Whirlpool GXU7130DXB0, GXU7130DXB1, GXU7130DXQ0, GXU7130DXQ1, GXU7130DXS0 Owner’s Manual

...
0 (0)

30" (76.2 CM) RANGE HOOD

Installation Instructions and Use & Care Guide

HOTTE D’ASPIRATION DE 30" (76,2 CM)

Instructions d’installation et Guide d’utilisation et d’entretien

Table of Contents/Table des matières..................................................................

2

IMPORTANT: READ AND SAVE THESE INSTRUCTIONS.

FOR RESIDENTIAL USE ONLY.

IMPORTANT : LIRE ET CONSERVER CES INSTRUCTIONS.

POUR UTILISATION RÉSIDENTIELLE UNIQUEMENT.

LI3Y5B/W10320576B

TABLE OF CONTENTS

 

RANGE HOOD SAFETY............................................................

3

INSTALLATION REQUIREMENTS ..........................................

4

Tools and Parts ....................................................................

4

Location Requirements ........................................................

4

Venting Requirements ..........................................................

5

Electrical Requirements .......................................................

7

INSTALLATION INSTRUCTIONS ...........................................

7

Prepare Location ..................................................................

7

Install Range Hood................................................................

9

Make Electrical Connection ................................................

10

Complete Installation .........................................................

10

RANGE HOOD USE ..............................................................

11

Range Hood Controls ........................................................

11

RANGE HOOD CARE ...........................................................

11

Cleaning .............................................................................

11

WIRING DIAGRAM ...............................................................

12

ASSISTANCE OR SERVICE ..................................................

13

In the U.S.A. .......................................................................

13

In Canada ...........................................................................

13

Accessories ........................................................................

13

WARRANTY ..........................................................................

14

TABLE OF CONTENTS

 

SÉCURITÉ DE LA HOTTE DE CUISINIÈRE .........................

15

EXIGENCES D'INSTALLATION .............................................

17

Outils et pièces ..................................................................

17

Exigences d'emplacement .................................................

17

Exigences concernant l'évacuation ...................................

18

Spécifications électriques ..................................................

20

INSTRUCTIONS D'INSTALLATION ......................................

20

Préparation de l'emplacement ...........................................

20

Installation de la hotte.........................................................

22

Raccordement électrique ....................................................

24

Achever l’installation ..........................................................

24

UTILISATION DE LA HOTTE ................................................

25

Commandes de la hotte de cuisinière ...............................

25

ENTRETIEN DE LA HOTTE ..................................................

25

Nettoyage ...........................................................................

25

SCHÉMA DE CÂBLAGE .......................................................

26

ASSISTANCE OU SERVICE .................................................

27

Accessoires ........................................................................

27

GARANTIE .............................................................................

27

2

Whirlpool GXU7130DXB0, GXU7130DXB1, GXU7130DXQ0, GXU7130DXQ1, GXU7130DXS0 Owner’s Manual

RANGE HOOD SAFETY

Your safety and the safety of others are very important.

many important safety messages in this manual and on your appliance. Always read and obey all safety

safety alert symbol.

alerts you to potential hazards that can kill or hurt you and others.

messages will follow the safety alert symbol and either the word “DANGER” or “WARNING.” mean:

DANGER WARNING

You can be killed or seriously injured if you don't immediately follow instructions.

You can be killed or seriously injured if you don't follow instructions.

All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can happen if the instructions are not followed.

State of California Proposition 65 Warnings:

WARNING: This product contains one or more chemicals known to the State of California to cause cancer.

WARNING: This product contains one or more chemicals known to the State of California to cause birth defects or other reproductive harm.

IMPORTANT SAFETY INSTRUCTIONS

READ AND SAVE THESE INSTRUCTIONS

3

INSTALLATION REQUIREMENTS

Tools and Parts

Gather the required tools and parts before starting installation. Read and follow the instructions provided with any tools listed here.

Tools needed

Drill

1¼" (3.0 cm) drill bit

18" (3.0 mm) drill bit for pilot holes

Pencil

Wire stripper or utility knife

Tape measure or ruler

Caulking gun and weatherproof caulking compound

Flat-blade screwdriver

Phillips screwdriver

Saber or keyhole saw

Vent clamps

Metal snips

Compass or 8" (20.3 cm) circle template

Parts supplied

Remove parts from package. Check that all parts are included.

