Tripp Lite SU3000RTXL2U User Manual

0 (0)
Tripp Lite SU3000RTXL2U User Manual

Tripp Lite

1111 West 35th Street

Chicago, IL 60609 USA Telephone: +(773) 869 1234 E-mail: saleshelp@tripplite.com

Model #: SU3000RTXL2U

SmartOnline Expandable 2U Rack / Tower UPS System - On-line, double-conversion, sine wave UPS with PDU switching, current monitoring and fault tolerant auto-bypass

Highlights

3000VA / 3 kVA / 2500 watt on-line, double-conversion, extended run 2U rack/tower UPS

Economy mode option offers 97% efficiency, reduces power consumption and

BTU emissions

Maintains selectable 100/110/115/120/127V +/-2% output during brownouts and overvoltages from 70 to 144V (50/60 Hz auto-sensing)

Simultaneous communications via USB, serial, contact closure, EPO and

SNMP/Web card slot accessory

Fault-tolerant auto-bypass, current monitoring and 2 load bank switched PDU control

Input: L5-30P (120V 30A) / Output: 6 5-15/20R & 1 L5-30R

2 year product warranty / $250,000 Ultimate Lifetime Insurance (USA &

Canada only)

Description

3000VA / 3kVA / 2500 watt on-line, double-conversion UPS system features optional economy-mode operation with 97% efficiency for reduced power consumption and cooler operation. Uninterruptible Power Supply (UPS) actively converts raw incoming AC power to DC, then re-converts output back to completely regulated, filtered AC output. 2U rack / tower / wallmount compatible form factor with depth of only 26 inches (66 cm) offers ideal protection for critical server, networking and telecommunications equipment in datacenters and remote equipment closets. Ships factory configured for 120V operation and offers selectable voltage operation for 100/110/115 and 127V nominal voltages. Connects to L5-30R utility receptacle (120V 30A) and offers outlets compatible with common 5-15P, 5-20P and L5-30P equipment or PDU plugs. Network-grade AC surge and noise suppression. Zero transfer time between AC and battery operation in online mode. Network management interfaces include USB port, DB9 serial port and SNMPWEBCARD slot. Built-in DB9 port offers both enhanced RS-232 enabled monitoring data, plus contact closure monitoring ability. HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X. Supports simultaneous detailed monitoring of equipment load levels, self-test data and mains power conditions via all network interfaces at once. Includes PowerAlert monitoring software and complete cabling. Emergency Power Off (EPO) interface. Integrated two bank PDU switching supports automated load shedding and remote-reboot of connected equipment. 4 stage metered current monitoring and battery charge status LEDs. Mains power and voltage regulation LEDs. Audible Alarm. Self-test. Fault-tolerant auto-bypass mode. LED display panel easily rotates for better viewing in rackmount or tower configurations. Includes 4 post rackmount accessories. 2-9USTAND tower kit and 2POSTRMKITWM two post rackmount and wall-mount hardware accessories available. Field replaceable, hot swappable internal batteries and external battery packs. Two year warranty with $250,000 connected equipment insurance. Extended warranty and service contracts available.

Applications

Ideal for protection of critical 120V equipment in server rooms, internetworking closets and telecommunications systems in rackmount or tower applications. Common applications include corporate or departmental servers, workstations, hubs, routers, bridges, CAD/CAM workstations, concentrators, IP telephony and traditional PBX switching systems.

Package Includes

SU3000RTXL2U UPS System

4 post rackmount installation brackets

PowerAlert Software CD and cabling

Owner's manual with warranty information

Features

SmartOnline high-performance UPS system is ideal for critical voice, data, medical and industrial network applications

Optional economy-mode operation with 97% efficiency for reduced power consumption and cooler operation

Economy mode is schedulable via PowerAlert UPS management software for daily or weekly hours of operation to enable precision output during peak operating hours and high efficiency, low BTU emission operation during off-peak times

Maintains continuous operation through blackouts, voltage fluctuations

On-line, double-conversion mode provides perfectly regulated sine wave output within 2% of 100/110/115/120/127V (user selectable) with zero transfer time

Supports operation at 50/60Hz (auto-sensing) with the ability for full-time frequency conversion from 50 to 60Hz or 60 to 50Hz (frequency conversion de-rates UPS capacity by 25% - see specifications)

Removes harmonic distortion, fast electrical impulses, frequency variations and other hard to solve power problems not addressed by other UPS types

Corrects line voltage conditions as low as 70V and as high as 144V to within 2% of selected nominal voltage

Standard internal battery set offers 15 minutes runtime at half load (1250W) and 6 minutes at full load (2500W)

Expandable battery runtime with optional BP72V15-2U and BP72V28RT-3U external battery packs

Compact rackmount form factor installs using only 2 rack spaces (2U) with a depth of only 26 inches

Ships with all mounting accessories for 4 post rackmount installation

Optional 2POSTRMKITWM enables 2 post rackmount or wallmount installation

Optional 2-9USTAND accessory enables upright tower placement

Fault tolerant auto-bypass maintains continuous utility output to connected equipment, even in cases where the UPS suffers internal failure and requires maintenance

Network interfaces support simultaneous communications via built-in USB, DB9 serial / contact-closure and SNMPWEBCARD slot

HID compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X. Included PowerAlert UPS monitoring software supports safe unattended shutdown, monitoring and control via local connected servers, plus any number of additional servers over IP

UPS interface supports on-battery, low-battery, power-restored, AC-voltage, DC-voltage, output current monitoring, battery charge current, battery capacity, AC line frequency, timed inverter shutoff, activate self-test, load bank output power control and remote reboot, UPS nominal voltage adjustment and UPS line to battery power voltage setpoints

Built-in Emergency Power Off (EPO) interface with cable

NEMA L5-30P input plug / NEMA 5-15/20R & L5-30R output receptacles

Integrated 2 bank switched PDU enables remote outlet management for load shedding or remote reboot of individual load banks (each bank has 3 outlets)

Front panel LEDs offer current monitoring and battery charge level information

Network grade AC surge suppression

Field replaceable, hot swappable internal batteries and external battery packs

2 year manufacturer's product warranty; $250,000 Ultimate Lifetime Insurance

Extended warranty and service contracts available

Specifications

SYSTEM OVERVIEW

Voltage

100/110/115/120/127VAC (factory configured for 120v)

compatibility

 

 

 

Frequency

50/60Hz Auto-sensing

compatibility

 

 

 

OUTPUT

 

Output VA

3000

 

 

Output watts

2500 watts (120/127V nominal) / 2400 watts (100/110/115V nominal)

 

 

Output nominal

100/110/115/120/127VAC (factory configured for 120v)

voltage

 

 

 

Output voltage

+/- 2% in standard double-conversion mode (+10% / -12% in economy mode)

regulation

 

 

 

Loading...
+ 4 hidden pages