TIMER button Select the turn ON time.

RESERVE button Time setting reservation.

CANCEL button Cancel time reservation.

Precautions for Use

Do not put the remote controller in the following places. In direct sunlight.

In the vicinity of a heater.

Handle the remote controller carefully. Do not drop it on the floor, and protect it from water.

Once the outdoor unit stops, it will not restart for about 3 minutes (unless you turn the power switch off and on or unplug the power cord and plug it in again).

This is to protect the device and does not indicate a failure.

If you press the FUNCTION selector button during operation, the device may stop for about 3 minutes for protection.

– 6 –

VARIOUS FUNCTIONS

Auto Restart Control

If there is a power failure, operation will be automatically restarted when the power is resumed with previous operation mode and airflow direction.

(As the operation is not stopped by remote controller.)

If you intend not to continue the operation when the power is resumed, switch off the power supply.

When you switch on the circuit breaker, the operation will be automatically restarted with previous operation mode and airflow direction.

Note: 1. If you do not require Auto Restart Control, please consult your sales agent or OFF by remote control.

2.Auto Restart Control is not available when Timer or Sleep Timer mode is set.

AUTOMATIC OPERATION

The device will automatically determine the mode of operation, HEAT, COOL or DEHUMIDIFY depending on the current room temperature. The selected mode of operation will change when the room temperature varies.

RESET

Press the FUNCTION selector so that the display indicates the (AUTO) mode of operation.

When AUTO has been selected, the device will automatically determine the mode of operation, HEAT, COOL or DEHUMIDIFY depending on the current room temperature.

1● If the mode automatically selected by the unit is not satisfactory, manually change the mode setting (heat, dehumidify, cool or fan).

START

Press the (START/STOP) button.

Operation starts with a beep.

STOP

Press the button again to stop operation.

As the settings are stored in memory in the remote controller, you only have to press the (START/STOP) button next time.

You can raise or lower the temperature setting as necessary by maximum of 3°C.

°C

Press the temperature button and the temperature setting will change by

1°C each time.

 

The preset temperature and the actual room temperature may vary somewhat depending on conditions.

The display does not indicate the preset temperature in the AUTO mode. If you change the setting, the indoor unit will produce a beep.

Press the (FAN SPEED) button, AUTO and LOW is available.

Condition of Automatic Operation

Initial room temperature

 

 

Function

Temperature setting

FAN SPEED

(approx.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HI at start, MED or LOW

 

-

 

 

Over 27°C

COOL

27°C

after the preset temperature

 

 

 

 

 

is reached

 

 

 

 

 

 

 

 

 

Slightly lower than the

 

23~27°C

-

DEHUMIDIFY

LOW

room temperature

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HI at start, MED or LOW

Under 23°C

-

HEAT

23°C

after the preset temperature

 

 

 

 

 

is reached

 

 

 

 

 

– 7 –

HEATING OPERATION

Use the device for heating when the outdoor temperature is under 21°C.

When it is too warm (over 21°C), the heating function may not work in order to protect the device.

1

Press the FUNCTION selector so that the display indicates

(HEAT).

 

 

 

Set the desired FAN SPEED with the

(FAN SPEED) button

 

(the display indicates the setting).

 

 

(AUTO): The fan speed is HI

at first and varies to

2

 

MED or LOW automatically when the preset

 

temperature has been reached.

 

 

 

(HI)

: Economical as the room will become warm

 

 

quickly.

 

 

 

But you may feel a chill at the beginning.

 

(MED)

: Quiet.

 

 

(LOW)

: More quiet.

 

3

START

STOP

Set the desired room temperature with the TEMPERATURE buttons (the display indicates the setting).

The range of 18-22°C is recommended as the room temperature for heating.

If the temperature setting is 20°C, the room temperature will be controlled at around 20°C.

The temperature setting and the actual room temperature may vary somewhat depending on conditions.

Press the (START/STOP) button. Heating operation starts with a beep. Press the button again to stop operation.

As the settings are stored in memory in the remote controller, you only have to press the (START/STOP) button next time.

– 8 –

Loading...
+ 18 hidden pages