2 - Metal filters

6 - 3.5 x 9.5 mm mounting screws

3 - 4.5 x 13 mm damper screws

3¼" x 10" (8.3 x 25.4 cm) damper/vent connector

T-20 Torx®† adapter

Parts needed

3¼" x 10" (8.3 x 25.4 cm) or 6" (15.2 cm) or larger round metal venting

6" (15.2 cm) or larger round damper, if using 6" (15.2 cm) or larger round vent system

3¼" x 10" (8.3 x 25.4 cm) to 6" (15.2 cm) or larger diameter transition piece if using 6" (15.2 cm) or larger diameter round vent system.

3 - UL listed wire connectors

For cabinets with recessed bottoms:

Two 2" (5.1 cm) wide filler strips. Length and thickness determined by recess dimensions.

Four flat head wood screws or machine screws with washers and nuts (to attach filler strips).

Location Requirements

IMPORTANT: Observe all governing codes and ordinances.

It is the installer’s responsibility to comply with installation clearances specified on the model/serial rating plate. The model/serial rating plate is located inside the range hood on the left wall.

Range hood location should be away from strong draft areas, such as windows, doors and strong heating vents.

Cabinet opening dimensions that are shown must be used. Given dimensions provide minimum clearance. Consult the cooktop/range manufacturer installation instructions before making any cutouts.

Grounded electrical outlet is required. See “Electrical Requirements” section.

The hood is factory-set for vented installations.

All openings in ceiling and wall where range hood will be installed must be sealed.

For Mobile Home Installations

The installation of this range hood must conform to the Manufactured Home Construction Safety Standards, Title 24 CFR, Part 328 (formerly the Federal Standard for Mobile Home Construction and Safety, title 24, HUD, Part 280)

or when such standard is not applicable, the standard for Manufactured Home Installation 1982 (Manufactured Home Sites, Communities and Setups) ANSI A225.1/NFPA 501A*, or latest edition, or with local codes.

Product Dimensions

1³⁄ "

4¹⁄" (10.3 cm)

(4.4 cm)

 

 

4³⁄ "

 

1"

(12.1 cm)

 

(2.5 cm)

³⁄ "

 

9"

(2.0 cm)

 

 

 

(22.9 cm)

29¹ ⁄" (76.0 cm)

1¹⁄ "

20"

 

(3.8 cm)

 

(50.8 cm)

®†TORX is a registered trademark of Acument Intellectual Properties, LLC

4

Installation Clearances

C

B

D

A

E

A.18" (45.7 cm) min. clearance - upper cabinet to countertop

B.24" (61.0 cm) min. for electric cooking surfaces

27" (68.6 cm) min. for gas cooking surfaces

30" (76.2 cm) suggested max. - bottom of range hood to cooking surface

C.30" (76.2 cm) min. cabinet opening width

D.13" (33.0 cm) cabinet depth

E.36" (91.4 cm) base cabinet height

Venting Requirements

Vent system must terminate to the outdoors.

Do not terminate the vent system in an attic or other enclosed area.

Do not use a 4" (10.2 cm) laundry-type wall cap.

Use a 6" (15.2 cm) or larger round metal vent or a 3¼" x 10" (8.3 x 25.4 cm) rectangular metal vent. Rigid metal vent is recommended. Plastic or metal foil vent is not recommended.

The length of vent system and number of elbows should be kept to a minimum to provide efficient performance.

For the most efficient and quiet operation:

Use no more than three 90° elbows.

Make sure there is a minimum of 24" (61 cm) of straight vent between the elbows if more than 1 elbow is used.

Do not install 2 elbows together.

Use clamps to seal all joints in the vent system.

The vent system must have a damper. If roof or wall cap has a damper, do not use damper supplied with the range hood.

Use caulking to seal exterior wall or roof opening around the cap.

Cold Weather Installations

An additional back draft damper should be installed to minimize backward cold air flow and a thermal break should be installed to minimize conduction of outside temperatures as part of the vent system. The damper should be on the cold air side of the thermal break.

The break should be as close as possible to where the vent system enters the heated portion of the house.

Makeup Air

Local building codes may require the use of make up air systems when using ventilation systems greater than specified CFM of air movement. The specified CFM varies from

locale to locale. Consult your HVAC professional for specific requirements in your area.

Venting Methods

Vent system can terminate either through the roof or wall. Use 3¼" x 10" (8.3 x 25.4 cm) with a maximum vent length of 35 ft (10.7 m) or 6" (15.2 cm) or larger round vent with a maximum length of 50 ft (15.2 m) for vent system.

