Whirlpool WGD5500S, WGD5520S, WGD5530S, WGD5550S, WGD5540S User Manual

...
0 (0)
Whirlpool WGD5500S, WGD5520S, WGD5530S, WGD5550S, WGD5540S User Manual

®

Gas Dryer

PRODUCT MODEL NUMBERS

PRODUCT DIMENSIONS

 

 

 

LGR8620P

WGD5530S

WGD5800V

 

 

 

 

 

LGR8648P

WGD5540S

WGD5810S

 

 

 

 

 

WGD5100S

WGD5550S

WGD5820S

 

 

15¹⁄ "

 

22³⁄ "

WGD5200T

WGD5600S

WGD5830S

A. Small Opening

43³⁄ "

(38.74cm)

43³⁄ "

(57.8cm)

 

WGD5300S

WGD5700S

WGD5840S

(110cm)

(110cm)

 

Side-Swing Door

 

 

 

 

WGD5500S

WGD5790S

WGD5850S

B. Large Opening

 

 

 

 

WGD5520S

WGD5800S

WGD5900S

 

 

 

 

Side-Swing Door

 

 

 

 

 

 

 

 

 

 

 

Gas supply:

 

 

 

*26"

*27³⁄ "

 

 

 

 

(66cm)

 

(70.5cm)

 

1/2" IPS pipe is recommended.

 

 

29"

 

29"

 

 

 

(73.66cm)

 

(73.66cm)

 

3/8" approved tubing is acceptable for lengths

 

A

 

B

 

under 20 ft (6.1 m) if local codes and gas supplier

 

 

 

 

 

permit.

 

 

 

 

 

 

 

Must include 1/8" NPT minimum plugged tapping

 

 

22³⁄ "

 

 

accessible for test gauge connection, immediately

C. Wide Opening

 

 

 

43 ³⁄ "

(57.8cm)

43³⁄ "

 

upstream of the gas connection to the dryer.

 

Side-Swing Door

(110cm)

 

(110cm)

 

Must include a shutoff valve:

 

D. Wide Opening

 

 

 

13³⁄ "

 

 

 

 

 

 

An individual manual shutoff valve must be

Hamper Door

 

 

 

(34.9cm)

 

 

 

 

installed within six (6) feet (1.8 m) of the dryer in

 

*27³⁄ "

 

*27³⁄ "

 

accordance with the National Fuel Gas Code, ANSI

 

 

 

Z223.1. The location should be easy to reach for

 

(70.5cm)

 

(70.5cm)

 

 

29"

 

29"

 

opening and closing.

 

 

 

 

 

 

(73.66cm)

 

(73.66cm)

 

The gas pipe that comes out through the rear of

 

C

 

D

 

your dryer has a 3/8" male pipe thread.

 

 

 

 

 

 

 

 

Electrical: 120-Volt, 60-Hz., AC-only, 15or

 

*Most installations require a minimum 5-1/2" (14 cm) clearance

20-amp fused electrical supply is required. (Time-

 

behind the dryer for the exhaust vent with elbow.

 

delay fuse or circuit breaker is recommended.) It is

RECESSED AREA AND CLOSET INSTALLATION

 

 

recommended that a separate circuit serving only

 

 

this dryer be provided.

 

 

 

 

 

 

Exhaust venting: Exhaust your dryer to the

For closet installation

 

 

3"

outside. Four-inch diameter vent is required. Rigid

with a door, minimum

14" max.

 

(7.6 cm)

or flexible metal exhaust vent must be used. Do Not

ventilation openings in

(35.6cm)

48 in. 2

 

use plastic or metal foil vent. Exhaust outlet hood

the top and bottom of

18"

2

 

must be at least 12" (30.5 cm) from the ground or

(310 cm )

 

the door are required.

(45.7 cm)

 

 

any object that may be in the path of the exhaust.

 

 

Louvered doors with

 

 

 

 

 

 

 

 

equivalent air openings

 

 

 

 

are acceptable.

 

24 in.2

3"

 

 

 

(155 cm2 )

 

 

 

 

(7.6 cm)

1"

 

 

 

29"

 

 

 

 

 

 

 

 

¹⁄

 

 

 

 

 

 

 

1"

 

 

1"

27³⁄ "

 

 

 

(2.5 cm)

 

(73.66 cm)

(2.5 cm)(2.5 cm)(70.5 cm) (14 cm)

 

 

 

 

A

 

 

 

 

 

 

 

B

 

 

 

C

 

EXHAUST VENTING

 

 

 

A. Recessed area

 

 

 

 

 

 

 

 

 

 

 

 

 

B. Side view - closet or confined area

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C. Closet door with vents

 

 

 

 

 

 

 

 

 

 

 

4"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(10.2 cm)

1. Select the route that will provide the straightest and most direct path outdoors. Plan

 

 

 

 

 

 

 

 

 

Box hood style

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4"

 

 

 

 

 

the installation to use the fewest number of elbows and turns. When using elbows or

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(10.2 cm)

 

2.5"

making turns, allow as much room as possible. Bend vent gradually to avoid kinking.

 

 

 

 

 

 

 

 

 

 

 

 

(6.4 cm)

 

 

 

 

 

 

 

 

 

 

 

 

 

Avoid 90° turns.

 

 

 

4"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(10.2 cm)

 

Angled style

 

 

Louvered style

 

2. Determine vent length.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Vent Length Chart

 

 

 

The maximum length of the exhaust system depends upon:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Number of

 

 

Type of

Box or

Angled

 

 

 

 

• The type of vent (rigid metal or flexible metal).

 

 

90° turns

 

 

vent

Louvered

hoods

 

 

or elbows

 

 

 

 

 

 

 

hoods

 

 

• The number of elbows used.

 

 

 

 

 

 

 

 

 

 

 

 

 

0

Rigid metal

64 ft (20 m)

58 ft (17.7 m)

• Type of hood.

 

 

 

Flexible metal

36 ft (11 m)

28 ft (8.5 m)

 

 

 

See the exhaust vent length chart that matches your hood type for the maximum vent

 

 

 

 

 

 

 

 

 

 

 

 

 

1

Rigid metal

54 ft (16.5 m)

48 ft (14.6 m)

lengths you can use.

 

 

 

Flexible metal

31 ft (9.4 m)

23 ft (7 m)

 

 

 

 

 

 

3. Determine the number of elbows you will need.

2

Rigid metal

44 ft (13.4 m)

38 ft (11.6 m)

 

 

 

Flexible metal

27 ft (8.2 m)

19 ft (5.8 m)

NOTE: Do not use vent runs longer than specified in the Vent Length Chart.

 

 

 

 

 

 

 

 

 

 

 

 

 

3

Rigid metal

35 ft (10.7 m)

29 ft (8.8 m)

The chart at left helps you determine your maximum vent length based on the number

 

 

 

Flexible metal

25 ft (7.6 m)

17 ft (5.2 m)

 

 

 

 

 

 

 

 

 

 

 

 

 

of 90° turns or elbows you will need and the type of vent (rigid or flexible metal) and

4

Rigid metal

27 ft (8.2 m)

21 ft (6.4 m)

hood that you will use.

 

 

 

Flexible metal

23 ft (7 m)

15 ft (4.6 m)

Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.

Dimensions are for planning purposes only. For complete details, see Installation

Ref. 8562582 Rev B

Instructions packed with product. Specifications subject to change without notice.

09-23-08