TP-Link TL-SG1008P Installation Guide

8-Port Gigabit Desktop Switch with 4-Port PoE
TL-SG1008P
Connection
Application
1
7106506017 REV1.0.0
For more information, please visit our website: http://www.tp-link.com
Ethernet Ports (1-8)
Internet
Router
LAN PortWAN Port
Note:
1.
PoE ports can also connect to non-PoE devices, but only transmit data.
2.
Maximum PoE power is 15.4W for each PoE port and 55W for all PoE ports.
PC
PoE Devices
IP Camera AP
PoE Ports (1-4)
IP Phone
Plug and Play
2
1
DC Power Adapter
AC Power Cord
2 3
LED Explanation
PoE Max
On: 48W≤Total power supply < 55W Flashing: Total power supply ≥ 55W Off: Total power supply < 48W
PoE Status (port 1-4)
On: Providing PoE power Flashing: PoE fault Off: Not providing PoE power
Link/Act (port 1-8)Power
On: Power on Off: Power off
On: Link present but no activity Flashing: Transmitting/receiving data Off: No link
Frequently Asked Questions (FAQ)
Q1. The Power LED is not lit.
The Power LED should be lit when the power system is working normally. If the Power LED is not lit, please check as follows:
A1:
Make sure the AC power cord is connected to the switch with power source properly.
A2:
Make sure the voltage of the power supply meets the requirements of the input voltage of the switch.
A3:
Make sure the power source is on.
Q2. The Link/Act LED is not lit when a device is connected to the corresponding port.
It is recommended that you check the following items:
A1:
Make sure that the cable connectors are firmly plugged into the switch and the device.
A2:
Make sure the connected device is turned on and working well.
A3:
The cable must be less than 100 meters long (328 feet).
Q3. Why is port 4 not supplying power for PoE devices?
If connected PoE device’s total power consumption exceeds 55W, the system will cut off the power to port 4. For example, port 1, 2 and 4 are consuming 15.4W respectively, if an additional PoE device with 12W is inserted to port 3, the system will cut off the power of port 4 to compensate for the overload.
1000Mbps (port 1-8)
On: Link/Act at 1000M Off: Link/Act at 10/100M or no link
General Specifications
Standard Protocol
Interface
Network Media (Cable)
PoE Ports (RJ45)
Backbone Bandwidth MAC Address Table Transfer Method
Power Supply
Consumption
Environmental and Physical Specifications
Certification Operating Temperature Storage Temperature Operating Humidity Storage Humidity
IEEE802.3i, 802.3u, 802.3ab, 802.3x, 802.3af, 802.1p
CSMA/CD 8 10/100/1000Mbps RJ45 Ports Auto-Negotiation/Auto MDI/MDIX 10BASE-T: UTP category 3, 4, 5 cable (maximum 100m); EIA/TIA-568 100 100BASE-TX: UTP category 5, 5e cable (maximum 100m); EIA/TIA-568 100 1000BASE-T: UTP category 5e cable or above (maximum 100m); EIA/TIA-568 100 100m) PoE Ports: Port1- Port4 Total Power Supply: 55W 16Gbps 4K Store-and-Forward External Power Adapter (Input: 100-240VAC, 50/60Hz Output: 48VDC /1.25A)
5.5W (max. no PoE device connected)
65.2W (max. with 55w PoE device connected)
FCC, CE, RoHS 0˚C~40˚C (32˚F~104˚F)
-40˚C~70˚C (-40˚F~158˚F) 10%~90% non-condensing 5%~90% non-condensing
Ω
STP (maximum 100m)
Ω
STP (maximum 100m)
Ω
STP (maximum
SAFETY Information
Adapter shall be installed near the equipment and shall be easily accessible. Avoid water and wet locations. Don’t disassemble the product, or make repairs yourself. You run the risk of electric shock and voiding the limited warranty. If you need service, please contact us.
COPYRIGHT & TRADEMARKS
Specifications are subject to change without notice. is a registered trademark of TP-LINK TECHNOLOGIES CO., LTD. Other brands and product names are trademarks or registered trademarks of their respective holders. No part of the specifications may be reproduced
in any form or by any means or any derivative such as translation, transformation, or adaptation without permission from TP-LINK TECHNOLOGIES CO., LTD. Copyright © 2016 TP-LINK TECHNOLOGIES CO., LTD. All rights reserved.
http://www.tp-link.com
CE Mark Warning
This is a class A product. In a domestic environment, this product may cause radio interference, in which case the user may be required to take adequate measures.
used to make
FCC STATEMENT
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful
interference in which case the user will be required to correct the interference at his own expense. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
1) This device may not cause harmful interference.
2) This device must accept any received, including interference that may cause undesired operation. Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
interference
Loading...