NOTE: Flexible vent is not recommended. Flexible vent creates back pressure and air turbulence that gently reduces performance.

The ducting from this fan to the outside of the building has a strong effect on the air flow, noise and energy use of the fan. Use the shortest, straightest duct routing possible for best performance, and avoid installing the fan with smaller ducts than recommended. Insulation around the ducts can reduce energy loss and inhibit mold growth. Fans installed with existing ducts may not achieve their rated airflow.

A

E

A

 

 

 

B

 

B

F

 

C

E

 

F

C

 

 

 

 

 

D

 

D

 

 

 

 

A.6" (15.2 cm) or larger round vent or a 31/4" x 10" (8.3 x

25.4cm) rectangular vent through roof

B.Round vent: use 6" (15.2 cm) or larger round damper (purchased separately)

C.Round vent: use 31/4" x 10" (8.3 x 25.4 cm) to 6" (15.2 cm) or larger diameter transition piece

(purchased separately)

D.27" (68.6 cm) - 30" (76.2 cm) above gas cooking surface 24" (61.0 cm) - 30" (76.2 cm) above electric cooking surface

E.Roof cap

F.Seal duct joints with duct tape/caulk

A.6" (15.2 cm) or larger round vent or a 31/4" x 10" (8.3 x

25.4cm) rectangular vent through the wall

B.Round vent: use 31/4" x 10" (8.3 x 25.4 cm) to 6" (15.2 cm) or larger diameter transition piece (purchased separately)

C.31/4" x 10" (8.3 x 25.4 cm) through the wall

D.27" (68.6 cm) - 30" (76.2 cm) above gas cooking surface 24" (61.0 cm) - 30" (76.2 cm) above electric cooking surface

E.Wall cap

F.Seal duct joints with duct tape/caulk

Ensure duct joints and exterior penetrations are sealed with caulk or other similar material to create an air-tight path and to minimize building heat loss and gain and reduce the potential for condensation.

Place/wrap insulation around duct and/or fan in order to minimize possible condensation buildup within the duct,

building heat loss and gain.

5

Calculating Vent System Length

To calculate the length of the system you need, add the equivalent feet (meters) for each vent piece used in the system. 6" (15.2 cm) or Larger Round Vent System

Vent Piece

 

 

Round

 

 

45° elbow

 

 

2.5 ft

 

 

 

 

 

 

 

 

 

 

 

 

(0.8 m)

 

 

 

 

 

 

 

 

90° elbow

 

 

5.0 ft

 

 

 

 

 

 

 

 

 

 

 

 

(1.5 m)

 

 

 

 

 

 

 

 

6" (15.2 cm) or larger

 

 

0.0 ft

 

 

wall cap

 

 

(0.0 m)

 

 

 

 

 

 

3¹⁄ " x 10" (8.3 cm x 25.4 cm)

4.5 ft

 

 

to 6" (15.2 cm) or larger

 

 

(1.4 m)

 

 

 

 

 

 

3¹⁄ " x 10" (8.3 cm x 25.4 cm)

5.0 ft

 

 

to 6" (15.2 cm) or larger

 

 

(1.5 m)

 

 

90° elbow

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Example vent system

 

 

 

 

 

 

 

90˚ elbow

 

 

 

 

 

 

 

 

 

 

 

Wall cap

 

 

 

 

 

 

 

 

 

6 ft (1.8 m)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2 ft (0.6 m)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Maximum Recommended Length

= 50 ft (15.2 m)

 

 

 

 

 

 

 

 

 

1 - 90° elbow

 

 

 

 

 

= 5.0 ft (1.5 m)

 

1 - wall cap

 

 

 

 

 

= 0.0 ft (0.0 m)

 

8 ft (2.4 m) straight

 

 

 

 

 

= 8.0 ft (2.4 m)

 

 

 

 

 

 

 

Length of 7" (17.8 cm) system

 

 

 

= 13.0 ft (3.9 m)

 

3¼" x 10" (8.3 cm x 25.4 cm) Vent System

Vent Piece

 

3¼" x 10" (8.3 cm x 25.4 cm)

5.0 ft

 

 

90° elbow

(1.5 m)

 

 

 

 

 

 

3¼" x 10" (8.3 cm x 25.4 cm)

12.0 ft

 

 

flat elbow

(3.7 m)

 

 

 

 

 

 

3¼" x 10" (8.3 cm x 25.4 cm)

0.0 ft

 

 

wall cap

(0.0 m)

 

Example vent system

3¹⁄" x 10"

 

 

(8.3 x 25.4 cm)

 

 

elbow

6 ft (1.8 m)

Wall cap

 

2 ft

(0.6 m)

 

Maximum Recommended Length

= 35 ft (10.7 m)

 

 

 

 

 

 

1 - 90° elbow

= 5.0 ft (1.5 m)

 

 

8 ft (2.4 m) straight

= 8.0 ft (2.4 m)

 

 

1 - wall cap

= 0.0 ft (0.0 m)

 

 

 

 

 

 

Length of 3¼" x 10" (8.3 cm x 25.4 cm)

= 13.0 ft (3.9 m)

 

 

system

 

 

6

Electrical Requirements

Observe all governing codes and ordinances.

Ensure that the electrical installation is adequate and in conformance with National Electrical Code, ANSI/NFPA 70 (latest edition), or CSA Standards C22.1-94, Canadian Electrical Code, Part 1 and C22.2 No. 0-M91 (latest edition) and all local codes and ordinances.

If codes permit and a separate ground wire is used, it is recommended that a qualified electrician determine that the ground path is adequate.

A copy of the above code standards can be obtained from:

National Fire Protection Association

One Batterymarch Park

Quincy, MA 02269

CSA International

8501 East Pleasant Valley Road

Cleveland, OH 44131-5575

A 120 Volt, 60 Hz., AC only, 15-amp, fused electrical circuit is required.

If the house has aluminum wiring, follow the procedure below:

1.Connect a section of solid copper wire to the pigtail leads.

2.Connect the aluminum wiring to the added section of copper wire using special connectors and/or tools designed and UL listed for joining copper to aluminum.

Follow the electrical connector manufacturer's . recommended procedure. Aluminum/copper connection .

must conform with local codes and industry accepted

.

wiring practices.

 

Wire sizes and connections must conform with the rating of the appliance as specified on the model/serial rating plate. The model/serial plate is located behind the filter on the rear wall of the range hood.

Wire sizes must conform to the requirements of the National Electrical Code, ANSI/NFPA 70 (latest edition), or CSA Standards C22. 1-94, Canadian Electrical Code, Part 1 and C22.2 No. 0-M91 (latest edition) and all local codes and ordinances.

INSTALLATION INSTRUCTIONS

Prepare Location

NOTE: It is recommended that the vent system be installed before hood is installed.

Before making cutouts, make sure there is proper clearance within the ceiling or wall for exhaust vent.

1.Disconnect power.

2.Determine which venting method to use: roof or wall.

3.Select a flat surface for assembling the range hood. Place covering over that surface.

4.Lift the range hood and set it upside down onto covered surface.

5.If cabinet has recessed bottom, add wood filler strips on each side. Install screws to attach filler strips in locations shown.

Wood filler strips (recessed cabinet bottoms only)

3" (7.6 cm)

Cabinet

bottom

3" (7.6 cm)

Wall

Determine Wiring Hole Location

Cut only one 114" (3.2 cm) diameter wiring access hole. See Step 2 for wiring hole location instructions.

1.Determine and clearly mark a vertical centerline on the wall and cabinet in the area the vent opening will be made.

A

A. Centerline

2.To wire through top:

Mark a line distance “A” from the right of the centerline on the underside of the cabinet. Mark the point on this line that is 134" (4.4 cm) from back wall. Drill a 1¼" (3.2 cm) diameter hole through the cabinet at this point.

A1¹⁄" (4.3 cm) from wall, not cabinet frame

Centerline

A. 1078" (27.6 cm)

7

3.To wire through wall:

Mark a line distance “A” from the right of the centerline on the underside of the wall. Mark the point on this line that is

34" (1.9 cm) from the underside of the cabinet. Drill a 114" (3.2 cm) diameter hole through the rear wall at this point.

³⁄" (1.9 cm)

A

Centerline

A. 1078" (27.6 cm)

Style 1 - Cut Openings for 3¼" x 10" (8.3 cm x 25.4 cm) Rectangular Vent System

Roof Venting

To make a 414" x 10½" (10.8 cm x 26.7 cm) rectangular cutout on the underside of cabinet top and bottom:

1.Mark lines 12" (1.3 cm) and 434" (12.1 cm) from the back wall on the centerline of the underside of cabinet.

2.Mark lines 5¼" (13.3 cm) to the right and left of the centerline on the underside of cabinet.

3.Use saber or keyhole saw to cut a rectangular opening for vent.

4.Repeat steps 1-3 for the underside of the top of the cabinet.

Cabinet cutouts

*¹⁄ " (1.3 cm)

*4³⁄ "

5¹/ "

(13.3 cm)

 

(12.1 cm)5¹/ "

(13.3 cm)

*From wall, not cabinet frame

Wall Venting

To make a 3½" x 10½" (8.9 cm x 26.7 cm) rectangle in the wall:

1.Make 2 lines by measuring 38" (0.9 cm) and 378" (9.8 cm) down from underside of cabinet and mark on the centerline on the back wall.

2.Mark lines 5¼" (13.3 cm) to the right and left of the centerline on the wall.

3.Use saber or keyhole saw to cut a rectangular opening in the wall for the vent.

Centerline

Cabinet

front

³⁄"

(0.9 cm)

3 ⁄"

(9.8 cm)

5¹⁄ "

5¹⁄ "

(13.3 cm)

(13.3 cm)

Style 2 - Cut Openings for 3¼" x 10" (8.3 x 25.4 cm) Rectangular Vent to Round Vent Transition

Roof Venting

To make a 414" x 10½" (10.8 cm x 26.7 cm) rectangular cutout on the underside of cabinet bottom:

1.Mark lines 12" (1.3 cm) and 434" (12.1 cm) from the back wall on the centerline of the underside of cabinet.

2.Mark lines 5¼" (13.3 cm) to the right and left of the centerline on the underside of cabinet.

3.Use saber or keyhole saw to cut a rectangular opening for vent.

 

*¹⁄ " (1.3 cm)

*4³⁄ "

5¹/ "

(12.1 cm)

(13.3 cm)

5¹/ "

(13.3 cm)

*From wall, not cabinet frame

To make a circular vent opening on the underside of the cabinet top:

1.Mark a centerline on the underside of the top of cabinet.

2.Mark a line 5" (12.7 cm) from the back wall on the underside of the top of cabinet.

3.Use a compass or a circle template to draw a circle with a diameter that is ¼" (0.64 cm) larger than the vent.

4.Use saber or keyhole saw to cut the circular vent opening.

Circular vent opening

*5"

(12.7 cm)

Cabinet

cutouts

*From wall, not cabinet frame

8

Install Vent System

1.Install vent through the vent opening in upper cabinet or wall. Complete venting system according to the selected venting method. See “Venting Requirements” section.

2.Use caulking to seal exterior wall or roof opening around the cap.

Install Range Hood

Complete Preparation

1.Remove the grease filters. See the “Range Hood Care” section.

Depending on your installation, remove either top or rear rectangular vent knockout. If using round vent, remove top rectangular knockout.

Make sure damper pivot is nearest to top/back edge of range hood.

Remove tape from damper flap.

NOTE: The exhaust adaptor/damper can be installed up to 1" (2.5 cm) on either side of the hood center to accommodate off-center ductwork.

If using rectangular vent, attach rectangular damper/ vent connectors to the range hood using sheet metal screws.

B

A

C

D

E

C

B

A.Vertical vent

B.Sheet metal screws

C.Hinge pin

D.Vent knockouts

E.Horizontal vent

NOTE: If the wall cap is directly behind the vent connector, the dampers in the connector and wall cap must not interfere with each other. Remove the vent connector damper if they interfere.

If using round vent, attach vent transition piece (purchased separately) to range hood top using sheet metal screws.

2.Lift the range hood up under cabinet and determine final location by centering beneath cabinet. Mark on the underside of cabinet the location of the 4 keyhole mounting slots on the range hood. Set range hood aside on a covered surface.

A

A.Keyhole slot

3.Use 18" (3 mm) drill bit and drill 4 pilot holes as shown.

A

A.Drill pilot hole.

4.Install the 4 - 4.5 mm x 13 mm mounting screws in pilot holes. Leave about 14" (6.4 cm) space between screw heads and cabinet to slide range hood into place.

¹⁄"

(6.4 mm)

5.Run the home power supply cable according to the National Electric Code or CSA standards and local codes and ordinances. There must be enough wiring from the fused disconnect (or circuit breaker) box to make the connection in the hood electrical terminal box.

NOTE: Do not reconnect power until the installation is complete.

6.Remove the screws from the terminal box cover. Then slide the cover toward the outside edge of range hood to position the large end of the keyhole slots over the mounting tabs.

A

B

C

A.Screws

B.Mounting tabs

C.Terminal box cover

9